Maria Ofelia Moroni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Maria Ofelia Moroni has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Mauricio Sarrazin
University of Chile Blanco Encalada 2002 Santiago Chile
6 shared publications- Ruben Boroschek
Civil Engineering Department, University of Chile, Santiago, Chile
4 shared publications Aquiles Sepúlveda
3 shared publications- Paul N. Roschke
Texas A&M University, College Station, TX
3 shared publications - Mauricio Sarrazin
Universidad de Chile
2 shared publications - Ricardo Herrera
Associate Professor, Dept. of Civil Engineering, Univ. of Chile, Blanco Encalada, Santiago 2002, Chile. ORCID:
2 shared publications
Latest Publications
- Open Access
- 1 April 2015
- Published by Pontificia Universidad Catolica de Chile in Revista de la construcción
- Vol. 14 (1) , 53-59
Seismic behavior of chilean bridges with seismic protection devices
- 1 April 2015
- Published by Pontificia Universidad Catolica de Chile in Revista de la construcción
- Vol. 14 (1) , 53-59
Open AccessSeismic behavior of chilean bridges with seismic protection devices
- 1 June 2012
- Published by Wiley in Earthquake Spectra
- Vol. 28 (1S1) , 407-424
Behavior of Instrumented Base‐Isolated Structures during the 27 February 2010 Chile Earthquake
Several buildings and bridges with base isolation were in the area struck by the 27 February 2010, M w 8.8 Maule earthquake. A building and two bridges that were instrumented with networks of accelerometers registered the quake; these records are analyzed here. Results of this kind are very valuable because a strong motion earthquake of large magnitude occurs only from time to time, and these rather new types of structures had not been exposed to such severe action. The isolated building is a four‐story reinforced concrete and confined masonry structure located in the city of Santiago. The bridges are: (a) a 368m long continuous bridge located in Viña del Mar and (b) one section of a Santiago metropolitan train viaduct. Results show important reductions in horizontal accelerations, especially at the roof level of the building (to nearly 20% of the twin fixed‐base case), and in the longitudinal direction of the bridges.
- 1 June 2012
- Published by Wiley in Earthquake Spectra
- Vol. 28 (1S1) , 407-424
Behavior of Instrumented Base‐Isolated Structures during the 27 February 2010 Chile Earthquake
Several buildings and bridges with base isolation were in the area struck by the 27 February 2010, M w 8.8 Maule earthquake. A building and two bridges that were instrumented with networks of accelerometers registered the quake; these records are analyzed here. Results of this kind are very valuable because a strong motion earthquake of large magnitude occurs only from time to time, and these rather new types of structures had not been exposed to such severe action. The isolated building is a four‐story reinforced concrete and confined masonry structure located in the city of Santiago. The bridges are: (a) a 368m long continuous bridge located in Viña del Mar and (b) one section of a Santiago metropolitan train viaduct. Results show important reductions in horizontal accelerations, especially at the roof level of the building (to nearly 20% of the twin fixed‐base case), and in the longitudinal direction of the bridges.
- 1 June 2012
- Published by Wiley in Earthquake Spectra
- Vol. 28 (1S1) , 385-406
Seismic Performance of Engineered Masonry Buildings in the 2010 Maule Earthquake
Engineered masonry, namely reinforced and confined masonry, has been widely used for housing construction in Chile over the last few decades. Most one‐ and two‐story single‐family masonry dwellings did not experience any damage due to the 27 February 2010 Maule earthquake, with the exception of a few dwellings of pre‐1970 vintage, which suffered moderate damage. A similar statement can be made for three‐ and four‐story confined masonry buildings: a large majority of buildings remained undamaged. However, several reinforced and partially confined three‐ and four‐story masonry buildings suffered extensive damage, and two three‐story partially confined buildings collapsed. The key damage patterns and the causes of damage are discussed in the paper. The extent of damage observed in the field was correlated with calculated vulnerability indices, and relevant recommendations were made related to the design and construction practices.
- 1 June 2012
- Published by Wiley in Earthquake Spectra
- Vol. 28 (1S1) , 385-406
Seismic Performance of Engineered Masonry Buildings in the 2010 Maule Earthquake
Engineered masonry, namely reinforced and confined masonry, has been widely used for housing construction in Chile over the last few decades. Most one‐ and two‐story single‐family masonry dwellings did not experience any damage due to the 27 February 2010 Maule earthquake, with the exception of a few dwellings of pre‐1970 vintage, which suffered moderate damage. A similar statement can be made for three‐ and four‐story confined masonry buildings: a large majority of buildings remained undamaged. However, several reinforced and partially confined three‐ and four‐story masonry buildings suffered extensive damage, and two three‐story partially confined buildings collapsed. The key damage patterns and the causes of damage are discussed in the paper. The extent of damage observed in the field was correlated with calculated vulnerability indices, and relevant recommendations were made related to the design and construction practices.
- 1 October 2011
- Published by Elsevier in Engineering Structures
- Vol. 33 (10) , 2910-2918
Shape memory alloy CuAlBe strands subjected to cyclic axial loads
- 1 October 2011
- Published by Elsevier in Engineering Structures
- Vol. 33 (10) , 2910-2918
Shape memory alloy CuAlBe strands subjected to cyclic axial loads
- 16 October 2009
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 13 (8) , 1153-1171
Optimal Control of Accelerations in a Base-Isolated Building using Magneto-Rheological Dampers and Genetic Algorithms
- 16 October 2009
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 13 (8) , 1153-1171
Optimal Control of Accelerations in a Base-Isolated Building using Magneto-Rheological Dampers and Genetic Algorithms
- 1 November 2008
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 496 (1-2) , 209-213
Temperature and grain size effects on the behavior of CuAlBe SMA wires under cyclic loading
- 1 November 2008
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 496 (1-2) , 209-213
Temperature and grain size effects on the behavior of CuAlBe SMA wires under cyclic loading
- 14 October 2008
- Published by American Society of Civil Engineers (ASCE)
- p. 1-10
Analytical Evaluation of Various Passive Isolation Systems on Seismic Performance of a Low-Cost Chilean Masonry House
In this study, a multi-degree-of-freedom numerical model is created to represent the elastic behavior of a typical Chilean two-family, low-cost, confined masonry house. Ambient vibration testing was performed to determine the fundamental natural frequencies of the structure in the longitudinal and transverse directions through a non-parametric system identification technique. Based on the ambient vibration data, an estimation of equivalent viscous damping of the structure is made using the bandwidth method. The stiffness values are estimated using the natural frequencies measured from the ambient vibration testing. A number of passive isolation devices are considered as potential isolation systems for the structure. Each device is numerically modeled using fuzzy logic. The fuzzy models are created using experimental and analytical data to predict the force exerted on the structure by the device. The passive isolation systems considered include friction pendulum systems, high-damping rubber bearings, and two hybrid systems involving use of high-damping rubber bearings and shape memory alloy wire. Seismic performance of the structure in the longitudinal direction, augmented with each of the isolation systems mentioned above is compared with the performance of the traditionally-constructed structure using several performance indices.
- 14 October 2008
- Published by American Society of Civil Engineers (ASCE)
- p. 1-10
Analytical Evaluation of Various Passive Isolation Systems on Seismic Performance of a Low-Cost Chilean Masonry House
In this study, a multi-degree-of-freedom numerical model is created to represent the elastic behavior of a typical Chilean two-family, low-cost, confined masonry house. Ambient vibration testing was performed to determine the fundamental natural frequencies of the structure in the longitudinal and transverse directions through a non-parametric system identification technique. Based on the ambient vibration data, an estimation of equivalent viscous damping of the structure is made using the bandwidth method. The stiffness values are estimated using the natural frequencies measured from the ambient vibration testing. A number of passive isolation devices are considered as potential isolation systems for the structure. Each device is numerically modeled using fuzzy logic. The fuzzy models are created using experimental and analytical data to predict the force exerted on the structure by the device. The passive isolation systems considered include friction pendulum systems, high-damping rubber bearings, and two hybrid systems involving use of high-damping rubber bearings and shape memory alloy wire. Seismic performance of the structure in the longitudinal direction, augmented with each of the isolation systems mentioned above is compared with the performance of the traditionally-constructed structure using several performance indices.
- 1 April 2008
- Published by Elsevier in Journal of Constructional Steel Research
- Vol. 64 (4) , 429-435
Steel beam–column connection using copper-based shape memory alloy dampers
- 1 April 2008
- Published by Elsevier in Journal of Constructional Steel Research
- Vol. 64 (4) , 429-435
Steel beam–column connection using copper-based shape memory alloy dampers
- 4 May 2007
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 16 (3) , 818-829
A fuzzy model of superelastic shape memory alloys for vibration control in civil engineering applications
Two experimental test programs are conducted to collect data and simulate the dynamic behavior of CuAlBe shape memory alloy (SMA) wires. First, in order to evaluate the effect of temperature changes on superelastic SMA wires, a large number of cyclic, sinusoidal, tensile tests are performed at 1 Hz. These tests are conducted in a controlled environment at 0, 25 and 50 ◦C with three different strain amplitudes. Second, in order to assess the dynamic effects of the material, a series of laboratory experiments is conducted on a shake table with a scale model of a three-story structure that is stiffened with SMA wires. Data from these experiments are used to create fuzzy inference systems (FISs) that can predict hysteretic behavior of CuAlBe wire. Both fuzzy models employ a total of three input variables (strain, strain-rate, and temperature or pre-stress) and an output variable (predicted stress). Gaussian membership functions are used to fuzzify data for each of the input and output variables. Values of the initially assigned membership functions are adjusted using a neural-fuzzy procedure to more accurately predict the correct stress level in the wires. Results of the trained FISs are validated using test results from experimental records that had not been previously used in the training procedure. Finally, a set of numerical simulations is conducted to illustrate practical use of these wires in a civil engineering application. The results reveal the applicability for structural vibration control of pseudoelastic CuAlBe wire whose highly nonlinear behavior is modeled by a simple, accurate, and computationally efficient FIS. (Some figures in this article are in colour only in the electronic version)
- 4 May 2007
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 16 (3) , 818-829
A fuzzy model of superelastic shape memory alloys for vibration control in civil engineering applications
Two experimental test programs are conducted to collect data and simulate the dynamic behavior of CuAlBe shape memory alloy (SMA) wires. First, in order to evaluate the effect of temperature changes on superelastic SMA wires, a large number of cyclic, sinusoidal, tensile tests are performed at 1 Hz. These tests are conducted in a controlled environment at 0, 25 and 50 ◦C with three different strain amplitudes. Second, in order to assess the dynamic effects of the material, a series of laboratory experiments is conducted on a shake table with a scale model of a three-story structure that is stiffened with SMA wires. Data from these experiments are used to create fuzzy inference systems (FISs) that can predict hysteretic behavior of CuAlBe wire. Both fuzzy models employ a total of three input variables (strain, strain-rate, and temperature or pre-stress) and an output variable (predicted stress). Gaussian membership functions are used to fuzzify data for each of the input and output variables. Values of the initially assigned membership functions are adjusted using a neural-fuzzy procedure to more accurately predict the correct stress level in the wires. Results of the trained FISs are validated using test results from experimental records that had not been previously used in the training procedure. Finally, a set of numerical simulations is conducted to illustrate practical use of these wires in a civil engineering application. The results reveal the applicability for structural vibration control of pseudoelastic CuAlBe wire whose highly nonlinear behavior is modeled by a simple, accurate, and computationally efficient FIS. (Some figures in this article are in colour only in the electronic version)
- 1 May 2007
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 19 (5) , 428-436
Mechanical Properties and Fuzzy Modeling of High-Damping Rubber with Thermal Effects
An experimental program is reported in which the mechanical properties of high-damping natural rubber were measured. Rubber specimens were tested using a custom-designed mechanical apparatus that is equipped with a temperature chamber as well as displacement and force transducers. Each specimen was subjected to a wide range of carefully controlled dynamic loading tests. Variables studied include the strain, strain rate, and temperature of the material. Results from laboratory testing were used to formulate a fuzzy model of mechanical behavior for shear of the rubber compound. Instead of a mathematical representation of the high-damping rubber material, a Takagi-Sugeno-Kang fuzzy inference system is used to relate three input variables with the shear stress. Parameters of seven membership functions are determined through the use of an (adaptive neurofuzzy inference system). Experimental data applied for training and checking of the model are concatenated sets. The resulting fuzzy inference system is shown ...
- 1 May 2007
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 19 (5) , 428-436
Mechanical Properties and Fuzzy Modeling of High-Damping Rubber with Thermal Effects
An experimental program is reported in which the mechanical properties of high-damping natural rubber were measured. Rubber specimens were tested using a custom-designed mechanical apparatus that is equipped with a temperature chamber as well as displacement and force transducers. Each specimen was subjected to a wide range of carefully controlled dynamic loading tests. Variables studied include the strain, strain rate, and temperature of the material. Results from laboratory testing were used to formulate a fuzzy model of mechanical behavior for shear of the rubber compound. Instead of a mathematical representation of the high-damping rubber material, a Takagi-Sugeno-Kang fuzzy inference system is used to relate three input variables with the shear stress. Parameters of seven membership functions are determined through the use of an (adaptive neurofuzzy inference system). Experimental data applied for training and checking of the model are concatenated sets. The resulting fuzzy inference system is shown ...