Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Cheng-Sheng Huang has a total of 70 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effects of Illumination and Resonance Spectral Conditions on the Sensing Performance of Guided-Mode Resonance Sensors

    by Shih-Chuan Huang, Cheng-Sheng Huang

    Intensity-based interrogation is a simple, inexpensive readout strategy for guided-mode resonance (GMR) sensors; however, its performance depends on the overlap between illumination and resonance spectra. We developed an overlap integral model that quantifies a GMR sensor’s transmission intensity as a function of illumination wavelength, illumination and resonance full widths at half maximum (FWHMs), resonance efficiency, and wavelength offset from the resonance dip. By using normalized intensity sensitivity as a figure of merit, we demonstrated that positioning the illumination wavelength on the linear flank of the resonance yields higher sensitivity than centering it on the resonance dip for small GMR resonance FWHMs, especially under small refractive-index changes. Sensitivity increases with resonance efficiency and decreases with illumination FWHM but varies non-monotonically with resonance FWHM, revealing trade-offs among sensitivity, signal magnitude, and dynamic range. These predictions were experimentally validated using a GMR-integrated polydimethylsiloxane microfluidic chip interrogated by a tunable-FWHM monochromator and 0–10% sucrose solutions. The measured transmittance changes reproduced the predicted behaviors and the sensitivity gain from reducing the illumination linewidth from 3 to 1 nm. Overall, the results guide the selection of illumination offset, source linewidth, and resonance linewidth in the design of compact, spectrometer-free GMR sensors for point-of-care diagnostics.

  • Open Access

    Handheld Lab-on-a-Chip System for Label-Free Dual-Plex Detection of Biomarkers Through On-Chip Plasma Separation

    by Chen-Yuan Chang, Yuan-Pei Lei, Chien Chieh Chiang, Cheng-Sheng Huang

    Rapid and reliable detection of biomarkers in complex fluids such as whole blood is essential for effective disease diagnosis and monitoring, particularly in point-of-care settings. Accordingly, this study developed a handheld lab-on-a-chip (LOC) platform that integrates on-chip plasma separation with label-free optical biosensing for real-time, dual-plex detection of biomarkers. The LOC platform includes a two-stage filtration unit that enables efficient separation of plasma from whole blood. This platform also includes a novel gradient grating period guided-mode resonance sensor array that is capable of simultaneously detecting multiple biomarkers with high sensitivity. A compact handheld reader was developed to acquire and analyze optical signals. By using creatinine and albumin as model biomarkers, we demonstrated that the developed platform could achieve sensitive, specific, and reproducible biomarker detection in both plasma and whole-blood samples. The platform can detect albumin and creatinine at concentrations as low as 0.8 and 1.44 μg/mL, respectively, and it exhibits minimal nonspecific binding. These results highlight the potential of the proposed system as a robust and accessible tool for decentralized diagnostics.


  • Open Access

    Novel Deposition Technique for Fabricating Films with Customized Thickness Profiles

    by Chi-Yung Hsieh, Yu-Chi Lin, Xuan-Shan Huang, Jing-Ting Lin, Cheng-Sheng Huang

    This study introduces a novel deposition technique capable of depositing thin films with any arbitrary thickness profile. The apparatus consists of a fixed shadow mask and a rotating sample carrier plate. The shadow mask features a specifically designed opening curve that corresponds to the particular thickness profile of the deposited film. We successfully designed two shadow masks and used them to deposit films with linear thickness gradients of 49.3 and 86.8 Å/mm and films with sinusoidal thickness profiles with a period of 40 mm. Furthermore, a linear variable filter was designed on the basis of a quarter-wavelength stack of Si3N4 and SiO2, combined with a TiO2 cavity layer with a linearly varying thickness. By coaxially rotating the sample carrier plate relative to the shadow mask, films with the desired thickness profiles could be fabricated in a single deposition step without the need for additional rotational or translational devices inside the deposition chamber. By rotating the carrier plate, the chips attached at different circumferential positions can achieve consistent thickness profiles, making this method well-suited for mass production.


  • Open Access

    Blood Biomarker Detection Using Integrated Microfluidics with Optical Label-Free Biosensor

    by Chiung-Hsi Li, Chen-Yuan Chang, Yan-Ru Chen, Cheng-Sheng Huang

    In this study, we developed an optofluidic chip consisting of a guided-mode resonance (GMR) sensor incorporated into a microfluidic chip to achieve simultaneous blood plasma separation and label-free albumin detection. A sedimentation chamber is integrated into the microfluidic chip to achieve plasma separation through differences in density. After a blood sample is loaded into the optofluidic chip in two stages with controlled flow rates, the blood cells are kept in the sedimentation chamber, enabling only the plasma to reach the GMR sensor for albumin detection. This GMR sensor, fabricated using plastic replica molding, achieved a bulk sensitivity of 175.66 nm/RIU. With surface-bound antibodies, the GMR sensor exhibited a limit of detection of 0.16 μg/mL for recombinant albumin in buffer solution. Overall, our findings demonstrate the potential of our integrated chip for use in clinical samples for biomarker detection in point-of-care applications.


  • Open Access

    Handheld Biosensor System Based on a Gradient Grating Period Guided-Mode Resonance Device

    by Chien Chieh Chiang, Wen-Chun Tseng, Wen-Tsung Tsai, Cheng-Sheng Huang

    Handheld biosensors have attracted substantial attention for numerous applications, including disease diagnosis, drug dosage monitoring, and environmental sensing. This study presents a novel handheld biosensor based on a gradient grating period guided-mode resonance (GGP-GMR) sensor. Unlike conventional GMR sensors, the proposed sensor’s grating period varies along the device length; hence, the resonant wavelength varies linearly along the device length. If a GGP-GMR sensor is illuminated with a narrow band of light at normal incidence, the light resonates and reflects at a specific period but transmits at other periods; this can be observed as a dark band by using a complementary metal oxide semiconductor (CMOS) underneath the sensor. The concentration of a target analyte can be determined by monitoring the shift of this dark band. We designed and fabricated a handheld device incorporating a light-emitting diode (LED) light source, the necessary optics, an optofluidic chip with an embedded GGP-GMR sensor, and a CMOS. LEDs with different beam angles and bandpass filters with different full width at half maximum values were investigated to optimize the dark band quality and improve the accuracy of the subsequent image analysis. Substrate materials with different refractive indices and waveguide thicknesses were also investigated to maximize the GGP-GMR sensor’s figure of merit. Experiments were performed to validate the proposed handheld biosensor, which achieved a limit of detection (LOD) of 1.09 × 10−3 RIU for bulk solution measurement. The sensor’s performance in the multiplexed detection of albumin and creatinine solutions at concentrations of 0–500 μg/mL and 0–10 mg/mL, respectively, was investigated; the corresponding LODs were 0.66 and 0.61 μg/mL.


  • Open Access

    Gradient Guided-Mode Resonance Biosensor with Smartphone Readout

    by Ting-Zhou Lin, Cheng-Hao Chen, Yuan-Pei Lei, Cheng-Sheng Huang

    Integrating biosensors with smartphones is becoming an increasingly popular method for detecting various biomolecules and could replace expensive laboratory-based instruments. In this work, we demonstrate a novel smartphone-based biosensor system with a gradient grating period guided-mode resonance (GGP-GMR) sensor. The sensor comprises numerous gratings which each correspond to and block the light of a specific resonant wavelength. This results in a dark band, which is observed using a CCD underneath the GGP-GMR sensor. By monitoring the shift in the dark band, the concentration of a molecule in a sample can be determined. The sensor is illuminated by a light-emitting diode, and the light transmitted through the GGP-GMR sensor is directly captured by a smartphone, which then displays the results. Experiments were performed to validate the proposed smartphone biosensor and a limit of detection (LOD) of 1.50 × 10−3 RIU was achieved for sucrose solutions. Additionally, multiplexed detection was demonstrated for albumin and creatinine solutions at concentrations of 0–500 and 0–1 mg/mL, respectively; the corresponding LODs were 1.18 and 20.56 μg/mL.


  • Open Access

    A Compact Detection Platform Based on Gradient Guided-Mode Resonance for Colorimetric and Fluorescence Liquid Assay Detection

    by Jing-Jhong Gao, Ching-Wei Chiu, Kuo-Hsing Wen, Cheng-Sheng Huang

    This paper presents a compact spectral detection system for common fluorescent and colorimetric assays. This system includes a gradient grating period guided-mode resonance (GGP-GMR) filter and charge-coupled device. In its current form, the GGP-GMR filter, which has a size of less than 2.5 mm, can achieve a spectral detection range of 500–700 nm. Through the direct measurement of the fluorescence emission, the proposed system was demonstrated to detect both the peak wavelength and its corresponding intensity. One fluorescent assay (albumin) and two colorimetric assays (albumin and creatinine) were performed to demonstrate the practical application of the proposed system for quantifying common liquid assays. The results of our system exhibited suitable agreement with those of a commercial spectrometer in terms of the assay sensitivity and limit of detection (LOD). With the proposed system, the fluorescent albumin, colorimetric albumin, and colorimetric creatinine assays achieved LODs of 40.99 and 398 and 25.49 mg/L, respectively. For a wide selection of biomolecules in point-of-care applications, the spectral detection range achieved by the GGP-GMR filter can be further extended and the simple and compact optical path configuration can be integrated with a lab-on-a-chip system.


  • Biosensor based on two-dimensional gradient guided-mode resonance filter

    by Nien-Zu Yang, Chan-Te Hsiung, Cheng-Sheng Huang

    A novel biosensor based on a two-dimensional gradient (TDG) guided-mode resonance (GMR) filter was introduced in this study. The TDG-GMR is demarcated in terms of the gradient grating period (GGP) in one dimension and gradient waveguide thickness (GWT) in the other dimension. A single compact sensor can combine these two features to simultaneously provide a broad detection range through GGP and high resolution through GWT. A detection range of 0.109 RIU (0%–60% sucrose content) with a limit of detection of 5.62 × 10−4 was demonstrated in this study by using a TDG-GMR with a size of 140.8 × 125.4 µm2. This value cannot be achieved using one dimensional gradient GMR sensor. Label-free (LF) biomolecule detection through TDG-GMR was also experimentally demonstrated in a model assay of albumin. The result confirms that the GWT-GMR provides a better resolution, whereas the GGP-GMR provides a broader detection range. A device for multiplex measurement could be easily implemented with a compact sensor chip and a simple readout directly from a charge-coupled device. This system would require a narrow-band source such as a light emitting diode or a laser diode, in addition to a limited number of other components such as a polarizer and a collimator. The proposed TDG-GMR could easily be integrated with smartphones and portable devices.


  • Open Access

    Gradient Waveguide Thickness Guided-Mode Resonance Biosensor

    by Jia-Ming Yang, Nien-Zu Yang, Cheng-Hao Chen, Cheng-Sheng Huang

    Portable systems for detecting biomolecules have attracted considerable attention, owing to the demand for point-of-care testing applications. This has led to the development of lab-on-a-chip (LOC) devices. However, most LOCs are developed with a focus on automation and preprocessing of samples; fluorescence measurement, which requires additional off-chip detection instruments, remains the main detection method in conventional assays. By incorporating optical biosensors into LOCs, the biosensing system can be simplified and miniaturized. However, many optical sensors require an additional coupling device, such as a grating or prism, which complicates the optical path design of the system. In this study, we propose a new type of biosensor based on gradient waveguide thickness guided-mode resonance (GWT-GMR), which allows for the conversion of spectral information into spatial information such that the output signal can be recorded on a charge-coupled device for further analysis without any additional dispersive elements. A two-channel microfluidic chip with embedded GWT-GMRs was developed to detect two model assays in a buffer solution: albumin and creatinine. The results indicated that the limit of detection for albumin was 2.92 μg/mL for the concentration range of 0.8–500 μg/mL investigated in this study, and that for creatinine it was 12.05 μg/mL for the concentration range of 1–10,000 μg/mL. These results indicated that the proposed GWT-GMR sensor is suitable for use in clinical applications. Owing to its simple readout and optical path design, the GWT-GMR is considered ideal for integration with smartphones or as miniaturized displays in handheld devices, which could prove beneficial for future point-of-care applications.


  • Gradient Grating Period Guided-Mode Resonance for Potential Biosensing Applications

    by Hua-Cheng Lin, Yen-Chieh Wang, Jia-Ming Yang, Cheng-Sheng Huang, Shao-Hsuan Kuo, Bor-Ran Li

    In this study, a novel gradient grating period guided-mode resonance (GGP-GMR) biosensor is proposed, and albumin was successfully detected as a test model. The GGP-GMR sensor exhibits a gradient resonant wavelength along the device. At a fixed incident wavelength, light resonates at a specific period such that the light is reflected at this period (or resonant period) and transmitted to other periods. Thus, for a charge-coupled device under the GGP-GMR sensor, a dip-like intensity distribution was measured with a specific pixel of minimum intensity corresponding to the resonant period. The variation in sample concentrations caused changes in the refractive index (RI) on the sensor surface, which induced a shift in the resonant period and in the pixel corresponding to the minimum intensity. A GGP-GMR sensor can achieve a limit of detection of 8.58 W 10-4 RIU within a detection range of sucrose solutions of 0%–60% concentrations that corresponds to the RI from 1.333 to 1.442. In a buffer solution, albumin was successfully detected to measure the clinically relevant concentration. The simple design and easy fabrication of the GGP-GMR sensor combined with its simple readout and optical path design facilitates system miniaturization for handheld devices and its integration with smartphones, which could be beneficial for future point-of-care applications.