Javad Ghalibafan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Javad Ghalibafan has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Morteza Mohammadi Shirkolaei
Department of Electrical Engineering, Shahid Sattari Aeronautical University of Science and Technology, Tehran, Iran
5 shared publications Mohammad Hosseinzadeh
Department of Electrical Engineering, Shahrood University of Technology, Shahrud, Iran
3 shared publications- Fatemeh Dehghani2 shared publications
- Keivan Kaboutari
Instituto de Telecomunicaes and the Department de Eletrnica, Telecomunicaes e Informtica, University of Aveiro, Aveiro, Portugal
2 shared publications - Morteza Rezaee
Electrical Engineering Department, Telemetry Research Laboratory, Hakim Sabzevari University, Sabzevar, Iran
2 shared publications - Seyed Mohammad Hashemi
Faculty of Electrical Engineering, Shahid Rajaee Teacher Training University, Tehran, Iran
2 shared publications
Latest Publications
- 16 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (10) , 15172-15184
M-SRR-Based Microwave Sensor Design and Modeling for Evaluating Transformer Oil Quality and Lifespan Employing Relative Permittivity
Transformer oil serves as an essential insulating medium for high-power electrical equipment such as transformers. Its degradation can result in transformer malfunction and potential disruptions in the power distribution network. Therefore, real-time monitoring of transformer oil quality is crucial to prevent equipment failure and maintain network reliability. In this study, a Microstripline-Split Ring Resonator (M-SRR)-based microwave sensor is designed and fabricated to assess the quality of transformer oil through variations in its dielectric constant. Unlike previously reported passive sensor structures, the proposed configuration enables continuous and non-invasive monitoring of transformer oil aging, providing a viable alternative to conventional chemical analysis techniques. The simulated and experimental results of the forward transmission coefficient (S21) for the Oil Under Test (OUT) exhibit a strong correlation, confirming the validity of the proposed design. The sensor demonstrates a normalized sensitivity range of approximately -38.02 to -5.48% for oil Sample 1 and -22.47 to -5.77% for oil Sample 2, indicating its effectiveness in detecting subtle changes in the oil’s electrical properties during the degradation process. Furthermore, the loss tangent of transformer oil can be evaluated by analyzing the magnitude of the S21 parameter at the resonance frequencies, providing additional insight into the dielectric losses and overall condition of the oil.
- 16 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (10) , 15172-15184
M-SRR-Based Microwave Sensor Design and Modeling for Evaluating Transformer Oil Quality and Lifespan Employing Relative Permittivity
Transformer oil serves as an essential insulating medium for high-power electrical equipment such as transformers. Its degradation can result in transformer malfunction and potential disruptions in the power distribution network. Therefore, real-time monitoring of transformer oil quality is crucial to prevent equipment failure and maintain network reliability. In this study, a Microstripline-Split Ring Resonator (M-SRR)-based microwave sensor is designed and fabricated to assess the quality of transformer oil through variations in its dielectric constant. Unlike previously reported passive sensor structures, the proposed configuration enables continuous and non-invasive monitoring of transformer oil aging, providing a viable alternative to conventional chemical analysis techniques. The simulated and experimental results of the forward transmission coefficient (S21) for the Oil Under Test (OUT) exhibit a strong correlation, confirming the validity of the proposed design. The sensor demonstrates a normalized sensitivity range of approximately -38.02 to -5.48% for oil Sample 1 and -22.47 to -5.77% for oil Sample 2, indicating its effectiveness in detecting subtle changes in the oil’s electrical properties during the degradation process. Furthermore, the loss tangent of transformer oil can be evaluated by analyzing the magnitude of the S21 parameter at the resonance frequencies, providing additional insight into the dielectric losses and overall condition of the oil.
- Open Access
- 10 January 2025
- Published by Springer Nature in Discover Electronics
- Vol. 2 (1) , 1-8
Scrutinizing the dielectric properties of dialysis fluid for health monitoring applications
- 10 January 2025
- Published by Springer Nature in Discover Electronics
- Vol. 2 (1) , 1-8
Open AccessScrutinizing the dielectric properties of dialysis fluid for health monitoring applications
- 1 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (24) , 40774-40780
A High-Resolution Microwave Displacement Sensor Based on Interferometry in Groove Gap Waveguide Technology
This paper presents a highly sensitive microwave groove gap waveguide displacement sensor based on the interferometry technique. By using the interferometric measurement, environmental effects on sensing are reduced. In this sensor, two gap waveguide channels are provided as the measurement and reference paths. A series stub is inserted in the measurement path, creating a 180° phase difference between signals in two paths and generating a transmission zero (TZ) in the frequency response of the sensor after combining signals. By inserting a dielectric slab inside the stub, the electrical length of the stub is changed and the TZ frequency is shifted. Since the top plate of the gap waveguide does not need electrical contact with the bottom plate, attaching the dielectric slab to the moveable top plate makes the displacement sensor easily realized, and displacement can be obtained by measuring the TZ frequency. A sensor prototype is simulated and fabricated using Aluminum as metal and PTFE as dielectric. The measurement results clearly show a linear TZ frequency shift from 10.4 GHz to 11.2 GHz with a sensitivity of 100MHz/1mm.
- 1 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (24) , 40774-40780
A High-Resolution Microwave Displacement Sensor Based on Interferometry in Groove Gap Waveguide Technology
This paper presents a highly sensitive microwave groove gap waveguide displacement sensor based on the interferometry technique. By using the interferometric measurement, environmental effects on sensing are reduced. In this sensor, two gap waveguide channels are provided as the measurement and reference paths. A series stub is inserted in the measurement path, creating a 180° phase difference between signals in two paths and generating a transmission zero (TZ) in the frequency response of the sensor after combining signals. By inserting a dielectric slab inside the stub, the electrical length of the stub is changed and the TZ frequency is shifted. Since the top plate of the gap waveguide does not need electrical contact with the bottom plate, attaching the dielectric slab to the moveable top plate makes the displacement sensor easily realized, and displacement can be obtained by measuring the TZ frequency. A sensor prototype is simulated and fabricated using Aluminum as metal and PTFE as dielectric. The measurement results clearly show a linear TZ frequency shift from 10.4 GHz to 11.2 GHz with a sensitivity of 100MHz/1mm.
- 30 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (15) , 17619-17626
The EBG-Based Biosensor for Setting the Appropriate Dialysis Time in Hemodialysis Process
Microwave biosensors can be considered a non-invasive method for monitoring the water content and the waste material in the blood due to their continuous examination and real-time results. In this work, we present a novel method for setting an appropriate dialysis time, so that patients can receive better quality dialysis. The design proposes a biosensor integrated with dialysis tubes and is implemented using electromagnetic band gap structure in the ISM band. The tubes are passed from inside the pierced substrates and over the patches before and after dialysis. The sensor is used as a quality control to non-invasively monitor the amount of blood purification of hemodialysis patients using changes observed in relative permittivity of blood (58–64) by recording the transmission resonance frequency. Hence, it can be concluded that changes in blood’s dielectric properties can be detected using a biosensor. Before fabrication, the proposed sensor is simulated and confirmed via the measurement setup. The sensitivity performance is obtained to be about 0.09 and 0.06 for two resonances of f1= 1.5 GHz and f2 = 3.78 GHz, allowing for the monitoring of the waste reduction rate during dialysis. Eventually, we propose a low cost, and non-destructive microwave biosensor without sampling process, while also providing the diagnosis principles for blood clearance rate due to the dual-band performance.
- 30 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (15) , 17619-17626
The EBG-Based Biosensor for Setting the Appropriate Dialysis Time in Hemodialysis Process
Microwave biosensors can be considered a non-invasive method for monitoring the water content and the waste material in the blood due to their continuous examination and real-time results. In this work, we present a novel method for setting an appropriate dialysis time, so that patients can receive better quality dialysis. The design proposes a biosensor integrated with dialysis tubes and is implemented using electromagnetic band gap structure in the ISM band. The tubes are passed from inside the pierced substrates and over the patches before and after dialysis. The sensor is used as a quality control to non-invasively monitor the amount of blood purification of hemodialysis patients using changes observed in relative permittivity of blood (58–64) by recording the transmission resonance frequency. Hence, it can be concluded that changes in blood’s dielectric properties can be detected using a biosensor. Before fabrication, the proposed sensor is simulated and confirmed via the measurement setup. The sensitivity performance is obtained to be about 0.09 and 0.06 for two resonances of f1= 1.5 GHz and f2 = 3.78 GHz, allowing for the monitoring of the waste reduction rate during dialysis. Eventually, we propose a low cost, and non-destructive microwave biosensor without sampling process, while also providing the diagnosis principles for blood clearance rate due to the dual-band performance.
- 17 June 2023
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 34 (17) , 1-6
Avail of the glass wool properties using the aperture-coupled technique to design a thermal smart jacket
- 17 June 2023
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 34 (17) , 1-6
Avail of the glass wool properties using the aperture-coupled technique to design a thermal smart jacket
- 4 October 2021
- Published by Taylor & Francis in Waves in Random and Complex Media
- Vol. 34 (5) , 3716-3726
Magnetically scannable slotted waveguide antenna based on the ferrite with gain enhancement
In this paper, a ferrite-filled rectangular waveguide as a balanced composite right/left-handed (CRLH) transmission line is considered. Based on the surface current density of dominant mode, a centerline longitudinal slot on the broad wall of this ferrite-filled rectangular waveguide can be radiate to the free space as a leaky-wave antenna (LWA). This proposed LWA has the both capability of the fixed-bias frequency scanning and fixed-frequency bias scanning from negative to positive angles. However, the gain of the centerline slotted ferrite-filled rectangular waveguide antenna is not acceptable. By adding another slot and changing the position of slots on the broad wall, the gain is improved to more than 9 dB in frequency range of 6.59–6.69 GHz.
- 4 October 2021
- Published by Taylor & Francis in Waves in Random and Complex Media
- Vol. 34 (5) , 3716-3726
Magnetically scannable slotted waveguide antenna based on the ferrite with gain enhancement
In this paper, a ferrite-filled rectangular waveguide as a balanced composite right/left-handed (CRLH) transmission line is considered. Based on the surface current density of dominant mode, a centerline longitudinal slot on the broad wall of this ferrite-filled rectangular waveguide can be radiate to the free space as a leaky-wave antenna (LWA). This proposed LWA has the both capability of the fixed-bias frequency scanning and fixed-frequency bias scanning from negative to positive angles. However, the gain of the centerline slotted ferrite-filled rectangular waveguide antenna is not acceptable. By adding another slot and changing the position of slots on the broad wall, the gain is improved to more than 9 dB in frequency range of 6.59–6.69 GHz.
- 22 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 57 (4) , 1-10
Scannable Leaky-Wave Antenna Based on Ferrite-Blade Waveguide Operated Below the Cutoff Frequency
This article proposes a scannable leaky-wave antenna (LWA). The antenna consists of a ferrite-blade waveguide with a longitudinal slot on the upper wall, which has a tunable composite right-/left-handed (CRLH) property. The left-handed (LH) behavior of this structure is based on the negative effective permeability of the ferrite material and the negative effective permittivity of the waveguide excited below its cutoff frequency. First, based on the modal analysis and calculated dispersion relation, the unbalanced CRLH response of the ferrite-blade waveguide is investigated. Second, an LWA is presented by using a longitudinal slot on the upper wall of the proposed ferrite-blade waveguide, where the tunable balance CRLH response is achieved and analyzed by the transverse resonance method (TRM). The proposed LWA can provide backward, broadside, and forward radiations by a change in the operation frequency or the magnetic bias, independently. The given results show a +59° to −57° sweep in the radiation beam when the magnetic bias of the ferrite changed from 1400 to 1600 Oe at the sampling frequency of 6.4 GHz. Moreover, the results show that the frequency tuning range is more than 600 MHz (6.2–6.8 GHz). The peak gain and efficiency of the proposed antenna are 7.1 dBi and 78.5% at 6.6 GHz, respectively.
- 22 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 57 (4) , 1-10
Scannable Leaky-Wave Antenna Based on Ferrite-Blade Waveguide Operated Below the Cutoff Frequency
This article proposes a scannable leaky-wave antenna (LWA). The antenna consists of a ferrite-blade waveguide with a longitudinal slot on the upper wall, which has a tunable composite right-/left-handed (CRLH) property. The left-handed (LH) behavior of this structure is based on the negative effective permeability of the ferrite material and the negative effective permittivity of the waveguide excited below its cutoff frequency. First, based on the modal analysis and calculated dispersion relation, the unbalanced CRLH response of the ferrite-blade waveguide is investigated. Second, an LWA is presented by using a longitudinal slot on the upper wall of the proposed ferrite-blade waveguide, where the tunable balance CRLH response is achieved and analyzed by the transverse resonance method (TRM). The proposed LWA can provide backward, broadside, and forward radiations by a change in the operation frequency or the magnetic bias, independently. The given results show a +59° to −57° sweep in the radiation beam when the magnetic bias of the ferrite changed from 1400 to 1600 Oe at the sampling frequency of 6.4 GHz. Moreover, the results show that the frequency tuning range is more than 600 MHz (6.2–6.8 GHz). The peak gain and efficiency of the proposed antenna are 7.1 dBi and 78.5% at 6.6 GHz, respectively.
- 3 August 2020
- Published by Taylor & Francis in Waves in Random and Complex Media
- Vol. 32 (2) , 755-770
Unbalanced CRLH behavior of ferrite-loaded waveguide operated below cutoff frequency
This paper proposes a new unbalance composite right/left handed (CRLH) transmission line that consists of a normally magnetized ferrite-loaded rectangular waveguide. The left-handed (LH) behavior of this structure is based on the negative effective permeability of the ferrite material and the negative effective permittivity of the hollow metallic waveguide at the frequencies below the cutoff. By increasing the frequency and passing through the cutoff frequency, this structure behaves as a right handed (RH) transmission line. As a main advantage of the proposed structure, the CRLH response of this transmission line can be tuned by changing the magnetic bias of the ferrite layer. This tunable CRLH transmission line can be used to design a tunable microwave filter or a tunable leaky wave antenna (LWA) with backfire-to-endfire scanning capability. Compare to previous CRLH metamaterial structures, the proposed structure has an easy design and a wide frequency range of tunability.
- 3 August 2020
- Published by Taylor & Francis in Waves in Random and Complex Media
- Vol. 32 (2) , 755-770
Unbalanced CRLH behavior of ferrite-loaded waveguide operated below cutoff frequency
This paper proposes a new unbalance composite right/left handed (CRLH) transmission line that consists of a normally magnetized ferrite-loaded rectangular waveguide. The left-handed (LH) behavior of this structure is based on the negative effective permeability of the ferrite material and the negative effective permittivity of the hollow metallic waveguide at the frequencies below the cutoff. By increasing the frequency and passing through the cutoff frequency, this structure behaves as a right handed (RH) transmission line. As a main advantage of the proposed structure, the CRLH response of this transmission line can be tuned by changing the magnetic bias of the ferrite layer. This tunable CRLH transmission line can be used to design a tunable microwave filter or a tunable leaky wave antenna (LWA) with backfire-to-endfire scanning capability. Compare to previous CRLH metamaterial structures, the proposed structure has an easy design and a wide frequency range of tunability.