Bin Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Bin Zhou has a total of 123 co-authors. Here are the top co-authors by number of shared publications:
Fei Li
8 shared publicationsMei-Lan Tan
7 shared publicationsHui Ren
5 shared publicationsYang Xu
5 shared publicationsAng Wang
Department of R&D, Shandong Longertek Technology Co., Ltd, Jinan, China
4 shared publicationsHao-Yi Zhao
4 shared publications
Latest Publications
- 15 September 2026
- Published by SAGE Publications in Indoor and Built Environment
A modified model for predicting thermal sensation based on local radiant temperature incorporating solar radiation
The growing prevalence of glazed surfaces in contemporary architecture has positioned solar exposure as a critical determinant influencing occupant thermal comfort. Given the directional characteristics of solar radiation, its effects are typically localized to specific anatomical areas. To quantify this spatial variability, we introduced a local radiant temperature (LRT) metric that integrates key parameters of solar radiation. Building upon this metric, we developed two modified solar-adjusted predicted mean vote (SA-PMV) models: a local thermal sensation model (mSA-PMV L ) and a whole-body thermal sensation model (mSA-PMV O ). Experimental investigations in controlled climate environments (14 °C and 18 °C air temperatures) captured thermal responses from 20 participants exposed to simulated solar radiation intensities of 200 and 300 W/m 2 . The results demonstrate that LRT revealed pronounced thermal disparities across body segments (ΔLRT max = 22.2 °C between irradiated and non-irradiated zones) under solar exposure. Using irradiated-side LRT, mSA-PMV L achieved superior prediction accuracy for local thermal sensation. For whole-body thermal sensation, an anterior-weighted mPMV ant model by appropriately weighting LRT on irradiated sides performed best (MAE = 0.04 and RMSE = 0.05), outperforming conventional SA-PMV. The models enable dynamic adjustment of acceptable operative temperature based on solar intensity, supporting the design of adaptive facades and precision HVAC systems in highly-glazed buildings.
- 15 September 2026
- Published by SAGE Publications in Indoor and Built Environment
A modified model for predicting thermal sensation based on local radiant temperature incorporating solar radiation
The growing prevalence of glazed surfaces in contemporary architecture has positioned solar exposure as a critical determinant influencing occupant thermal comfort. Given the directional characteristics of solar radiation, its effects are typically localized to specific anatomical areas. To quantify this spatial variability, we introduced a local radiant temperature (LRT) metric that integrates key parameters of solar radiation. Building upon this metric, we developed two modified solar-adjusted predicted mean vote (SA-PMV) models: a local thermal sensation model (mSA-PMV L ) and a whole-body thermal sensation model (mSA-PMV O ). Experimental investigations in controlled climate environments (14 °C and 18 °C air temperatures) captured thermal responses from 20 participants exposed to simulated solar radiation intensities of 200 and 300 W/m 2 . The results demonstrate that LRT revealed pronounced thermal disparities across body segments (ΔLRT max = 22.2 °C between irradiated and non-irradiated zones) under solar exposure. Using irradiated-side LRT, mSA-PMV L achieved superior prediction accuracy for local thermal sensation. For whole-body thermal sensation, an anterior-weighted mPMV ant model by appropriately weighting LRT on irradiated sides performed best (MAE = 0.04 and RMSE = 0.05), outperforming conventional SA-PMV. The models enable dynamic adjustment of acceptable operative temperature based on solar intensity, supporting the design of adaptive facades and precision HVAC systems in highly-glazed buildings.
- 14 September 2026
- Published by Elsevier in Building and Environment
- Vol. 305
Pressure-constrained coordinated demand-controlled filtration strategy for environmental control in an industrial cleanroom
- 14 September 2026
- Published by Elsevier in Building and Environment
- Vol. 305
Pressure-constrained coordinated demand-controlled filtration strategy for environmental control in an industrial cleanroom
- 15 May 2026
- Published by Elsevier in Energy and Buildings
- Vol. 364
Thermal comfort of medical staff in operating rooms: a review and future perspectives
- 15 May 2026
- Published by Elsevier in Energy and Buildings
- Vol. 364
Thermal comfort of medical staff in operating rooms: a review and future perspectives
- 24 March 2026
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 35 (8) , 1283-1301
Comparative performance study of traditional unidirectional airflow and novel variable temperature and velocity air supply systems on thermal comfort of medical staff in operating room
Thermal comfort of medical staff in operating room can affect the work efficiency and have an impact on the success of surgeries. Due to the varying thermal comfort requirements of medical staff with different responsibilities, unidirectional airflow system cannot meet the thermal needs of all personnel. Therefore, a novel variable temperature and velocity air supply (VTVA) system has been introduced to investigate its impact on thermal comfort of medical staff. Since direct measurement of indoor thermal environment parameters during actual surgeries is impractical and difficult, Computational Fluid Dynamics (CFD) simulation method was adopted for this study. The distribution of thermal environment parameters and PMV-PPD indicators between unidirectional airflow and the VTVA systems were compared. It indicates that the VTVA system can create multiple thermal environment zones in the operating room, significantly improving the thermal comfort level of medical staff. When the air supply temperature on both lateral sides was within the range of 21.0–23.0°C, satisfactory thermal comfort was attained for the surgeon and the anaesthetist. CFD numerical method is an effective tool for predicting the thermal comfort of medical staff in operating room. This study provides a theoretical basis for optimizing the design of air supply systems in operating rooms.
- 24 March 2026
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 35 (8) , 1283-1301
Comparative performance study of traditional unidirectional airflow and novel variable temperature and velocity air supply systems on thermal comfort of medical staff in operating room
Thermal comfort of medical staff in operating room can affect the work efficiency and have an impact on the success of surgeries. Due to the varying thermal comfort requirements of medical staff with different responsibilities, unidirectional airflow system cannot meet the thermal needs of all personnel. Therefore, a novel variable temperature and velocity air supply (VTVA) system has been introduced to investigate its impact on thermal comfort of medical staff. Since direct measurement of indoor thermal environment parameters during actual surgeries is impractical and difficult, Computational Fluid Dynamics (CFD) simulation method was adopted for this study. The distribution of thermal environment parameters and PMV-PPD indicators between unidirectional airflow and the VTVA systems were compared. It indicates that the VTVA system can create multiple thermal environment zones in the operating room, significantly improving the thermal comfort level of medical staff. When the air supply temperature on both lateral sides was within the range of 21.0–23.0°C, satisfactory thermal comfort was attained for the surgeon and the anaesthetist. CFD numerical method is an effective tool for predicting the thermal comfort of medical staff in operating room. This study provides a theoretical basis for optimizing the design of air supply systems in operating rooms.
- 19 February 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 121
Numerical simulation of indoor particle removal by negative air ionizer through a particle enhanced deposition model
- 19 February 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 121
Numerical simulation of indoor particle removal by negative air ionizer through a particle enhanced deposition model
- 25 March 2025
- Published by Elsevier in Building and Environment
- Vol. 277
Experimental study of thermal comfort by variable temperature and velocity air supply system in operating room
- 25 March 2025
- Published by Elsevier in Building and Environment
- Vol. 277
Experimental study of thermal comfort by variable temperature and velocity air supply system in operating room
- 4 February 2025
- Published by Elsevier in Energy and Buildings
- Vol. 332
Field questionnaire survey on thermal comfort of medical personnel in operating rooms for hospitals in Nanjing
- 4 February 2025
- Published by Elsevier in Energy and Buildings
- Vol. 332
Field questionnaire survey on thermal comfort of medical personnel in operating rooms for hospitals in Nanjing
- 8 December 2024
- Published by Elsevier in Sustainable Cities and Society
- Vol. 118
Performance prediction of urban tunnel purification system based on the verified random number screening algorithm
- 8 December 2024
- Published by Elsevier in Sustainable Cities and Society
- Vol. 118
Performance prediction of urban tunnel purification system based on the verified random number screening algorithm
- 20 September 2024
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 24 (2) , 131-147
Simulation on interface airflow by occupant’s traffic flow through operating room
- 20 September 2024
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 24 (2) , 131-147
Simulation on interface airflow by occupant’s traffic flow through operating room