Farshad Kheiri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Farshad Kheiri has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
Jeff S. Haberl
2 shared publicationsJuan-Carlos Baltazar
2 shared publications
Latest Publications
- Open Access
- 10 March 2026
- Published by Avanti Publishers in International Journal of Architectural Engineering Technology
- Vol. 13 (1) , 63-83
Impact of Energy-Efficiency Retrofits on Office Building Energy Use, Emissions, and Peak Demand under Future Climate Scenarios in U.S. Climate Zones
Evaluating energy efficiency measures (EEMs) under future climate conditions is critical for climate resilient design of buildings. However, the impact of EEMs on existing buildings under projected weather conditions has been insufficiently explored. This study evaluates the energy use, peak demands, and associated emissions of a prototypical medium office buildings with typical constructions properties from 1980 to 2004 across 16 U.S. climate zones, considering different EEMs under historical (TMY3) and future climate scenarios (SSP2-4.5 and SSP5-8.5 for 2050 and 2080) to provide both location specific and broader insights. The different cases include models with envelope upgrades (wall, roof, floor, and window U-values, and solar heat gain coefficient [SHGC]), cooling coefficient of performance (COP), lighting power density (LPD), energy recovery ventilation (ERV), and combined retrofit measures, where upgrades followed ASHRAE 189.1-2020 recommendations. Results showed that the energy use and emissions under projected weather conditions increased in very hot regions and decreased in very cold regions, particularly under SSP5-8.5, reducing the gap between these extreme conditions. LPD, cooling COP, and window upgrades showed highest energy savings. LPD yielded the largest savings among individual measures, except in very cold and subarctic zones, where window retrofits outperformed. Results revealed increased stress on electric grids in regions with significant cooling loads where energy use outpaces energy savings under future scenarios. Additionally, the analysis showed that clean energy production in extreme cooling- or heating-dominated regions require attention, as the high electricity-related emissions in these regions coincide with high energy loads, amplifying the associated environmental impacts.
- 10 March 2026
- Published by Avanti Publishers in International Journal of Architectural Engineering Technology
- Vol. 13 (1) , 63-83
Open AccessImpact of Energy-Efficiency Retrofits on Office Building Energy Use, Emissions, and Peak Demand under Future Climate Scenarios in U.S. Climate Zones
Evaluating energy efficiency measures (EEMs) under future climate conditions is critical for climate resilient design of buildings. However, the impact of EEMs on existing buildings under projected weather conditions has been insufficiently explored. This study evaluates the energy use, peak demands, and associated emissions of a prototypical medium office buildings with typical constructions properties from 1980 to 2004 across 16 U.S. climate zones, considering different EEMs under historical (TMY3) and future climate scenarios (SSP2-4.5 and SSP5-8.5 for 2050 and 2080) to provide both location specific and broader insights. The different cases include models with envelope upgrades (wall, roof, floor, and window U-values, and solar heat gain coefficient [SHGC]), cooling coefficient of performance (COP), lighting power density (LPD), energy recovery ventilation (ERV), and combined retrofit measures, where upgrades followed ASHRAE 189.1-2020 recommendations. Results showed that the energy use and emissions under projected weather conditions increased in very hot regions and decreased in very cold regions, particularly under SSP5-8.5, reducing the gap between these extreme conditions. LPD, cooling COP, and window upgrades showed highest energy savings. LPD yielded the largest savings among individual measures, except in very cold and subarctic zones, where window retrofits outperformed. Results revealed increased stress on electric grids in regions with significant cooling loads where energy use outpaces energy savings under future scenarios. Additionally, the analysis showed that clean energy production in extreme cooling- or heating-dominated regions require attention, as the high electricity-related emissions in these regions coincide with high energy loads, amplifying the associated environmental impacts.
- 5 April 2023
- Published by Elsevier in Energy and Buildings
- Vol. 289
Split-degree day method: A novel degree day method for improving building energy performance estimation
- 5 April 2023
- Published by Elsevier in Energy and Buildings
- Vol. 289
Split-degree day method: A novel degree day method for improving building energy performance estimation
- 1 September 2020
- Published by Elsevier in Solar Energy
- Vol. 208, 814-829
A multistage recursive approach in time- and frequency-domain for thermal analysis of thermochromic glazing and thermostatic control systems in buildings
- 1 September 2020
- Published by Elsevier in Solar Energy
- Vol. 208, 814-829
A multistage recursive approach in time- and frequency-domain for thermal analysis of thermochromic glazing and thermostatic control systems in buildings
- 17 November 2019
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 30 (2) , 195-214
Optimization of building fenestration and shading for climate-based daylight performance using the coupled genetic algorithm and simulated annealing optimization methods
Various metaheuristic optimization methods have been applied in high-performance glazing and shading system design due to the complexity and nonlinear impact of the fenestration characteristics on the daylighting performance. However, the optimal solutions found by different optimization methods may vary because of the stochastic nature and the configurations of the optimization methods. This paper studied the improvements in the reliability, consistency and robustness of the genetic algorithm (GA) using hybridization with simulated annealing (SA) considering different cooling strategies in the SA, including the initial temperature and state transitions for each temperature, which controls the comprehensiveness and the convergence acceleration of the search by SA. Analysis of the reliability, consistency and robustness of the optimization methods based on the mean values and the variances of the objective function values of the best cases found in different methods revealed that there is a significant difference between the hybrid GA/SA with higher temperature and GA, where hybrid algorithm performed better than the GA.
- 17 November 2019
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 30 (2) , 195-214
Optimization of building fenestration and shading for climate-based daylight performance using the coupled genetic algorithm and simulated annealing optimization methods
Various metaheuristic optimization methods have been applied in high-performance glazing and shading system design due to the complexity and nonlinear impact of the fenestration characteristics on the daylighting performance. However, the optimal solutions found by different optimization methods may vary because of the stochastic nature and the configurations of the optimization methods. This paper studied the improvements in the reliability, consistency and robustness of the genetic algorithm (GA) using hybridization with simulated annealing (SA) considering different cooling strategies in the SA, including the initial temperature and state transitions for each temperature, which controls the comprehensiveness and the convergence acceleration of the search by SA. Analysis of the reliability, consistency and robustness of the optimization methods based on the mean values and the variances of the objective function values of the best cases found in different methods revealed that there is a significant difference between the hybrid GA/SA with higher temperature and GA, where hybrid algorithm performed better than the GA.