Valiallah Saba
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Valiallah Saba has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Seyed Navid Resalat
Control and Intelligent Processing Center of Excellence, School of Electrical and Computer Engineering, University of Tehran, Tehran, Iran
5 shared publications- Seyed Amir Hossein Batouli
Department of Neuroscience and Addiction Studies, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran
3 shared publications Babak Khodaie
2 shared publicationsFardin Afdideh
Tehran, Iran
2 shared publicationsSaeed Setayeshi
Department of Nuclear Engineering and Physics, Amirkabir University of Technology, Tehran, Iran
2 shared publicationsAbdollah Valizadeh
Faculty of Paramedicine, Radiology Department, Aja University of Medical Sciences, Tehran, Iran
1 shared publication
Latest Publications
- 21 November 2025
- Published by Elsevier in Acta Psychologica
- Vol. 261, 105982
Corrigendum to “How martial arts training affects psychological states and brain function and structure: An fMRI study” [Acta Psychologica 261 (2025) 105865]
- 21 November 2025
- Published by Elsevier in Acta Psychologica
- Vol. 261, 105982
Corrigendum to “How martial arts training affects psychological states and brain function and structure: An fMRI study” [Acta Psychologica 261 (2025) 105865]
- Open Access
- 2 November 2025
- Published by Elsevier in Acta Psychologica
- Vol. 261, 105865
How martial arts training affects psychological states and brain function and structure: An fMRI study
- 2 November 2025
- Published by Elsevier in Acta Psychologica
- Vol. 261, 105865
Open AccessHow martial arts training affects psychological states and brain function and structure: An fMRI study
- 12 October 2023
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 43 (4) , 041503
Assessment of the effectiveness of Saba shielding with the composition of Cu–Bi in neck CT imaging: a phantom and patient study
The use of computed tomography (CT) is a very well-established medical diagnostic imaging modality, however, the high radiation dose due to this imaging method is a major concern. Therefore, dose reduction methods are necessary, especially for superficial radiosensitive organs like the thyroid. The aim of this study is to construct and assess a CT shield with composition of 90% Cu and 10% Bi (Saba shield) with regard to dose reduction and image quality. The efficiency of the constructed shields for dose reduction was assessed by measuring entrance skin dose (ESD), using thermoluminescence dosimeters placed on an anthropomorphic phantom. Image quality was assessed quantitatively based on image noise and CT number accuracy by drawing regions of interest on CT images of the anthropomorphic phantom. Image quality was further investigated qualitatively in a patient study. Application of the Saba shield and 100% Bi shield with the thickness of one thickness (1T) reduced ESD by 50.2% and 51.7%, respectively, and using a three-fold thickness reduced ESD by 64.6% and 65.1%, respectively. Saba shield with thickness of 1T had no significant change in image noise in the anterior part, and image noise and mean CT number in the posterior part (P > 0.05). The statistical analysis performed did not find any meaningful difference between the study and control groups in image quality assessment of the patient study (P > 0.05). The 1T Saba shield reduced thyroid dose efficiently during neck CT imaging without causing unwanted effects on image quality.
- 12 October 2023
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 43 (4) , 041503
Assessment of the effectiveness of Saba shielding with the composition of Cu–Bi in neck CT imaging: a phantom and patient study
The use of computed tomography (CT) is a very well-established medical diagnostic imaging modality, however, the high radiation dose due to this imaging method is a major concern. Therefore, dose reduction methods are necessary, especially for superficial radiosensitive organs like the thyroid. The aim of this study is to construct and assess a CT shield with composition of 90% Cu and 10% Bi (Saba shield) with regard to dose reduction and image quality. The efficiency of the constructed shields for dose reduction was assessed by measuring entrance skin dose (ESD), using thermoluminescence dosimeters placed on an anthropomorphic phantom. Image quality was assessed quantitatively based on image noise and CT number accuracy by drawing regions of interest on CT images of the anthropomorphic phantom. Image quality was further investigated qualitatively in a patient study. Application of the Saba shield and 100% Bi shield with the thickness of one thickness (1T) reduced ESD by 50.2% and 51.7%, respectively, and using a three-fold thickness reduced ESD by 64.6% and 65.1%, respectively. Saba shield with thickness of 1T had no significant change in image noise in the anterior part, and image noise and mean CT number in the posterior part (P > 0.05). The statistical analysis performed did not find any meaningful difference between the study and control groups in image quality assessment of the patient study (P > 0.05). The 1T Saba shield reduced thyroid dose efficiently during neck CT imaging without causing unwanted effects on image quality.
- 10 November 2021
- Published by EDP Sciences in Radioprotection
- Vol. 57 (1) , 41-48
Radiation protection to patients in radiology: A review study
The present paper aims at reviewing different shielding methods used for patients in medical imaging and investigating their merits and demerits. These techniques are generally classified into two groups including in-plane and out-of-plane shielding. Bismuth (Bi) shielding is a conventional in-plane shielding method used during CT examinations to protect radiosensitive organs. This method has reduced radiosensitive organs dose by about 34–68% during different CT examinations. However, it causes considerable degrading effects on image quality and for this reason AAPM recommended against its application in 2017. Recently, another in-plane shielding, named Saba shielding, introduced wherein all the shortcomings and deficits of Bi shielding have been resolved or fixed. Saba shielding reduces radiosensitive organs dose by about 50% without degrading image quality. Out-of-plane shields can decrease the patient dose by more than 55%. However, due to the low dose of the scattered radiation received by out-of-plane organs, in the case of applying out-of-plane shields such as gonad or thyroid shields, the risk and benefit of their usage should be evaluated.
- 10 November 2021
- Published by EDP Sciences in Radioprotection
- Vol. 57 (1) , 41-48
Radiation protection to patients in radiology: A review study
The present paper aims at reviewing different shielding methods used for patients in medical imaging and investigating their merits and demerits. These techniques are generally classified into two groups including in-plane and out-of-plane shielding. Bismuth (Bi) shielding is a conventional in-plane shielding method used during CT examinations to protect radiosensitive organs. This method has reduced radiosensitive organs dose by about 34–68% during different CT examinations. However, it causes considerable degrading effects on image quality and for this reason AAPM recommended against its application in 2017. Recently, another in-plane shielding, named Saba shielding, introduced wherein all the shortcomings and deficits of Bi shielding have been resolved or fixed. Saba shielding reduces radiosensitive organs dose by about 50% without degrading image quality. Out-of-plane shields can decrease the patient dose by more than 55%. However, due to the low dose of the scattered radiation received by out-of-plane organs, in the case of applying out-of-plane shields such as gonad or thyroid shields, the risk and benefit of their usage should be evaluated.
- 1 September 2020
- Published by Negah Scientific Publisher in Basic and Clinical Neuroscience Journal
- Vol. 11 (5) , 669-686
Larger Volume and Different Activation of the Brain in Response to Threat in Military Officers
Introduction: Military missions involve stressful and life-threatening situations; however, soldiers should have a healthy cognition on the battlefield despite their high-stress levels. This is an ability that should be gained during prior military training. Successful and influential training is suggested to be associated with structural and functional improvements of the brain. Methods: This study investigated the pattern of brain activation while observing videos relevant to life-threatening situations, in addition to brain structure. Accordingly, the obtained data were compared between 20 military members and 26 healthy controls. The study participants were all male, aged between 19 to 24 years, right-handed, studying BSc, and from the same socioeconomic status. Results: The obtained data presented a larger volume in a total number of 1103 voxels of the brain (in 5 brain areas) in the military group. Furthermore, the military group suggested higher brain activation in the visual processing areas of the brain when observing real combat videos; however, this increment was mostly in the areas associated with motor processing and executive functions in the controls. Conclusion: This study indicated that military training is associated with positive structural changes in the brain. Besides, it provided a different brain activation in response to stressful situations. These findings highlighted the importance of qualified military training.
- 1 September 2020
- Published by Negah Scientific Publisher in Basic and Clinical Neuroscience Journal
- Vol. 11 (5) , 669-686
Larger Volume and Different Activation of the Brain in Response to Threat in Military Officers
Introduction: Military missions involve stressful and life-threatening situations; however, soldiers should have a healthy cognition on the battlefield despite their high-stress levels. This is an ability that should be gained during prior military training. Successful and influential training is suggested to be associated with structural and functional improvements of the brain. Methods: This study investigated the pattern of brain activation while observing videos relevant to life-threatening situations, in addition to brain structure. Accordingly, the obtained data were compared between 20 military members and 26 healthy controls. The study participants were all male, aged between 19 to 24 years, right-handed, studying BSc, and from the same socioeconomic status. Results: The obtained data presented a larger volume in a total number of 1103 voxels of the brain (in 5 brain areas) in the military group. Furthermore, the military group suggested higher brain activation in the visual processing areas of the brain when observing real combat videos; however, this increment was mostly in the areas associated with motor processing and executive functions in the controls. Conclusion: This study indicated that military training is associated with positive structural changes in the brain. Besides, it provided a different brain activation in response to stressful situations. These findings highlighted the importance of qualified military training.
- 1 September 2020
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 191 (3) , 349-360
REDUCING ABSORBED DOSE TO THYROID IN NECK CT EXAMINATIONS: THE EFFECTS OF SABA SHIELDING
Bi shielding has been used for the protection of radiosensitive organs during computed tomography (CT) for 20 years. In 2017, American Association of Physicists in Medicine recommended against Bi shielding due to its degrading effects on image quality. Saba shielding introduced recently protecting organs as Bi shielding without degrading image quality. In this study, the Saba shield was modified and primary radiation attenuation values of the shields and entrance skin dose (ESD) on the thyroid were measured with and without shielding. Furthermore, the quality of images obtained using Saba shielding was investigated quantitatively and qualitatively. Saba and Bi shielding reduced the ESD on the thyroid by about 50%. Saba shielding had about 5–7 HU less noise and about 51–65 HU less CT numbers shift in comparison with Bi shielding at a distance of 1 cm from the shields. Saba shielding had no degrading effects on image quality in the patient study.
- 1 September 2020
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 191 (3) , 349-360
REDUCING ABSORBED DOSE TO THYROID IN NECK CT EXAMINATIONS: THE EFFECTS OF SABA SHIELDING
Bi shielding has been used for the protection of radiosensitive organs during computed tomography (CT) for 20 years. In 2017, American Association of Physicists in Medicine recommended against Bi shielding due to its degrading effects on image quality. Saba shielding introduced recently protecting organs as Bi shielding without degrading image quality. In this study, the Saba shield was modified and primary radiation attenuation values of the shields and entrance skin dose (ESD) on the thyroid were measured with and without shielding. Furthermore, the quality of images obtained using Saba shielding was investigated quantitatively and qualitatively. Saba and Bi shielding reduced the ESD on the thyroid by about 50%. Saba shielding had about 5–7 HU less noise and about 51–65 HU less CT numbers shift in comparison with Bi shielding at a distance of 1 cm from the shields. Saba shielding had no degrading effects on image quality in the patient study.
- Open Access
- 1 September 2020
- Published by Negah Scientific Publisher in Basic and Clinical Neuroscience Journal
- Vol. 11 (5) , 669-686
Larger Volume and Different Activation of the Brain in Response to Threat in Military Officers
Introduction: Military missions involve stressful and life-threatening situations; however, soldiers should have a healthy cognition on the battlefield despite their high-stress levels. This is an ability that should be gained during prior military training. Successful and influential training is suggested to be associated with structural and functional improvements of the brain. Methods: This study investigated the pattern of brain activation while observing videos relevant to life-threatening situations, in addition to brain structure. Accordingly, the obtained data were compared between 20 military members and 26 healthy controls. The study participants were all male, aged between 19 to 24 years, right-handed, studying BSc, and from the same socioeconomic status. Results: The obtained data presented a larger volume in a total number of 1103 voxels of the brain (in 5 brain areas) in the military group. Furthermore, the military group suggested higher brain activation in the visual processing areas of the brain when observing real combat videos; however, this increment was mostly in the areas associated with motor processing and executive functions in the controls. Conclusion: This study indicated that military training is associated with positive structural changes in the brain. Besides, it provided a different brain activation in response to stressful situations. These findings highlighted the importance of qualified military training.
- 1 September 2020
- Published by Negah Scientific Publisher in Basic and Clinical Neuroscience Journal
- Vol. 11 (5) , 669-686
Open AccessLarger Volume and Different Activation of the Brain in Response to Threat in Military Officers
Introduction: Military missions involve stressful and life-threatening situations; however, soldiers should have a healthy cognition on the battlefield despite their high-stress levels. This is an ability that should be gained during prior military training. Successful and influential training is suggested to be associated with structural and functional improvements of the brain. Methods: This study investigated the pattern of brain activation while observing videos relevant to life-threatening situations, in addition to brain structure. Accordingly, the obtained data were compared between 20 military members and 26 healthy controls. The study participants were all male, aged between 19 to 24 years, right-handed, studying BSc, and from the same socioeconomic status. Results: The obtained data presented a larger volume in a total number of 1103 voxels of the brain (in 5 brain areas) in the military group. Furthermore, the military group suggested higher brain activation in the visual processing areas of the brain when observing real combat videos; however, this increment was mostly in the areas associated with motor processing and executive functions in the controls. Conclusion: This study indicated that military training is associated with positive structural changes in the brain. Besides, it provided a different brain activation in response to stressful situations. These findings highlighted the importance of qualified military training.
- Open Access
- 1 July 2020
- Vol. 10 (4) , 398-406
Grape seed extract alleviates radiation-induced damages in human blood lymphocytes
Objective: Ionizing radiation induces deleterious effects in the biological systems by producing free radicals. Grape Seed Extract (GSE) as a free radical scavenger could protect the body against the damages. Materials and Methods: In this study, 12 healthy male volunteers were divided into Groups 1, 2, 3 and 4 and received 100, 300, 600 and 1000 mg GSE, respectively. Peripheral blood samples were collected from each volunteer 15 min before, and 1, 2, and 5 hr after GSE oral administration. Blood samples were then irradiated with 150 cGy of 100 kvp X-ray (Irradiated control group, was treated with only 1.5 Gy of X-rays). Cytogenic damages were detected by micronucleus assay. Results: Results showed that irradiation significantly increased the incidence of micronuclei (p<0. 001). In group 1, the mean reduction of micronucleus rate was 26.53%, 34.92%, and 31.38%, 1, 2, and 5 hr after GSE ingestion (p<0.001), respectively; this variable in group 2 was 17.38, 38.33, and 31.38 (p<0.001), in group 3, was 35.65%, 46%, and 37.15% (p<0.001), respectively and in group 4, was 41.35%, 51.73%, and 50.55% (p<0.0001), respectively. The samples collected 1, 2, and 5 hr after ingestion of GSE exhibited a significant decrease in the incidence of micronuclei compared with the radiation control group. The maximum protection and reduction in frequency of micronuclei (51.73%) was observed 2 hr after ingestion of 1000 mg GSE. Conclusion: Consumption of GSE before undergoing radiation protects human lymphocytes against X-rays by reducing radiation-induced genotoxicity.
- 1 July 2020
- Vol. 10 (4) , 398-406
Open AccessGrape seed extract alleviates radiation-induced damages in human blood lymphocytes
Objective: Ionizing radiation induces deleterious effects in the biological systems by producing free radicals. Grape Seed Extract (GSE) as a free radical scavenger could protect the body against the damages. Materials and Methods: In this study, 12 healthy male volunteers were divided into Groups 1, 2, 3 and 4 and received 100, 300, 600 and 1000 mg GSE, respectively. Peripheral blood samples were collected from each volunteer 15 min before, and 1, 2, and 5 hr after GSE oral administration. Blood samples were then irradiated with 150 cGy of 100 kvp X-ray (Irradiated control group, was treated with only 1.5 Gy of X-rays). Cytogenic damages were detected by micronucleus assay. Results: Results showed that irradiation significantly increased the incidence of micronuclei (p<0. 001). In group 1, the mean reduction of micronucleus rate was 26.53%, 34.92%, and 31.38%, 1, 2, and 5 hr after GSE ingestion (p<0.001), respectively; this variable in group 2 was 17.38, 38.33, and 31.38 (p<0.001), in group 3, was 35.65%, 46%, and 37.15% (p<0.001), respectively and in group 4, was 41.35%, 51.73%, and 50.55% (p<0.0001), respectively. The samples collected 1, 2, and 5 hr after ingestion of GSE exhibited a significant decrease in the incidence of micronuclei compared with the radiation control group. The maximum protection and reduction in frequency of micronuclei (51.73%) was observed 2 hr after ingestion of 1000 mg GSE. Conclusion: Consumption of GSE before undergoing radiation protects human lymphocytes against X-rays by reducing radiation-induced genotoxicity.
- 10 April 2020
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. -1 (ahead-of-p) , 507-520
A nonlinear dynamical approach to analysis of emotions using EEG signals based on the Poincaré map function and recurrence plots
Dynamic variations of electroencephalogram (EEG) contain significant information in the study of human emotional states. Transient time methods are well suited to evaluate short-term dynamic changes in brain activity. Human affective states, however, can be more appropriately analyzed using chaotic dynamical techniques, in which temporal variations are considered over longer durations. In this study, we have applied two different recurrence-based chaotic schemes, namely the Poincaré map function and recurrence plots (RPs), to analyze the long-term dynamics of EEG signals associated with state space (SS) trajectory of the time series. Both approaches determine the system dynamics based on the Poincaré recurrence theorem as well as the trajectory divergence producing two-dimensional (2D) characteristic plots. The performance of the methods is compared with regard to their ability to distinguish between levels of valence, arousal, dominance and liking using EEG data from the “dataset for emotion analysis using physiological” database. The differences between the levels of emotional feelings were investigated based on the analysis of variance (ANOVA) test and Spearman’s statistics. The results obtained from the RP features distinguish between the emotional ratings with a higher level of statistical significance as compared with those produced by the Poincaré map function. The scheme based on RPs was particularly advantageous in identifying the levels of dominance. Out of the 32 EEG electrodes examined, the RP-based approach distinguished the dominance levels in 23 electrodes, while the approach based on the Poincaré map function was only able to discriminate dominance levels in five electrodes. Furthermore, based on nonlinear analysis, significant correlations were observed over a wider area of the cortex for all affective states as compared with that reported based on the analysis of EEG power bands.
- 10 April 2020
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. -1 (ahead-of-p) , 507-520
A nonlinear dynamical approach to analysis of emotions using EEG signals based on the Poincaré map function and recurrence plots
Dynamic variations of electroencephalogram (EEG) contain significant information in the study of human emotional states. Transient time methods are well suited to evaluate short-term dynamic changes in brain activity. Human affective states, however, can be more appropriately analyzed using chaotic dynamical techniques, in which temporal variations are considered over longer durations. In this study, we have applied two different recurrence-based chaotic schemes, namely the Poincaré map function and recurrence plots (RPs), to analyze the long-term dynamics of EEG signals associated with state space (SS) trajectory of the time series. Both approaches determine the system dynamics based on the Poincaré recurrence theorem as well as the trajectory divergence producing two-dimensional (2D) characteristic plots. The performance of the methods is compared with regard to their ability to distinguish between levels of valence, arousal, dominance and liking using EEG data from the “dataset for emotion analysis using physiological” database. The differences between the levels of emotional feelings were investigated based on the analysis of variance (ANOVA) test and Spearman’s statistics. The results obtained from the RP features distinguish between the emotional ratings with a higher level of statistical significance as compared with those produced by the Poincaré map function. The scheme based on RPs was particularly advantageous in identifying the levels of dominance. Out of the 32 EEG electrodes examined, the RP-based approach distinguished the dominance levels in 23 electrodes, while the approach based on the Poincaré map function was only able to discriminate dominance levels in five electrodes. Furthermore, based on nonlinear analysis, significant correlations were observed over a wider area of the cortex for all affective states as compared with that reported based on the analysis of EEG power bands.
- 1 September 2019
- Published by Elsevier in Physica Medica
- Vol. 65, 238-246
Targeted radiation energy modulation using Saba shielding reduces breast dose without degrading image quality during thoracic CT examinations
- 1 September 2019
- Published by Elsevier in Physica Medica
- Vol. 65, 238-246
Targeted radiation energy modulation using Saba shielding reduces breast dose without degrading image quality during thoracic CT examinations