Andrew Liteplo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andrew Liteplo has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
- Hamid Shokoohi
Department of Emergency Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
9 shared publications Jessica Schleifer
Department of Anesthesia, Critical Care and Emergency Medicine, University Hospital Bonn, Bonn, Germany
4 shared publications- Sigmund J. Kharasch
Assistant Professor of Pediatrics, Harvard Medical School. Massachusetts General Hospital, Department of Emergency Medicine. Director, Pediatric Emergency Ultrasound, Division of Emergency Ultrasound. Boston, MA
4 shared publications - Calvin Huang
Department of Emergency Medicine, Massachusetts General Hospital, Boston, Massachusetts, USA
3 shared publications Hamid Shokoohi
Massachusetts General Hospital
3 shared publications- Andrew Goldsmith
Department of Emergency Medicine, Lahey Hospital, Burlington, USA
2 shared publications
Latest Publications
- Open Access
- 4 May 2026
- Published by Springer Nature in Cureus
- Vol. 18 (5) , e108252
Point-of-Care Ultrasound Education and Use in Conflict Settings: Lessons From the War in Ukraine
Introduction Point-of-care ultrasound (POCUS) has a well-established role in acute medical care and is particularly valuable in conflict zones where access to advanced imaging is limited. To aid Ukrainian healthcare providers, POCUS courses were implemented, and doctors received education and ultrasound probes to use on the frontlines. The objectives of this study were to evaluate the use of POCUS by novice users in conflict-related medical environments, using the war in Ukraine as a case study. We sought to identify how and where medical personnel use ultrasound after an introductory POCUS course, and what barriers to use exist. Methods This was a cross-sectional survey of former participants in two-day POCUS training courses organized by Razom for Ukraine and the Christian Medical Association of Ukraine between January 2023 and September 2024. Applications taught included Focused Assessment with Sonography for Trauma (FAST), cardiac, lung, deep vein thrombosis (DVT), soft tissue, renal, hepatobiliary, soft tissue, nerve blocks, vascular access, musculoskeletal, and ocular. All course participants were medical personnel managing soldiers injured in battle. A link to the survey was distributed by Telegram, a messaging platform. Participation was voluntary and anonymous. This research was deemed to be exempt by the Institutional Review Board (IRB). Results The survey was sent to 352 participants. A total of 40% (140/352) of participants responded, of which 87% (122/140) were doctors. Participants worked in stabilization points (56%, 78/140), in military hospitals (31%, 43/140), and in medical transport (14%, 19/140). A total of 64% (89/140) used POCUS at least once a day. The most commonly used applications were FAST (89%, 124/140), pneumothorax (72%, 101/140), vascular access (62%, 87/140), soft tissue (54%, 75/140), and nerve blocks (44%, 62/140). The most common educational barriers to use were image interpretation (47%, 66/140) and image acquisition (31%, 44/140). The most common technological problems were damage to the probe or cord (36%, 50/140), a short battery lifespan (32%, 45/140), and not having access to a machine (26%, 36/140). Conclusions After a brief training, novice users regularly used POCUS in the care of wounded soldiers in Ukraine. FAST, pneumothorax, vascular access, soft tissue, and nerve blocks were the most frequently used applications. Future efforts should focus on additional education on image interpretation and acquisition, and on procurement of more ultrasound machines.
- 4 May 2026
- Published by Springer Nature in Cureus
- Vol. 18 (5) , e108252
Open AccessPoint-of-Care Ultrasound Education and Use in Conflict Settings: Lessons From the War in Ukraine
Introduction Point-of-care ultrasound (POCUS) has a well-established role in acute medical care and is particularly valuable in conflict zones where access to advanced imaging is limited. To aid Ukrainian healthcare providers, POCUS courses were implemented, and doctors received education and ultrasound probes to use on the frontlines. The objectives of this study were to evaluate the use of POCUS by novice users in conflict-related medical environments, using the war in Ukraine as a case study. We sought to identify how and where medical personnel use ultrasound after an introductory POCUS course, and what barriers to use exist. Methods This was a cross-sectional survey of former participants in two-day POCUS training courses organized by Razom for Ukraine and the Christian Medical Association of Ukraine between January 2023 and September 2024. Applications taught included Focused Assessment with Sonography for Trauma (FAST), cardiac, lung, deep vein thrombosis (DVT), soft tissue, renal, hepatobiliary, soft tissue, nerve blocks, vascular access, musculoskeletal, and ocular. All course participants were medical personnel managing soldiers injured in battle. A link to the survey was distributed by Telegram, a messaging platform. Participation was voluntary and anonymous. This research was deemed to be exempt by the Institutional Review Board (IRB). Results The survey was sent to 352 participants. A total of 40% (140/352) of participants responded, of which 87% (122/140) were doctors. Participants worked in stabilization points (56%, 78/140), in military hospitals (31%, 43/140), and in medical transport (14%, 19/140). A total of 64% (89/140) used POCUS at least once a day. The most commonly used applications were FAST (89%, 124/140), pneumothorax (72%, 101/140), vascular access (62%, 87/140), soft tissue (54%, 75/140), and nerve blocks (44%, 62/140). The most common educational barriers to use were image interpretation (47%, 66/140) and image acquisition (31%, 44/140). The most common technological problems were damage to the probe or cord (36%, 50/140), a short battery lifespan (32%, 45/140), and not having access to a machine (26%, 36/140). Conclusions After a brief training, novice users regularly used POCUS in the care of wounded soldiers in Ukraine. FAST, pneumothorax, vascular access, soft tissue, and nerve blocks were the most frequently used applications. Future efforts should focus on additional education on image interpretation and acquisition, and on procurement of more ultrasound machines.
- Open Access
- 27 November 2023
- Published by Queen's University Library in POCUS Journal
- Vol. 8 (2) , 175-183
Handheld Lung Ultrasound to Detect COVID-19 Pneumonia in Inpatients: A Prospective Cohort Study
Background: Chest imaging, including chest X-ray (CXR) and computed tomography (CT), can be a helpful adjunct to nucleic acid test (NAT) in the diagnosis and management of Coronavirus Disease 2019 (COVID-19). Lung point of care ultrasound (POCUS), particularly with handheld devices, is an imaging alternative that is rapid, highly portable, and more accessible in low-resource settings. A standardized POCUS scanning protocol has been proposed to assess the severity of COVID-19 pneumonia, but it has not been sufficiently validated to assess diagnostic accuracy for COVID-19 pneumonia. Purpose: To assess the diagnostic performance of a standardized lung POCUS protocol using a handheld POCUS device to detect patients with either a positive NAT or a COVID-19-typical pattern on CT scan. Methods: Adult inpatients with confirmed or suspected COVID-19 and a recent CT were recruited from April to July 2020. Twelve lung zones were scanned with a handheld POCUS machine. Images were reviewed independently by blinded experts and scored according to the proposed protocol. Patients were divided into low, intermediate, and high suspicion based on their POCUS score. Results: Of 79 subjects, 26.6% had a positive NAT and 31.6% had a typical CT pattern. The receiver operator curve for POCUS had an area under the curve (AUC) of 0.787 for positive NAT and 0.820 for a typical CT. Using a two-point cutoff system, POCUS had a sensitivity of 0.90 and 1.00 compared to NAT and typical CT pattern, respectively, at the lower cutoff; it had a specificity of 0.90 and 0.89 compared to NAT and typical CT pattern at the higher cutoff, respectively. Conclusions: The proposed lung POCUS protocol with a handheld device showed reasonable diagnostic performance to detect inpatients with a positive NAT or typical CT pattern for COVID-19. Particularly in low-resource settings, POCUS with handheld devices may serve as a helpful adjunct for persons under investigation for COVID-19 pneumonia.
- 27 November 2023
- Published by Queen's University Library in POCUS Journal
- Vol. 8 (2) , 175-183
Open AccessHandheld Lung Ultrasound to Detect COVID-19 Pneumonia in Inpatients: A Prospective Cohort Study
Background: Chest imaging, including chest X-ray (CXR) and computed tomography (CT), can be a helpful adjunct to nucleic acid test (NAT) in the diagnosis and management of Coronavirus Disease 2019 (COVID-19). Lung point of care ultrasound (POCUS), particularly with handheld devices, is an imaging alternative that is rapid, highly portable, and more accessible in low-resource settings. A standardized POCUS scanning protocol has been proposed to assess the severity of COVID-19 pneumonia, but it has not been sufficiently validated to assess diagnostic accuracy for COVID-19 pneumonia. Purpose: To assess the diagnostic performance of a standardized lung POCUS protocol using a handheld POCUS device to detect patients with either a positive NAT or a COVID-19-typical pattern on CT scan. Methods: Adult inpatients with confirmed or suspected COVID-19 and a recent CT were recruited from April to July 2020. Twelve lung zones were scanned with a handheld POCUS machine. Images were reviewed independently by blinded experts and scored according to the proposed protocol. Patients were divided into low, intermediate, and high suspicion based on their POCUS score. Results: Of 79 subjects, 26.6% had a positive NAT and 31.6% had a typical CT pattern. The receiver operator curve for POCUS had an area under the curve (AUC) of 0.787 for positive NAT and 0.820 for a typical CT. Using a two-point cutoff system, POCUS had a sensitivity of 0.90 and 1.00 compared to NAT and typical CT pattern, respectively, at the lower cutoff; it had a specificity of 0.90 and 0.89 compared to NAT and typical CT pattern at the higher cutoff, respectively. Conclusions: The proposed lung POCUS protocol with a handheld device showed reasonable diagnostic performance to detect inpatients with a positive NAT or typical CT pattern for COVID-19. Particularly in low-resource settings, POCUS with handheld devices may serve as a helpful adjunct for persons under investigation for COVID-19 pneumonia.
- 20 February 2022
- Published by Wiley in Academic Emergency Medicine
- Vol. 29 (7) , 824-834
Point‐of‐care ultrasound‐first for the evaluation of small bowel obstruction: National cost savings, length of stay reduction, and preventable radiation exposure
Objectives: Computed tomography (CT) has long been the gold standard in diagnosing patients with suspected small bowel obstruction (SBO). Recently, point‐of‐care ultrasound (POCUS) has demonstrated comparable test characteristics to CT imaging for the diagnosis of SBO. Our primary objective was to estimate the annual national cost saving impact of a POCUS‐first approach for the evaluation of SBO. Our secondary objectives were to estimate the reduction in radiation exposure and emergency department (ED) length of stay (LOS).Methods: We created and ran 1000 trials of a Monte Carlo simulation. The study population included all patients presenting to the ED with abdominal pain who were diagnosed with SBO. Using this simulation, we modeled the national annual cost savings in averted advanced imaging from a POCUS‐first approach for SBO. The model assumes that all patients who require surgery or have non‐diagnostic POCUS exams undergo CT imaging. The model also conservatively assumes that a subset of patients with diagnostic POCUS exams undergo additional confirmatory CT imaging. We used the same Monte Carlo model to estimate the reduction in radiation exposure and total ED bed hours saved.Results: A POCUS‐first approach for diagnosing SBO was estimated to save a mean (±SD) of $30.1 million (±8.9 million) by avoiding 143,000 (±31,000) CT scans. This resulted in a national cumulative decrease of 507,000 bed hours (±268,000) in ED LOS. The reduction in radiation exposure to patients could potentially prevent 195 (±56) excess annual cancer cases and 98 (±28) excess annual cancer deaths.Conclusions: If adopted widely and used consistently, a POCUS‐first algorithm for SBO could yield substantial national cost savings by averting advanced imaging, decreasing ED LOS, and reducing unnecessary radiation exposure in patients. Clinical decision tools are needed to better identify which patients would most benefit from CT imaging for SBO in the ED.
- 20 February 2022
- Published by Wiley in Academic Emergency Medicine
- Vol. 29 (7) , 824-834
Point‐of‐care ultrasound‐first for the evaluation of small bowel obstruction: National cost savings, length of stay reduction, and preventable radiation exposure
Objectives: Computed tomography (CT) has long been the gold standard in diagnosing patients with suspected small bowel obstruction (SBO). Recently, point‐of‐care ultrasound (POCUS) has demonstrated comparable test characteristics to CT imaging for the diagnosis of SBO. Our primary objective was to estimate the annual national cost saving impact of a POCUS‐first approach for the evaluation of SBO. Our secondary objectives were to estimate the reduction in radiation exposure and emergency department (ED) length of stay (LOS).Methods: We created and ran 1000 trials of a Monte Carlo simulation. The study population included all patients presenting to the ED with abdominal pain who were diagnosed with SBO. Using this simulation, we modeled the national annual cost savings in averted advanced imaging from a POCUS‐first approach for SBO. The model assumes that all patients who require surgery or have non‐diagnostic POCUS exams undergo CT imaging. The model also conservatively assumes that a subset of patients with diagnostic POCUS exams undergo additional confirmatory CT imaging. We used the same Monte Carlo model to estimate the reduction in radiation exposure and total ED bed hours saved.Results: A POCUS‐first approach for diagnosing SBO was estimated to save a mean (±SD) of $30.1 million (±8.9 million) by avoiding 143,000 (±31,000) CT scans. This resulted in a national cumulative decrease of 507,000 bed hours (±268,000) in ED LOS. The reduction in radiation exposure to patients could potentially prevent 195 (±56) excess annual cancer cases and 98 (±28) excess annual cancer deaths.Conclusions: If adopted widely and used consistently, a POCUS‐first algorithm for SBO could yield substantial national cost savings by averting advanced imaging, decreasing ED LOS, and reducing unnecessary radiation exposure in patients. Clinical decision tools are needed to better identify which patients would most benefit from CT imaging for SBO in the ED.
- Open Access
- 21 December 2021
- Published by Springer Nature in Cureus
- Vol. 13 (12) , e20587
Sonographic Assessment of the Effects of Mechanical Ventilation on Carotid Flow Time and Volume
Corrected carotid flow time (CFTc) and carotid blood flow (CBF) are sonographic measurements used to assess fluid responsiveness in hypotension. We investigated the impacts of mechanical ventilation on CFTc and CBF. Normotensive patients undergoing cardiac surgery were prospectively enrolled. Carotid ultrasound (US) was performed pre and post-intubation. Post-intubation measurements took place after the initiation of mechanical ventilation. To measure CFTc and CBF, a sagittal carotid view was obtained with pulse wave-Doppler (maximum angle 60°). CFTc was calculated with the Bazett formula (CFTc = systolic time/√cycle time). CBF was calculated using CBF (mL/min) = area (cm 2 ) x time average mean velocity (TAMEAN) (cm/sec) x 60 (sec/min). The maximum carotid diameter was measured at the level of the thyroid. Twenty patients were enrolled. Mean CFTc pre-intubation was 328 ms (SD 43.9 ms) compared to CFTc post-intubation 336 ms (SD 36 ms). There was no significant difference between pre and post-intubation CFTc (mean differences=-0.008; t(19)=-0.71, p=.49). Mean CBF pre-intubation was 487 mL/min (SD 176 mL/min) compared to CBF post-intubation 447 mL/min (SD 187 mL/min). There was no significant difference between pre and post-intubation CBF (mean differences= 40; t(19)=1.24, p=.23). In this study of normotensive patients, there were no detected differences in CFTc or CBF pre and post-intubation with mechanical ventilation.
- 21 December 2021
- Published by Springer Nature in Cureus
- Vol. 13 (12) , e20587
Open AccessSonographic Assessment of the Effects of Mechanical Ventilation on Carotid Flow Time and Volume
Corrected carotid flow time (CFTc) and carotid blood flow (CBF) are sonographic measurements used to assess fluid responsiveness in hypotension. We investigated the impacts of mechanical ventilation on CFTc and CBF. Normotensive patients undergoing cardiac surgery were prospectively enrolled. Carotid ultrasound (US) was performed pre and post-intubation. Post-intubation measurements took place after the initiation of mechanical ventilation. To measure CFTc and CBF, a sagittal carotid view was obtained with pulse wave-Doppler (maximum angle 60°). CFTc was calculated with the Bazett formula (CFTc = systolic time/√cycle time). CBF was calculated using CBF (mL/min) = area (cm 2 ) x time average mean velocity (TAMEAN) (cm/sec) x 60 (sec/min). The maximum carotid diameter was measured at the level of the thyroid. Twenty patients were enrolled. Mean CFTc pre-intubation was 328 ms (SD 43.9 ms) compared to CFTc post-intubation 336 ms (SD 36 ms). There was no significant difference between pre and post-intubation CFTc (mean differences=-0.008; t(19)=-0.71, p=.49). Mean CBF pre-intubation was 487 mL/min (SD 176 mL/min) compared to CBF post-intubation 447 mL/min (SD 187 mL/min). There was no significant difference between pre and post-intubation CBF (mean differences= 40; t(19)=1.24, p=.23). In this study of normotensive patients, there were no detected differences in CFTc or CBF pre and post-intubation with mechanical ventilation.
- 29 October 2021
- Published by Wiley in Pediatric Pulmonology
- Vol. 57 (1) , 333-336
Point‐of‐care respiratory muscle ultrasound in a child with medical complexity
- 29 October 2021
- Published by Wiley in Pediatric Pulmonology
- Vol. 57 (1) , 333-336
Point‐of‐care respiratory muscle ultrasound in a child with medical complexity
- 1 October 2021
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 48, 342-344
Do scan numbers predict point-of-care ultrasound use and accuracy in senior emergency medicine residents?
- 1 October 2021
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 48, 342-344
Do scan numbers predict point-of-care ultrasound use and accuracy in senior emergency medicine residents?
- Open Access
A Simplified Point-of-Care Lung Ultrasound Protocol to Detect Coronavirus Disease 2019 in Inpatients: A Prospective Observational Study
Objectives To assess the diagnostic performance of lung point-of-care ultrasound (POCUS) compared to either a positive nucleic acid test (NAT) or a COVID-19-typical pattern on computed tomography (CT) and to evaluate opportunities to simplify a POCUS algorithm. Methods Hospital-admitted adult inpatients with (1) either confirmed or suspected COVID-19 and (2) a completed or ordered CT within the preceding 24 hours were recruited. Twelve lung zones were scanned with a handheld POCUS machine. POCUS, CT, and X-ray (CXR) images were reviewed independently by blinded experts. A simplified POCUS algorithm was developed via machine learning. Results Of 79 enrolled subjects, 26.6% had a positive NAT and 31.6% had a CT typical for COVID-19. The receiver operator curve (ROC) for a 12-zone POCUS protocol had an area under the curve (AUC) of 0.787 for positive NAT and 0.820 for typical CT. A simplified four-zone protocol had an AUC of 0.862 for typical CT and 0.862 for positive NAT. CT had an AUC of 0.815 for positive NAT; CXR had AUCs of 0.793 for positive NAT and 0.733 for typical CT. Performance of the four-zone protocol was superior to CXR for positive NAT (p=0.0471). Using a two-point cutoff system, the four-zone POCUS protocol had a sensitivity of 0.920 and 0.904 compared to CT and NAT, respectively, at the lower cutoff; it had a specificity of 0.926 and 0.948 at the higher cutoff, respectively. Conclusion POCUS outperformed CXR to predict positive NAT. POCUS could potentially replace other chest imaging for persons under investigation for COVID-19.
Open AccessA Simplified Point-of-Care Lung Ultrasound Protocol to Detect Coronavirus Disease 2019 in Inpatients: A Prospective Observational Study
Objectives To assess the diagnostic performance of lung point-of-care ultrasound (POCUS) compared to either a positive nucleic acid test (NAT) or a COVID-19-typical pattern on computed tomography (CT) and to evaluate opportunities to simplify a POCUS algorithm. Methods Hospital-admitted adult inpatients with (1) either confirmed or suspected COVID-19 and (2) a completed or ordered CT within the preceding 24 hours were recruited. Twelve lung zones were scanned with a handheld POCUS machine. POCUS, CT, and X-ray (CXR) images were reviewed independently by blinded experts. A simplified POCUS algorithm was developed via machine learning. Results Of 79 enrolled subjects, 26.6% had a positive NAT and 31.6% had a CT typical for COVID-19. The receiver operator curve (ROC) for a 12-zone POCUS protocol had an area under the curve (AUC) of 0.787 for positive NAT and 0.820 for typical CT. A simplified four-zone protocol had an AUC of 0.862 for typical CT and 0.862 for positive NAT. CT had an AUC of 0.815 for positive NAT; CXR had AUCs of 0.793 for positive NAT and 0.733 for typical CT. Performance of the four-zone protocol was superior to CXR for positive NAT (p=0.0471). Using a two-point cutoff system, the four-zone POCUS protocol had a sensitivity of 0.920 and 0.904 compared to CT and NAT, respectively, at the lower cutoff; it had a specificity of 0.926 and 0.948 at the higher cutoff, respectively. Conclusion POCUS outperformed CXR to predict positive NAT. POCUS could potentially replace other chest imaging for persons under investigation for COVID-19.
- 8 January 2021
- Published by Wiley in AEM Education and Training
- Vol. 5 (3) , e10574
Longitudinal accuracy analysis of ultrasound performed during a four‐year emergency medicine residency
Background: The objective of this study was to analyze patterns of point‐of‐care ultrasound (POCUS) performance over 4 years of emergency medicine (EM) residency. Specifically, we aimed to study how accuracy and adherence to standards of scanning changed by postgraduate year (PGY).Methods: This was a retrospective observational study of resident‐performed POCUS at an academic emergency department over 6 years. We reviewed records of POCUS scans performed by PGY‐1 to ‐4 residents that had been collected for quality assurance purposes. Data that were collected about EM residents’ performance included the total number and type of scans per year, rate of technically limited scans (TLS), and accuracy on interpreting ultrasound images. Resident performances in each year (PGY‐1 to ‐4) were independently evaluated and reported.Results: During a 6‐year period, 137 different EM residents performed 50,815 ultrasound scans. The median number of scans was 177 for PGY‐1, 124 for PGY‐2, 118 for PGY‐3, and 76 for residents in PGY‐4. The accuracy of scan interpretations were high across all PGY levels (>97%), but slight degradation was observed as residents progressed through residency. The TLS rate increased from 4.7% among PGY‐1s to 13.6% as PGY‐4s.Conclusions: In this large cohort of POCUS studies by EM residents, POCUS accuracy rates decreased and rates of TLS significantly increased as residents progressed through residency.
- 8 January 2021
- Published by Wiley in AEM Education and Training
- Vol. 5 (3) , e10574
Longitudinal accuracy analysis of ultrasound performed during a four‐year emergency medicine residency
Background: The objective of this study was to analyze patterns of point‐of‐care ultrasound (POCUS) performance over 4 years of emergency medicine (EM) residency. Specifically, we aimed to study how accuracy and adherence to standards of scanning changed by postgraduate year (PGY).Methods: This was a retrospective observational study of resident‐performed POCUS at an academic emergency department over 6 years. We reviewed records of POCUS scans performed by PGY‐1 to ‐4 residents that had been collected for quality assurance purposes. Data that were collected about EM residents’ performance included the total number and type of scans per year, rate of technically limited scans (TLS), and accuracy on interpreting ultrasound images. Resident performances in each year (PGY‐1 to ‐4) were independently evaluated and reported.Results: During a 6‐year period, 137 different EM residents performed 50,815 ultrasound scans. The median number of scans was 177 for PGY‐1, 124 for PGY‐2, 118 for PGY‐3, and 76 for residents in PGY‐4. The accuracy of scan interpretations were high across all PGY levels (>97%), but slight degradation was observed as residents progressed through residency. The TLS rate increased from 4.7% among PGY‐1s to 13.6% as PGY‐4s.Conclusions: In this large cohort of POCUS studies by EM residents, POCUS accuracy rates decreased and rates of TLS significantly increased as residents progressed through residency.
- 3 September 2020
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 40 (4) , 845-852
Detecting Ventilator‐Induced Diaphragmatic Dysfunction Using Point‐of‐Care Ultrasound in Children With Long‐term Mechanical Ventilation
Long‐term mechanical ventilation (MV) is defined as the use of MV for more than 6 hours per day for at least 3 weeks. Children requiring long‐term MV include those with neuromuscular disease, central dysregulation, or lung dysfunction. Such children with medical complexity may be at risk for ventilator‐induced diaphragmatic dysfunction. Ventilator‐induced diaphragmatic dysfunction has been described in adult patients requiring acute MV with ultrasound (US). At this time, diaphragmatic US has not been evaluated in the pediatric post–acute care setting or incorporated into weaning strategies. We present 24 cases of children requiring long‐term MV who underwent diaphragmatic US examinations to evaluate for ventilator‐induced diaphragmatic dysfunction.
- 3 September 2020
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 40 (4) , 845-852
Detecting Ventilator‐Induced Diaphragmatic Dysfunction Using Point‐of‐Care Ultrasound in Children With Long‐term Mechanical Ventilation
Long‐term mechanical ventilation (MV) is defined as the use of MV for more than 6 hours per day for at least 3 weeks. Children requiring long‐term MV include those with neuromuscular disease, central dysregulation, or lung dysfunction. Such children with medical complexity may be at risk for ventilator‐induced diaphragmatic dysfunction. Ventilator‐induced diaphragmatic dysfunction has been described in adult patients requiring acute MV with ultrasound (US). At this time, diaphragmatic US has not been evaluated in the pediatric post–acute care setting or incorporated into weaning strategies. We present 24 cases of children requiring long‐term MV who underwent diaphragmatic US examinations to evaluate for ventilator‐induced diaphragmatic dysfunction.