MMMark A. Mighell

Mark A. Mighell

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mark A. Mighell has a total of 217 co-authors. Here are the top co-authors by number of shared publications:

  • Mark A. Frankle

    Department of Orthopaedics and Sports Medicine, University of South Florida Morsani College of Medicine, Tampa, Florida

    10 shared publications
  • Peter Simon

    Foundation for Orthopaedic Research and Education, Department of Translational Research, Tampa, FL; University of South Florida College of Engineering & Morsani College of Medicine, Department of Medical Engineering, Tampa, FL

    5 shared publications
  • Kaitlyn N. Christmas

    Translational Research, Foundation for Orthopaedic Research and Education, Tampa, FL, USA

    4 shared publications
  • Kaitlyn N. Christmas

    Foundation for Orthopaedic Research and Education, Tampa, FL, USA

    3 shared publications
  • Miguel A. Diaz

    Foundation for Orthopaedic Research and Education, Tampa, FL, USA

    3 shared publications
  • Peter Simon

    Foundation for Orthopaedic Research & Education, Tampa, FL, USA; Department of Orthopaedics and Sports Medicine, Morsani College of Medicine, Tampa, FL, USA

    3 shared publications

Latest Publications

  • Early adopter surgeon experience with Mako robotic-assisted reverse shoulder arthroplasty: perceived utility, workload, and workflow reliability

    by Mariano E. Menendez, Vahid Entezari, John G. Costouros, David Savin, Joseph A. Coory, Karimdad Amir Otarodi, Justin Givens, Erick M. Marigi, Travis M. Falconer, Jacob J. Triplet, et al.


  • Open Access

    Mako robotic-assisted glenoid preparation in reverse shoulder arthroplasty: a tail-risk reduction perspective compared with manual and patient-specific guide techniques

    by Neil P. Buac, Matthew Frederickson, Mark A. Mighell, Joaquin Sanchez-Sotelo, George S. Athwal, Mariano E. Menendez


  • The Subscapularis-Sparing Windowed Anterior Technique (SWAT) for Anatomic Total Shoulder Arthroplasty

    by Austin F. Smith, Michael N. Sirignano, Christian M. Schmidt, Mark A. Mighell

    Background: Anatomic total shoulder arthroplasty (aTSA) has historically been performed via the standard deltopectoral approach, requiring violation of the subscapularis to access the glenohumeral joint. Subscapularis dysfunction has been documented in as many as 67% of cases and may lead to instability, weakness, and lower patient-satisfaction scores 11–16 . However, the rate of subscapularis failure is much lower, at 1.6% to 3.0%, with a reoperation rate for a failed subscapularis of 0.9% to 3.0% 31,32 . To preserve the subscapularis tendon, muscle-preserving techniques have been developed that allow for early postoperative motion and activity without prolonged immobilization. The subscapularis-sparing windowed anterior technique (SWAT) is a method for aTSA that preserves the integrity of the subscapularis as well as the deltoid. As a result of the complete preservation of the subscapularis, this technique offers the advantage of early postoperative motion with no restrictions. This technique also avoids the deltoid split that is required in some other subscapularis-preserving techniques. Description: SWAT utilizes the standard deltopectoral incision. A window is created inferior to the subscapularis tendon and is utilized for the removal of inferior osteophytes, inferior translation of the humeral shaft, and capsular release. The rotator interval is also developed and is utilized to complete the humeral head cut, obtain glenoid exposure, and implant the components. Additionally, the use of preoperative planning allows accurate sizing of the humeral head component 30 . Prior studies have shown that this technique can be utilized to reliably attain acceptable radiographic and clinical outcomes 30 . Alternatives: Alternatives include aTSA performed via the standard deltopectoral approach with a lesser tuberosity osteotomy, aTSA with a subscapularis peel or tenotomy, hemiarthroplasty, and other subscapularis-sparing aTSA techniques. Rationale: The SWAT approach preserves the deltoid and the subscapularis by utilizing a deltopectoral approach and creating an inferior window to remove inferior osteophytes. This technique allows for adequate glenohumeral joint access, bone preparation, and implant selection and implantation. SWAT for aTSA is substantially different from other techniques described in the literature. Other subscapularis-sparing techniques require splitting of the deltoid 16–19,22 and substantial release of the inferior subscapularis 20,21 and have limitations related to difficult visualization of the humeral head for an accurate cut, difficult inferior osteophyte resection, and potential malalignment of the humeral components 17 . The SWAT has several benefits, including preservation of the deltoid, preservation of the subscapularis, the use of an inferior window to allow for complete removal of humeral osteophytes, adequate bone preparation, and accurate implant sizing and implantation. Expected Outcomes: Because of the complete preservation of the subscapularis, this technique offers the advantage of early postoperative motion with no restrictions. This technique also avoids the deltoid split that is required in some of the other subscapularis-sparing techniques. The SWAT aTSA is ideal for patients who would benefit from early mobilization and increased independence. The use of a sling can be discontinued early, and patients typically are satisfied with the level of function achieved in the first 2 weeks postoperatively. One prior study showed that this technique can be utilized to reliably attain acceptable radiographic and clinical outcomes 30 . No revisions or cases of mechanical failure were noted during the early postoperative period 30 . Therefore, the SWAT aTSA is a good option for patients without help at home and patients who will not tolerate, or whose quality of life will be substantially altered by, the use of a sling. Important Tips: Keep in mind that the SWAT can always be extended by takedown of the subscapularis at any point if there is concern regarding adequate access, especially if the surgeon is still learning the technique. The prevention of subscapularis rupture is based primarily on patient selection and intraoperative evaluation to confirm the integrity of the subscapularis. The subscapularis will not experience excessive stretching if the humerus is displaced inferiorly. Use of the inferior window to access and remove inferior osteophytes requires special care to protect the soft tissues by both directing the osteotome toward the glenoid during osteophyte removal as well as positioning the shoulder in adduction and external rotation. Place the elbow of the patient’s arm toward their navel. Removal of osteophytes and release of the humeral attachments of the capsule through the inferior window are crucial, even in cases with a small osteophyte; the releases and osteophyte removal that occur with use of the osteotome act to release the inferior joint capsule, which is important for mobilizing the humerus inferiorly when accessing the glenoid. An intramedullary guide is utilized to assist in obtaining a reproducible 135° humeral head cut at the anatomic neck plane to match the neck-shaft angle of the humeral implant. It is also important to utilize a saw blade with a limited excursion width. When performing the head cut through the rotator interval, having a blade with a limited excursion and having the arm in adduction will protect the soft tissues (i.e., the axillary nerve and subscapularis tendon) and will be less likely to damage the glenoid. The trial broach positioning will allow a suboptimal head cut to be identified and corrected. If unsatisfied with the size of the head cut following removal of the guide, the surgeon can utilize a calcar planer as necessary to remove additional bone. Several techniques can be utilized to match the humeral components with the patient’s premorbid anatomy and to avoid overstuffing. Preoperative templating with use of computed tomography scans and planning software helps to assess the appropriate head size. The use of a stemmed implant is preferred because it allows for the use of an intramedullary cutting guide, and having the stem helps to ensure appropriate implant positioning. Assessing the head cut and final stem position on fluoroscopy is also helpful. The final stem and head choices are impacted together on the back table and are implanted as an assembled humeral component. A tag suture is placed on the edge of the subscapularis and superior cuff in order to help facilitate implantation of the assembled humeral component. Acronyms and Abbreviations: SWAT = subscapularis-sparing windowed anterior technique aTSA = anatomic total shoulder arthroplasty LTO = lesser tuberosity osteotomy MRI = magnetic resonance imaging CT = computed tomography


  • Revision for instability following reverse total shoulder arthroplasty: outcomes and risk factors for failure

    by Craig Melbourne, Steven D. Munassi, Giovanni Ayala, Kaitlyn N. Christmas, Miguel Diaz, Peter Simon, Mark A. Mighell, Mark A. Frankle


  • Does improved external rotation following reverse shoulder arthroplasty impact clinical outcomes in patients with rotator cuff pathology and external rotation less than 0°?

    by Georges Haidamous, Brandon Cabarcas, Levonti Ohanisian, Peter Simon, Kaitlyn N. Christmas, Lauren Wilder, Kyle Achors, Mark A. Mighell, Mark A. Frankle


  • Improved mechanical fixation of an all-polyethylene glenoid reduces postoperative radiolucent lines

    by Roshan Melvani, Miguel A. Diaz, Lauren Wilder, Kaitlyn N. Christmas, Peter Simon, Kevin J. Cronin, Mark A. Mighell, Mark A. Frankle


  • Open Access

    A Weaving Rip‐Stop Technique Leads to a Significantly Increased Load to Failure and Reduction in Suture‐Tendon Cut‐Through in a Biomechanical Model of Rotator Cuff Repair

    by Ryan A. Neeley, Miguel A. Diaz, R. Allen Gorman, Mark A. Frankle, Mark A. Mighell

    Purpose: To present an alternative arthroscopic rip‐stop technique with a single suture tape weaved through the tendon from anterior to posterior and to biomechanically test its strength against a control technique consisting of a single‐row repair with simple sutures. Methods: This was a controlled biomechanical study. Dissection and harvesting of the supraspinatus muscle‐tendon unit were performed along the cable in 9 matched‐pair cadaveric shoulders. Samples were divided into 2 groups: simple suture repair only (SSR) and simple suture repair with rip‐stop (SSPR). Biomechanical testing was performed with an initial preload, followed by cyclic loading and then ramp to failure. Peak‐to‐peak displacement, stiffness (in newtons per millimeter), load at failure (in newtons), and failure mechanism were recorded. Data were compared using the paired‐sample t test. Results: The average peak‐to‐peak displacement for SSR samples was not significantly different from that of SSPR samples ( P = .96). Similarly, elongation in the SSR and SSPR groups was not significantly different ( P = .82). Stiffness was significantly different between the SSR and SSPR groups ( P = .0054): SSR samples were less stiff than SSPR samples. Moreover, SSR samples failed at significantly lower forces than did SSPR samples ( P = .028). A larger percentage of failures occurred due to tendon cut‐through among SSR samples versus suture breakage among SSPR samples. Conclusions: An alternative rip‐stop technique is presented in this biomechanical model that may assist surgeons to better deal with difficult rotator cuff repairs. Weaving a suture tape as a rip‐stop can increase stiffness, achieve higher failure loads when compared with simple suture repair with no rip‐stop, and reduce tendon cut‐through. Clinical Relevance: This study provides insight into a variation of rip‐stop stitch techniques that may help solve the clinical problem of failure occurring at the suture‐tendon interface, specifically tendon cut‐through.


  • Open Access

    Machine Learning Can Predict Level of Improvement in Shoulder Arthroplasty

    by Paul B. McLendon, Kaitlyn N. Christmas, Peter Simon, Otho R. Plummer, Audrey Hunt, Adil S. Ahmed, Mark A. Mighell, Mark A. Frankle

    Background: The ability to accurately predict postoperative outcomes is of considerable interest in the field of orthopaedic surgery. Machine learning has been used as a form of predictive modeling in multiple health-care settings. The purpose of the current study was to determine whether machine learning algorithms using preoperative data can predict improvement in American Shoulder and Elbow Surgeons (ASES) scores for patients with glenohumeral osteoarthritis (OA) at a minimum of 2 years after shoulder arthroplasty. Methods: This was a retrospective cohort study that included 472 patients (472 shoulders) diagnosed with primary glenohumeral OA (mean age, 68 years; 56% male) treated with shoulder arthroplasty (431 anatomic total shoulder arthroplasty and 41 reverse total shoulder arthroplasty). Preoperative computed tomography (CT) scans were used to classify patients on the basis of glenoid and rotator cuff morphology. Preoperative and final postoperative ASES scores were used to assess the level of improvement. Patients were separated into 3 improvement ranges of approximately equal size. Machine learning methods that related patterns of these variables to outcome ranges were employed. Three modeling approaches were compared: a model with the use of all baseline variables (Model 1), a model omitting morphological variables (Model 2), and a model omitting ASES variables (Model 3). Results: Improvement ranges of ≤28 points (class A), 29 to 55 points (class B), and >55 points (class C) were established. Using all follow-up time intervals, Model 1 gave the most accurate predictions, with probability values of 0.94, 0.95, and 0.94 for classes A, B, and C, respectively. This was followed by Model 2 (0.93, 0.80, and 0.73) and Model 3 (0.77, 0.72, and 0.71). Conclusions: Machine learning can accurately predict the level of improvement after shoulder arthroplasty for glenohumeral OA. This may allow physicians to improve patient satisfaction by better managing expectations. These predictions were most accurate when latent variables were combined with morphological variables, suggesting that both patients’ perceptions and structural pathology are critical to optimizing outcomes in shoulder arthroplasty. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


  • Use of a modified Outerbridge-Kashiwagi procedure for the treatment of posttraumatic elbow sequelae

    by Earl E. Brewley, R. Allen Gorman, Kaitlyn N. Christmas, Peter Simon, Ross J. Chapel, Mark A. Mighell


  • Do preoperative radiographs help predict intraoperative challenges in revision surgery after previous shoulder hemiarthroplasty?

    by David E. O’bRiain, Peter Simon, Kaitlyn N. Christmas, Miguel A. Diaz, A. Vincent Hess, Eric G. Hernandez-Ortiz, Thomas Sellers, Paul B. McLendon, Mark A. Mighell, Mark A. Frankle