Nejdet Değermenci
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nejdet Değermenci has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Ergun Yildiz
Department of Environmental Engineering, Faculty of Engineering, Atatürk University, Erzurum, Turkey
5 shared publications Ibrahim Cengiz
Department of Emergency Aid and Disaster Management, Atatürk University, Erzurum, Türkiye
3 shared publicationsAlper Nuhoglu
Department of Environmental Engineering, Engineering Faculty, Atatürk University, Erzurum 25240, Turkey
2 shared publicationsErgun Yildiz
Department of Environmental Engineering, Atatürk University, Erzurum, Türkiye
2 shared publicationsGökçe Didar Değermenci
Faculty of Engineering and Architecture, Department of Environmental Engineering, Kastamonu University, Kastamonu, Türkiye
2 shared publications- Gökçe Didar Değermenci
Department of Environmental Engineering, Kastamonu University, Kastamonu, Türkiye
2 shared publications
Latest Publications
- 9 September 2026
- Published by Springer Nature in Chemical Papers
- p. 1-13
Energy-efficient ozonation of textile wastewater in a tubular jet reactor: mass transfer, kinetics, and process performance
- 9 September 2026
- Published by Springer Nature in Chemical Papers
- p. 1-13
Energy-efficient ozonation of textile wastewater in a tubular jet reactor: mass transfer, kinetics, and process performance
- Open Access
- 9 August 2026
- Published by Echo Academic Publishing in Environmental Research and Technology
- Vol. 9 (4) , 662-670
Degradation of chloridazon in aqueous solutions by UV/H2O2 process: Performance, kinetics, and degradation pathways
This study investigated the removal of chloridazon (CLZ) by the UV/H2O2 process. The effect of initial CLZ concentration, H2O2 concentration, initial pH, and the temperature was sought. The rate at which CLZ disappeared from the medium decreases as the initial CLZ concentration increases under the optimum operating conditions of 20 mg/L H2O2, initial pH 3, and 20°C, as such that 10 mg/L solution was completely treated in 15 minutes, whereas a 40 mg/L solution only reached 82% removal after 60 minutes. The reaction kinetics of CLZ degradation followed pseudo-first-order kinetics. The respective rate constants were 0.3049 min-1 and 0.0311 min-1. The multiple linear regression model achieved an R-squared value of 0.812, indicating that the independent variables accounted for 81.2% of the variance in CLZ removal. Desphenyl chloridazon and 5-hydroxyhydantion were the CLZ degradation by-products identified.
- 9 August 2026
- Published by Echo Academic Publishing in Environmental Research and Technology
- Vol. 9 (4) , 662-670
Open AccessDegradation of chloridazon in aqueous solutions by UV/H2O2 process: Performance, kinetics, and degradation pathways
This study investigated the removal of chloridazon (CLZ) by the UV/H2O2 process. The effect of initial CLZ concentration, H2O2 concentration, initial pH, and the temperature was sought. The rate at which CLZ disappeared from the medium decreases as the initial CLZ concentration increases under the optimum operating conditions of 20 mg/L H2O2, initial pH 3, and 20°C, as such that 10 mg/L solution was completely treated in 15 minutes, whereas a 40 mg/L solution only reached 82% removal after 60 minutes. The reaction kinetics of CLZ degradation followed pseudo-first-order kinetics. The respective rate constants were 0.3049 min-1 and 0.0311 min-1. The multiple linear regression model achieved an R-squared value of 0.812, indicating that the independent variables accounted for 81.2% of the variance in CLZ removal. Desphenyl chloridazon and 5-hydroxyhydantion were the CLZ degradation by-products identified.
- 25 October 2025
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 237 (1) , 1-14
Removal of 2-Chlorophenol by Ozonation Under Strongly Alkaline Conditions in a Jet Loop Reactor
- 25 October 2025
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 237 (1) , 1-14
Removal of 2-Chlorophenol by Ozonation Under Strongly Alkaline Conditions in a Jet Loop Reactor
- Open Access
- 2 July 2025
- Published by Wiley in Global Challenges
- Vol. 9 (8)
Removal of Phenol by Ozonation in Strongly Alkaline Conditions using a Jet Loop Reactor Operated in Continuous Phase
In this study, phenol removal by ozonation under strong alkaline conditions in a continuously operated jet loop reactor (JLR) is investigated. The effects of inlet ozone gas concentration, hydraulic retention time (HRT), and influent phenol concentration on phenol, chemical oxygen demand (COD), and total organic carbon (TOC) removal in the JLR effluent are evaluated. When the inlet ozone gas concentration is 17.5 gO3 m−3, the steady‐state phenol, COD, and TOC removal efficiencies are determined as 97.8%, 61.1%, and 32.2%, respectively. When the inlet ozone concentration increases from 17.5 to 56.5 gO3 m−3, phenol is not detected in the JLR effluent. The system operates at different HRTs, and the highest removal efficiency at steady‐state is obtained at 8 h HRT. While phenol is completely removed at this HRT, COD and TOC removals are 76.8% and 48.2%, respectively. An increase in phenol concentration in the JLR influent leads to a reduction in the phenol, COD, and TOC removal efficiencies in the steady‐state effluent.
- 2 July 2025
- Published by Wiley in Global Challenges
- Vol. 9 (8)
Open AccessRemoval of Phenol by Ozonation in Strongly Alkaline Conditions using a Jet Loop Reactor Operated in Continuous Phase
In this study, phenol removal by ozonation under strong alkaline conditions in a continuously operated jet loop reactor (JLR) is investigated. The effects of inlet ozone gas concentration, hydraulic retention time (HRT), and influent phenol concentration on phenol, chemical oxygen demand (COD), and total organic carbon (TOC) removal in the JLR effluent are evaluated. When the inlet ozone gas concentration is 17.5 gO3 m−3, the steady‐state phenol, COD, and TOC removal efficiencies are determined as 97.8%, 61.1%, and 32.2%, respectively. When the inlet ozone concentration increases from 17.5 to 56.5 gO3 m−3, phenol is not detected in the JLR effluent. The system operates at different HRTs, and the highest removal efficiency at steady‐state is obtained at 8 h HRT. While phenol is completely removed at this HRT, COD and TOC removals are 76.8% and 48.2%, respectively. An increase in phenol concentration in the JLR influent leads to a reduction in the phenol, COD, and TOC removal efficiencies in the steady‐state effluent.
- Open Access
- 15 May 2024
- Published by Black Sea Journal of Engineering and Science in Black Sea Journal of Engineering and Science
- Vol. 7 (3) , 539-546
Electrochemical Hydrogen Peroxide Generation and Removal of Moxifloxacin by Electro-Fenton Process
In this study, the removal of moxifloxacin, an antibiotic of the fluoroquinolone group, from aqueous solutions was investigated using the electro-Fenton process. As the efficiency of the electro-Fenton process is highly dependent on the amount of H2O2 produced during process, the formation of H2O2 under acidic conditions was also investigated. In this context, the effects of applied current, cathode type and O2 flow rate on H2O2 production were investigated using boron-doped diamond anode. The highest H2O2 production was achieved using the boron-doped diamond anode and the graphite felt cathode. In addition, the optimum conditions for the applied current and oxygen flow rate for H2O2 production were determined to be 0.25 A and 0.1 L min−1, respectively. The effects of applied current and Fe2+ concentration in the electro-Fenton process on the removal of moxifloxacin were investigated. It was found that the moxifloxacin removal rate increased with increasing applied current. The highest H2O2 accumulation was observed at 0.25 A applied current, and moxifloxacin removal also reached 93.6% after 60 min. The moxifloxacin removal rate reached the highest value at Fe2+ concentration of 0.01 mM. This study provides promising results for the efficient treatment of moxifloxacin-containing wastewater by the electro-Fenton process without the addition of H2O2 using boron-doped diamond anode anode and graphite felt cathode.
- 15 May 2024
- Published by Black Sea Journal of Engineering and Science in Black Sea Journal of Engineering and Science
- Vol. 7 (3) , 539-546
Open AccessElectrochemical Hydrogen Peroxide Generation and Removal of Moxifloxacin by Electro-Fenton Process
In this study, the removal of moxifloxacin, an antibiotic of the fluoroquinolone group, from aqueous solutions was investigated using the electro-Fenton process. As the efficiency of the electro-Fenton process is highly dependent on the amount of H2O2 produced during process, the formation of H2O2 under acidic conditions was also investigated. In this context, the effects of applied current, cathode type and O2 flow rate on H2O2 production were investigated using boron-doped diamond anode. The highest H2O2 production was achieved using the boron-doped diamond anode and the graphite felt cathode. In addition, the optimum conditions for the applied current and oxygen flow rate for H2O2 production were determined to be 0.25 A and 0.1 L min−1, respectively. The effects of applied current and Fe2+ concentration in the electro-Fenton process on the removal of moxifloxacin were investigated. It was found that the moxifloxacin removal rate increased with increasing applied current. The highest H2O2 accumulation was observed at 0.25 A applied current, and moxifloxacin removal also reached 93.6% after 60 min. The moxifloxacin removal rate reached the highest value at Fe2+ concentration of 0.01 mM. This study provides promising results for the efficient treatment of moxifloxacin-containing wastewater by the electro-Fenton process without the addition of H2O2 using boron-doped diamond anode anode and graphite felt cathode.
- 15 September 2023
- Published by Springer Nature in Fibers and Polymers
- Vol. 24 (11) , 3753-3760
Removal of Phosphate from Aqueous Solution Using Anion Exchange Resin: Equilibrium Isotherms and Kinetics
- 15 September 2023
- Published by Springer Nature in Fibers and Polymers
- Vol. 24 (11) , 3753-3760
Removal of Phosphate from Aqueous Solution Using Anion Exchange Resin: Equilibrium Isotherms and Kinetics
- 28 March 2022
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 194 (4) , 1-14
Comparison of reactive azo dye removal with UV/H2O2, UV/S2O82− and UV/HSO5− processes in aqueous solutions
Advanced oxidation processes (AOPs) are an effective choice for removal of reactive azo dyes used in the textile industry due to high solubility and low degradability. Within the scope of this study, reactive orange 122 (RO122) azo dye was removed using the UV-based AOPs of ultraviolet (UV) radiation, UV/hydrogen peroxide (UV/H2O2), UV/persulfate (UV/S2O82−), and UV/peroxymonosulfate (UV/HSO5−). Oxidant concentration, initial solution pH, initial RO122 concentration, different anions (Cl−, NO3− and SO42−), and solution temperature effects were compared. With only UV radiation (254 nm), 19.5% RO122 removal occurred at the end of 120 min. The RO122 removal reduced with the UV/oxidant processes at pH 9. Experimental results revealed RO122 removal followed pseudo-first-order (PFO) kinetics. There was a linear correlation identified between initial oxidant concentration and the PFO kinetic rate constant (k1). Among the three UV-based processes, with oxidant concentration 50 mg/L, temperature 20 °C, and pH 5, RO122 removal efficiency was in the order UV/H2O2 > UV/HSO5− > UV/S2O82−. RO122 removal rate increased as initial oxidant concentration and temperature increased and reduced as initial RO122 concentration increased. Energy requirements and oxidant costs were assessed. The UV/H2O2 process was concluded to be the most efficient and economic process for RO122 removal.
- 28 March 2022
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 194 (4) , 1-14
Comparison of reactive azo dye removal with UV/H2O2, UV/S2O82− and UV/HSO5− processes in aqueous solutions
Advanced oxidation processes (AOPs) are an effective choice for removal of reactive azo dyes used in the textile industry due to high solubility and low degradability. Within the scope of this study, reactive orange 122 (RO122) azo dye was removed using the UV-based AOPs of ultraviolet (UV) radiation, UV/hydrogen peroxide (UV/H2O2), UV/persulfate (UV/S2O82−), and UV/peroxymonosulfate (UV/HSO5−). Oxidant concentration, initial solution pH, initial RO122 concentration, different anions (Cl−, NO3− and SO42−), and solution temperature effects were compared. With only UV radiation (254 nm), 19.5% RO122 removal occurred at the end of 120 min. The RO122 removal reduced with the UV/oxidant processes at pH 9. Experimental results revealed RO122 removal followed pseudo-first-order (PFO) kinetics. There was a linear correlation identified between initial oxidant concentration and the PFO kinetic rate constant (k1). Among the three UV-based processes, with oxidant concentration 50 mg/L, temperature 20 °C, and pH 5, RO122 removal efficiency was in the order UV/H2O2 > UV/HSO5− > UV/S2O82−. RO122 removal rate increased as initial oxidant concentration and temperature increased and reduced as initial RO122 concentration increased. Energy requirements and oxidant costs were assessed. The UV/H2O2 process was concluded to be the most efficient and economic process for RO122 removal.
- Open Access
- 27 February 2021
- Published by ASOS Yayinevi in European Journal of Science and Technology
- No. 23,p. 272-279
Katyon Değişim Reçinesi Kullanarak Sulu Çözeltilerden Amonyum Giderimi
Amonyum, su kütlelerinin ötrofikasyonundan sorumlu temel faktörlerden biridir. Amonyum giderim etkinliği üzerindeki potansiyel kullanımını araştırmak amacıyla Purolite SSTC60 iyon değiştirici reçine kullanılmıştır. İyon değiştirici reçine dozajı, başlangıç çözelti pH’ı, sıcaklık, karıştırma hızı ve başlangıç amonyum konsantrasyonu gibi iyon değişimini etkileyen önemli parametrelerin amonyum giderimi üzerine etkisi araştırıldı. Çeşitli pH değerlerinde yapılan kesikli deneyler sonucunda pH 7 değerinde en yüksek amonyum giderimi sağlanmıştır. Reçine dozajı, karıştırma hızı ve sıcaklık artışı ile amonyum giderim hızlarının arttığı belirlenmiştir. Giderim verimleri açısında başlangıç amonyum konsantrasyonunun artışı ile giderim verimleri azalmaktadır. 20°C’den daha yüksek sıcaklıkların ve karıştırma hızının denge anında ki amonyum giderim verimleri üzerine çok fazla bir etkisi olmadığı belirlenmiştir. Daha sonra amonyum iyonlarının Purolite SSTC60 iyon değişim reçinesi ile gideriminde en uygun kinetik denklemi belirlemek üzere yalancı birinci derece ve yalancı ikinci derece kinetik denklemler lineer olmayan yöntem kullanılarak analiz edildi. Sonuçlar amonyumun iyon değiştirme prosesi ile gideriminde, yalancı birinci dereceden kinetik model ile daha iyi aydınlatılabileceğini ortaya koymuştur.
- 27 February 2021
- Published by ASOS Yayinevi in European Journal of Science and Technology
- No. 23,p. 272-279
Open AccessKatyon Değişim Reçinesi Kullanarak Sulu Çözeltilerden Amonyum Giderimi
Amonyum, su kütlelerinin ötrofikasyonundan sorumlu temel faktörlerden biridir. Amonyum giderim etkinliği üzerindeki potansiyel kullanımını araştırmak amacıyla Purolite SSTC60 iyon değiştirici reçine kullanılmıştır. İyon değiştirici reçine dozajı, başlangıç çözelti pH’ı, sıcaklık, karıştırma hızı ve başlangıç amonyum konsantrasyonu gibi iyon değişimini etkileyen önemli parametrelerin amonyum giderimi üzerine etkisi araştırıldı. Çeşitli pH değerlerinde yapılan kesikli deneyler sonucunda pH 7 değerinde en yüksek amonyum giderimi sağlanmıştır. Reçine dozajı, karıştırma hızı ve sıcaklık artışı ile amonyum giderim hızlarının arttığı belirlenmiştir. Giderim verimleri açısında başlangıç amonyum konsantrasyonunun artışı ile giderim verimleri azalmaktadır. 20°C’den daha yüksek sıcaklıkların ve karıştırma hızının denge anında ki amonyum giderim verimleri üzerine çok fazla bir etkisi olmadığı belirlenmiştir. Daha sonra amonyum iyonlarının Purolite SSTC60 iyon değişim reçinesi ile gideriminde en uygun kinetik denklemi belirlemek üzere yalancı birinci derece ve yalancı ikinci derece kinetik denklemler lineer olmayan yöntem kullanılarak analiz edildi. Sonuçlar amonyumun iyon değiştirme prosesi ile gideriminde, yalancı birinci dereceden kinetik model ile daha iyi aydınlatılabileceğini ortaya koymuştur.
- 19 February 2021
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 28 (24) , 31462-31469
Ammonia stripping using a continuous flow jet loop reactor: mass transfer of ammonia and effect on stripping performance of influent ammonia concentration, hydraulic retention time, temperature, and air flow rate
When wastewater containing ammonia is discharged into the receiving environment without any kind of treatment, it causes both environmental problems and negatively affects human health. In this study, the aim was to strip ammonia using air in a continuous flow jet loop reactor (JLR) and investigate the effects of ammonia concentration, hydraulic retention time (HRT), air flow rate, and temperature on ammonia removal within this scope. By changing the ammonia concentration in the influent, no significant change was observed in ammonia removal efficiency. With air flow rate 45 L min−1, temperature 50 °C, pH 11, and HRT 7.5 h, mean 88.1% ammonia removal was achieved. Increasing the HRT, air flow rate, and temperature increased the ammonia removal efficiency. Later the ammonia stripping process in the continuous flow JLR was modeled and the volumetric mass transfer coefficient (KLa) for each parameter was calculated from the model equation. While the experimental parameters of air flow rate and temperature had a significant effect on the mass transfer coefficient, influent ammonia concentration and HRT were determined to have no effect.
- 19 February 2021
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 28 (24) , 31462-31469
Ammonia stripping using a continuous flow jet loop reactor: mass transfer of ammonia and effect on stripping performance of influent ammonia concentration, hydraulic retention time, temperature, and air flow rate
When wastewater containing ammonia is discharged into the receiving environment without any kind of treatment, it causes both environmental problems and negatively affects human health. In this study, the aim was to strip ammonia using air in a continuous flow jet loop reactor (JLR) and investigate the effects of ammonia concentration, hydraulic retention time (HRT), air flow rate, and temperature on ammonia removal within this scope. By changing the ammonia concentration in the influent, no significant change was observed in ammonia removal efficiency. With air flow rate 45 L min−1, temperature 50 °C, pH 11, and HRT 7.5 h, mean 88.1% ammonia removal was achieved. Increasing the HRT, air flow rate, and temperature increased the ammonia removal efficiency. Later the ammonia stripping process in the continuous flow JLR was modeled and the volumetric mass transfer coefficient (KLa) for each parameter was calculated from the model equation. While the experimental parameters of air flow rate and temperature had a significant effect on the mass transfer coefficient, influent ammonia concentration and HRT were determined to have no effect.
- 3 February 2020
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 231 (2) , 1-13
Decolorization of the Reactive Blue 19 from Aqueous Solutions with the Fenton Oxidation Process and Modeling with Deep Neural Networks
- 3 February 2020
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 231 (2) , 1-13
Decolorization of the Reactive Blue 19 from Aqueous Solutions with the Fenton Oxidation Process and Modeling with Deep Neural Networks