Wentao Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wentao Zhang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Bing Gao
School of Bioscience and Bioengineering, South China University of Technology, Higher Education Mega Center, Guangzhou 510006, China
1 shared publication Cheng-Jun Sun
1 shared publication- Guangyu Li
First Affiliated Hospital of China Medical University
1 shared publication - Lei Dong
Department of Neurosurgery, First Affiliated Hospital of China Medical University, Shenyang 110001, China
1 shared publication Si-Te Li
1 shared publication- Wen Tan
Institute of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China
1 shared publication
Latest Publications
- Open Access
- 28 March 2016
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 17 (4) , 458
Apolipoprotein A1-Unique Peptide as a Diagnostic Biomarker for Acute Ischemic Stroke
Clinically-informative biomarkers of ischemic stroke are needed for rapid diagnosis and timely treatment. In the present study, APOA1 unique peptide (APOA1-UP), a novel peptide biomarker, was identified and quantified by multiple reaction monitoring (MRM) using labeled reference peptide (LRP). Serum samples of 94 patients in the ischemic stroke group and 37 patients in the non-stroke group were analyzed for the levels of total APOA1-UP, low density lipoprotein cholesterol (LDL-C), triglycerides (TG), high-density lipoprotein cholesterol (HDL-C), and total cholesterol (TC). Median ratio of total APOA1-UP/LRP was 2.14 (interquartile range, 0.40) in the non-stroke group and 1.32 (0.44) in the ischemic stroke group (p < 0.0001). The serum level of total APOA1-UP was independently correlated with the presence of ischemic stroke by multivariate logistic regression analysis (p < 0.0001). From the receiver operating characteristic (ROC) curve, the area under the curve (AUC) was 0.9750 and the optimal cutoff value of the serum APOA1-UP level was 1.80, which yielded a sensitivity of 90.63% and a specificity of 97.14%. The diagnostic efficiency of HDL-C was lower, with an AUC of 0.7488. Therefore, the serum level of APOA1-UP is a diagnostic biomarker candidate for ischemic stroke in the early stage.
- 28 March 2016
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 17 (4) , 458
Open AccessApolipoprotein A1-Unique Peptide as a Diagnostic Biomarker for Acute Ischemic Stroke
Clinically-informative biomarkers of ischemic stroke are needed for rapid diagnosis and timely treatment. In the present study, APOA1 unique peptide (APOA1-UP), a novel peptide biomarker, was identified and quantified by multiple reaction monitoring (MRM) using labeled reference peptide (LRP). Serum samples of 94 patients in the ischemic stroke group and 37 patients in the non-stroke group were analyzed for the levels of total APOA1-UP, low density lipoprotein cholesterol (LDL-C), triglycerides (TG), high-density lipoprotein cholesterol (HDL-C), and total cholesterol (TC). Median ratio of total APOA1-UP/LRP was 2.14 (interquartile range, 0.40) in the non-stroke group and 1.32 (0.44) in the ischemic stroke group (p < 0.0001). The serum level of total APOA1-UP was independently correlated with the presence of ischemic stroke by multivariate logistic regression analysis (p < 0.0001). From the receiver operating characteristic (ROC) curve, the area under the curve (AUC) was 0.9750 and the optimal cutoff value of the serum APOA1-UP level was 1.80, which yielded a sensitivity of 90.63% and a specificity of 97.14%. The diagnostic efficiency of HDL-C was lower, with an AUC of 0.7488. Therefore, the serum level of APOA1-UP is a diagnostic biomarker candidate for ischemic stroke in the early stage.
- Open Access
- 27 June 2013
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 14 (7) , 13377-13390
A Labile Pool of IQGAP1 Disassembles Endothelial Adherens Junctions
Adhesion molecules are known to play an important role in endothelial activation and angiogenesis. Here we determined the functional role of IQGAP1 in the regulation of endothelial adherens junctions. VE-cadherin is found to be associated with actin filaments and thus stable, but IQGAP1 at intercellular junctions is not bound to actin filaments and thus labile. Expression of GFP labeled VE-α-catenin is shown to increase the electrical resistance across HUVEC monolayers and diminishes endogenous labile IQGAP1 at the intercellular junctions. Knockdown of endogenous IQGAP1 enhances intercellular adhesion in HUVECs by increasing the association of VE-cadherin with P120 and β-catenin. IQGAP1 knockdown also decreases the interaction of N-cadherin with P120 and β-catenin. Together, these results suggest that a labile pool of IQGAP1 at intercellular junctions disassembles adherens junctions and thus impairs endothelial cell-cell adhesion.
- 27 June 2013
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 14 (7) , 13377-13390
Open AccessA Labile Pool of IQGAP1 Disassembles Endothelial Adherens Junctions
Adhesion molecules are known to play an important role in endothelial activation and angiogenesis. Here we determined the functional role of IQGAP1 in the regulation of endothelial adherens junctions. VE-cadherin is found to be associated with actin filaments and thus stable, but IQGAP1 at intercellular junctions is not bound to actin filaments and thus labile. Expression of GFP labeled VE-α-catenin is shown to increase the electrical resistance across HUVEC monolayers and diminishes endogenous labile IQGAP1 at the intercellular junctions. Knockdown of endogenous IQGAP1 enhances intercellular adhesion in HUVECs by increasing the association of VE-cadherin with P120 and β-catenin. IQGAP1 knockdown also decreases the interaction of N-cadherin with P120 and β-catenin. Together, these results suggest that a labile pool of IQGAP1 at intercellular junctions disassembles adherens junctions and thus impairs endothelial cell-cell adhesion.
- 1 September 2010
- Vol. 41 (5) , 873-6, 895
[Simultaneous determination of five illegal drugs in weight control foods with solid phase extraction-high performance liquid chromatography].
To develop a method for simultaneous determination of hydrochlorothiazide, furosemide, clopamide, bumetanide and sibutramine hydrochloride in weight control foods with solid phase extraction-high performance liquid chromatography. The analytes in the samples were extracted with 2% phosphoric acid-methanol (1:1, V/V) solution ultrasonically and centrifuged. The extracts were clean-up with Osis MCX SPE columns, concentrated under weak N2 stream, and reconstituted with 2% phosphoric acid-methanol (1:1, V/V) solution, vortex mixing and centrifugation at 12,000 r/min. The high performance liquid chromatography was performed with Phenomenex C18 (250 x 4.60 mm, 5 microm) as separation column, 0.02 mol/L acetonitrile potassium dihydrogen phosphate buffer as mobile phase, gradient elution of 1.0 mL/min for the flow rate, and 40 degrees C for the column temperature. The standard curve method was used for the quantitative analysis. A good linear range appeared for the five analytes from 0.25 to 100 microg/mL (r > or = 0.999). The detection limits were 5.2-108 microg/kg. The average recoveries were 86.5%-113.1%, with the relative standard deviations of 1.6%-8.9%. The proposed method is a reliable method with high selectivity and high sensitivity for the detection of the five illegal chemicals in the weight control foods.
- 1 September 2010
- Vol. 41 (5) , 873-6, 895
[Simultaneous determination of five illegal drugs in weight control foods with solid phase extraction-high performance liquid chromatography].
To develop a method for simultaneous determination of hydrochlorothiazide, furosemide, clopamide, bumetanide and sibutramine hydrochloride in weight control foods with solid phase extraction-high performance liquid chromatography. The analytes in the samples were extracted with 2% phosphoric acid-methanol (1:1, V/V) solution ultrasonically and centrifuged. The extracts were clean-up with Osis MCX SPE columns, concentrated under weak N2 stream, and reconstituted with 2% phosphoric acid-methanol (1:1, V/V) solution, vortex mixing and centrifugation at 12,000 r/min. The high performance liquid chromatography was performed with Phenomenex C18 (250 x 4.60 mm, 5 microm) as separation column, 0.02 mol/L acetonitrile potassium dihydrogen phosphate buffer as mobile phase, gradient elution of 1.0 mL/min for the flow rate, and 40 degrees C for the column temperature. The standard curve method was used for the quantitative analysis. A good linear range appeared for the five analytes from 0.25 to 100 microg/mL (r > or = 0.999). The detection limits were 5.2-108 microg/kg. The average recoveries were 86.5%-113.1%, with the relative standard deviations of 1.6%-8.9%. The proposed method is a reliable method with high selectivity and high sensitivity for the detection of the five illegal chemicals in the weight control foods.