Pavan S. Kulkarni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Pavan S. Kulkarni has a total of 98 co-authors. Here are the top co-authors by number of shared publications:
- Daniele Bortoli
Center for Sci-Tech Research in Earth System and Energy (CREATE), Department of Physics, School of Sciences and Technology, University of Évora, 7000-671 Évora, Portugal
14 shared publications - Ana Maria Silva
Department of Physics, Institute of Earth Sciences, Institute for Advanced Studies and Research, University of Évora, 7000-671 Évora, Portugal
12 shared publications B. C. Arya
Radio and Atmospheric Sciences Division , National Physical Laboratory , New Delhi, India
10 shared publications- Sachin D. Ghude
Indian Institute of Tropical Meteorology Pune India
8 shared publications - Maria João Costa
Universidade de Évora, Centro de Investigação em Ciência e Tecnologia para o Sistema Terra e Energia (CREATE) e Departamento de Física, Escola de Ciências e Tecnologia, 7000-671 Évora, Portugal
7 shared publications - Premshankar Kumar Dubey
Pressure, Vacuum and Ultrasonic Metrology, Division of Physico-Mechanical Metrology, CSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi 110012, India
6 shared publications
Latest Publications
- Open Access
- 31 August 2022
- Published by Universidad Tecnica de Manabi in International journal of health sciences
- p. 8676-8685
Evaluation of shear bond strength of porcelain to metal and zirconia cores
Aim: The aim of the study is to find out the difference between the shear bond strength values and failure pattern between the metal ceramic system and zirconia core veneering system. Materials and methods: A study was conducted to find out the difference between the shear bond strength values and failure pattern between the metal ceramic system and zirconia core veneering system. A total of 30 samples were divided into three groups. The first group contains metal core(Ni-Cr base metal-10nos), second group contains zirconia- Upcera core (10 nos) and third group contains Zirconia- Amman Girrbach core (10nos). All the cores were layered with corresponding porcelain. The specimens were stored under artificial saliva for 24 hours and were subjected to shear bond strength test using Instron Universal Testing machine (Instron, model 3382, Japan). The testing machine's computer software automatically recorded and reported the maximum load at which failure occurred.SEM study was performed to determine the type of failure. Results: The results show that the mean shear strength of group I is higher than that of group II and group III. Two-way Analysis of Variance (ANOVA) showed that there was significant difference between group I and other groups (p< 0.005).
- 31 August 2022
- Published by Universidad Tecnica de Manabi in International journal of health sciences
- p. 8676-8685
Open AccessEvaluation of shear bond strength of porcelain to metal and zirconia cores
Aim: The aim of the study is to find out the difference between the shear bond strength values and failure pattern between the metal ceramic system and zirconia core veneering system. Materials and methods: A study was conducted to find out the difference between the shear bond strength values and failure pattern between the metal ceramic system and zirconia core veneering system. A total of 30 samples were divided into three groups. The first group contains metal core(Ni-Cr base metal-10nos), second group contains zirconia- Upcera core (10 nos) and third group contains Zirconia- Amman Girrbach core (10nos). All the cores were layered with corresponding porcelain. The specimens were stored under artificial saliva for 24 hours and were subjected to shear bond strength test using Instron Universal Testing machine (Instron, model 3382, Japan). The testing machine's computer software automatically recorded and reported the maximum load at which failure occurred.SEM study was performed to determine the type of failure. Results: The results show that the mean shear strength of group I is higher than that of group II and group III. Two-way Analysis of Variance (ANOVA) showed that there was significant difference between group I and other groups (p< 0.005).
- Open Access
- 1 April 2017
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 7 (2) , 967-974
An Approach for Big Data to Evolve the Auspicious Information from Cross-Domains
Sentiment analysis is the pre-eminent technology to extract the relevant information from the data domain. In this paper cross domain sentimental classification approach Cross_BOMEST is proposed. Proposed approach will extract †ve words using existing BOMEST technique, with the help of Ms Word Introp, Cross_BOMEST determines †ve words and replaces all its synonyms to escalate the polarity and blends two different domains and detects all the self-sufficient words. Proposed Algorithm is executed on Amazon datasets where two different domains are trained to analyze sentiments of the reviews of the other remaining domain. Proposed approach contributes propitious results in the cross domain analysis and accuracy of 92 % is obtained. Precision and Recall of BOMEST is improved by 16% and 7% respectively by the Cross_BOMEST.
- 1 April 2017
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 7 (2) , 967-974
Open AccessAn Approach for Big Data to Evolve the Auspicious Information from Cross-Domains
Sentiment analysis is the pre-eminent technology to extract the relevant information from the data domain. In this paper cross domain sentimental classification approach Cross_BOMEST is proposed. Proposed approach will extract †ve words using existing BOMEST technique, with the help of Ms Word Introp, Cross_BOMEST determines †ve words and replaces all its synonyms to escalate the polarity and blends two different domains and detects all the self-sufficient words. Proposed Algorithm is executed on Amazon datasets where two different domains are trained to analyze sentiments of the reviews of the other remaining domain. Proposed approach contributes propitious results in the cross domain analysis and accuracy of 92 % is obtained. Precision and Recall of BOMEST is improved by 16% and 7% respectively by the Cross_BOMEST.
- 1 December 2016
- Published by Elsevier in Atmospheric Environment
- Vol. 147, 109-120
Nocturnal surface ozone enhancement over Portugal during winter: Influence of different atmospheric conditions
- 1 December 2016
- Published by Elsevier in Atmospheric Environment
- Vol. 147, 109-120
Nocturnal surface ozone enhancement over Portugal during winter: Influence of different atmospheric conditions
- 1 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 487-491
Review of Grid Computing technology in electrical power systems
With the ever increasing technology integration, the analysis, operation and control of power system is becoming more and more complicated. Grid Computing is one of the solutions for integrating such a large and complicated system. Grid Computing integrates computational resources from various geographical and administrative locations to accomplish a common task. This paper presents a review on the technological developments in the application of Grid Computing to the various sections of the power system. The future of power system Computing and further research areas have also been presented.
- 1 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 487-491
Review of Grid Computing technology in electrical power systems
With the ever increasing technology integration, the analysis, operation and control of power system is becoming more and more complicated. Grid Computing is one of the solutions for integrating such a large and complicated system. Grid Computing integrates computational resources from various geographical and administrative locations to accomplish a common task. This paper presents a review on the technological developments in the application of Grid Computing to the various sections of the power system. The future of power system Computing and further research areas have also been presented.
- 1 January 2016
- Published by Springer Nature in Aerosol and Air Quality Research
- Vol. 16 (1) , 138-152
Surface Ozone Variability and Trend over Urban and Suburban Sites in Portugal
- 1 January 2016
- Published by Springer Nature in Aerosol and Air Quality Research
- Vol. 16 (1) , 138-152
Surface Ozone Variability and Trend over Urban and Suburban Sites in Portugal
- 26 August 2015
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 22 (24) , 20295-20305
Enhancements in nocturnal surface ozone at urban sites in the UK
Analysis of diurnal patterns of surface ozone (O3) at multiple urban sites in the UK shows the occurrence of prominent nocturnal enhancements during the winter months (November–March). Whilst nocturnal surface ozone (NSO) enhancement events have been observed at other locations, this is the first time that such features have been demonstrated to occur in the UK and the second location globally. The observed NSO enhancement events in the UK were found to be so prevalent that they are clearly discernible in monthly diurnal cycles averaged over several years of data. Long-term (2000–2010) analysis of hourly surface ozone data from 18 urban background stations shows a bimodal diurnal variation during the winter months with a secondary nighttime peak around 0300 hours along with the primary daytime peak. For all but one site, the daily maxima NSO concentrations during the winter months exceeded 60 μg/m3 on >20 % of the nights. The highest NSO value recorded was 118 μg/m3. During the months of November, December, and January, the monthly averaged O3 concentrations observed at night (0300 h) even exceeded those observed in the daytime (1300 h). The analysis also shows that these NSO enhancements can last for several hours and were regional in scale, extending across several stations simultaneously. Interestingly, the urban sites in the north of the UK exhibited higher NSO than the sites in the south of the UK, despite their daily maxima being similar. In part, this seems to be related to the sites in the north typically having lower concentrations of nitrogen oxides.
- 26 August 2015
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 22 (24) , 20295-20305
Enhancements in nocturnal surface ozone at urban sites in the UK
Analysis of diurnal patterns of surface ozone (O3) at multiple urban sites in the UK shows the occurrence of prominent nocturnal enhancements during the winter months (November–March). Whilst nocturnal surface ozone (NSO) enhancement events have been observed at other locations, this is the first time that such features have been demonstrated to occur in the UK and the second location globally. The observed NSO enhancement events in the UK were found to be so prevalent that they are clearly discernible in monthly diurnal cycles averaged over several years of data. Long-term (2000–2010) analysis of hourly surface ozone data from 18 urban background stations shows a bimodal diurnal variation during the winter months with a secondary nighttime peak around 0300 hours along with the primary daytime peak. For all but one site, the daily maxima NSO concentrations during the winter months exceeded 60 μg/m3 on >20 % of the nights. The highest NSO value recorded was 118 μg/m3. During the months of November, December, and January, the monthly averaged O3 concentrations observed at night (0300 h) even exceeded those observed in the daytime (1300 h). The analysis also shows that these NSO enhancements can last for several hours and were regional in scale, extending across several stations simultaneously. Interestingly, the urban sites in the north of the UK exhibited higher NSO than the sites in the south of the UK, despite their daily maxima being similar. In part, this seems to be related to the sites in the north typically having lower concentrations of nitrogen oxides.
- Open Access
- 28 April 2015
- Published by Copernicus GmbH in The International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences
- Vol. XL-7/W3, 173-177
Retrieval of Ozone Total Columns over Evora-Portugal Using Remote Sensing Instruments During 2007-2011
Keywords: Ozone, SPATRAM, Remote Sensing, spectromer, DOAS, TOC The present study deals with the retrieval of Ozone (O3) Total Column (TOC) and analysis of its variability over the Observatory of the Geophysics Centre of Évora (CGE-UE) –Portugal (38.5ºN; 7.9 ºW, 300 m a.s.l.) for the period comprised 2007-2011. The data presented in this study are obtained applying the Differential Optical Absorption Spectroscopy (DOAS) methodology to the measurements of diffused spectral sky radiation carried out along the zenith direction performed with the multipurpose UV-Vis. Spectrometer for Atmospheric Tracers Monitoring (SPATRAM) in the 250-900 nm spectral range. This ground-based spectrometer is installed at CGE-UE performing daily and automatic measurements since 2004. Other products of this scanning spectrometer are the vertical profiles of some trace gases (e.g. NO2) and monitoring of air quality. The O3 retrieved with the SPATRAM instrument confirm the typical seasonal cycle for middle latitudes reaching the maximum during the spring and the minimum during the autumn. The ground-based results obtained for O3 column are also compared with data from SCanning Imaging Absorption spectroMeter for Atmospheric CHartographY (SCIAMACHY) and Global Ozone Monitoring Experiment (GOME) instruments aboard ENVISAT and ERS-2 satellites, respectively. The results show a good agreement between the datasets. The main reasons for the observed differences are discussed.
- 28 April 2015
- Published by Copernicus GmbH in The International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences
- Vol. XL-7/W3, 173-177
Open AccessRetrieval of Ozone Total Columns over Evora-Portugal Using Remote Sensing Instruments During 2007-2011
Keywords: Ozone, SPATRAM, Remote Sensing, spectromer, DOAS, TOC The present study deals with the retrieval of Ozone (O3) Total Column (TOC) and analysis of its variability over the Observatory of the Geophysics Centre of Évora (CGE-UE) –Portugal (38.5ºN; 7.9 ºW, 300 m a.s.l.) for the period comprised 2007-2011. The data presented in this study are obtained applying the Differential Optical Absorption Spectroscopy (DOAS) methodology to the measurements of diffused spectral sky radiation carried out along the zenith direction performed with the multipurpose UV-Vis. Spectrometer for Atmospheric Tracers Monitoring (SPATRAM) in the 250-900 nm spectral range. This ground-based spectrometer is installed at CGE-UE performing daily and automatic measurements since 2004. Other products of this scanning spectrometer are the vertical profiles of some trace gases (e.g. NO2) and monitoring of air quality. The O3 retrieved with the SPATRAM instrument confirm the typical seasonal cycle for middle latitudes reaching the maximum during the spring and the minimum during the autumn. The ground-based results obtained for O3 column are also compared with data from SCanning Imaging Absorption spectroMeter for Atmospheric CHartographY (SCIAMACHY) and Global Ozone Monitoring Experiment (GOME) instruments aboard ENVISAT and ERS-2 satellites, respectively. The results show a good agreement between the datasets. The main reasons for the observed differences are discussed.
- Open Access
- 6 July 2014
- Published by Hindawi Limited in Advances in Meteorology
- Vol. 2014, 1-2
Air Pollution, Air Quality, and Climate Change
- 6 July 2014
- Published by Hindawi Limited in Advances in Meteorology
- Vol. 2014, 1-2
Open AccessAir Pollution, Air Quality, and Climate Change
- 1 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Single-phase grid-connected photovoltaic system based on ripple correlation control maximum power point tracking
This work presents a comparison of ripple correlation control maximum power point tracking (MPPT) technique and the modified version of the same MPPT applied to single-phase, single-stage, grid-connected photovoltaic (PV) system, as the technique is fast and suitable for fast changing environmental conditions. Both the techniques are compared on the basis of the time taken to reach (track) the MPP, operating point oscillations about MPP and the dependence of the algorithms, if any, on array configuration and parameters. An LCL-Filter based grid connected inverter with proportional-resonant (PR) current controller is suggested to provide power to the line with unity power factor and the inverter offers much less total harmonic distortion. The focus is on presenting a systematic design procedure for AC current, DC voltage controllers for the VSI and low complexity grid synchronization method. The complete system is numerically simulated in MATLAB and the results are presented for rapidly changing irradiation levels.
- 1 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Single-phase grid-connected photovoltaic system based on ripple correlation control maximum power point tracking
This work presents a comparison of ripple correlation control maximum power point tracking (MPPT) technique and the modified version of the same MPPT applied to single-phase, single-stage, grid-connected photovoltaic (PV) system, as the technique is fast and suitable for fast changing environmental conditions. Both the techniques are compared on the basis of the time taken to reach (track) the MPP, operating point oscillations about MPP and the dependence of the algorithms, if any, on array configuration and parameters. An LCL-Filter based grid connected inverter with proportional-resonant (PR) current controller is suggested to provide power to the line with unity power factor and the inverter offers much less total harmonic distortion. The focus is on presenting a systematic design procedure for AC current, DC voltage controllers for the VSI and low complexity grid synchronization method. The complete system is numerically simulated in MATLAB and the results are presented for rapidly changing irradiation levels.
- 1 June 2013
- Published by Elsevier in Atmospheric Environment
- Vol. 71, 251-259
Nocturnal surface ozone enhancement and trend over urban and suburban sites in Portugal
- 1 June 2013
- Published by Elsevier in Atmospheric Environment
- Vol. 71, 251-259
Nocturnal surface ozone enhancement and trend over urban and suburban sites in Portugal