TMTomi Miettinen

Tomi Miettinen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tomi Miettinen has a total of 27 co-authors. Here are the top co-authors by number of shared publications:

  • Juha Töyräs

    Department of Technical Physics, University of Eastern Finland, Kuopio, Finland; School of Electrical Engineering and Computer Science, The University of Queensland, Brisbane, Australia; Science Service Center, Kuopio University Hospital, Kuopio, Finland

    5 shared publications
  • Kirsi Sipilä

    Research Unit of Population Health, Faculty of Medicine University of Oulu Oulu Finland

    4 shared publications
  • Esa Mervaala

    Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland

    3 shared publications
  • Katja Myllymaa

    Department of Applied Physics, University of Eastern Finland, PO Box 1627, FI-70211, Kuopio, Finland

    3 shared publications
  • Sami Myllymaa

    Department of Applied Physics, University of Eastern Finland, PO Box 1627, FI-70211, Kuopio, Finland

    3 shared publications
  • Sami Myllymaa

    Department of Technical Physics University of Eastern Finland Kuopio Finland

    3 shared publications

Latest Publications

  • Open Access

    Electromyography Frequency Spectrum Is a Better Indicator of Sleep Bruxism Severity Related to Temporomandibular Disorder Pain Than Conventional Masticatory Muscle Activation and Bruxism Time Indices—A Pilot Study

    by Minna Pitkänen, Miro Rytkönen, Tomi Miettinen, Jari Ahlberg, Frank Lobbezoo, Katja Myllymaa, Juha Töyräs, Timo Leppänen, Sami Myllymaa

    Sleep bruxism (SB) has been reportedly associated with temporomandibular disorder (TMD); however, solid evidence is lacking. Previous studies have primarily used traditional metrics, such as the masticatory muscle activity (MMA) index and bruxism time index (BTI) to investigate the link between SB and TMD. However, we aimed to examine how the electromyography (EMG) frequency spectrum is associated with TMD in SB participants. We hypothesised that the EMG signal frequencies during MMA events would be lower in SB participants with TMD pain compared to those without TMD pain. In this exploratory study, we retrospectively analysed home polysomnography data from 44 participants who indicated possible SB. The median signal frequencies and absolute power were calculated using the Fast Fourier Transform of the EMG signals during MMA events. Moreover, the MMA index and BTI were calculated, and all parameters were compared between SB participants with and without TMD pain. The results showed that the absolute power and median frequencies were significantly lower in SB participants with TMD pain compared to those without TMD pain ( p < 0.05), whereas the MMA index and BTI did not differ between the groups ( p > 0.05). These findings suggest that masticatory muscles are getting fatigued in TMD participants with SB and therefore, EMG frequency‐based analysis may provide a promising direction for future assessment of TMD consequences of SB. However, these preliminary results should be validated in future studies involving a larger and more heterogeneous pool of participants.

  • Open Access

    Self-Applied Electrode Set Provides a Clinically Feasible Solution Enabling EEG Recording in Home Sleep Apnea Testing

    by Laura Kalevo, Tomi Miettinen, Akseli Leino, Susanna Westeren-Punnonen, Johanna Sahlman, Esa Mervaala, Juha Toyras, Timo Leppanen, Sami Myllymaa, Katja Myllymaa

    Home sleep apnea testing (HSAT) without electroencephalography (EEG) recording is increasingly used as an alternative to in-laboratory polysomnography for the diagnosis of obstructive sleep apnea (OSA). However, without EEG, electrooculography (EOG), and chin electromyography (EMG) recordings, the OSA severity may be significantly underestimated. Although several ambulatory EEG systems have been recently introduced, no patient-applied systems including EEG, EOG, and chin EMG suitable for home polysomnography are currently in clinical use. We have recently developed and pre-clinically tested a self-applied ambulatory electrode set (AES), consisting of frontal EEG, EOG, and EMG, in subjects with possible sleep bruxism. Now, in this clinical feasibility study, we investigated the signal scorability and usability of the AES as a self-administered sleep assessment approach supplementing the conventional HSAT device. We also investigated how the diagnostic parameters and OSA severity changed when utilizing the AES. Thirty-eight patients (61 % male, 25–78 years) with a clinical suspicion of OSA conducted a single-night, self-administered HSAT with a portable polysomnography device (Nox A1, Nox Medical, Reykjavik, Iceland) supplemented with AES. Only one AES recording failed. The use of AES signals in data analysis significantly affected the median apnea-hypopnea index (AHI), increasing it from 9.4 to 12.7 events/h ( $p < 0.001$ ) compared to the conventional HSAT. Also, in eight patients, the OSA severity class changed to one class worse. Perceived ease of use was well in line with that previously found among healthy volunteers. These results suggest that the AES provides an easy, clinically feasible solution to record EEG as a part of conventional HSAT.


  • Open Access

    Polysomnographic scoring of sleep bruxism events is accurate even in the absence of video recording but unreliable with EMG-only setups

    by Tomi Miettinen, Katja Myllymaa, Anu Muraja-Murro, Susanna Westeren-Punnonen, Taina Hukkanen, Juha Töyräs, Reijo Lappalainen, Esa Mervaala, Kirsi Sipilä, Sami Myllymaa

    Purpose To determine the accuracy of scoring masticatory muscle activity (MMA) events in seven different polysomnography (PSG) setups. Methods Nineteen volunteers (13 females, 6 males, age 31.1 ± 12.9 years, 12 self-proclaimed bruxers) attended one-night PSG recording, supplemented with audio, video, and a separate frontal electroencephalography electrode set (FES). The same examiner scored the MMA events with seven different setups, with varying number of channels available: (1) one, (2) two, and (3) four EMG channels, (4) PSG without audio or video (PSG-N), (5) home PSG with FES and audio (FES-A), (6) PSG with audio (PSG-A), and (7) PSG with audio and video (PSG-AV). A subset (n = 10) of recordings was scored twice to determine intra-scorer reliability. MMA indices and accuracy of scoring the events in different setups were compared against PSG-AV. Results The intra-class correlation coefficient (ICC) between PSG-AV and PSG-A was high (0.940, p < 0.001) as well as for FES-A (0.927, p < 0.001), whereas for PSG-N, it was lower (0.835, p < 0.001); for setups with only EMG channels, coefficients were very low (ICC < 0.100 for all). Intra-examiner reliability was high (ICC > 0.939 for all setups), with the exception of PSG-N (ICC = 0.764, p = 0.002). When comparing against the MMA events scored in PSG-AV, the sensitivity of MMA event recognition for PSG-A was 78.5% and specificity 95.5%, which were substantially higher than sensitivity (52.0%) and specificity (87.2%) of PSG-N. Conclusions MMA event scoring accuracy with PSG-A or FES-A is almost comparable to PSG-AV. Since precise event recognition is essential for accurate MMA scoring, it is evident that one cannot rely exclusively on EMG.


  • Home Polysomnography Reveals a First-Night Effect in Patients With Low Sleep Bruxism Activity

    by Tomi Miettinen, Katja Myllymaa, Taina Hukkanen, Juha Töyräs, Kirsi Sipilä, Sami Myllymaa

    To examine the presence of a first-night effect (FNE) and the level of internight variability in sleep bruxism (SB) activity when a self-applicable electrode set is used in home polysomnography (PSG) in a sample of subjects with possible SB. Fourteen females and two males aged 38.3 ± 9.1 years (mean ± standard deviation) with self-reported SB underwent home-PSG on three consecutive nights. The subjects applied PSG sensors themselves, including self-applicable electrode sets used to record sleep and masseter muscle activity. Repeated-measures analysis of variance was used to compare SB and sleep variables between the nights. Surprisingly, there were statistically significant elevations in the rhythmic masticatory muscle activity (RMMA) episode index (P = .009), burst index (P = .016), and bruxism time index (P = .049) throughout the course of 3 nights. More bruxers were diagnosed on the second (6 bruxers, ≥ 2 episodes/h) and third night (7 bruxers) compared to the first night (2 bruxers). Most subjects (14/16) had their highest RMMA index on the second or third night. The mean coefficient of variation for RMMA episode index was 50.7%. No statistically significant differences were detected in other sleep variables. The results indicate that a FNE may be present in SB activity, possibly lasting several nights in some subjects. Furthermore, FNE appears to be combined with high internight variability of SB activity without indications of internight changes in sleep macrostructure. To confirm the level of ongoing SB activity, several nights of PSG may be required, especially in subjects with low first-night SB activity. A commentary on this article appears in this issue on page 1281.


  • Success Rate and Technical Quality of Home Polysomnography With Self-Applicable Electrode Set in Subjects With Possible Sleep Bruxism

    by Tomi Miettinen, Katja Myllymaa, Susanna Westeren-Punnonen, Jari Ahlberg, Taina Hukkanen, Juha Toyras, Reijo Lappalainen, Esa Mervaala, Kirsi Sipila, Sami Myllymaa

    Using sleep laboratory polysomnography (PSG) is restricted for the diagnosis of only the most severe sleep disorders due to its low availability and high cost. Home PSG is more affordable, but applying conventional electroencephalography (EEG) electrodes increases its overall complexity and lowers the availability. Simple, self-administered single-channel EEG monitors on the other hand suffer from poor reliability. In this study, we aimed to quantify the reliability of self-administrated home PSG recordings conducted with a newly designed ambulatory electrode set (AES) that enables multichannel EEG, electrooculography, electromyography, and electrocardiography recordings. We assessed the sleep study success rate and technical quality of the recordings performed in subjects with possible sleep bruxism (SB). Thirty-two females and five males aged 39.6 ± 11.6 years (mean±SD) with self-reported SB were recruited in the study. Self-administrated home PSG recordings with two AES designs were conducted (n = 19 and 21). The technical quality of the recordings was graded based on the proportion of interpretable data. Technical failure rate for AES (both designs) was 5% and SB was scorable for 96.9% of all recorded data. Only one recording failed due to mistakes in self-applying the AES. We found that the proportion of good quality self-administrated EEG recordings is significantly higher when multiple channels are used compared to using a single channel. Sleep study success rates and proportion of recordings with high quality interpretable data from EEG channels of AES were comparable to that of conventional home PSG. Self-applicable AES has potential to become a reliable tool for widely available home PSG.


  • Open Access

    Screen‐printed ambulatory electrode set enables accurate diagnostics of sleep bruxism

    by Tomi Miettinen, Katja Myllymaa, Anu Muraja‐Murro, Susanna Westeren‐Punnonen, Taina Hukkanen, Juha Töyräs, Reijo Lappalainen, Esa Mervaala, Kirsi Sipilä, Sami Myllymaa

    Summary: Currently, definite diagnosis of sleep bruxism requires polysomnography. However, it is restrictedly available, and too cumbersome and expensive for the purpose. The aim of this study was to introduce an ambulatory electrode set and evaluate its feasibility for more cost‐effective diagnostics of sleep bruxism. Six self‐assessed bruxers (one male, five females; aged 21–58 years) and six healthy controls (four males, two females, aged 21–25 years) underwent a standard polysomnographic study and a concurrent study with the ambulatory electrode set. Bruxism events, cortical arousals and sleep stages were scored for the two montages separately in a random order, and obtained sleep parameters were compared. In addition, the significance of video recording and sleep stage scoring for the diagnostic accuracy of ambulatory electrode set was determined. Ambulatory electrode set yielded similar diagnoses as standard polysomnography in all subjects. However, compared with standard polysomnography the median (interquartile range) tonic bruxism event index was significantly higher in the control group [+0.38 (+0.08 to +0.56) events per hour, P = 0.046], and the phasic bruxism event index was significantly lower in the bruxer group [−0.44 (−1.30 to +0.07) events per hour, P = 0.046]. Exclusion of video recording and both video recording and sleep stage scoring from analysis increased overestimation of the tonic bruxism event index in the control group +0.86 (+0.42 to +1.03) and +1.19 (+0.55 to +1.39) events per hour, P = 0.046 and P = 0.028, respectively], resulting in one misdiagnosed control subject. To conclude, ambulatory electrode set is a sensitive method for ambulatory diagnostics of sleep bruxism, and video recording and sleep stage scoring help reaching the highest specificity of sleep bruxism diagnostics.