Lawrence C. Siegel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lawrence C. Siegel has a total of 151 co-authors. Here are the top co-authors by number of shared publications:
John H. Stevens
From the Department of Anesthesia (L.C.S.), Division of Cardiology (F.G. St. G.), and Department of Cardiothoracic Surgery (J.H.S., M.F.P., T.A.B., B.A.R., W.S.P.), Stanford (Calif) University School of Medicine, and the Division of Cardiothoracic Surgery, Palo Alto (Calif) Veterans Affairs Health Care System (M.F.P., T.A.B.).
8 shared publicationsRonald G. Pearl
8 shared publicationsMario F. Pompili
From the Department of Anesthesia (L.C.S.), Division of Cardiology (F.G. St. G.), and Department of Cardiothoracic Surgery (J.H.S., M.F.P., T.A.B., B.A.R., W.S.P.), Stanford (Calif) University School of Medicine, and the Division of Cardiothoracic Surgery, Palo Alto (Calif) Veterans Affairs Health Care System (M.F.P., T.A.B.).
7 shared publicationsBruce A. Reitz
From the Department of Anesthesia (L.C.S.), Division of Cardiology (F.G. St. G.), and Department of Cardiothoracic Surgery (J.H.S., M.F.P., T.A.B., B.A.R., W.S.P.), Stanford (Calif) University School of Medicine, and the Division of Cardiothoracic Surgery, Palo Alto (Calif) Veterans Affairs Health Care System (M.F.P., T.A.B.).
6 shared publicationsFrederick G. St. Goar
From the Department of Anesthesia (L.C.S.), Division of Cardiology (F.G. St. G.), and Department of Cardiothoracic Surgery (J.H.S., M.F.P., T.A.B., B.A.R., W.S.P.), Stanford (Calif) University School of Medicine, and the Division of Cardiothoracic Surgery, Palo Alto (Calif) Veterans Affairs Health Care System (M.F.P., T.A.B.).
6 shared publicationsThomas A. Burdon
From the Department of Anesthesia (L.C.S.), Division of Cardiology (F.G. St. G.), and Department of Cardiothoracic Surgery (J.H.S., M.F.P., T.A.B., B.A.R., W.S.P.), Stanford (Calif) University School of Medicine, and the Division of Cardiothoracic Surgery, Palo Alto (Calif) Veterans Affairs Health Care System (M.F.P., T.A.B.).
6 shared publications
Latest Publications
- 12 May 2016
- Published by Springer Nature in Journal of Anesthesia
- Vol. 30 (4) , 707-710
Use of a home positive airway pressure device during intraoperative monitored anesthesia care for outpatient surgery
Perioperative positive airway pressure (PAP) is recommended by the American Society of Anesthesiologists for patients with obstructive sleep apnea, but a readily available and personalized intraoperative delivery system does not exist. We present the successful use of a patient's own nasal PAP machine in the operating room during outpatient foot surgery which required addition of a straight adaptor for oxygen delivery and careful positioning of the gas sampling line to permit end-tidal carbox dioxide monitoring. Home PAP machines may provide a potential alternative to more invasive methods of airway management for patients with obstructive sleep apnea under moderate sedation.
- 12 May 2016
- Published by Springer Nature in Journal of Anesthesia
- Vol. 30 (4) , 707-710
Use of a home positive airway pressure device during intraoperative monitored anesthesia care for outpatient surgery
Perioperative positive airway pressure (PAP) is recommended by the American Society of Anesthesiologists for patients with obstructive sleep apnea, but a readily available and personalized intraoperative delivery system does not exist. We present the successful use of a patient's own nasal PAP machine in the operating room during outpatient foot surgery which required addition of a straight adaptor for oxygen delivery and careful positioning of the gas sampling line to permit end-tidal carbox dioxide monitoring. Home PAP machines may provide a potential alternative to more invasive methods of airway management for patients with obstructive sleep apnea under moderate sedation.
- 21 September 2015
- Published by SAGE Publications in Seminars in Cardiothoracic and Vascular Anesthesia
- Vol. 20 (2) , 133-140
Design and Implementation of a Perioperative Surgical Home at a Veterans Affairs Hospital
The innovative Perioperative Surgical Home model aims to optimize the outcomes of surgical patients by leveraging the expertise and leadership of physician anesthesiologists, but there is a paucity of practical examples to follow. Veterans Affairs health care, the largest integrated system in the United States, may be the ideal environment in which to explore this model. We present our experience implementing Perioperative Surgical Home at one tertiary care university-affiliated Veterans Affairs hospital. This process involved initiating consistent postoperative patient follow-up beyond the postanesthesia care unit, a focus on improving in-hospital acute pain management, creation of an accessible database to track outcomes, developing new clinical pathways, and recruiting additional staff. Today, our Perioperative Surgical Home facilitates communication between various services involved in the care of surgical patients, monitoring of patient outcomes, and continuous process improvement.
- 21 September 2015
- Published by SAGE Publications in Seminars in Cardiothoracic and Vascular Anesthesia
- Vol. 20 (2) , 133-140
Design and Implementation of a Perioperative Surgical Home at a Veterans Affairs Hospital
The innovative Perioperative Surgical Home model aims to optimize the outcomes of surgical patients by leveraging the expertise and leadership of physician anesthesiologists, but there is a paucity of practical examples to follow. Veterans Affairs health care, the largest integrated system in the United States, may be the ideal environment in which to explore this model. We present our experience implementing Perioperative Surgical Home at one tertiary care university-affiliated Veterans Affairs hospital. This process involved initiating consistent postoperative patient follow-up beyond the postanesthesia care unit, a focus on improving in-hospital acute pain management, creation of an accessible database to track outcomes, developing new clinical pathways, and recruiting additional staff. Today, our Perioperative Surgical Home facilitates communication between various services involved in the care of surgical patients, monitoring of patient outcomes, and continuous process improvement.
- 1 July 2014
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 37 (7) , 1237-1247
Examining the Mechanism of Action of a New Device Using Oral Pressure Therapy for the Treatment of Obstructive Sleep Apnea
S and full research articles published in SLEEP, the official journal of the APSS. Sleep and sleep disorder scientific findings.
- 1 July 2014
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 37 (7) , 1237-1247
Examining the Mechanism of Action of a New Device Using Oral Pressure Therapy for the Treatment of Obstructive Sleep Apnea
S and full research articles published in SLEEP, the official journal of the APSS. Sleep and sleep disorder scientific findings.
- 1 September 2013
- Published by Elsevier in Sleep Medicine
- Vol. 14 (9) , 830-837
A multicenter evaluation of oral pressure therapy for the treatment of obstructive sleep apnea
- 1 September 2013
- Published by Elsevier in Sleep Medicine
- Vol. 14 (9) , 830-837
A multicenter evaluation of oral pressure therapy for the treatment of obstructive sleep apnea
- Open Access
- 1 May 2013
- Published by Taylor & Francis in Nature and Science of Sleep
- Vol. 5, 53-59
Oral pressure therapy for treatment of obstructive sleep apnea: clinical feasibility
Purpose: This feasibility study examined the initial-use safety and effectiveness of a new noninvasive oral pressure therapy (OPT) system developed to treat obstructive sleep apnea (OSA). Methods: The OPT system consists of a console that connects with flexible tubing to a premanufactured polymer mouthpiece. Through the mouthpiece, a pump in the console creates oral vacuum intended to move the soft palate anteriorly to decrease obstruction of the airway during sleep. The mouthpiece was produced in ten different sizes to accommodate a range of oral dimensions. Subjects with OSA in this single-center, single-night study underwent a polysomnography (PSG) study at baseline, followed by PSG during use of OPT. Results: Fifty-six men and 20 women, aged 50.8 ± 12.0 years (mean ± standard deviation [SD]), had OSA with apnea–hypopnea indices (AHI) greater than five events per hour at baseline. Body weight averaged 98.0 ± 18.2 kg (mean ± SD), body mass index ranged from 22.6 kg/m2 to 57.9 kg/m2 and averaged 32.5 ± 5.8 kg/m2 (mean ± SD). OPT was generally well tolerated without any serious adverse events. Baseline AHI was 38.7 ± 27.5 events/hour (mean ± SD) and was reduced with treatment to 24.6 ± 25.7 events/hour (P < 0.001, Cohen's d 0.53). Treatment produced AHI less than or equal to ten events/hour in 38% of the subjects. Oxygen desaturation index was 30.1 ± 23.7 events/hour at baseline versus 15.8 ± 19.1 events/hour with treatment (P < 0.001, Cohen's d 0.66). The minimum oxygen saturation increased with treatment from 77.9 ± 8.3 to 82.2 ± 7.9 (P < 0.001, Cohen's d 0.53). Stage-N1 sleep shifts, total sleep-stage shifts, and awakenings were significantly reduced with treatment. Conclusion: This single-center, single-night feasibility study demonstrates that OPT can improve OSA in certain subjects identifiable by PSG during systematic usage. In appropriately responsive patients, OPT shows potential as a clinically useful new alternative for treatment of OSA without the need for custom manufacture of an oral device component.
- 1 May 2013
- Published by Taylor & Francis in Nature and Science of Sleep
- Vol. 5, 53-59
Open AccessOral pressure therapy for treatment of obstructive sleep apnea: clinical feasibility
Purpose: This feasibility study examined the initial-use safety and effectiveness of a new noninvasive oral pressure therapy (OPT) system developed to treat obstructive sleep apnea (OSA). Methods: The OPT system consists of a console that connects with flexible tubing to a premanufactured polymer mouthpiece. Through the mouthpiece, a pump in the console creates oral vacuum intended to move the soft palate anteriorly to decrease obstruction of the airway during sleep. The mouthpiece was produced in ten different sizes to accommodate a range of oral dimensions. Subjects with OSA in this single-center, single-night study underwent a polysomnography (PSG) study at baseline, followed by PSG during use of OPT. Results: Fifty-six men and 20 women, aged 50.8 ± 12.0 years (mean ± standard deviation [SD]), had OSA with apnea–hypopnea indices (AHI) greater than five events per hour at baseline. Body weight averaged 98.0 ± 18.2 kg (mean ± SD), body mass index ranged from 22.6 kg/m2 to 57.9 kg/m2 and averaged 32.5 ± 5.8 kg/m2 (mean ± SD). OPT was generally well tolerated without any serious adverse events. Baseline AHI was 38.7 ± 27.5 events/hour (mean ± SD) and was reduced with treatment to 24.6 ± 25.7 events/hour (P < 0.001, Cohen's d 0.53). Treatment produced AHI less than or equal to ten events/hour in 38% of the subjects. Oxygen desaturation index was 30.1 ± 23.7 events/hour at baseline versus 15.8 ± 19.1 events/hour with treatment (P < 0.001, Cohen's d 0.66). The minimum oxygen saturation increased with treatment from 77.9 ± 8.3 to 82.2 ± 7.9 (P < 0.001, Cohen's d 0.53). Stage-N1 sleep shifts, total sleep-stage shifts, and awakenings were significantly reduced with treatment. Conclusion: This single-center, single-night feasibility study demonstrates that OPT can improve OSA in certain subjects identifiable by PSG during systematic usage. In appropriately responsive patients, OPT shows potential as a clinically useful new alternative for treatment of OSA without the need for custom manufacture of an oral device component.
- Open Access
- 26 November 2012
- Published by SAGE Publications in Therapeutic Advances in Respiratory Disease
- Vol. 7 (1) , 3-12
A feasibility evaluation of oral pressure therapy for the treatment of obstructive sleep apnea
This feasibility study examined the initial-use safety and potential utility of a novel noninvasive oral pressure therapy (OPT) system designed to reduce airway obstruction during sleep. This was a single-center, proof-of-concept, single-treatment-night study in which subjects with obstructive sleep apnea (OSA) underwent a baseline polysomnography (PSG) study followed by PSG during use of an OPT system. The OPT system is composed of a bedside console, a polymer mouthpiece, and a flexible tube connecting the mouthpiece to the console. The console contains a pump that creates vacuum intended to pull the soft palate anteriorly and stabilize the tongue to reduce obstruction during sleep. Fifty-four men and 17 women, aged 53.2 ± 11.5 years (mean ± SD) had a baseline apnea–hypopnea index (AHI) greater than 5 events per hour. OPT was generally well tolerated with no serious adverse events. OPT significantly decreased AHI from 34.4 ± 28.9 events per hour (mean ± SD) at baseline to 20.7 ± 23.3 (p < 0.001). Treatment produced an AHI less than 10 in 48% of the subjects. OPT significantly improved oxygen desaturation index (p < 0.001) and increased the percentage of the night with oxygen saturation of 90% or greater (p = 0.028). Stage-N1 sleep shifts, total sleep-stage shifts, awakenings and the percentage of sleep time spent in N1 sleep were significantly reduced with treatment. This proof-of-concept study suggests that OPT can produce clinically relevant relief of OSA in certain subjects who are readily identified by PSG during trial use of the noninvasive system. OPT shows promise as a new treatment option for OSA in appropriate patients.
- 26 November 2012
- Published by SAGE Publications in Therapeutic Advances in Respiratory Disease
- Vol. 7 (1) , 3-12
Open AccessA feasibility evaluation of oral pressure therapy for the treatment of obstructive sleep apnea
This feasibility study examined the initial-use safety and potential utility of a novel noninvasive oral pressure therapy (OPT) system designed to reduce airway obstruction during sleep. This was a single-center, proof-of-concept, single-treatment-night study in which subjects with obstructive sleep apnea (OSA) underwent a baseline polysomnography (PSG) study followed by PSG during use of an OPT system. The OPT system is composed of a bedside console, a polymer mouthpiece, and a flexible tube connecting the mouthpiece to the console. The console contains a pump that creates vacuum intended to pull the soft palate anteriorly and stabilize the tongue to reduce obstruction during sleep. Fifty-four men and 17 women, aged 53.2 ± 11.5 years (mean ± SD) had a baseline apnea–hypopnea index (AHI) greater than 5 events per hour. OPT was generally well tolerated with no serious adverse events. OPT significantly decreased AHI from 34.4 ± 28.9 events per hour (mean ± SD) at baseline to 20.7 ± 23.3 (p < 0.001). Treatment produced an AHI less than 10 in 48% of the subjects. OPT significantly improved oxygen desaturation index (p < 0.001) and increased the percentage of the night with oxygen saturation of 90% or greater (p = 0.028). Stage-N1 sleep shifts, total sleep-stage shifts, awakenings and the percentage of sleep time spent in N1 sleep were significantly reduced with treatment. This proof-of-concept study suggests that OPT can produce clinically relevant relief of OSA in certain subjects who are readily identified by PSG during trial use of the noninvasive system. OPT shows promise as a new treatment option for OSA in appropriate patients.
- 1 May 2012
- Published by Oxford University Press (OUP)
- p. A6810
Oral Pressure Therapy Improves Obstructive Sleep Apnea
- 1 May 2012
- Published by Oxford University Press (OUP)
- p. A6810
Oral Pressure Therapy Improves Obstructive Sleep Apnea
- 1 January 2001
- Vol. 4 (1) , 40-6
Predictors of operative time in multicenter port-access valve registry: institutional differences in learning.
The predictors of operative time and the effects of learning in isolated valve operations using port-access techniques have not been defined. Analysis of covariance was used to examine the determinants of procedure time, pump time, and aortic clamp time. In the largest prospective, registry of patients undergoing isolated aortic valve replacement (AVR, N=199), mitral repair (MVP, N=307), or mitral replacement (MVR, N=232) using port-access techniques 1997-1999 at 27 institutions. Institutional case volume ranged from one to 214 (median 6). Operative time was longer in redo procedures (5.3 +/- 1.6 vs. 4.4 +/- 1.3 hr, p = 0.0001), longer with MVP or MVR vs. AVR (4.8 +/- 1.2 vs. 5.0 +/- 1.5 vs. 3.8 +/- 1.2 hr, p = 0.0001), and decreased with case number (mean decrease 1.00 +/- 0.19 min/case, p = 0.04). Operative time also varied between institutions (p = 0.001). Rate of learning (decrease in time per case) varied significantly between institutions only for MVP (p = 0.03). Similar analysis showed that pump time and clamp times did not significantly change over time (p > 0.17) but varied significantly between institutions. Institutional volume did not affect operative, pump, or clamp times or rate of learning (decrease in operative time/case). These prospective registry data demonstrate that, for port-access valve procedures, procedure times continue to improve (learning) even after 100 cases. Procedure time and learning are affected by institutional differences and by the type of procedure, but are little affected by institutional volume. This data provides a model to understand learning of new surgical procedures, and this data suggests that port-access valve procedures can be mastered by a variety of institutions.
- 1 January 2001
- Vol. 4 (1) , 40-6
Predictors of operative time in multicenter port-access valve registry: institutional differences in learning.
The predictors of operative time and the effects of learning in isolated valve operations using port-access techniques have not been defined. Analysis of covariance was used to examine the determinants of procedure time, pump time, and aortic clamp time. In the largest prospective, registry of patients undergoing isolated aortic valve replacement (AVR, N=199), mitral repair (MVP, N=307), or mitral replacement (MVR, N=232) using port-access techniques 1997-1999 at 27 institutions. Institutional case volume ranged from one to 214 (median 6). Operative time was longer in redo procedures (5.3 +/- 1.6 vs. 4.4 +/- 1.3 hr, p = 0.0001), longer with MVP or MVR vs. AVR (4.8 +/- 1.2 vs. 5.0 +/- 1.5 vs. 3.8 +/- 1.2 hr, p = 0.0001), and decreased with case number (mean decrease 1.00 +/- 0.19 min/case, p = 0.04). Operative time also varied between institutions (p = 0.001). Rate of learning (decrease in time per case) varied significantly between institutions only for MVP (p = 0.03). Similar analysis showed that pump time and clamp times did not significantly change over time (p > 0.17) but varied significantly between institutions. Institutional volume did not affect operative, pump, or clamp times or rate of learning (decrease in operative time/case). These prospective registry data demonstrate that, for port-access valve procedures, procedure times continue to improve (learning) even after 100 cases. Procedure time and learning are affected by institutional differences and by the type of procedure, but are little affected by institutional volume. This data provides a model to understand learning of new surgical procedures, and this data suggests that port-access valve procedures can be mastered by a variety of institutions.
- 1 September 2000
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 70 (3) , 1054-1059
Predictors of outcome in a multicenter port-access valve registry
- 1 September 2000
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 70 (3) , 1054-1059
Predictors of outcome in a multicenter port-access valve registry
- Open Access
- 1 April 2000
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 14 (2) , 171-176
Institutional variability in red blood cell conservation practices for coronary artery bypass graft surgery
- 1 April 2000
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 14 (2) , 171-176
Open AccessInstitutional variability in red blood cell conservation practices for coronary artery bypass graft surgery