Alfonso William Mauro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alfonso William Mauro has a total of 93 co-authors. Here are the top co-authors by number of shared publications:
- Rita Mastrullo
University of Naples Federico II
25 shared publications - Giuseppe Peter Vanoli
Dipartimento di Medicina e Scienze della Salute DIMES, Università degli Studi del Molise
17 shared publications - Luca Viscito
Department of Industrial Engineering, Università degli Studi di Napoli–Federico II, P.le Tecchio 80, 80125 Naples, Italy
16 shared publications R. Mastrullo
Department of Industrial Engineering, Universitá degli Studi di Napoli Federico II, P.le Tecchio 80, 80125, Napoli, Italy
10 shared publicationsJ.R. Thome
6 shared publicationsR Mastrullo
Department of Industrial Engineering, Federico II University of Naples, P.le Tecchio 80, 80125 Naples (Italy)
6 shared publications
Latest Publications
- Open Access
- 14 May 2026
- Published by MDPI AG in Journal of Experimental and Theoretical Analyses
- Vol. 4 (2) , 18
Impact of Sensor Accuracy and Model Calibration on Simulation of Heat Pumps with Refrigerant Leakage Faults
Soft operational faults can noticeably degrade the performance of heat pumps and influence key monitored variables, emphasizing the need for reliable Fault Detection, Diagnosis, and Evaluation (FDDE) strategies. The BEYOND project tackles this challenge by analyzing simultaneous soft faults using a calibrated simulation model informed by data from a dedicated test rig. Achieving reliable results depends on both accurate measurements and proper model calibration. However, sensor uncertainty and errors in sub-models and correlations calibration can compromise model reliability. This work investigates the influence of measurement accuracy and calibration quality on both experimental variables and simulation outcomes for a residential air-to-water heat pump operating in cooling mode, with particular focus on refrigerant charge estimation. Two sensor configurations—“low accuracy” and “high accuracy”—are assessed, representing commercial- and laboratory-grade instruments, respectively, along with two corresponding calibration strategies. In the low-accuracy case, uncertainties around 10% were found for cooling capacity, energy efficiency ratio, and refrigerant mass flow rate, whereas high-accuracy setups reduced these to approximately 3%. Ultimately, the comparison between experimental and model-derived uncertainties confirms that achieving reliable predictions requires a balanced investment in both high-quality instrumentation and careful model calibration. Overall, this study serves as a crucial tool during the preliminary design of an experimental setup, assisting in the selection of a sensor suite that ensures not only the reliability of secondary variables and KPIs but also a robust and accurate calibration of physics-based models using the acquired experimental data.
- 14 May 2026
- Published by MDPI AG in Journal of Experimental and Theoretical Analyses
- Vol. 4 (2) , 18
Open AccessImpact of Sensor Accuracy and Model Calibration on Simulation of Heat Pumps with Refrigerant Leakage Faults
Soft operational faults can noticeably degrade the performance of heat pumps and influence key monitored variables, emphasizing the need for reliable Fault Detection, Diagnosis, and Evaluation (FDDE) strategies. The BEYOND project tackles this challenge by analyzing simultaneous soft faults using a calibrated simulation model informed by data from a dedicated test rig. Achieving reliable results depends on both accurate measurements and proper model calibration. However, sensor uncertainty and errors in sub-models and correlations calibration can compromise model reliability. This work investigates the influence of measurement accuracy and calibration quality on both experimental variables and simulation outcomes for a residential air-to-water heat pump operating in cooling mode, with particular focus on refrigerant charge estimation. Two sensor configurations—“low accuracy” and “high accuracy”—are assessed, representing commercial- and laboratory-grade instruments, respectively, along with two corresponding calibration strategies. In the low-accuracy case, uncertainties around 10% were found for cooling capacity, energy efficiency ratio, and refrigerant mass flow rate, whereas high-accuracy setups reduced these to approximately 3%. Ultimately, the comparison between experimental and model-derived uncertainties confirms that achieving reliable predictions requires a balanced investment in both high-quality instrumentation and careful model calibration. Overall, this study serves as a crucial tool during the preliminary design of an experimental setup, assisting in the selection of a sensor suite that ensures not only the reliability of secondary variables and KPIs but also a robust and accurate calibration of physics-based models using the acquired experimental data.
- Open Access
- 1 December 2025
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3143 (1)
Optimal chiller loading analysis for a multi-chiller Computer Room Air Handler (CRAH) system feeding a data center
Data centers represent the key facilities in the global digital transition framework, but their increasing energy demand sets a significant environmental challenge, due to the huge energy consumption related to the cooling system. On this regard, this work focuses on the energy optimization of a Computer Room Air Handler (CRAH) system powered by a multi-chiller setup, consisting of three chillers working in parallel. Within this configuration, the user load may theoretically be satisfied with infinite combinations of the individual chillers part load ratios (PLR), potentially leading to non-optimized performance and with a considerable number of on/off cycles that hinder the machine lifetime. Performance maps for each chiller were developed with dedicated models, considering the total Part Load Ratio (PLR) and the environmental conditions (wet bulb temperature) of the air entering the cooling tower. Finally, a user-based individual PLR adaptation strategy was therefore developed to find a suitable compromise between the minimization of the total energy consumption and the on/off machine cycles.
- 1 December 2025
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3143 (1)
Open AccessOptimal chiller loading analysis for a multi-chiller Computer Room Air Handler (CRAH) system feeding a data center
Data centers represent the key facilities in the global digital transition framework, but their increasing energy demand sets a significant environmental challenge, due to the huge energy consumption related to the cooling system. On this regard, this work focuses on the energy optimization of a Computer Room Air Handler (CRAH) system powered by a multi-chiller setup, consisting of three chillers working in parallel. Within this configuration, the user load may theoretically be satisfied with infinite combinations of the individual chillers part load ratios (PLR), potentially leading to non-optimized performance and with a considerable number of on/off cycles that hinder the machine lifetime. Performance maps for each chiller were developed with dedicated models, considering the total Part Load Ratio (PLR) and the environmental conditions (wet bulb temperature) of the air entering the cooling tower. Finally, a user-based individual PLR adaptation strategy was therefore developed to find a suitable compromise between the minimization of the total energy consumption and the on/off machine cycles.
- Open Access
- 1 December 2025
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3143 (1)
Experimental characterization of a carbon-dioxide dual source heat pump
Heat pumps represent a key factor in the electrification of heating and cooling and are crucial for the energy transition towards low-carbon systems. The adoption of innovative solutions, such as multi-source configurations and low-GWP refrigerants like carbon dioxide also improve sustainability and system efficiency. The studied system is a dual-source (air/sun), reversible carbon-dioxide heat pump installed at the ENEA Research Center in Casaccia. The prototype, with about 10 kW of heating capacity, is designed to provide chilled water during the summer season and hot water for both space heating in winter and sanitary water production and integrates two strings of five photovoltaic thermal hybrid solar panels to both produce electricity and assist the evaporation process. This paper presents dynamic heating-mode tests for space heating in climatic zone D, focusing on the cooling effect of the panels and its impact on their performance. Steady-state tests validated the dynamic tests findings, showing an average improvement in electrical efficiency of 8.06%. Finally, thermal imaging on panel surfaces with the heat pump off and on revealed a surface temperature drop from 50°C to 25°C corresponding to roughly 0.52% efficiency gain per degree Celsius reduction.
- 1 December 2025
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3143 (1)
Open AccessExperimental characterization of a carbon-dioxide dual source heat pump
Heat pumps represent a key factor in the electrification of heating and cooling and are crucial for the energy transition towards low-carbon systems. The adoption of innovative solutions, such as multi-source configurations and low-GWP refrigerants like carbon dioxide also improve sustainability and system efficiency. The studied system is a dual-source (air/sun), reversible carbon-dioxide heat pump installed at the ENEA Research Center in Casaccia. The prototype, with about 10 kW of heating capacity, is designed to provide chilled water during the summer season and hot water for both space heating in winter and sanitary water production and integrates two strings of five photovoltaic thermal hybrid solar panels to both produce electricity and assist the evaporation process. This paper presents dynamic heating-mode tests for space heating in climatic zone D, focusing on the cooling effect of the panels and its impact on their performance. Steady-state tests validated the dynamic tests findings, showing an average improvement in electrical efficiency of 8.06%. Finally, thermal imaging on panel surfaces with the heat pump off and on revealed a surface temperature drop from 50°C to 25°C corresponding to roughly 0.52% efficiency gain per degree Celsius reduction.
- Open Access
State-of-the-Art Methodologies for Self-Fault Detection, Diagnosis and Evaluation (FDDE) in Residential Heat Pumps
The European Union’s 2050 targets for decarbonization and electrification are promoting the widespread integration of heat pumps for space heating, cooling, and domestic hot water in buildings. However, their energy and environmental performance can be significantly compromised by soft faults, such as refrigerant leakage or heat exchanger fouling, which may reduce system efficiency by up to 25%, even with maintenance intervals every two years. As a result, the implementation of self-fault detection, diagnosis, and evaluation (FDDE) tools based on operational data has become increasingly important. The complexity and added value of these tools grow as they progress from simple fault detection to quantitative fault evaluation, enabling more accurate and timely maintenance strategies. Direct fault measurements are often unfeasible due to spatial, economic, or intrusiveness constraints, thus requiring indirect methods based on low-cost and accessible measurements. In such cases, overlapping fault symptoms may create diagnostic ambiguities. Moreover, the accuracy of FDDE approaches depends on the type and number of sensors deployed, which must be balanced against cost considerations. This paper provides a comprehensive review of current FDDE methodologies for heat pumps, drawing insights from the academic literature, patent databases, and commercial products. Finally, the role of artificial intelligence in enhancing fault evaluation capabilities is discussed, along with emerging challenges and future research directions.
Open AccessState-of-the-Art Methodologies for Self-Fault Detection, Diagnosis and Evaluation (FDDE) in Residential Heat Pumps
The European Union’s 2050 targets for decarbonization and electrification are promoting the widespread integration of heat pumps for space heating, cooling, and domestic hot water in buildings. However, their energy and environmental performance can be significantly compromised by soft faults, such as refrigerant leakage or heat exchanger fouling, which may reduce system efficiency by up to 25%, even with maintenance intervals every two years. As a result, the implementation of self-fault detection, diagnosis, and evaluation (FDDE) tools based on operational data has become increasingly important. The complexity and added value of these tools grow as they progress from simple fault detection to quantitative fault evaluation, enabling more accurate and timely maintenance strategies. Direct fault measurements are often unfeasible due to spatial, economic, or intrusiveness constraints, thus requiring indirect methods based on low-cost and accessible measurements. In such cases, overlapping fault symptoms may create diagnostic ambiguities. Moreover, the accuracy of FDDE approaches depends on the type and number of sensors deployed, which must be balanced against cost considerations. This paper provides a comprehensive review of current FDDE methodologies for heat pumps, drawing insights from the academic literature, patent databases, and commercial products. Finally, the role of artificial intelligence in enhancing fault evaluation capabilities is discussed, along with emerging challenges and future research directions.
- Open Access
Physical Model for the Simulation of an Air Handling Unit Employed in an Automotive Production Process: Calibration Procedure and Potential Energy Saving
A meticulous thermo-hygrometric control is essential for various industrial production processes, particularly those involving the painting phases of body-in-white, in which the air temperature and relative humidity in production boots must be limited in strict intervals to ensure the high quality of the final product. However, traditional proportional integrative derivative (PID) controllers may result in non-optimal control strategies, leading to energy wastage due to response delays and unnecessary superheatings. In this regard, predictive models designed for control can significantly aid in achieving all the targets set by the European Union. This paper focuses on the development of a predictive model for the energy consumption of an air handling unit (AHU) used in the paint-shop area of an automotive production process. The model, developed in MATLAB 2024b, is based on mass and energy balances within each component, and phenomenological equations for heat exchangers. It enables the evaluation of thermal powers and water mass flow rates required to process an inlet air flow rate to achieve a target condition for the temperature and relative humidity. The model was calibrated and validated using experimental data of a real case study of an automotive production process, obtaining mean errors of 16% and 31% for the hot and cold heat exchangers, respectively, in predicting the water mass flow rate. Additionally, a control logic based on six regulation thermo-hygrometric zones was developed, which depended on the external conditions of temperature and relative humidity. Finally, as the main outcome, several examples are provided to demonstrate both the applicability of the developed model and its potential in optimizing energy consumption, achieving energy savings of up to 46% compared to the actual baseline control strategy, and external boundary conditions, identifying an optimal trade-off between energy saving and operation feasibility.
Open AccessPhysical Model for the Simulation of an Air Handling Unit Employed in an Automotive Production Process: Calibration Procedure and Potential Energy Saving
A meticulous thermo-hygrometric control is essential for various industrial production processes, particularly those involving the painting phases of body-in-white, in which the air temperature and relative humidity in production boots must be limited in strict intervals to ensure the high quality of the final product. However, traditional proportional integrative derivative (PID) controllers may result in non-optimal control strategies, leading to energy wastage due to response delays and unnecessary superheatings. In this regard, predictive models designed for control can significantly aid in achieving all the targets set by the European Union. This paper focuses on the development of a predictive model for the energy consumption of an air handling unit (AHU) used in the paint-shop area of an automotive production process. The model, developed in MATLAB 2024b, is based on mass and energy balances within each component, and phenomenological equations for heat exchangers. It enables the evaluation of thermal powers and water mass flow rates required to process an inlet air flow rate to achieve a target condition for the temperature and relative humidity. The model was calibrated and validated using experimental data of a real case study of an automotive production process, obtaining mean errors of 16% and 31% for the hot and cold heat exchangers, respectively, in predicting the water mass flow rate. Additionally, a control logic based on six regulation thermo-hygrometric zones was developed, which depended on the external conditions of temperature and relative humidity. Finally, as the main outcome, several examples are provided to demonstrate both the applicability of the developed model and its potential in optimizing energy consumption, achieving energy savings of up to 46% compared to the actual baseline control strategy, and external boundary conditions, identifying an optimal trade-off between energy saving and operation feasibility.
- Open Access
- 7 May 2024
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 523, 03006
EPBD 2023, F-GAS 2024, Eco-design and safety standards: Which design margins to be compliant with? An assessment of heat pumps for cooling
To decarbonize Europe achieving almost zero emissions in 2050, more stringent regulations are going to be applied. Particularly, Europe is investing in the emissions’ re-duction of buildings (existing and new ones), and strong improvements in energy performance of building are expected according to novel energy performance of building directive (at last phase of negotiation). At the same time, the production and use of fluorinated gases will be further reduced with the novel F-Gas regulation (under Parliament approval). New F-Gas will affect remarkably the small size, air-to-air split systems for air-conditioning, since no fluorinated gases will be used after 2035, forcing manufacturers to the use of natural refrigerants. Being propane the most efficient among the non-toxic natural refrigerants, less refrigerant would be charged into systems according to current safety standards: this would potentially reduce the heat transfer surfaces and, consequently, for the same capacity, the energy efficiency or, for the same efficiency, the capacity would decrease. In this paper, some scenario analyses, complying with actual and future plausible dispositions, are presented, in order to showing the margins for de-sign and commenting criticalities. In particular, the optimal design options are proposed for different fluids, in terms of costs vs energy performance, under representative cases, in terms of weather conditions and building types in Italy (existing ones and new ones respecting high-efficiency standards, trying to meet the requirements of hypothesized national law following the draft of the novel EPBD).
- 7 May 2024
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 523, 03006
Open AccessEPBD 2023, F-GAS 2024, Eco-design and safety standards: Which design margins to be compliant with? An assessment of heat pumps for cooling
To decarbonize Europe achieving almost zero emissions in 2050, more stringent regulations are going to be applied. Particularly, Europe is investing in the emissions’ re-duction of buildings (existing and new ones), and strong improvements in energy performance of building are expected according to novel energy performance of building directive (at last phase of negotiation). At the same time, the production and use of fluorinated gases will be further reduced with the novel F-Gas regulation (under Parliament approval). New F-Gas will affect remarkably the small size, air-to-air split systems for air-conditioning, since no fluorinated gases will be used after 2035, forcing manufacturers to the use of natural refrigerants. Being propane the most efficient among the non-toxic natural refrigerants, less refrigerant would be charged into systems according to current safety standards: this would potentially reduce the heat transfer surfaces and, consequently, for the same capacity, the energy efficiency or, for the same efficiency, the capacity would decrease. In this paper, some scenario analyses, complying with actual and future plausible dispositions, are presented, in order to showing the margins for de-sign and commenting criticalities. In particular, the optimal design options are proposed for different fluids, in terms of costs vs energy performance, under representative cases, in terms of weather conditions and building types in Italy (existing ones and new ones respecting high-efficiency standards, trying to meet the requirements of hypothesized national law following the draft of the novel EPBD).
- Open Access
- 1 December 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2648 (1) , 012093
Ammonia heat pumps for district heating: thermo-economic optimization analysis based on evaporator geometry for either direct expansion or chilled water configurations
Electric heat pumps are recognized as a key technology for decarbonization and have received increasing policy support in several countries over the last few years. These devices offer a highly efficient form of electric heating and could make an important contribution to the transition to a low carbon future, especially in case of district heating systems. Within this context, this paper presents a thermo-economic optimization analysis of a 7.35 MW electric heat pump system employed for district heating purposes and using ammonia as working fluid. The implemented code gathers multiple sub-models calibrated ad-hoc from real data or manufacturers’ datasheets. The heat exchangers are simulated by considering phenomenological equations and well-known heat transfer coefficient and pressure drop prediction methods. The optimization analysis is performed at constant condensation temperature that guarantees in/out hot water temperatures of 30/62 °C and is focused on the matching between compressor and evaporator heat exchanger, by considering either a direct expansion system or a chilled water heat pump. Both the coefficient of performance (COP) and the set-up costs are considered as optimization performance indicators for the construction of the Pareto front.
- 1 December 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2648 (1) , 012093
Open AccessAmmonia heat pumps for district heating: thermo-economic optimization analysis based on evaporator geometry for either direct expansion or chilled water configurations
Electric heat pumps are recognized as a key technology for decarbonization and have received increasing policy support in several countries over the last few years. These devices offer a highly efficient form of electric heating and could make an important contribution to the transition to a low carbon future, especially in case of district heating systems. Within this context, this paper presents a thermo-economic optimization analysis of a 7.35 MW electric heat pump system employed for district heating purposes and using ammonia as working fluid. The implemented code gathers multiple sub-models calibrated ad-hoc from real data or manufacturers’ datasheets. The heat exchangers are simulated by considering phenomenological equations and well-known heat transfer coefficient and pressure drop prediction methods. The optimization analysis is performed at constant condensation temperature that guarantees in/out hot water temperatures of 30/62 °C and is focused on the matching between compressor and evaporator heat exchanger, by considering either a direct expansion system or a chilled water heat pump. Both the coefficient of performance (COP) and the set-up costs are considered as optimization performance indicators for the construction of the Pareto front.
- Open Access
- 1 December 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2648 (1) , 012011
Assessment of the energy consumption of indoor farming for different climates and lighting system intensity
Nowadays, due to the energy, water, and arable land crises, as well as the constant global population growth and urbanization, water, energy, and food sources are strongly linked to each other, and a comprehensive analysis including all the influencing factors has to be carried out. In this context, the need to improve the energy performance of traditional cultivation systems, as well as to develop alternative and innovative ones, is causing a shift in interest from greenhouses to indoor farming methods (such as vertical farms) in the agricultural sector. In fact, they allow for completely controlled crop production without the use of chemical pesticides. Moreover, their productivity is independent of external conditions and improved compared to traditional systems. However, their energy consumption is larger than that of greenhouses. To evaluate the techno-economic feasibility of such systems, a comprehensive model of a vertical farm, including air conditioning, lighting systems, and plant evapotranspiration, has been developed to quantify the energy share for the different elements of the system (air conditioning and lighting) and to relate the energy consumption to the kilogram of produced crop, analysing exclusively the growth phase. The analysis is carried out for different cities and considers different scenarios in terms of lighting and electricity costs.
- 1 December 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2648 (1) , 012011
Open AccessAssessment of the energy consumption of indoor farming for different climates and lighting system intensity
Nowadays, due to the energy, water, and arable land crises, as well as the constant global population growth and urbanization, water, energy, and food sources are strongly linked to each other, and a comprehensive analysis including all the influencing factors has to be carried out. In this context, the need to improve the energy performance of traditional cultivation systems, as well as to develop alternative and innovative ones, is causing a shift in interest from greenhouses to indoor farming methods (such as vertical farms) in the agricultural sector. In fact, they allow for completely controlled crop production without the use of chemical pesticides. Moreover, their productivity is independent of external conditions and improved compared to traditional systems. However, their energy consumption is larger than that of greenhouses. To evaluate the techno-economic feasibility of such systems, a comprehensive model of a vertical farm, including air conditioning, lighting systems, and plant evapotranspiration, has been developed to quantify the energy share for the different elements of the system (air conditioning and lighting) and to relate the energy consumption to the kilogram of produced crop, analysing exclusively the growth phase. The analysis is carried out for different cities and considers different scenarios in terms of lighting and electricity costs.
- Open Access
Comparison between Physics-Based Approaches and Neural Networks for the Energy Consumption Optimization of an Automotive Production Industrial Process
The automotive production sector plays a significant role in the energy consumption of all the industrial sphere, which currently represents approximately 38% of the total global energy use. Especially in production sites with several manufacturing lines working in parallel, the occurrence of failures and anomalies or sudden changes in the production volume may require a re-scheduling of the entire production process. In this regard, a digital twin of each phase of the process would give several indications about the new re-scheduled manufacture in terms of energy consumption and the control strategy to adopt. Therefore, the main goal of this paper is to propose different modeling approaches to a degreasing tank process, which is a preliminary phase at automotive production sites before the application of paint to car bodies. In detail, two different approaches have been developed: the first is a physics-based thermodynamic approach, which relies on the mass and energy balances of the system analyzed, and the second is machine learning-based, with the calibration of several artificial neural networks (ANNs). All the investigated approaches were assessed and compared, and it was determined that, for this application and with the data at our disposal, the thermodynamic approach has better prediction accuracy, with an overall mean absolute error (MAE) of 1.30 °C. Moreover, the model can be used to optimize the heat source policy of the tank, for which it has demonstrated, with historical data, an energy saving potentiality of up to 30%, and to simulate future scenarios in which, due to company constraints, a re-scheduling of the production of more work shifts is required.
Open AccessComparison between Physics-Based Approaches and Neural Networks for the Energy Consumption Optimization of an Automotive Production Industrial Process
The automotive production sector plays a significant role in the energy consumption of all the industrial sphere, which currently represents approximately 38% of the total global energy use. Especially in production sites with several manufacturing lines working in parallel, the occurrence of failures and anomalies or sudden changes in the production volume may require a re-scheduling of the entire production process. In this regard, a digital twin of each phase of the process would give several indications about the new re-scheduled manufacture in terms of energy consumption and the control strategy to adopt. Therefore, the main goal of this paper is to propose different modeling approaches to a degreasing tank process, which is a preliminary phase at automotive production sites before the application of paint to car bodies. In detail, two different approaches have been developed: the first is a physics-based thermodynamic approach, which relies on the mass and energy balances of the system analyzed, and the second is machine learning-based, with the calibration of several artificial neural networks (ANNs). All the investigated approaches were assessed and compared, and it was determined that, for this application and with the data at our disposal, the thermodynamic approach has better prediction accuracy, with an overall mean absolute error (MAE) of 1.30 °C. Moreover, the model can be used to optimize the heat source policy of the tank, for which it has demonstrated, with historical data, an energy saving potentiality of up to 30%, and to simulate future scenarios in which, due to company constraints, a re-scheduling of the production of more work shifts is required.