Peter W. Nolte
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Peter W. Nolte has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Nils J. Ziegeler
Faculty of Electrical Engineering, South Westphalia University of Applied Sciences, 59494 Soest, Germany
5 shared publications - Stefan Schweizer
Faculty of Electrical Engineering, South Westphalia University of Applied Sciences, Lübecker Ring 2, 59494 Soest, Germany
5 shared publications S. Schweizer
3 shared publicationsF. Wagner
Department of Electrical Engineering, South Westphalia University of Applied Sciences, Soest, Germany
2 shared publicationsT. Malvisalo
2 shared publicationsA. Charlotte Rimbach
Faculty of Electrical Engineering, South Westphalia University of Applied Sciences, Soest, Germany
1 shared publication
Latest Publications
- Open Access
- 29 August 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (17) , 7635
Super-Frequency Sampling for Thermal Transient Analysis
Thermal transients of small or thermally well-conducting components typically relax with a very short time constant. In some cases, the fastest changes occur on a time scale of a few tens to hundreds of microseconds. Providing a sampling rate higher than 1 kHz is challenging, even for modern infrared cameras. This work presents a periodic non-uniform sampling technique for measuring thermographic transients, which increases the effective sampling rate by one order of magnitude to 10 kHz, resulting in a temporal resolution of 100 μs. The practical application of this technique captures parts of the thermal transient that would otherwise be missed for standard sampling rates. The results confirm the algorithm’s ability to enhance the effective sampling rate, providing a more detailed thermal analysis of rapid transient processes in small-scale electronic components.
- 29 August 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (17) , 7635
Open AccessSuper-Frequency Sampling for Thermal Transient Analysis
Thermal transients of small or thermally well-conducting components typically relax with a very short time constant. In some cases, the fastest changes occur on a time scale of a few tens to hundreds of microseconds. Providing a sampling rate higher than 1 kHz is challenging, even for modern infrared cameras. This work presents a periodic non-uniform sampling technique for measuring thermographic transients, which increases the effective sampling rate by one order of magnitude to 10 kHz, resulting in a temporal resolution of 100 μs. The practical application of this technique captures parts of the thermal transient that would otherwise be missed for standard sampling rates. The results confirm the algorithm’s ability to enhance the effective sampling rate, providing a more detailed thermal analysis of rapid transient processes in small-scale electronic components.
- Open Access
- 13 March 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (6) , 2940
Design and Construction of an LED-Based Excitation Source for Lock-In Thermography
Active thermography is an established technique for non-destructive testing and defect localisation. For external excitation, powerful light sources are commonly used. In addition to a high optical output, a good signal shape and response characteristic as well as control ports, which allow for multiple operation modes, are important for active thermography applications. In this work, the schematics for an excitation source based on infrared LEDs is presented. It features multiple control modes for easy integration into existing measurement setups as well as sophisticated control electronics to realize a wide range of excitation patterns. The phase and amplitude stability of this prototype is investigated and compared to the performance of a modulated halogen lamp as well as a halogen lamp and mechanical chopper combination.
- 13 March 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (6) , 2940
Open AccessDesign and Construction of an LED-Based Excitation Source for Lock-In Thermography
Active thermography is an established technique for non-destructive testing and defect localisation. For external excitation, powerful light sources are commonly used. In addition to a high optical output, a good signal shape and response characteristic as well as control ports, which allow for multiple operation modes, are important for active thermography applications. In this work, the schematics for an excitation source based on infrared LEDs is presented. It features multiple control modes for easy integration into existing measurement setups as well as sophisticated control electronics to realize a wide range of excitation patterns. The phase and amplitude stability of this prototype is investigated and compared to the performance of a modulated halogen lamp as well as a halogen lamp and mechanical chopper combination.
- 7 February 2022
- Published by Taylor & Francis in Quantitative InfraRed Thermography Journal
- Vol. 20 (3) , 93-105
Thermographic network identification for transient thermal heat path analysis
In this work, an evaluation method for transient thermal measurements is presented. It allows for a high temporal sensitivity by analysing the spectral composition of a thermal transient, the so-called time constant spectrum. The spectral components provide a detailed insight into the heat flow dynamics and thermal parameters describing a multi-layer system. The method is based on a one-dimensional heat path analysis technique common for the thermal characterisation of electronic components, called ‘network identification by deconvolution’. Here, a generalisation, called ‘thermographic network identification’, is presented to obtain spatially resolved thermal equivalence networks as complete thermal model of the device under study. As a proof of concept, two samples are investigated. The method is discussed on the basis of the obtained results.
- 7 February 2022
- Published by Taylor & Francis in Quantitative InfraRed Thermography Journal
- Vol. 20 (3) , 93-105
Thermographic network identification for transient thermal heat path analysis
In this work, an evaluation method for transient thermal measurements is presented. It allows for a high temporal sensitivity by analysing the spectral composition of a thermal transient, the so-called time constant spectrum. The spectral components provide a detailed insight into the heat flow dynamics and thermal parameters describing a multi-layer system. The method is based on a one-dimensional heat path analysis technique common for the thermal characterisation of electronic components, called ‘network identification by deconvolution’. Here, a generalisation, called ‘thermographic network identification’, is presented to obtain spatially resolved thermal equivalence networks as complete thermal model of the device under study. As a proof of concept, two samples are investigated. The method is discussed on the basis of the obtained results.
- Open Access
Optimization-Based Network Identification for Thermal Transient Measurements
Network identification by deconvolution is a proven method for determining the thermal structure function of a given device. The method allows to derive the thermal capacitances as well as the resistances of a one-dimensional thermal path from the thermal step response of the device. However, the results of this method are significantly affected by noise in the measured data, which is unavoidable to a certain extent. In this paper, a post-processing procedure for network identification from thermal transient measurements is presented. This so-called optimization-based network identification provides a much more accurate and robust result compared to approaches using Fourier or Bayesian deconvolution in combination with Foster-to-Cauer transformation. The thermal structure function obtained from network identification by deconvolution is improved by repeatedly solving the inverse problem in a multi-dimensional optimization process. The result is a non-diverging thermal structure function, which agrees well with the measured thermal impedance. In addition, the associated time constant spectrum can be calculated very accurately. This work shows the potential of inverse optimization approaches for network identification.
Open AccessOptimization-Based Network Identification for Thermal Transient Measurements
Network identification by deconvolution is a proven method for determining the thermal structure function of a given device. The method allows to derive the thermal capacitances as well as the resistances of a one-dimensional thermal path from the thermal step response of the device. However, the results of this method are significantly affected by noise in the measured data, which is unavoidable to a certain extent. In this paper, a post-processing procedure for network identification from thermal transient measurements is presented. This so-called optimization-based network identification provides a much more accurate and robust result compared to approaches using Fourier or Bayesian deconvolution in combination with Foster-to-Cauer transformation. The thermal structure function obtained from network identification by deconvolution is improved by repeatedly solving the inverse problem in a multi-dimensional optimization process. The result is a non-diverging thermal structure function, which agrees well with the measured thermal impedance. In addition, the associated time constant spectrum can be calculated very accurately. This work shows the potential of inverse optimization approaches for network identification.
- Open Access
Quantitative Performance Comparison of Thermal Structure Function Computations
The determination of thermal structure functions from transient thermal measurements using network identification by deconvolution is a delicate process as it is sensitive to noise in the measured data. Great care must be taken not only during the measurement process but also to ensure a stable implementation of the algorithm. In this paper, a method is presented that quantifies the absolute accuracy of network identification on the basis of different test structures. For this purpose, three measures of accuracy are defined. By these metrics, several variants of network identification are optimized and compared against each other. Performance in the presence of noise is analyzed by adding Gaussian noise to the input data. In the cases tested, the use of a Bayesian deconvolution provided the best results.
Open AccessQuantitative Performance Comparison of Thermal Structure Function Computations
The determination of thermal structure functions from transient thermal measurements using network identification by deconvolution is a delicate process as it is sensitive to noise in the measured data. Great care must be taken not only during the measurement process but also to ensure a stable implementation of the algorithm. In this paper, a method is presented that quantifies the absolute accuracy of network identification on the basis of different test structures. For this purpose, three measures of accuracy are defined. By these metrics, several variants of network identification are optimized and compared against each other. Performance in the presence of noise is analyzed by adding Gaussian noise to the input data. In the cases tested, the use of a Bayesian deconvolution provided the best results.
- Open Access
- 14 October 2019
- Published by Taylor & Francis in Quantitative InfraRed Thermography Journal
- Vol. 17 (2) , 96-106
Suitability of lock-in infrared thermography for luminescent glass development
The purpose of this work is to evaluate the suitability of lock-in infrared thermography for luminescent glass development. Lithium borate glass of different composition is fabricated and studied to detect changes in the thermal diffusivity as the composition changes and property modifiers are introduced. In addition, the effect of terbium doping on the thermal diffusivity of the glass is studied.
- 14 October 2019
- Published by Taylor & Francis in Quantitative InfraRed Thermography Journal
- Vol. 17 (2) , 96-106
Open AccessSuitability of lock-in infrared thermography for luminescent glass development
The purpose of this work is to evaluate the suitability of lock-in infrared thermography for luminescent glass development. Lithium borate glass of different composition is fabricated and studied to detect changes in the thermal diffusivity as the composition changes and property modifiers are introduced. In addition, the effect of terbium doping on the thermal diffusivity of the glass is studied.
- Open Access
Characterization of Luminescent Materials with 151Eu Mössbauer Spectroscopy
The application of Mössbauer spectroscopy to luminescent materials is described. Many solids doped with europium are luminescent, i.e., when irradiated with light they emit light of a longer wavelength. These materials therefore have practical applications in tuning the light output of devices like light emitting diodes. The optical properties are very different for the two possible valence states Eu and Eu , the former producing ultraviolet/visible light that shifts from violet to red depending on the host and the latter red light, so it is important to have a knowledge of their behavior in a sample environment. Photoluminescence spectra cannot give a quantitative analysis of Eu and Eu ions. Mössbauer spectroscopy, however, is more powerful and gives a separate spectrum for each oxidation state enabling the relative amount present to be estimated. The oxidation state can be identified from its isomer shift which is between and mm/s for Eu compared to around 0 mm/s for Eu . Furthermore, within each oxidation state, there are changes depending on the ligands attached to the europium: the shift is more positive for increased covalency of the bonding ligand X, or Eu concentration, and decreases for increasing Eu–X bond length.Open AccessCharacterization of Luminescent Materials with 151Eu Mössbauer Spectroscopy
The application of Mössbauer spectroscopy to luminescent materials is described. Many solids doped with europium are luminescent, i.e., when irradiated with light they emit light of a longer wavelength. These materials therefore have practical applications in tuning the light output of devices like light emitting diodes. The optical properties are very different for the two possible valence states Eu and Eu , the former producing ultraviolet/visible light that shifts from violet to red depending on the host and the latter red light, so it is important to have a knowledge of their behavior in a sample environment. Photoluminescence spectra cannot give a quantitative analysis of Eu and Eu ions. Mössbauer spectroscopy, however, is more powerful and gives a separate spectrum for each oxidation state enabling the relative amount present to be estimated. The oxidation state can be identified from its isomer shift which is between and mm/s for Eu compared to around 0 mm/s for Eu . Furthermore, within each oxidation state, there are changes depending on the ligands attached to the europium: the shift is more positive for increased covalency of the bonding ligand X, or Eu concentration, and decreases for increasing Eu–X bond length. - 1 January 2018
- Published by QIRT Council
Suitability of Lock-in Infrared Thermography for Luminescent Glass Development
- 1 January 2018
- Published by QIRT Council
Suitability of Lock-in Infrared Thermography for Luminescent Glass Development
- 8 May 2017
- Published by Taylor & Francis in Quantitative InfraRed Thermography Journal
- Vol. 14 (2) , 218-225
Thermal diffusivity of metals determined by lock-in thermography
Lock-in infrared thermography is a well-established technique for measuring the thermal diffusivity of materials. A commonly-used method is to analyse the spread of a thermal wave along the surface of a thin sample or a filament, known as the slope method. In this work, an alternative technique is proposed, in which the phase delay of the thermal wave passing through sheets made of different metals is analysed using periodical laser heating. Different lock-in frequencies are used to obtain the frequency-dependent phase behaviour of thermal waves generated by the laser pulses. A subsequent curve fitting provides the coefficients required to determine the thermal diffusivity. To achieve a comparison with ambient conditions, the measurements are also performed in vacuum. A comparison with literature data substantiates that the proposed method is a robust approach for the determination of the thermal diffusivity in applications where the sample thickness exceeds the limits of the slope method.
- 8 May 2017
- Published by Taylor & Francis in Quantitative InfraRed Thermography Journal
- Vol. 14 (2) , 218-225
Thermal diffusivity of metals determined by lock-in thermography
Lock-in infrared thermography is a well-established technique for measuring the thermal diffusivity of materials. A commonly-used method is to analyse the spread of a thermal wave along the surface of a thin sample or a filament, known as the slope method. In this work, an alternative technique is proposed, in which the phase delay of the thermal wave passing through sheets made of different metals is analysed using periodical laser heating. Different lock-in frequencies are used to obtain the frequency-dependent phase behaviour of thermal waves generated by the laser pulses. A subsequent curve fitting provides the coefficients required to determine the thermal diffusivity. To achieve a comparison with ambient conditions, the measurements are also performed in vacuum. A comparison with literature data substantiates that the proposed method is a robust approach for the determination of the thermal diffusivity in applications where the sample thickness exceeds the limits of the slope method.
- Open Access
- 1 January 2016
- Published by QIRT Council
Analysis of Thermal Diffusivity of Metals using Lock-in Thermography
- 1 January 2016
- Published by QIRT Council
Open AccessAnalysis of Thermal Diffusivity of Metals using Lock-in Thermography