Craig Priest
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Craig Priest has a total of 267 co-authors. Here are the top co-authors by number of shared publications:
- John Ralston
Future Industries Institute, University of South Australia, Mawson Lakes, SA 5095, Australia
26 shared publications - Rossen Sedev
Future Industries Institute, University of South Australia, Mawson Lakes, SA 5095, Australia
20 shared publications - Nicolas Hans Voelcker
Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Australia
11 shared publications Frederik H. Kriel
Future Industries Institute, University of South Australia, Mawson Lakes, Australia
8 shared publications- Bin Guan
Future Industries Institute, STEM, University of South Australia, Mawson Lakes, SA 5095, Australia
6 shared publications - Nicolas Riesen
ARC Research Hub for Integrated Devices for End-user Analysis at Low-Levels (IDEAL), Future Industries Institute, STEM, University of South Australia, Mawson Lakes, SA 5095, Australia
6 shared publications
Latest Publications
- 26 May 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (26) , 38678-38688
Integration of 3D-Printed Micro/Nanostructures with Interdigitated Electrodes for Low-Matrix-Effect Sensing
Electrochemical sensors offer the advantages of low cost, high sensitivity, and miniaturization for a wide range of biological applications, including in situ detection of cell metabolites and monitoring cell behavior in real time. However, the complex matrix in biosystems often leads to electrode fouling and inferior sensing performance. In addition to chemical barriers featuring assorted antifouling molecules or coatings, creating micro/nano hierarchical structures on top of electrodes can provide physical barriers to mitigate matrix interference without affecting electron transfer. The emerging two-photon polymerization (TPP) 3D printing technique with the capability to produce precise submicron to several micrometer features on a variety of substrates has enabled the straightforward fabrication of complex hierarchical structures. In this paper, we integrate the value-added micro/nanostructures made by TPP printing with the interdigitated electrode-based sensors and demonstrate the platform's advantages in filtering out small interfering micro-objects and thus reducing matrix effects. Applying the novel approach to real-time cell monitoring, a 3D-printed microstructure-integrated platform shows higher sensitivity (i.e., the slope of the calibration curve) to model redox analytes in cell culture medium compared to bare electrodes, which display compromised sensitivity due to cell passivation. This research opens a new avenue for mitigating matrix interference and enhancing electrochemical sensing with significant implications across a broad range of applications.
- 26 May 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (26) , 38678-38688
Integration of 3D-Printed Micro/Nanostructures with Interdigitated Electrodes for Low-Matrix-Effect Sensing
Electrochemical sensors offer the advantages of low cost, high sensitivity, and miniaturization for a wide range of biological applications, including in situ detection of cell metabolites and monitoring cell behavior in real time. However, the complex matrix in biosystems often leads to electrode fouling and inferior sensing performance. In addition to chemical barriers featuring assorted antifouling molecules or coatings, creating micro/nano hierarchical structures on top of electrodes can provide physical barriers to mitigate matrix interference without affecting electron transfer. The emerging two-photon polymerization (TPP) 3D printing technique with the capability to produce precise submicron to several micrometer features on a variety of substrates has enabled the straightforward fabrication of complex hierarchical structures. In this paper, we integrate the value-added micro/nanostructures made by TPP printing with the interdigitated electrode-based sensors and demonstrate the platform's advantages in filtering out small interfering micro-objects and thus reducing matrix effects. Applying the novel approach to real-time cell monitoring, a 3D-printed microstructure-integrated platform shows higher sensitivity (i.e., the slope of the calibration curve) to model redox analytes in cell culture medium compared to bare electrodes, which display compromised sensitivity due to cell passivation. This research opens a new avenue for mitigating matrix interference and enhancing electrochemical sensing with significant implications across a broad range of applications.
- Open Access
- 1 January 2025
- Published by AIP Publishing in APL Materials
- Vol. 13 (1)
Robust and consistent bonding of polydimethylsiloxane to polystyrene cell culture plates
Polydimethylsiloxane (PDMS) is a commonly used material for the design of new cell culture devices. Typically, molded PDMS is bonded to glass or another PDMS layer; however, it is challenging to form high-strength bonds with polymers commonly used for cell culture-ware, such as polystyrene (PS). Therefore, a robust PDMS–PS bonding method would facilitate a wider use of PDMS in tissue culture applications. Herein, we develop an irreversible, stable, and consistent PDMS–PS bonding protocol. We show that this method is superior to other currently available methods because of its bonding strength, reusability, and reliability. Furthermore, we demonstrate the utility of this bonding process in fabricating our Heart-Dyno device, a 96-well-based platform for culturing cardiac organoids. This bonding process has been successfully used over the past 2 years, with hundreds of plates manufactured for drug screening applications. Others may also have similar applications where this method may facilitate the fabrication of more robust PDMS–PS devices.
- 1 January 2025
- Published by AIP Publishing in APL Materials
- Vol. 13 (1)
Open AccessRobust and consistent bonding of polydimethylsiloxane to polystyrene cell culture plates
Polydimethylsiloxane (PDMS) is a commonly used material for the design of new cell culture devices. Typically, molded PDMS is bonded to glass or another PDMS layer; however, it is challenging to form high-strength bonds with polymers commonly used for cell culture-ware, such as polystyrene (PS). Therefore, a robust PDMS–PS bonding method would facilitate a wider use of PDMS in tissue culture applications. Herein, we develop an irreversible, stable, and consistent PDMS–PS bonding protocol. We show that this method is superior to other currently available methods because of its bonding strength, reusability, and reliability. Furthermore, we demonstrate the utility of this bonding process in fabricating our Heart-Dyno device, a 96-well-based platform for culturing cardiac organoids. This bonding process has been successfully used over the past 2 years, with hundreds of plates manufactured for drug screening applications. Others may also have similar applications where this method may facilitate the fabrication of more robust PDMS–PS devices.
- Open Access
- 9 September 2024
- Published by Frontiers Media SA in Frontiers in Chemical Engineering
- Vol. 6, 1445900
Industry relevant microfluidic platforms for mineral leaching experiments
Microfluidic and lab-on-a-chip devices offer exquisite temporal and spatial control over chemical and physical processes that are important in mineral exploration and mining. These include mineral-water interfacial reactions, dissolution, and adsorption/desorption in pores, fractures, or other micro/nanostructures. Microfluidic mineral studies offer advantages of small sample and reagent volumes, high throughout, and short analytical cycles that may enable in-field mining decisions. However, not many microfluidic studies have targeted these mining sector challenges for mineral leaching. In this review, special attention is given to microscale experimental platforms for predicting extraction and leaching of industrially-relevant samples (real ore samples). Advantages and challenges of these platforms are given. The review concludes that there are significant opportunities for microfluidics in mineral analysis, screening, process intensification, and process control in the resource and minerals sector.
- 9 September 2024
- Published by Frontiers Media SA in Frontiers in Chemical Engineering
- Vol. 6, 1445900
Open AccessIndustry relevant microfluidic platforms for mineral leaching experiments
Microfluidic and lab-on-a-chip devices offer exquisite temporal and spatial control over chemical and physical processes that are important in mineral exploration and mining. These include mineral-water interfacial reactions, dissolution, and adsorption/desorption in pores, fractures, or other micro/nanostructures. Microfluidic mineral studies offer advantages of small sample and reagent volumes, high throughout, and short analytical cycles that may enable in-field mining decisions. However, not many microfluidic studies have targeted these mining sector challenges for mineral leaching. In this review, special attention is given to microscale experimental platforms for predicting extraction and leaching of industrially-relevant samples (real ore samples). Advantages and challenges of these platforms are given. The review concludes that there are significant opportunities for microfluidics in mineral analysis, screening, process intensification, and process control in the resource and minerals sector.
- Open Access
- 14 August 2024
- Published by Wiley in Chemical Engineering & Technology
- Vol. 47 (10)
Eco‐Friendly Synthesis of Porous Molybdenum Carbide Nanomaterials for Advanced Electrochemical Sensing Applications
A highly stable and electrochemically active porous molybdenum carbide (PMC) has been synthesized from agricultural waste by carburization of bagasse under inert conditions. The surface area and porous structure of the resulting PMCs can be tuned by varying the synthesis conditions. The PMCs obtained have been characterized via XRD, XPS, SEM, and gas physisorption techniques. The final PMC materials are highly crystalline with nanoscale porosity and with an active surface area of up to 717 m2.g−1. This work unlocks a promising avenue for developing highly active electrochemical nanomaterials using green synthesis, potentially eliminating the need for noble metals. The results demonstrate a six‐fold increase in the electrochemical signal.
- 14 August 2024
- Published by Wiley in Chemical Engineering & Technology
- Vol. 47 (10)
Open AccessEco‐Friendly Synthesis of Porous Molybdenum Carbide Nanomaterials for Advanced Electrochemical Sensing Applications
A highly stable and electrochemically active porous molybdenum carbide (PMC) has been synthesized from agricultural waste by carburization of bagasse under inert conditions. The surface area and porous structure of the resulting PMCs can be tuned by varying the synthesis conditions. The PMCs obtained have been characterized via XRD, XPS, SEM, and gas physisorption techniques. The final PMC materials are highly crystalline with nanoscale porosity and with an active surface area of up to 717 m2.g−1. This work unlocks a promising avenue for developing highly active electrochemical nanomaterials using green synthesis, potentially eliminating the need for noble metals. The results demonstrate a six‐fold increase in the electrochemical signal.
- 21 February 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (9) , 12042-12051
Microsphere-Enabled Micropillar Array for Whispering Gallery Mode Virus Detection
Rapid detection of pathogens and analytes at the point of care offers an opportunity for prompt patient management and public health control. This paper reports an open microfluidic platform coupled with active whispering gallery mode (WGM) microsphere resonators for the rapid detection of influenza viruses. The WGM microsphere resonators, precoated with influenza A polyclonal antibodies, are mechanically trapped in the open micropillar array, where the evaporation-driven flow continuously transports a small volume (∼μL) of sample to the resonators without auxiliaries. Selective chemical modification of the pillar array changes surface wettability and flow pattern, which enhances the detection sensitivity of the WGM resonator-based virus sensor. The optofluidic sensing platform is able to specifically detect influenza A viruses within 15 min using a few microliters of sample and displays a linear response to different virus concentrations.
- 21 February 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (9) , 12042-12051
Microsphere-Enabled Micropillar Array for Whispering Gallery Mode Virus Detection
Rapid detection of pathogens and analytes at the point of care offers an opportunity for prompt patient management and public health control. This paper reports an open microfluidic platform coupled with active whispering gallery mode (WGM) microsphere resonators for the rapid detection of influenza viruses. The WGM microsphere resonators, precoated with influenza A polyclonal antibodies, are mechanically trapped in the open micropillar array, where the evaporation-driven flow continuously transports a small volume (∼μL) of sample to the resonators without auxiliaries. Selective chemical modification of the pillar array changes surface wettability and flow pattern, which enhances the detection sensitivity of the WGM resonator-based virus sensor. The optofluidic sensing platform is able to specifically detect influenza A viruses within 15 min using a few microliters of sample and displays a linear response to different virus concentrations.
- Open Access
- 20 November 2023
- Published by Royal Society of Chemistry (RSC) in Materials Advances
- Vol. 5 (1) , 209-219
Enhancing the conductivity of plasma polymer functionalized electrodes using gold nanoparticles
Plasma deposited polyoxazoline thin films (POx) are a promising solution for the rapid, scalable, and substrate-independent immuno-functionalization of electrochemical biosensors.
- 20 November 2023
- Published by Royal Society of Chemistry (RSC) in Materials Advances
- Vol. 5 (1) , 209-219
Open AccessEnhancing the conductivity of plasma polymer functionalized electrodes using gold nanoparticles
Plasma deposited polyoxazoline thin films (POx) are a promising solution for the rapid, scalable, and substrate-independent immuno-functionalization of electrochemical biosensors.
- 29 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A Pump-Free Optofluidic Biosensing Platform Based on Whispering Gallery Mode Microspheres
Optofluidic biosensors offer significant advantages for lab-on-a-chip chemical and biological analysis by combining microfluidics for small-volume liquid manipulation with the high sensitivity and adaptability of optical sensing techniques. In this study, we present an optofluidic biosensing platform utilising a micropillar array coupled with active whispering gallery mode (WGM) microsphere resonators for the rapid detection of influenza viruses. The WGM microspheres are coated with polyclonal antibodies capable of targeting both intact virus and fragments of viral proteins. The micropillar array facilitates continuous sampling and measurement through evaporation-driven fluid transport.
- 29 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A Pump-Free Optofluidic Biosensing Platform Based on Whispering Gallery Mode Microspheres
Optofluidic biosensors offer significant advantages for lab-on-a-chip chemical and biological analysis by combining microfluidics for small-volume liquid manipulation with the high sensitivity and adaptability of optical sensing techniques. In this study, we present an optofluidic biosensing platform utilising a micropillar array coupled with active whispering gallery mode (WGM) microsphere resonators for the rapid detection of influenza viruses. The WGM microspheres are coated with polyclonal antibodies capable of targeting both intact virus and fragments of viral proteins. The micropillar array facilitates continuous sampling and measurement through evaporation-driven fluid transport.
- Open Access
- 25 April 2023
- Published by Wiley in Plasma Processes and Polymers
- Vol. 20 (8)
Electrochemical behavior of oxazoline‐based plasma polymers for biosensing applications
Plasma‐polymerized polyoxazoline (POx) thin films offer a fast, scalable, and solvent‐free method of electrode functionalization through the unique chemistry of the oxazoline ring. However, for POx to be a viable green alternative to existing surface modification approaches, the films should be able to withstand the processing steps involved in biosensing. Here, the effects that current exposure, extended incubation, and repeated electrode rinses have on the electrochemical and physical stability of polymethyloxazoline thin films are investigated. The films are observed to become more diffusive after incubation and rinse steps. While no significant changes in chemistry were observed, a marked change in nanotopography occurred after exposure to current, suggesting a change in the polymer film structure.
- 25 April 2023
- Published by Wiley in Plasma Processes and Polymers
- Vol. 20 (8)
Open AccessElectrochemical behavior of oxazoline‐based plasma polymers for biosensing applications
Plasma‐polymerized polyoxazoline (POx) thin films offer a fast, scalable, and solvent‐free method of electrode functionalization through the unique chemistry of the oxazoline ring. However, for POx to be a viable green alternative to existing surface modification approaches, the films should be able to withstand the processing steps involved in biosensing. Here, the effects that current exposure, extended incubation, and repeated electrode rinses have on the electrochemical and physical stability of polymethyloxazoline thin films are investigated. The films are observed to become more diffusive after incubation and rinse steps. While no significant changes in chemistry were observed, a marked change in nanotopography occurred after exposure to current, suggesting a change in the polymer film structure.
- 31 January 2023
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 15 (10) , 4863-4869
Ultra-high-resolution greyscale fluorescence images via UV-exposure of thin flexible phosphor films
Thin films of BaFCl:Sm nanocrystals prepared using a polymer binder were used to create fluorescence images. The phosphor films were exposed to a UV-C mercury lamp light source via chromium-coated quartz greyscale masks to create 4 μm resolution greyscale fluorescence images. The mechanism relies on the highly efficient conversion of Sm3+ to Sm2+ ions upon exposure to UV-C light which displays a large linear dynamic range. The red fluorescence around 688 nm of the Sm2+ is then read-out using blue-violet illumination under a laser scanning confocal microscope. The greyscale images with 16 greyscale levels had a resolution equivalent to ∼125 line pairs per mm or ∼6400 dpi. Improvements in the resolution would be possible using collimated UV-C laser exposure of the film or the use of higher resolution photomasks. Ultra-high resolution binary fluorescence images were also created with resolutions down to 2 μm (∼250 line pairs per mm, ∼12 700 dpi). Downstream applications of the technology could include tailored covert or overt anti-counterfeiting labelling.
- 31 January 2023
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 15 (10) , 4863-4869
Ultra-high-resolution greyscale fluorescence images via UV-exposure of thin flexible phosphor films
Thin films of BaFCl:Sm nanocrystals prepared using a polymer binder were used to create fluorescence images. The phosphor films were exposed to a UV-C mercury lamp light source via chromium-coated quartz greyscale masks to create 4 μm resolution greyscale fluorescence images. The mechanism relies on the highly efficient conversion of Sm3+ to Sm2+ ions upon exposure to UV-C light which displays a large linear dynamic range. The red fluorescence around 688 nm of the Sm2+ is then read-out using blue-violet illumination under a laser scanning confocal microscope. The greyscale images with 16 greyscale levels had a resolution equivalent to ∼125 line pairs per mm or ∼6400 dpi. Improvements in the resolution would be possible using collimated UV-C laser exposure of the film or the use of higher resolution photomasks. Ultra-high resolution binary fluorescence images were also created with resolutions down to 2 μm (∼250 line pairs per mm, ∼12 700 dpi). Downstream applications of the technology could include tailored covert or overt anti-counterfeiting labelling.
- Open Access
- 12 December 2022
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 12 (55) , 36150-36157
Reversible colorimetric sensing of volatile analytes by wicking in close proximity to a photonic film
Isolation of volatile analytes from fluid samples is a rate-determining step that can delay sensor response time. An optofluidic sensing platform capable of rapidly detecting gas-phase analytes from flowing micro-volume fluid samples is reported.
- 12 December 2022
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 12 (55) , 36150-36157
Open AccessReversible colorimetric sensing of volatile analytes by wicking in close proximity to a photonic film
Isolation of volatile analytes from fluid samples is a rate-determining step that can delay sensor response time. An optofluidic sensing platform capable of rapidly detecting gas-phase analytes from flowing micro-volume fluid samples is reported.