Cláudia Casaca
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Cláudia Casaca has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Mario Costa
IDMEC, Mechanical Engineering Department, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
7 shared publications - Gonçalo Duarte
Instituto Superior de Engenharia de Lisboa, Instituto Politécnico de Lisboa, Rua Conselheiro Emídio Navarro 1, 1959-007 Lisboa, Portugal
2 shared publications A. A. M. Oliveira
Mechanical Engineering Department, Federal University of Santa Catarina, 88040-900 Florianópolis, Santa Catarina, Brazil
1 shared publicationA. Moço
1 shared publication- Alda Carvalho
Grupo de Investigação em Modelação e Optimização de Sistemas Multifuncionais (GI-MOSM), Instituto Superior de Engenharia de Lisboa, CEMAPRE, ISEG, Universidade de Lisboa, 1200-781 Lisboa, Portugal
1 shared publication - Daniel C. Vaz
UNIDEMI, Department of Mechanical and Industrial Engineering, NOVA School of Science and Technology, Universidade NOVA de Lisboa, 1099-085 Lisbon, Portugal
1 shared publication
Latest Publications
- Open Access
Numerical Assessment of Energy Performance of an Existing Building Interacting with Electric Mobility: A Case Study in Lisbon, Portugal
In the context of the global transition toward sustainability and energy efficiency, the retrofitting of existing service buildings has become a strategic priority. With the increasing adoption of electric vehicles (EVs) and the need to reduce greenhouse gas emissions, adapting these buildings is essential to achieving low-carbon urban environments. This paper presents a numerical tool developed to simulate the energy performance of a service building and to evaluate the impact of multiple energy efficiency measures on energy consumption and CO2 emissions. The assessed measures include the installation of photovoltaic panels on roofs and facades, optimization of Heating, Ventilation, and Air Conditioning (HVAC) systems through temperature set-point adjustments, improvements to the building envelope and integration of electric mobility infrastructure. The analysis focuses on an existing building in Lisbon, Portugal, considering both individual and combined effects of these strategies. The results indicate that combined implementation of all measures, including EV integration, can reduce energy demand and CO2 emissions by up to approximately 50%. However, regulatory uncertainty regarding EV accounting remains a challenge, highlighting the need for clearer policies to support sustainable urban transformation.
Open AccessNumerical Assessment of Energy Performance of an Existing Building Interacting with Electric Mobility: A Case Study in Lisbon, Portugal
In the context of the global transition toward sustainability and energy efficiency, the retrofitting of existing service buildings has become a strategic priority. With the increasing adoption of electric vehicles (EVs) and the need to reduce greenhouse gas emissions, adapting these buildings is essential to achieving low-carbon urban environments. This paper presents a numerical tool developed to simulate the energy performance of a service building and to evaluate the impact of multiple energy efficiency measures on energy consumption and CO2 emissions. The assessed measures include the installation of photovoltaic panels on roofs and facades, optimization of Heating, Ventilation, and Air Conditioning (HVAC) systems through temperature set-point adjustments, improvements to the building envelope and integration of electric mobility infrastructure. The analysis focuses on an existing building in Lisbon, Portugal, considering both individual and combined effects of these strategies. The results indicate that combined implementation of all measures, including EV integration, can reduce energy demand and CO2 emissions by up to approximately 50%. However, regulatory uncertainty regarding EV accounting remains a challenge, highlighting the need for clearer policies to support sustainable urban transformation.
- Open Access
- 6 September 2024
- Published by MDPI AG in Clean Technologies
- Vol. 6 (3) , 1169-1180
Assessment of Influential Operational Parameters in the Mitigation of CO2 Emissions in a Power Plant: Case Study in Portugal
The European decarbonization goals and requirement for energy independence are mostly relying on intermittent renewable energy sources for electrification. A numerical model was developed to simulate the operation of a steam generator, allowing a study of the potential impacts of retrofitting existing coal-fired power plants to operate with biomass or coal–biomass mixtures on combustion parameters and CO2 emissions. The results obtained using the operational parameters of the Sines power plant indicate that a mixture of 25% coal and 75% pine sawdust allow operation at λ = 1.8, demonstrating that a small amount of coal allows operation near the coal combustion parameters (λ = 1.9). These conditions have the drawback of a reduction of 8.7% in adiabatic flame temperature but a significant reduction of 57.5% in CO2 emissions, considering the biomass as carbon-neutral.
- 6 September 2024
- Published by MDPI AG in Clean Technologies
- Vol. 6 (3) , 1169-1180
Open AccessAssessment of Influential Operational Parameters in the Mitigation of CO2 Emissions in a Power Plant: Case Study in Portugal
The European decarbonization goals and requirement for energy independence are mostly relying on intermittent renewable energy sources for electrification. A numerical model was developed to simulate the operation of a steam generator, allowing a study of the potential impacts of retrofitting existing coal-fired power plants to operate with biomass or coal–biomass mixtures on combustion parameters and CO2 emissions. The results obtained using the operational parameters of the Sines power plant indicate that a mixture of 25% coal and 75% pine sawdust allow operation at λ = 1.8, demonstrating that a small amount of coal allows operation near the coal combustion parameters (λ = 1.9). These conditions have the drawback of a reduction of 8.7% in adiabatic flame temperature but a significant reduction of 57.5% in CO2 emissions, considering the biomass as carbon-neutral.
- Open Access
- 5 May 2023
- Published by Universidad Politecnica de Cartagena
Ventilation and deodorization system optimization of a wastewater treatment plant
Quality of life is entirely linked to air quality around us, whether inside or outside a building. Therefore, it is not surprising that the owners and occupants of certain spaces pay attention to the air quality, especially when they work or are close to a wastewater treatment plant. The aims of this work are to diagnose the existing situation in ventilation and deodorization system of covered wastewater treatment plant and to suggest changes to improve indoor air quality and make the operation of this system more reliable and economical. The ventilation system, consisting of 10 air handling units, supply 230.000 m 3 /h, where some ventilation lines have 250 m. The system's optimization solution, as well as the two new centrifugal fans implementation, with speed variation, allow a reduction in the total fans power to 60 kW and increase the energy efficiency in 60 %.
- 5 May 2023
- Published by Universidad Politecnica de Cartagena
Open AccessVentilation and deodorization system optimization of a wastewater treatment plant
Quality of life is entirely linked to air quality around us, whether inside or outside a building. Therefore, it is not surprising that the owners and occupants of certain spaces pay attention to the air quality, especially when they work or are close to a wastewater treatment plant. The aims of this work are to diagnose the existing situation in ventilation and deodorization system of covered wastewater treatment plant and to suggest changes to improve indoor air quality and make the operation of this system more reliable and economical. The ventilation system, consisting of 10 air handling units, supply 230.000 m 3 /h, where some ventilation lines have 250 m. The system's optimization solution, as well as the two new centrifugal fans implementation, with speed variation, allow a reduction in the total fans power to 60 kW and increase the energy efficiency in 60 %.
- 29 November 2022
- Published by Springer Nature
- p. 309-324
A Methodology to Reveal Terrain Effects from Wind Farm SCADA Data Using a Wind Signature Concept
- 29 November 2022
- Published by Springer Nature
- p. 309-324
A Methodology to Reveal Terrain Effects from Wind Farm SCADA Data Using a Wind Signature Concept
- 2 June 2020
- Published by Knowledge E DMCC in KnE Engineering
- p. 585–598
Comparative Study on Coolbox/Waterloop and Natural Refrigerants Solutions for Commercial Refrigeration
This paper presents some natural and artificial solutions for reducing the use of HFCs in commercial refrigeration systems to limit greenhouse gas (GHG) emissions to the atmosphere. Additionally, the case study of a medium size supermarket is addressed. For this, a series of cooling systems have been sized which are divided into Coolbox/Waterloop systems and centralized systems. Three centralized systems with R410a, R717 and R744/R717 were dimensioned as well as a Coolbox/Waterloop system with R410a. This way is possible to ensure a comparison not only between fluids but also between the Coolbox/Waterloop technology and the centralized solution. After sizing the systems, the comparative energy, economic and carbon emission studies of the systems, in which their application has been found to be possible, are presented. After analysing the systems covered and the studies performed, it is concluded not only about the best applicable system, but also about the limitations found in each of the others. Keywords: Natural refrigerants, Commercial refrigeration, Coolbox, Waterloop
- 2 June 2020
- Published by Knowledge E DMCC in KnE Engineering
- p. 585–598
Comparative Study on Coolbox/Waterloop and Natural Refrigerants Solutions for Commercial Refrigeration
This paper presents some natural and artificial solutions for reducing the use of HFCs in commercial refrigeration systems to limit greenhouse gas (GHG) emissions to the atmosphere. Additionally, the case study of a medium size supermarket is addressed. For this, a series of cooling systems have been sized which are divided into Coolbox/Waterloop systems and centralized systems. Three centralized systems with R410a, R717 and R744/R717 were dimensioned as well as a Coolbox/Waterloop system with R410a. This way is possible to ensure a comparison not only between fluids but also between the Coolbox/Waterloop technology and the centralized solution. After sizing the systems, the comparative energy, economic and carbon emission studies of the systems, in which their application has been found to be possible, are presented. After analysing the systems covered and the studies performed, it is concluded not only about the best applicable system, but also about the limitations found in each of the others. Keywords: Natural refrigerants, Commercial refrigeration, Coolbox, Waterloop
- 1 August 2018
- Published by Elsevier in Energy Conversion and Management
- Vol. 169, 383-389
Ash deposit formation during the combustion of pulverized grape pomace in a drop tube furnace
- 1 August 2018
- Published by Elsevier in Energy Conversion and Management
- Vol. 169, 383-389
Ash deposit formation during the combustion of pulverized grape pomace in a drop tube furnace
- 24 November 2014
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 29 (2) , 1130-1136
Destruction of the Tar Present in Syngas by Combustion in Porous Media
- 24 November 2014
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 29 (2) , 1130-1136
Destruction of the Tar Present in Syngas by Combustion in Porous Media
- 1 January 2009
- Published by Elsevier in Proceedings of the Combustion Institute
- Vol. 32 (2) , 2641-2648
NO control through reburning using biomass in a laboratory furnace: Effect of particle size
- 1 January 2009
- Published by Elsevier in Proceedings of the Combustion Institute
- Vol. 32 (2) , 2641-2648
NO control through reburning using biomass in a laboratory furnace: Effect of particle size