Hui Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hui Wang has a total of 191 co-authors. Here are the top co-authors by number of shared publications:
- Claudia Calcagno
Integrated Research Facility at Fort Detrick, National Institute of Allergy and Infectious Diseases, National Institutes of Health, Fort Detrick, Frederick, MD, USA.
4 shared publications - Jens H. Kuhn
Department of Microbiology, Global Health Emergent Pathogens Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA
4 shared publications - Philip J. Sayre
Integrated Research Facility at Fort Detrick, National Institute of Allergy and Infectious Diseases, National Institutes of Health, Fort Detrick, Frederick, MD, USA
4 shared publications - Anya Crane
Integrated Research Facility at Fort Detrick, National Institute of Allergy and Infectious Diseases, National Institutes of Health, Fort Detrick, Frederick, MD, USA
3 shared publications - David H. O'COnnor
Department of Pathology and Laboratory Medicine, University of Wisconsin-Madison, Madison, Wisconsin, United States of America
3 shared publications - Gabriella Worwa
Integrated Research Facility at Fort Detrick, Division of Clinical Research, National Institute of Allergy and Infectious Diseases, National Institutes of Health, Fort Detrick, Frederick, MD, USA
3 shared publications
Latest Publications
- Open Access
- 29 May 2026
- Published by Springer Nature in EJNMMI Research
[18F]FDG PET/CT is a quantitative tool to probe vascular inflammation and immune system metabolic activation in atherosclerotic nonhuman primates
Atherosclerosis is a major global health concern, necessitating advanced research models to better understand pathophysiology and inform potential interventions. Due to their physiological similarities to humans, nonhuman primates (NHPs), particularly crab-eating macaques, are valuable models to study the development and progression of atherosclerosis. This retrospective study utilized quantitative 2-deoxy-2-[fluorine-18]fluoro-D-glucose ([18F]FDG) positron emission tomography-computed tomography (PET/CT) to characterize a cohort of crab-eating macaques with diet-induced atherosclerosis. We evaluated [18F]FDG uptake in the vasculature, bone marrow, spleen, and adipose tissues from macaques fed an atherogenic diet compared with those fed a regular chow diet. [18F]FDG uptake was significantly higher in the vasculature, bone marrow, and adipose tissues of macaques on the atherogenic diet, along with increased vascular calcification. Correlation analyses demonstrated moderate to strong associations among vascular inflammation, calcification, and metabolic activity in the bone marrow and adipose tissues. We provide a robust methodology for quantitative PET/CT imaging analysis of atherosclerosis in an established NHP model. Our work adds to the research toolkit and highlights the translational potential of imaging in NHP models to investigate systemic cardiovascular disease, including of fundamental pathobiology and of targeted interventions.
- 29 May 2026
- Published by Springer Nature in EJNMMI Research
Open Access[18F]FDG PET/CT is a quantitative tool to probe vascular inflammation and immune system metabolic activation in atherosclerotic nonhuman primates
Atherosclerosis is a major global health concern, necessitating advanced research models to better understand pathophysiology and inform potential interventions. Due to their physiological similarities to humans, nonhuman primates (NHPs), particularly crab-eating macaques, are valuable models to study the development and progression of atherosclerosis. This retrospective study utilized quantitative 2-deoxy-2-[fluorine-18]fluoro-D-glucose ([18F]FDG) positron emission tomography-computed tomography (PET/CT) to characterize a cohort of crab-eating macaques with diet-induced atherosclerosis. We evaluated [18F]FDG uptake in the vasculature, bone marrow, spleen, and adipose tissues from macaques fed an atherogenic diet compared with those fed a regular chow diet. [18F]FDG uptake was significantly higher in the vasculature, bone marrow, and adipose tissues of macaques on the atherogenic diet, along with increased vascular calcification. Correlation analyses demonstrated moderate to strong associations among vascular inflammation, calcification, and metabolic activity in the bone marrow and adipose tissues. We provide a robust methodology for quantitative PET/CT imaging analysis of atherosclerosis in an established NHP model. Our work adds to the research toolkit and highlights the translational potential of imaging in NHP models to investigate systemic cardiovascular disease, including of fundamental pathobiology and of targeted interventions.
- Open Access
- 11 September 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (18) , 2310
Computed Tomography Radiomics and Machine Learning for Prediction of Histology-Based Hepatic Steatosis Scores
Background/Objective: Computed tomography (CT) can be used to non-invasively assess the health of the liver; however, radiologist evaluation and simple thresholding alone are insufficient for diagnosis of hepatic steatosis, necessitating biopsies. This study explored CT radiomics and machine learning to enable non-invasive, objective, and quantitative prediction of steatosis severity across the macaque liver. Methods: In this retrospective study, CT images of 42 crab-eating macaques (age [yr] = 6.1 ± 1.7; sex [male/female] = 26/16) with varying degrees of hepatic steatosis were analyzed, and the results were compared to histology-based steatosis scores of livers from the same animals. After extracting radiomic features, a thorough array of statistical analyses, feature selection techniques, and machine learning models were applied to identify a distinct radiomic signature of histologically defined hepatic steatosis. Results: We identified 12 radiomic features that correlated with steatosis scores, and hierarchical clustering based on radiomic attributes alone revealed clusters roughly aligning with steatosis severity groups. The k-nearest neighbors model architecture best predicted histopathologic steatosis scores in both classification and regression tasks (area under the receiver operating characteristic curve [AUC ROC] = 0.89 ± 0.09; root-mean-square error [RMSE] = 0.60 ± 0.10). Feature analyses identified seven key radiomic features (six first-order features and one gray-level co-occurrence matrix feature) that were most important when predicting steatosis. Conclusions: We identified a CT radiomic signature of steatosis and demonstrated that histology-based steatosis scores can be predicted non-invasively and objectively using machine learning and CT radiomics as a potential alternative to invasive core biopsies. Given the strong similarities in liver structure, liver function, and hepatic steatosis pathophysiology between macaques and humans, these findings have the potential to translate to humans.
- 11 September 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (18) , 2310
Open AccessComputed Tomography Radiomics and Machine Learning for Prediction of Histology-Based Hepatic Steatosis Scores
Background/Objective: Computed tomography (CT) can be used to non-invasively assess the health of the liver; however, radiologist evaluation and simple thresholding alone are insufficient for diagnosis of hepatic steatosis, necessitating biopsies. This study explored CT radiomics and machine learning to enable non-invasive, objective, and quantitative prediction of steatosis severity across the macaque liver. Methods: In this retrospective study, CT images of 42 crab-eating macaques (age [yr] = 6.1 ± 1.7; sex [male/female] = 26/16) with varying degrees of hepatic steatosis were analyzed, and the results were compared to histology-based steatosis scores of livers from the same animals. After extracting radiomic features, a thorough array of statistical analyses, feature selection techniques, and machine learning models were applied to identify a distinct radiomic signature of histologically defined hepatic steatosis. Results: We identified 12 radiomic features that correlated with steatosis scores, and hierarchical clustering based on radiomic attributes alone revealed clusters roughly aligning with steatosis severity groups. The k-nearest neighbors model architecture best predicted histopathologic steatosis scores in both classification and regression tasks (area under the receiver operating characteristic curve [AUC ROC] = 0.89 ± 0.09; root-mean-square error [RMSE] = 0.60 ± 0.10). Feature analyses identified seven key radiomic features (six first-order features and one gray-level co-occurrence matrix feature) that were most important when predicting steatosis. Conclusions: We identified a CT radiomic signature of steatosis and demonstrated that histology-based steatosis scores can be predicted non-invasively and objectively using machine learning and CT radiomics as a potential alternative to invasive core biopsies. Given the strong similarities in liver structure, liver function, and hepatic steatosis pathophysiology between macaques and humans, these findings have the potential to translate to humans.
- Open Access
- 31 August 2025
- Published by MDPI AG in Current Oncology
- Vol. 32 (9) , 487
Safety of Combination TARE and SBRT in Hepatocellular Carcinoma: A Review of Literature & Single-Center Case Series
Hepatocellular carcinoma (HCC) is the most common primary liver cancer. At the time of diagnosis, many HCC patients are not candidates for surgical resection and are considered for other locoregional therapies, including transarterial radioembolization (TARE) and stereotactic body radiation therapy (SBRT). To date only a few studies have explored the safety and efficacy of combining TARE and SBRT. Therefore, we aimed to evaluate it. Patients who received both SBRT and TARE from 2016 to 2024 were retrospectively evaluated for treatment-related toxicity based on criteria for adverse events (CTCAE v4.0). Treatment response was evaluated by modified response evaluation criteria for solid tumors (m-RECIST). We identified 12 patients with median age of 66.5 (range: 40, 87) and median follow up of 12 months. The median time between TARE and SBRT was 6.5 months (range: 1.5 to 24). Following the second treatment, ALBI grade remined the same among all patients at 3-month post treatment compared to baseline. Baseline CP was A among all patients and remained unchanged during follow-up and no higher than grade 3 clinical or biochemical toxicity was seen. The objective response rate (ORR) among patients receiving treatment to the same lesion was 100%. The combination treatment was consistent with prior studies in which the combination of TARE and SBRT has been shown to have good local control with few cases of grade 3 toxicity. Our study demonstrates that treatment with TARE and SBRT was safe and effective among our small sample of patients.
- 31 August 2025
- Published by MDPI AG in Current Oncology
- Vol. 32 (9) , 487
Open AccessSafety of Combination TARE and SBRT in Hepatocellular Carcinoma: A Review of Literature & Single-Center Case Series
Hepatocellular carcinoma (HCC) is the most common primary liver cancer. At the time of diagnosis, many HCC patients are not candidates for surgical resection and are considered for other locoregional therapies, including transarterial radioembolization (TARE) and stereotactic body radiation therapy (SBRT). To date only a few studies have explored the safety and efficacy of combining TARE and SBRT. Therefore, we aimed to evaluate it. Patients who received both SBRT and TARE from 2016 to 2024 were retrospectively evaluated for treatment-related toxicity based on criteria for adverse events (CTCAE v4.0). Treatment response was evaluated by modified response evaluation criteria for solid tumors (m-RECIST). We identified 12 patients with median age of 66.5 (range: 40, 87) and median follow up of 12 months. The median time between TARE and SBRT was 6.5 months (range: 1.5 to 24). Following the second treatment, ALBI grade remined the same among all patients at 3-month post treatment compared to baseline. Baseline CP was A among all patients and remained unchanged during follow-up and no higher than grade 3 clinical or biochemical toxicity was seen. The objective response rate (ORR) among patients receiving treatment to the same lesion was 100%. The combination treatment was consistent with prior studies in which the combination of TARE and SBRT has been shown to have good local control with few cases of grade 3 toxicity. Our study demonstrates that treatment with TARE and SBRT was safe and effective among our small sample of patients.
- 1 November 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 10 (06) , 066004-20
Repeatability of computed tomography liver radiomic features in a nonhuman primate model of diet-induced steatosis
PurposeWe describe a method to identify repeatable liver computed tomography (CT) radiomic features, suitable for detection of steatosis, in nonhuman primates. Criteria used for feature selection exclude nonrepeatable features and may be useful to improve the performance and robustness of radiomics-based predictive models.ApproachSix crab-eating macaques were equally assigned to two experimental groups, fed regular chow or an atherogenic diet. High-resolution CT images were acquired over several days for each macaque. First-order and second-order radiomic features were extracted from six regions in the liver parenchyma, either with or without liver-to-spleen intensity normalization from images reconstructed using either a standard (B-filter) or a bone-enhanced (D-filter) kernel. Intrasubject repeatability of each feature was assessed using a paired t-test for all scans and the minimum p-value was identified for each macaque. Repeatable features were defined as having a minimum p-value among all macaques above the significance level after Bonferroni’s correction. Features showing a significant difference with respect to diet group were identified using a two-sample t-test.ResultsA list of repeatable features was generated for each type of image. The largest number of repeatable features was achieved from spleen-normalized D-filtered images, which also produced the largest number of second-order radiomic features that were repeatable and different between diet groups.ConclusionsRepeatability depends on reconstruction kernel and normalization. Features were quantified and ranked based on their repeatability. Features to be excluded for more robust models were identified. Features that were repeatable but different between diet groups were also identified.
- 1 November 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 10 (06) , 066004-20
Repeatability of computed tomography liver radiomic features in a nonhuman primate model of diet-induced steatosis
PurposeWe describe a method to identify repeatable liver computed tomography (CT) radiomic features, suitable for detection of steatosis, in nonhuman primates. Criteria used for feature selection exclude nonrepeatable features and may be useful to improve the performance and robustness of radiomics-based predictive models.ApproachSix crab-eating macaques were equally assigned to two experimental groups, fed regular chow or an atherogenic diet. High-resolution CT images were acquired over several days for each macaque. First-order and second-order radiomic features were extracted from six regions in the liver parenchyma, either with or without liver-to-spleen intensity normalization from images reconstructed using either a standard (B-filter) or a bone-enhanced (D-filter) kernel. Intrasubject repeatability of each feature was assessed using a paired t-test for all scans and the minimum p-value was identified for each macaque. Repeatable features were defined as having a minimum p-value among all macaques above the significance level after Bonferroni’s correction. Features showing a significant difference with respect to diet group were identified using a two-sample t-test.ResultsA list of repeatable features was generated for each type of image. The largest number of repeatable features was achieved from spleen-normalized D-filtered images, which also produced the largest number of second-order radiomic features that were repeatable and different between diet groups.ConclusionsRepeatability depends on reconstruction kernel and normalization. Features were quantified and ranked based on their repeatability. Features to be excluded for more robust models were identified. Features that were repeatable but different between diet groups were also identified.
- 31 October 2023
- Published by Elsevier in Journal of Thoracic Oncology
- Vol. 18 (11) , S454-S455
EP04.01-03 Advancing Malignancy Risk Stratification for Early-Stage Cancers in Lung Nodules by Combined Imaging and Electrical Impedance Analysis
- 31 October 2023
- Published by Elsevier in Journal of Thoracic Oncology
- Vol. 18 (11) , S454-S455
EP04.01-03 Advancing Malignancy Risk Stratification for Early-Stage Cancers in Lung Nodules by Combined Imaging and Electrical Impedance Analysis
- 20 October 2023
- Published by Elsevier in Annals of Oncology
- Vol. 34, S736
1272P Postoperative survival prediction in non-small cell lung cancer patients based on driver genotypes
- 20 October 2023
- Published by Elsevier in Annals of Oncology
- Vol. 34, S736
1272P Postoperative survival prediction in non-small cell lung cancer patients based on driver genotypes
- 10 April 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12468, 296-308
Determination of reproducible radiomic features for diagnosis of fatty liver disease in a crab-eating macaque model
Evaluation of the intra-subject reproducibility of radiomic features is pivotal but challenging because it requires multiple replicate measurements, typically lacking in the clinical setting. Radiomics analysis based on computed tomography (CT) has been increasingly used to characterize liver malignancies and liver diffusive diseases. However, radiomic features are greatly affected by scanning parameters and reconstruction kernels, among other factors. In this study, we examined the effects of diets, reconstruction kernels, and liver-to-spleen normalization on the intra-subject reproducibility of radiomic features. The final goal of this work is to create a framework that may help identify reproducible radiomics features suitable for further diagnosis and grading of fatty liver disease in nonhuman primates using radiomics analysis. As a first step, the identification of reproducible features is essential. To accomplish this aim, we retrospectively analyzed serial CT images from two groups of crab-eating macaques, fed a normal or atherogenic diet. Serial CT examinations resulted in 45 high-resolution scans. From each scan, two CT images were reconstructed using a standard B kernel and a bone-enhanced D kernel, with and without normalization relative to the spleen. Radiomic features were extracted from six regions in the liver parenchyma. Intra-subject variability showed that many features are fully reproducible regardless of liver disease status whereas others are significantly different in a limited number of tests. Features significantly different between the normal and atherogenic diet groups were also investigated. Reproducible features were listed, with normalized images having more reproducible features.
- 10 April 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12468, 296-308
Determination of reproducible radiomic features for diagnosis of fatty liver disease in a crab-eating macaque model
Evaluation of the intra-subject reproducibility of radiomic features is pivotal but challenging because it requires multiple replicate measurements, typically lacking in the clinical setting. Radiomics analysis based on computed tomography (CT) has been increasingly used to characterize liver malignancies and liver diffusive diseases. However, radiomic features are greatly affected by scanning parameters and reconstruction kernels, among other factors. In this study, we examined the effects of diets, reconstruction kernels, and liver-to-spleen normalization on the intra-subject reproducibility of radiomic features. The final goal of this work is to create a framework that may help identify reproducible radiomics features suitable for further diagnosis and grading of fatty liver disease in nonhuman primates using radiomics analysis. As a first step, the identification of reproducible features is essential. To accomplish this aim, we retrospectively analyzed serial CT images from two groups of crab-eating macaques, fed a normal or atherogenic diet. Serial CT examinations resulted in 45 high-resolution scans. From each scan, two CT images were reconstructed using a standard B kernel and a bone-enhanced D kernel, with and without normalization relative to the spleen. Radiomic features were extracted from six regions in the liver parenchyma. Intra-subject variability showed that many features are fully reproducible regardless of liver disease status whereas others are significantly different in a limited number of tests. Features significantly different between the normal and atherogenic diet groups were also investigated. Reproducible features were listed, with normalized images having more reproducible features.
- Open Access
Intramuscular [18F]F-FDG Administration for Successful PET Imaging of Golden Hamsters in a Maximum Containment Laboratory Setting
Positron emission tomography (PET) is becoming an important tool for the investigation of emerging infectious diseases in animal models. Usually, PET imaging is performed after intravenous (IV) radiotracer administration. However, IV injections are difficult to perform in some small animals, such as golden hamsters. This challenge is particularly evident in longitudinal imaging studies, and even more so in maximum containment settings used to study high-consequence pathogens. We propose the use of intramuscular (IM) administration of 2-deoxy-2[18F]fluoro-D-glucose ([18F]F-FDG) for PET imaging of hamsters in a biosafety level 4 (BSL-4) laboratory setting. After [18F]F-FDG administration via IM or IV (through surgically implanted vascular access ports), eight hamsters underwent static or dynamic PET scans. Time–activity curves (TACs) and standardized uptake values (SUVs) in major regions of interest (ROIs) were used to compare the two injection routes. Immediately after injection, TACs differed between the two routes. At 60 min post-injection, [18F]F-FDG activity for both routes reached a plateau in most ROIs except the brain, with higher accumulation in the liver, lungs, brain, and nasal cavities observed in the IM group. IM delivery of [18F]F-FDG is an easy, safe, and reliable alternative for longitudinal PET imaging of hamsters in a BSL-4 laboratory setting.
Open AccessIntramuscular [18F]F-FDG Administration for Successful PET Imaging of Golden Hamsters in a Maximum Containment Laboratory Setting
Positron emission tomography (PET) is becoming an important tool for the investigation of emerging infectious diseases in animal models. Usually, PET imaging is performed after intravenous (IV) radiotracer administration. However, IV injections are difficult to perform in some small animals, such as golden hamsters. This challenge is particularly evident in longitudinal imaging studies, and even more so in maximum containment settings used to study high-consequence pathogens. We propose the use of intramuscular (IM) administration of 2-deoxy-2[18F]fluoro-D-glucose ([18F]F-FDG) for PET imaging of hamsters in a biosafety level 4 (BSL-4) laboratory setting. After [18F]F-FDG administration via IM or IV (through surgically implanted vascular access ports), eight hamsters underwent static or dynamic PET scans. Time–activity curves (TACs) and standardized uptake values (SUVs) in major regions of interest (ROIs) were used to compare the two injection routes. Immediately after injection, TACs differed between the two routes. At 60 min post-injection, [18F]F-FDG activity for both routes reached a plateau in most ROIs except the brain, with higher accumulation in the liver, lungs, brain, and nasal cavities observed in the IM group. IM delivery of [18F]F-FDG is an easy, safe, and reliable alternative for longitudinal PET imaging of hamsters in a BSL-4 laboratory setting.
- Open Access
- 1 March 2022
- Published by Elsevier in Acta Tropica
- Vol. 227, 106290
Serum platelet-derived growth factor-BB levels as a potential biomarker in assessing the metabolic activity of lesions in alveolar echinococcosis patients
- 1 March 2022
- Published by Elsevier in Acta Tropica
- Vol. 227, 106290
Open AccessSerum platelet-derived growth factor-BB levels as a potential biomarker in assessing the metabolic activity of lesions in alveolar echinococcosis patients