BSBura Sindhupakorn

Bura Sindhupakorn

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bura Sindhupakorn has a total of 20 co-authors. Here are the top co-authors by number of shared publications:

  • Supakit Rooppakhun

    School of Mechanical Engineering, Institute of engineering, Suranaree University of Technology, Nakhon Ratchasima 30000, Thailand

    2 shared publications
  • Suwittaya Thienpratharn

    School of orthopedic, Institute of medicine, Suranaree University of Technology, 111 University Ave, Muang District, Nakhon Ratchasima, Nakhon Ratchasima, 30000, Thailand

    2 shared publications
  • Anupong Sukee

    School of Biomedical Engineering Innovation, Suranaree University of Technology, 111 University Avenue, Muang District, Nakhon Ratchasima, 30000, Thailand

    1 shared publication
  • Atcharawan Rattanasak

    School of Telecommunication Engineering, Suranaree University of Technology, Nakhon Ratchasima 30000, Thailand

    1 shared publication
  • Chotchuang Phombut

    School of Mechanical Engineering, Institute of engineering, Suranaree University of Technology, Nakhon Ratchasima 30000, Thailand

    1 shared publication
  • Darawan Jomkoh

    School of orthopedic, Institute of medicine, Suranaree University of Technology, 111 University Ave, Muang District, Nakhon Ratchasima, Nakhon Ratchasima, 30000, Thailand

    1 shared publication

Latest Publications

  • Open Access

    Real-Time Gait Phase Detection Using Wearable Sensors for Transtibial Prosthesis Based on a kNN Algorithm

    by Atcharawan Rattanasak, Peerapong Uthansakul, Monthippa Uthansakul, Talit Jumphoo, Khomdet Phapatanaburi, Bura Sindhupakorn, Supakit Rooppakhun

    Those with disabilities who have lost their legs must use a prosthesis to walk. However, traditional prostheses have the disadvantage of being unable to move and support the human gait because there are no mechanisms or algorithms to control them. This makes it difficult for the wearer to walk. To overcome this problem, we developed an insole device with a wearable sensor for real-time gait phase detection based on the kNN (k-nearest neighbor) algorithm for prosthetic control. The kNN algorithm is used with the raw data obtained from the pressure sensors in the insole to predict seven walking phases, i.e., stand, heel strike, foot flat, midstance, heel off, toe-off, and swing. As a result, the predictive decision in each gait cycle to control the ankle movement of the transtibial prosthesis improves with each walk. The results in this study can provide 81.43% accuracy for gait phase detection, and can control the transtibial prosthetic effectively at the maximum walking speed of 6 km/h. Moreover, this insole device is small, lightweight and unaffected by the physical factors of the wearer.


  • Open Access

    Fabrication of an acetone gas sensor based on Si-doped WO3 nanorods prepared by reactive magnetron co-sputtering with OAD technique

    by Waraporn Sucharitakul, Anupong Sukee, Pimchanok Leuasoongnoen, Mati Horprathum, Tossaporn Lertvanithphol, Pattanaphong Janphuang, Pusit Mitsomwang, Bura Sindhupakorn

    Gas sensing technology is currently applied in a variety of applications. In medical applications, gas sensors can be used for the detection of the biomarker in various diseases, metabolic disorders, diabetes mellitus, asthma, renal, liver diseases, and lung cancer. In this study, we present acetone sensing characteristics of Si-doped WO3 nanorods prepared by a DC reactive magnetron co-sputtering with an oblique-angle deposition (OAD) technique. The composition of Si-doped in WO3 has been studied by varying the electrical input power applied to the Si sputtered target. The nanorods film was constructed at the glancing angle of 85°. After deposition, the films were annealed at 400 °C for 4 h in the air. The microstructures and phases of the materials were characterized by x-ray photoelectron spectroscopy (XPS), x-ray diffraction (XRD), and field-emission scanning electron microscopy (FESEM). The results showed that 1.43 wt% Si-doped WO3 thin film exhibited the maximum response of 5.92 towards 100 ppm of acetone at performing temperature (350 °C), purifying dry air carrier. The process exposed in this work demonstrated the potential of high sensitivity acetone gas sensor at low concentration and may be used as an effective tool for diabetes non-invasive monitoring.


  • Open Access

    Morphometric Analysis and Three-Dimensional Computed Tomography Reconstruction of Thai Distal Femur

    by Chotchuang Phombut, Supakit Rooppakhun, Bura Sindhupakorn

    This study evaluates the distal femur morphology of the Thai population using a three-dimensional (3D) measurement method, measuring the distance between the triangular point of the femoral 3D model. The 3D model of 360 Thai femoral obtained from 180 volunteers (90 males, 90 females; range 20–50 years, average 32.8 years) was created using reverse engineering techniques from computed tomography imaging data. Using the 3D identified landmark method, the morphometric parameters evaluated included transepicondylar axis length (TEA), mediolateral length (ML), anteroposterior width (AP), medial anteroposterior width (MAP), lateral anteroposterior width (LAP), medial condyle width (MCW), lateral condyle width (LCW), intercondylar notch width (WIN), intercondylar notch depth (DIN), medial posterior condyle height (MPC), lateral posterior condyle height (LPC), femoral aspect ratio (ML/AP), lateral femoral aspect ratio (ML/LAP), and medial femoral aspect ratio (ML/MAP). The measured data were summarized for the analysis of an average value and standard deviation. Statistical analysis was performed using the independent samples t-test, unequal variances t-test, and linear regression. A p-value less than 0.05 (<0.05) was regarded as statistically significant and indicates strong evidence of the hypothesis. Additionally, the K-means clustering analysis of Thai distal femoral to the optimum size of the prosthesis with the correlation between ML length and AP width was performed. The results found that the morphometric parameters of the Thai male distal femur were significantly different and higher than those of Thai females, except for the ratio of ML/AP and ML/MAP. Comparatively, there was a significant difference between the specific size of Thai distal femur and that of the Korean population, which was also smaller than that for Caucasians. In addition, there was a mismatch between the distal femoral component sizing of knee prosthesis and what is available and commonly used in Thailand. At least six sizes of ML and/or AP should be recommended for the reasonable design of distal femoral prosthesis for covering the anatomy of Thais. These data are useful for predicting the morphometric parameters in forensic anthropology and provide basic data for the design of knee prostheses suitable for the Thai population.


  • Open Access

    A home visit program versus a non-home visit program in total knee replacement patients: a randomized controlled trial

    by Bura Sindhupakorn, Piya-On Numpaisal, Suwittaya Thienpratharn, Darawan Jomkoh

    Background: The goals in total knee replacement (TKR) are pain relief, restore functions, and improve quality of life. Surgical outcomes were not related to patients’ satisfaction. Low 1-year WOMAC especially in the first 6 weeks and painful TKR related to patient dissatisfied. To improve satisfaction, we created the home visit program (TKR-H) after hospital discharge. INHOMESSS was the rationale for home visit activities. Methods: We recruited 52 TKRs. Four TKRs were excluded. We used simple randomization for 24 patients as a home visit (TKR-H) and 24 patients as a non-home visit (TKR). Patients were evaluated by general demographics, pain intensity scores (VAS), range of motion (ROM), WOMAC, knee scores, and functional scores as a primary objective. A duration for gait aid independent and patient’s satisfaction score as secondary objective. The study was 6 weeks after surgery. Results: TKR-H and TKR had significant differences in the mean of WOMAC score (88.29 ± 10.66 vs. 68.00 ± 12.47, respectively, P < 0.001), pain score (VAS) (6.25 ± 10.13 vs. 35.67 ± 22.05, respectively, P < 0.001), knee score (81.67 ± 10.08 vs. 68.38 ± 6.45, respectively, P < 0.001), functional score (77.83 ± 4.22 vs. 73.70 ± 7.48, respectively, P = 0.037), and range of motion (107.71 ± 8.47 vs. 98.17 ± 9.57, respectively, P = 0.001). The patient’s satisfaction score in TKR-H group (4.71 ± 0.46) was significantly higher than the TKR group (4.13 ± 0.45) (P < 0.001) and time to gait aid independent (2.75 ± 0.99 vs. 3.71 ± 1.23, respectively, P = 0.005). Conclusion: Our TKR-H showed better clinical outcomes and satisfaction than non-home visit. The rationale in TKR-H improves satisfaction after total knee replacement. Trial registration: TCTR20190514001.