Edward Cazalas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Edward Cazalas has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Igor Jovanovic
Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, USA
5 shared publicationsIsaac Childres
Department of Physics and Astronomy, Purdue University, West Lafayette, Indiana 47907, USA
5 shared publications- Yong P. Chen
Department of Physics and Astronomy, Purdue University, West Lafayette, IN 47907, USA
3 shared publications Amol Patil
Canberra Nuclear Industries, Meridien, CT, USA
2 shared publicationsBiddut K. Sarker
Department of Physics and Astronomy, Purdue University, West Lafayette, Indiana 47907, USA
2 shared publications- Ting-Fung Chung
Department of Physics and Astronomy, Purdue University, West Lafayette, IN 47907, USA
2 shared publications
Latest Publications
- Open Access
- 19 June 2026
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 99 (1186) , 2117-2128
Development of in situ dosimetry for FLASH proton radiotherapy via organic scintillating fibers
Objectives: This work presents the design, development, and initial proof-of-concept testing of a dosimetry device intended for FLASH radiotherapy. Methods: The system incorporates organic scintillating fibers coupled to a silicon photomultiplier (SiPM) and an FPGA-based readout, with fiber geometry optimized to minimize perturbations to a clinical proton beam, as confirmed through measurements at the Huntsman Cancer Institute (HCI). Results: Tests using a portable X-ray unit demonstrated a strong correlation between integrated charge and delivered dose (up to ∼35 mrem s−1) and showed that the detector can respond on nanosecond timescales, enabling rapid safety interlock triggering with minimal latency. Conclusion: Preliminary proton irradiations at HCI further indicated that the device can resolve individual beam pulses, a capability valuable for both FLASH research and conventional radiotherapy. Advances in knowledge: These results highlight the need for continued refinement of the experimental setup, readout electronics, and detector performance to fully realize real-time, in situ dose and pulse monitoring.
- 19 June 2026
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 99 (1186) , 2117-2128
Open AccessDevelopment of in situ dosimetry for FLASH proton radiotherapy via organic scintillating fibers
Objectives: This work presents the design, development, and initial proof-of-concept testing of a dosimetry device intended for FLASH radiotherapy. Methods: The system incorporates organic scintillating fibers coupled to a silicon photomultiplier (SiPM) and an FPGA-based readout, with fiber geometry optimized to minimize perturbations to a clinical proton beam, as confirmed through measurements at the Huntsman Cancer Institute (HCI). Results: Tests using a portable X-ray unit demonstrated a strong correlation between integrated charge and delivered dose (up to ∼35 mrem s−1) and showed that the detector can respond on nanosecond timescales, enabling rapid safety interlock triggering with minimal latency. Conclusion: Preliminary proton irradiations at HCI further indicated that the device can resolve individual beam pulses, a capability valuable for both FLASH research and conventional radiotherapy. Advances in knowledge: These results highlight the need for continued refinement of the experimental setup, readout electronics, and detector performance to fully realize real-time, in situ dose and pulse monitoring.
- Open Access
- 5 September 2025
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 226, 112148
A review of radiation-induced damage to quantum dots
- 5 September 2025
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 226, 112148
Open AccessA review of radiation-induced damage to quantum dots
- Open Access
- 30 June 2025
- Published by Wiley
Radiation Effects on Stepper Motors and Lubricants: A Review
The use of electrical motors and other remote systems are important tools in radiation environments. Certain harsh radiation environments, such as particle accelerators, require the use of remote systems during operation. Stepper motors are one motor, in particular, that have acquired interest in the nuclear field for use in these remote systems. The stepper motor’s precision in rotation and holding is a highly desired quality. In this review, the stepper motor is examined for use in radiation environments. The different mechanical parts are introduced and examined from the broader literature of previous work. We attempt to explain the different radiation destructive mechanisms involved with each part of the stepper motor and how the mechanics are affected. Current and past research is explored, identifying either radiation hard alternatives or thresholds of the materials involved, and a general review of stepper motor radiation effects as available in literature.
- 30 June 2025
- Published by Wiley
Open AccessRadiation Effects on Stepper Motors and Lubricants: A Review
The use of electrical motors and other remote systems are important tools in radiation environments. Certain harsh radiation environments, such as particle accelerators, require the use of remote systems during operation. Stepper motors are one motor, in particular, that have acquired interest in the nuclear field for use in these remote systems. The stepper motor’s precision in rotation and holding is a highly desired quality. In this review, the stepper motor is examined for use in radiation environments. The different mechanical parts are introduced and examined from the broader literature of previous work. We attempt to explain the different radiation destructive mechanisms involved with each part of the stepper motor and how the mechanics are affected. Current and past research is explored, identifying either radiation hard alternatives or thresholds of the materials involved, and a general review of stepper motor radiation effects as available in literature.
- 21 January 2022
- Published by Wolters Kluwer Health in Health Physics
- Vol. 122 (4) , 480-487
Retrieval and Characterization of a Plutonium-beryllium Source at the University of Utah
A shielded neutron irradiation facility has been constructed to contain a 74 GBq plutonium-beryllium neutron source at the University of Utah. Due to lack of information and recent use, the GEANT4 Monte Carlo Toolkit was used to perform dose assessments and validation of the designed shield and beam port for storage and operational geometries where the source was to be placed. Borated polyethylene was used as the primary shielding material with a lead-lined beam port to collimate neutrons and reduce gamma rays within the active beam profile. The lead lining was found to reduce the gamma-to-neutron ratio within the profile to 0.259 ± 0.001 and maintain an average neutron flux of 4,633.7 ± 10.2 n cm−2 s−1. The measured dose rate of the source at 30 cm from its constructed storage configuration was found to be 22.3 ± 1.1 μSv h−1 and in good agreement with simulated values. This was also close to the target rate of 20 μSv h−1, the public limit for whole-body dose accumulation, imposed on the design. Measurements of the source during its retrieval and placement into the shield show good agreement with the simulated results and provide a strong validation for the future use of the source in experiments at the University of Utah.
- 21 January 2022
- Published by Wolters Kluwer Health in Health Physics
- Vol. 122 (4) , 480-487
Retrieval and Characterization of a Plutonium-beryllium Source at the University of Utah
A shielded neutron irradiation facility has been constructed to contain a 74 GBq plutonium-beryllium neutron source at the University of Utah. Due to lack of information and recent use, the GEANT4 Monte Carlo Toolkit was used to perform dose assessments and validation of the designed shield and beam port for storage and operational geometries where the source was to be placed. Borated polyethylene was used as the primary shielding material with a lead-lined beam port to collimate neutrons and reduce gamma rays within the active beam profile. The lead lining was found to reduce the gamma-to-neutron ratio within the profile to 0.259 ± 0.001 and maintain an average neutron flux of 4,633.7 ± 10.2 n cm−2 s−1. The measured dose rate of the source at 30 cm from its constructed storage configuration was found to be 22.3 ± 1.1 μSv h−1 and in good agreement with simulated values. This was also close to the target rate of 20 μSv h−1, the public limit for whole-body dose accumulation, imposed on the design. Measurements of the source during its retrieval and placement into the shield show good agreement with the simulated results and provide a strong validation for the future use of the source in experiments at the University of Utah.
- Open Access
- 25 November 2019
- Published by AIP Publishing in Applied Physics Letters
- Vol. 115 (22) , 223504
Gamma-ray radiation effects in graphene-based transistors with h-BN nanometer film substrates
Radiation effects on graphene field effect transistors (GFETs) with hexagonal boron nitride (h-BN) thin film substrates are investigated using 60Co gamma-ray radiation. This study examines the radiation response using many samples with varying h-BN film thicknesses (1.6 and 20 nm thickness) and graphene channel lengths (5 and 10 μm). These samples were exposed to a total ionizing dose of approximately 1 Mrad(Si). I-V measurements were taken at fixed time intervals between irradiations and postirradiation. Dirac point voltage and current are extracted from the I-V measurements, as well as mobility, Dirac voltage hysteresis, and the total number of GFETs that remain properly operational. The results show a decrease in Dirac voltage during irradiation, with a rise of this voltage and permanent drop in Dirac current postirradiation. 1.6 nm h-BN substrate GFETs show an increase in mobility during irradiation, which drops back to preirradiation conditions in postirradiation measurements. Hysteretic changes to the Dirac voltage are the strongest during irradiation for the 20 nm thick h-BN substrate GFETs and after irradiation for the 1.6 nm thick h-BN GFETs. Failure rates were similar for most GFET types during irradiation; however, after irradiation, GFETs with 20 nm h-BN substrates experienced substantially more failures compared to 1.6 nm h-BN substrate GFETs.
- 25 November 2019
- Published by AIP Publishing in Applied Physics Letters
- Vol. 115 (22) , 223504
Open AccessGamma-ray radiation effects in graphene-based transistors with h-BN nanometer film substrates
Radiation effects on graphene field effect transistors (GFETs) with hexagonal boron nitride (h-BN) thin film substrates are investigated using 60Co gamma-ray radiation. This study examines the radiation response using many samples with varying h-BN film thicknesses (1.6 and 20 nm thickness) and graphene channel lengths (5 and 10 μm). These samples were exposed to a total ionizing dose of approximately 1 Mrad(Si). I-V measurements were taken at fixed time intervals between irradiations and postirradiation. Dirac point voltage and current are extracted from the I-V measurements, as well as mobility, Dirac voltage hysteresis, and the total number of GFETs that remain properly operational. The results show a decrease in Dirac voltage during irradiation, with a rise of this voltage and permanent drop in Dirac current postirradiation. 1.6 nm h-BN substrate GFETs show an increase in mobility during irradiation, which drops back to preirradiation conditions in postirradiation measurements. Hysteretic changes to the Dirac voltage are the strongest during irradiation for the 20 nm thick h-BN substrate GFETs and after irradiation for the 1.6 nm thick h-BN GFETs. Failure rates were similar for most GFET types during irradiation; however, after irradiation, GFETs with 20 nm h-BN substrates experienced substantially more failures compared to 1.6 nm h-BN substrate GFETs.
- Open Access
- 10 April 2017
- Published by Springer Nature in Nature Nanotechnology
- Vol. 12 (7) , 668-674
Position-dependent and millimetre-range photodetection in phototransistors with micrometre-scale graphene on SiC
The extraordinary optical and electronic properties of graphene make it a promising component of high-performance photodetectors. However, in typical graphene-based photodetectors demonstrated to date, the photoresponse only comes from specific locations near graphene over an area much smaller than the device size. For many optoelectronic device applications, it is desirable to obtain the photoresponse and positional sensitivity over a much larger area. Here, we report the spatial dependence of the photoresponse in backgated graphene field-effect transistors (GFET) on silicon carbide (SiC) substrates by scanning a focused laser beam across the GFET. The GFET shows a nonlocal photoresponse even when the SiC substrate is illuminated at distances greater than 500 µm from the graphene. The photoresponsivity and photocurrent can be varied by more than one order of magnitude depending on the illumination position. Our observations are explained with a numerical model based on charge transport of photoexcited carriers in the substrate.
- 10 April 2017
- Published by Springer Nature in Nature Nanotechnology
- Vol. 12 (7) , 668-674
Open AccessPosition-dependent and millimetre-range photodetection in phototransistors with micrometre-scale graphene on SiC
The extraordinary optical and electronic properties of graphene make it a promising component of high-performance photodetectors. However, in typical graphene-based photodetectors demonstrated to date, the photoresponse only comes from specific locations near graphene over an area much smaller than the device size. For many optoelectronic device applications, it is desirable to obtain the photoresponse and positional sensitivity over a much larger area. Here, we report the spatial dependence of the photoresponse in backgated graphene field-effect transistors (GFET) on silicon carbide (SiC) substrates by scanning a focused laser beam across the GFET. The GFET shows a nonlocal photoresponse even when the SiC substrate is illuminated at distances greater than 500 µm from the graphene. The photoresponsivity and photocurrent can be varied by more than one order of magnitude depending on the illumination position. Our observations are explained with a numerical model based on charge transport of photoexcited carriers in the substrate.
- Open Access
- 1 June 2015
- Published by AIP Publishing in Applied Physics Letters
- Vol. 106 (22) , 223503
Position sensitivity of graphene field effect transistors to X-rays
Device architectures that incorporate graphene to realize detection of electromagnetic radiation typically utilize the direct absorbance of radiation by graphene. This limits their effective area to the size of the graphene and their applicability to lower-energy, less penetrating forms of radiation. In contrast, graphene-based transistor architectures that utilize the field effect as the detection mechanism can be sensitive to interactions of radiation not only with graphene but also with the surrounding substrate. Here, we report the study of the position sensitivity and response of a graphene-based field effect transistor (GFET) to penetrating, well-collimated radiation (micro-beam X-rays), producing ionization in the substrate primarily away from graphene. It is found that responsivity and response speed are strongly dependent on the X-ray beam distance from graphene and the gate voltage applied to the GFET. To develop an understanding of the spatially dependent response, a model is developed that incorporates the volumetric charge generation, transport, and recombination. The model is in good agreement with the observed spatial response characteristics of the GFET and predicts a greater response potential of the GFET to radiation interacting near its surface. The study undertaken provides the necessary insight into the volumetric nature of the GFET response, essential for development of GFET-based detectors for more penetrating forms of ionizing radiation.
- 1 June 2015
- Published by AIP Publishing in Applied Physics Letters
- Vol. 106 (22) , 223503
Open AccessPosition sensitivity of graphene field effect transistors to X-rays
Device architectures that incorporate graphene to realize detection of electromagnetic radiation typically utilize the direct absorbance of radiation by graphene. This limits their effective area to the size of the graphene and their applicability to lower-energy, less penetrating forms of radiation. In contrast, graphene-based transistor architectures that utilize the field effect as the detection mechanism can be sensitive to interactions of radiation not only with graphene but also with the surrounding substrate. Here, we report the study of the position sensitivity and response of a graphene-based field effect transistor (GFET) to penetrating, well-collimated radiation (micro-beam X-rays), producing ionization in the substrate primarily away from graphene. It is found that responsivity and response speed are strongly dependent on the X-ray beam distance from graphene and the gate voltage applied to the GFET. To develop an understanding of the spatially dependent response, a model is developed that incorporates the volumetric charge generation, transport, and recombination. The model is in good agreement with the observed spatial response characteristics of the GFET and predicts a greater response potential of the GFET to radiation interacting near its surface. The study undertaken provides the necessary insight into the volumetric nature of the GFET response, essential for development of GFET-based detectors for more penetrating forms of ionizing radiation.
- 29 July 2013
- Published by AIP Publishing in Applied Physics Letters
- Vol. 103 (5) , 053123
Hysteretic response of chemical vapor deposition graphene field effect transistors on SiC substrates
Graphene field effect transistors (GFETs) fabricated by chemical vapor deposition graphene deposited onto SiC substrates exhibit sensitivity to broadband visible light. The hysteretic nature of this GFET type was studied utilizing a new current-voltage measurement technique in conjunction with current-time measurements. This measurement method accounts for hysteretic changes in graphene response and enables transfer measurements that can be attributed to fixed gate voltages. Graphene hysteresis is shown to be consistent with electrochemical p-type doping, and current-time measurements clearly resolve a hole to electron to hole carrier transition in graphene with a single large change in gate voltage.
- 29 July 2013
- Published by AIP Publishing in Applied Physics Letters
- Vol. 103 (5) , 053123
Hysteretic response of chemical vapor deposition graphene field effect transistors on SiC substrates
Graphene field effect transistors (GFETs) fabricated by chemical vapor deposition graphene deposited onto SiC substrates exhibit sensitivity to broadband visible light. The hysteretic nature of this GFET type was studied utilizing a new current-voltage measurement technique in conjunction with current-time measurements. This measurement method accounts for hysteretic changes in graphene response and enables transfer measurements that can be attributed to fixed gate voltages. Graphene hysteresis is shown to be consistent with electrochemical p-type doping, and current-time measurements clearly resolve a hole to electron to hole carrier transition in graphene with a single large change in gate voltage.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Graphene field effect transistor-based detectors for detection of ionizing radiation
We present the results of our recent efforts to develop novel ionizing radiation sensors based on the nanomaterial graphene. Graphene used in the field effect transistor architecture could be employed to detect the radiation-induced charge carriers produced in undoped semiconductor absorber substrates, even without the need for charge collection. The detection principle is based on the high sensitivity of graphene to ionization-induced local electric field perturbations in the electrically biased substrate. We experimentally demonstrated promising performance of graphene field effect transistors for detection of visible light, X-rays, gamma-rays, and alpha particles. We propose improved detector architectures which could result in a significant improvement of speed necessary for pulsed mode operation.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Graphene field effect transistor-based detectors for detection of ionizing radiation
We present the results of our recent efforts to develop novel ionizing radiation sensors based on the nanomaterial graphene. Graphene used in the field effect transistor architecture could be employed to detect the radiation-induced charge carriers produced in undoped semiconductor absorber substrates, even without the need for charge collection. The detection principle is based on the high sensitivity of graphene to ionization-induced local electric field perturbations in the electrically biased substrate. We experimentally demonstrated promising performance of graphene field effect transistors for detection of visible light, X-rays, gamma-rays, and alpha particles. We propose improved detector architectures which could result in a significant improvement of speed necessary for pulsed mode operation.