ECEdward Cazalas

Edward Cazalas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Edward Cazalas has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of in situ dosimetry for FLASH proton radiotherapy via organic scintillating fibers

    by Codey Olson, Jacob Strong, Adam Paxton, Geoff Nelson, Edward Cazalas

    Objectives: This work presents the design, development, and initial proof-of-concept testing of a dosimetry device intended for FLASH radiotherapy. Methods: The system incorporates organic scintillating fibers coupled to a silicon photomultiplier (SiPM) and an FPGA-based readout, with fiber geometry optimized to minimize perturbations to a clinical proton beam, as confirmed through measurements at the Huntsman Cancer Institute (HCI). Results: Tests using a portable X-ray unit demonstrated a strong correlation between integrated charge and delivered dose (up to ∼35 mrem s−1) and showed that the detector can respond on nanosecond timescales, enabling rapid safety interlock triggering with minimal latency. Conclusion: Preliminary proton irradiations at HCI further indicated that the device can resolve individual beam pulses, a capability valuable for both FLASH research and conventional radiotherapy. Advances in knowledge: These results highlight the need for continued refinement of the experimental setup, readout electronics, and detector performance to fully realize real-time, in situ dose and pulse monitoring.

  • Open Access

    A review of radiation-induced damage to quantum dots

    by Jesse Snow, Alex Gilbreath, Edward Cazalas


  • Open Access

    Radiation Effects on Stepper Motors and Lubricants: A Review

    by Logan Jackson, Victor Boyer, Tanner Rima, Edward Cazalas

    The use of electrical motors and other remote systems are important tools in radiation environments. Certain harsh radiation environments, such as particle accelerators, require the use of remote systems during operation. Stepper motors are one motor, in particular, that have acquired interest in the nuclear field for use in these remote systems. The stepper motor’s precision in rotation and holding is a highly desired quality. In this review, the stepper motor is examined for use in radiation environments. The different mechanical parts are introduced and examined from the broader literature of previous work. We attempt to explain the different radiation destructive mechanisms involved with each part of the stepper motor and how the mechanics are affected. Current and past research is explored, identifying either radiation hard alternatives or thresholds of the materials involved, and a general review of stepper motor radiation effects as available in literature.

  • Retrieval and Characterization of a Plutonium-beryllium Source at the University of Utah

    by Codey Olson, William Bates, Edward Cazalas

    A shielded neutron irradiation facility has been constructed to contain a 74 GBq plutonium-beryllium neutron source at the University of Utah. Due to lack of information and recent use, the GEANT4 Monte Carlo Toolkit was used to perform dose assessments and validation of the designed shield and beam port for storage and operational geometries where the source was to be placed. Borated polyethylene was used as the primary shielding material with a lead-lined beam port to collimate neutrons and reduce gamma rays within the active beam profile. The lead lining was found to reduce the gamma-to-neutron ratio within the profile to 0.259 ± 0.001 and maintain an average neutron flux of 4,633.7 ± 10.2 n cm−2 s−1. The measured dose rate of the source at 30 cm from its constructed storage configuration was found to be 22.3 ± 1.1 μSv h−1 and in good agreement with simulated values. This was also close to the target rate of 20 μSv h−1, the public limit for whole-body dose accumulation, imposed on the design. Measurements of the source during its retrieval and placement into the shield show good agreement with the simulated results and provide a strong validation for the future use of the source in experiments at the University of Utah.


  • Open Access

    Gamma-ray radiation effects in graphene-based transistors with h-BN nanometer film substrates

    by E. Cazalas, M. R. Hogsed, S. Vangala, M. R. Snure, J. W. McClory

    Radiation effects on graphene field effect transistors (GFETs) with hexagonal boron nitride (h-BN) thin film substrates are investigated using 60Co gamma-ray radiation. This study examines the radiation response using many samples with varying h-BN film thicknesses (1.6 and 20 nm thickness) and graphene channel lengths (5 and 10 μm). These samples were exposed to a total ionizing dose of approximately 1 Mrad(Si). I-V measurements were taken at fixed time intervals between irradiations and postirradiation. Dirac point voltage and current are extracted from the I-V measurements, as well as mobility, Dirac voltage hysteresis, and the total number of GFETs that remain properly operational. The results show a decrease in Dirac voltage during irradiation, with a rise of this voltage and permanent drop in Dirac current postirradiation. 1.6 nm h-BN substrate GFETs show an increase in mobility during irradiation, which drops back to preirradiation conditions in postirradiation measurements. Hysteretic changes to the Dirac voltage are the strongest during irradiation for the 20 nm thick h-BN substrate GFETs and after irradiation for the 1.6 nm thick h-BN GFETs. Failure rates were similar for most GFET types during irradiation; however, after irradiation, GFETs with 20 nm h-BN substrates experienced substantially more failures compared to 1.6 nm h-BN substrate GFETs.


  • Open Access

    Position-dependent and millimetre-range photodetection in phototransistors with micrometre-scale graphene on SiC

    by Biddut K. Sarker, Edward Cazalas, Ting-Fung Chung, Isaac Childres, Igor Jovanovic, Yong P. Chen

    The extraordinary optical and electronic properties of graphene make it a promising component of high-performance photodetectors. However, in typical graphene-based photodetectors demonstrated to date, the photoresponse only comes from specific locations near graphene over an area much smaller than the device size. For many optoelectronic device applications, it is desirable to obtain the photoresponse and positional sensitivity over a much larger area. Here, we report the spatial dependence of the photoresponse in backgated graphene field-effect transistors (GFET) on silicon carbide (SiC) substrates by scanning a focused laser beam across the GFET. The GFET shows a nonlocal photoresponse even when the SiC substrate is illuminated at distances greater than 500 µm from the graphene. The photoresponsivity and photocurrent can be varied by more than one order of magnitude depending on the illumination position. Our observations are explained with a numerical model based on charge transport of photoexcited carriers in the substrate.


  • Open Access

    Position sensitivity of graphene field effect transistors to X-rays

    by Edward Cazalas, Biddut K. Sarker, Michael E. Moore, Isaac Childres, Yong P. Chen, Igor Jovanovic

    Device architectures that incorporate graphene to realize detection of electromagnetic radiation typically utilize the direct absorbance of radiation by graphene. This limits their effective area to the size of the graphene and their applicability to lower-energy, less penetrating forms of radiation. In contrast, graphene-based transistor architectures that utilize the field effect as the detection mechanism can be sensitive to interactions of radiation not only with graphene but also with the surrounding substrate. Here, we report the study of the position sensitivity and response of a graphene-based field effect transistor (GFET) to penetrating, well-collimated radiation (micro-beam X-rays), producing ionization in the substrate primarily away from graphene. It is found that responsivity and response speed are strongly dependent on the X-ray beam distance from graphene and the gate voltage applied to the GFET. To develop an understanding of the spatially dependent response, a model is developed that incorporates the volumetric charge generation, transport, and recombination. The model is in good agreement with the observed spatial response characteristics of the GFET and predicts a greater response potential of the GFET to radiation interacting near its surface. The study undertaken provides the necessary insight into the volumetric nature of the GFET response, essential for development of GFET-based detectors for more penetrating forms of ionizing radiation.


  • Hysteretic response of chemical vapor deposition graphene field effect transistors on SiC substrates

    by Edward Cazalas, Isaac Childres, Amanda Majcher, Ting-Fung Chung, Yong P. Chen, Igor Jovanovic

    Graphene field effect transistors (GFETs) fabricated by chemical vapor deposition graphene deposited onto SiC substrates exhibit sensitivity to broadband visible light. The hysteretic nature of this GFET type was studied utilizing a new current-voltage measurement technique in conjunction with current-time measurements. This measurement method accounts for hysteretic changes in graphene response and enables transfer measurements that can be attributed to fixed gate voltages. Graphene hysteresis is shown to be consistent with electrochemical p-type doping, and current-time measurements clearly resolve a hole to electron to hole carrier transition in graphene with a single large change in gate voltage.


  • Graphene field effect transistor-based detectors for detection of ionizing radiation

    by Igor Jovanovic, Edward Cazalas, Isaac Childres, Amol Patil, Ozhan Koybasi, Yong P. Chen

    We present the results of our recent efforts to develop novel ionizing radiation sensors based on the nanomaterial graphene. Graphene used in the field effect transistor architecture could be employed to detect the radiation-induced charge carriers produced in undoped semiconductor absorber substrates, even without the need for charge collection. The detection principle is based on the high sensitivity of graphene to ionization-induced local electric field perturbations in the electrically biased substrate. We experimentally demonstrated promising performance of graphene field effect transistors for detection of visible light, X-rays, gamma-rays, and alpha particles. We propose improved detector architectures which could result in a significant improvement of speed necessary for pulsed mode operation.