Pablo Alejandro Barrionuevo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pablo Alejandro Barrionuevo has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Dingcai Cao
Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago
11 shared publications Dingcai Cao
University of Illinois at Chicago
6 shared publicationsLuis Alberto Issolio
Instituto de Investigacion en Luz, Ambiente y Vision CONICET. Departamento de Luminotecnia, Luz y Vision Universidad Nacional de Tucuman
4 shared publicationsE. Colombo
Univ Nacl Tucuman, CONICET, Inst Invest Luz Ambiente & Vis, Av Independencia 1800,T4002BLR, San Miguel De Tucuman, Tucuman, Argentina
3 shared publications- Isabel Arranz
Departamento de Física Teórica, Atómica y Óptica, Universidad de Valladolid, Valladolid, Spain
3 shared publications J. Jason McAnany
Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Chicago, IL, United States
3 shared publications
Latest Publications
- Open Access
- 14 June 2026
- Published by Consejo Argentino de Oftalmología in Oftalmología Clínica y Experimental
- Vol. 18 (S1) , e1-e43
Resúmenes de investigaciones presentadas en el XV Congreso Nacional de la Asociación de Investigación en Visión y Oftalmología (AIVO)
Llevada a cabo el 7 y 8 de noviembre de 2025 en Buenos Aires
- 14 June 2026
- Published by Consejo Argentino de Oftalmología in Oftalmología Clínica y Experimental
- Vol. 18 (S1) , e1-e43
Open AccessResúmenes de investigaciones presentadas en el XV Congreso Nacional de la Asociación de Investigación en Visión y Oftalmología (AIVO)
Llevada a cabo el 7 y 8 de noviembre de 2025 en Buenos Aires
- Open Access
- 10 March 2026
- Published by MDPI AG in Preprints.org
Development and Validation of a Portable Hyperspectral System Based on a Commercial Camera and a Tunable Filter for Visual Environment Characterization
Hyperspectral imaging integrates spatial and spectral data, crucial for environmental and vision science applications. Existing spectroradiometers lack spatial resolution, and many hyperspectral systems are costly or unsuitable for fieldwork mimicking human vision. Here, we present the development of a portable, relatively low-cost hyperspectral camera based on a tunable filter and a commercial video camera, together with Python-based software capable of generating hyperspectral cubes from the acquired images, as a more accessible and adaptable alternative for specific applications. The proposed method includes assembling the acquisition system and processing raw images, which have been demosaiced, linearized, and labeled with their corresponding spectral band, to generate a hyperspectral cube. Our approach allows radiance retrieval through prior calibration or reflectance estimation using a white reference from a selected region of the hyperspectral cube. Additionally, it enables exporting the hyperspectral cube as a three-dimensional matrix. The developed software facilitates visualization and analysis of hyperspectral data. Validation against a spectroradiometer demonstrated reliable spectral radiance measurements under moderate to high light conditions. This adaptable approach enhances accessibility to hyperspectral imaging for research contexts with limited resources, supporting detailed visual environment characterization outside controlled laboratory settings.
- 10 March 2026
- Published by MDPI AG in Preprints.org
Open AccessDevelopment and Validation of a Portable Hyperspectral System Based on a Commercial Camera and a Tunable Filter for Visual Environment Characterization
Hyperspectral imaging integrates spatial and spectral data, crucial for environmental and vision science applications. Existing spectroradiometers lack spatial resolution, and many hyperspectral systems are costly or unsuitable for fieldwork mimicking human vision. Here, we present the development of a portable, relatively low-cost hyperspectral camera based on a tunable filter and a commercial video camera, together with Python-based software capable of generating hyperspectral cubes from the acquired images, as a more accessible and adaptable alternative for specific applications. The proposed method includes assembling the acquisition system and processing raw images, which have been demosaiced, linearized, and labeled with their corresponding spectral band, to generate a hyperspectral cube. Our approach allows radiance retrieval through prior calibration or reflectance estimation using a white reference from a selected region of the hyperspectral cube. Additionally, it enables exporting the hyperspectral cube as a three-dimensional matrix. The developed software facilitates visualization and analysis of hyperspectral data. Validation against a spectroradiometer demonstrated reliable spectral radiance measurements under moderate to high light conditions. This adaptable approach enhances accessibility to hyperspectral imaging for research contexts with limited resources, supporting detailed visual environment characterization outside controlled laboratory settings.
- Open Access
Melanopsin-mediated signals in natural and human-made environments
Melanopsin-expressing intrinsically photosensitive retinal ganglion cells (ipRGCs) play a critical role in regulating physiological and behavioral responses to light. However, little is known about how melanopsin and ipRGC signals are shaped by the statistical properties of real-world environments. Here, we analyzed statistics of melanopsin, ipRGC codification of extrinsic and intrinsic photoresponses, and luminance using hyperspectral images of natural and human-made scenes under daylight illumination. The statistics were obtained simulating receptive fields from current knowledge about ipRGCs anatomy and physiology. Our findings reveal that human-made environments exhibit significantly higher melanopsin, luminance, and ipRGC excitations compared to natural environments. In natural scenes, luminance contrasts were higher than melanopsin and ipRGC contrasts across most of the range. Melanopsin contrast was largely independent of excitation, and was significantly reduced for larger receptive fields. Differences between ipRGC codification models suggest an interaction between input weighting and environmental structure. These results indicate that modifications of natural regularities by human-made environments could affect ipRGC-driven physiology in everyday life.
Open AccessMelanopsin-mediated signals in natural and human-made environments
Melanopsin-expressing intrinsically photosensitive retinal ganglion cells (ipRGCs) play a critical role in regulating physiological and behavioral responses to light. However, little is known about how melanopsin and ipRGC signals are shaped by the statistical properties of real-world environments. Here, we analyzed statistics of melanopsin, ipRGC codification of extrinsic and intrinsic photoresponses, and luminance using hyperspectral images of natural and human-made scenes under daylight illumination. The statistics were obtained simulating receptive fields from current knowledge about ipRGCs anatomy and physiology. Our findings reveal that human-made environments exhibit significantly higher melanopsin, luminance, and ipRGC excitations compared to natural environments. In natural scenes, luminance contrasts were higher than melanopsin and ipRGC contrasts across most of the range. Melanopsin contrast was largely independent of excitation, and was significantly reduced for larger receptive fields. Differences between ipRGC codification models suggest an interaction between input weighting and environmental structure. These results indicate that modifications of natural regularities by human-made environments could affect ipRGC-driven physiology in everyday life.
- Open Access
- 17 February 2025
- Published by Paideia Studio (publications)
¿Es factible desarrollar tecnología en un centro académico de Argentina?: Un acercamiento desde la percepción de sus integrantes
Technological development (TD) is considered an engine of economic growth of nations. Academic centers with technical capabilities are key players in innovation and TD processes. However, considering a TD policy in an academic center requires the evaluation of multiple factors. One of them is to know the capacity of the center and its perception in this regard. The case of a state academic center in Argentina was analyzed, which arises from a faculty that trains engineers (half of its staff) and maintains a relationship with technology companies. The perception of the members regarding the capacity and involvement with the WP at a personal and institutional level was evaluated using two instruments: 1) an anonymous survey that was disseminated to all the members and 2) interviews with the institution's representatives. It was observed that there is a majority perception that the center develops technology (63%), however, only 7% of the respondents recognize it as their main activity. This self-perception of capacity for the TD is limited by the academic evaluation system, the participation of its members in multiple other activities and the lack of policies that promote its possibility.
- 17 February 2025
- Published by Paideia Studio (publications)
Open Access¿Es factible desarrollar tecnología en un centro académico de Argentina?: Un acercamiento desde la percepción de sus integrantes
Technological development (TD) is considered an engine of economic growth of nations. Academic centers with technical capabilities are key players in innovation and TD processes. However, considering a TD policy in an academic center requires the evaluation of multiple factors. One of them is to know the capacity of the center and its perception in this regard. The case of a state academic center in Argentina was analyzed, which arises from a faculty that trains engineers (half of its staff) and maintains a relationship with technology companies. The perception of the members regarding the capacity and involvement with the WP at a personal and institutional level was evaluated using two instruments: 1) an anonymous survey that was disseminated to all the members and 2) interviews with the institution's representatives. It was observed that there is a majority perception that the center develops technology (63%), however, only 7% of the respondents recognize it as their main activity. This self-perception of capacity for the TD is limited by the academic evaluation system, the participation of its members in multiple other activities and the lack of policies that promote its possibility.
- Open Access
Increased brightness assimilation in rod vision
- Open Access
- 29 September 2024
- Published by MDPI AG in Brain Sciences
- Vol. 14 (10) , 993
Contrast Sensitivity Is Impaired in Suspected Primary Open-Angle Glaucoma Patients
Purpose: To assess spatial contrast sensitivity (CS) in suspected primary open-angle glaucoma (POAG) patients. Methods: CS was measured using sinusoidal gratings of 4 cycles/degree. First, foveal and peripheral CS were assessed in 34 suspected POAG patients and compared with 71 and 28 age-matched healthy individuals for foveal and peripheral conditions, respectively. Second, foveal CS was assessed in 34 early POAG patients age-matched with suspected POAG patients. Analyses were performed considering two age ranges: Under and Over 50 y.o. Correlations were evaluated between CS and clinical parameters. Diagnostic accuracy was also analyzed. Results: Peripheral CS was lower in older suspected POAG patients (23.4 ± 16.1) than the control group (39.1 ± 28.2) (p = 0.040). Foveal CS was reduced in suspected POAG participants (Under 50: 146.8 ± 63.3; p = 0.004. Over 50: 110.5 ± 65.0; p = 0.044) and in early POAG patients (Under 50: 141.2 ± 72.6; p = 0.002. Over 50: 80.2 ± 54.5 p < 0.001), both compared to the control group (Under 50: 213.5 ± 66.2. Over 50: 138.6 ± 71.7). CS was lower in early POAG than in POAG suspected in older patients (p = 0.042). Foveal CS was correlated with age (Early: p = 0.001. Suspect: p = 0.002) and with the cup–disc ratio only in early POAG patients (p < 0.001). Foveal CS had fair (AUC = 0.74) diagnostic accuracy for early POAG patients. Conclusions: CS in suspected POAG patients is lower than in healthy individuals. Our findings evidence the spatial vision loss before the onset of POAG.
- 29 September 2024
- Published by MDPI AG in Brain Sciences
- Vol. 14 (10) , 993
Open AccessContrast Sensitivity Is Impaired in Suspected Primary Open-Angle Glaucoma Patients
Purpose: To assess spatial contrast sensitivity (CS) in suspected primary open-angle glaucoma (POAG) patients. Methods: CS was measured using sinusoidal gratings of 4 cycles/degree. First, foveal and peripheral CS were assessed in 34 suspected POAG patients and compared with 71 and 28 age-matched healthy individuals for foveal and peripheral conditions, respectively. Second, foveal CS was assessed in 34 early POAG patients age-matched with suspected POAG patients. Analyses were performed considering two age ranges: Under and Over 50 y.o. Correlations were evaluated between CS and clinical parameters. Diagnostic accuracy was also analyzed. Results: Peripheral CS was lower in older suspected POAG patients (23.4 ± 16.1) than the control group (39.1 ± 28.2) (p = 0.040). Foveal CS was reduced in suspected POAG participants (Under 50: 146.8 ± 63.3; p = 0.004. Over 50: 110.5 ± 65.0; p = 0.044) and in early POAG patients (Under 50: 141.2 ± 72.6; p = 0.002. Over 50: 80.2 ± 54.5 p < 0.001), both compared to the control group (Under 50: 213.5 ± 66.2. Over 50: 138.6 ± 71.7). CS was lower in early POAG than in POAG suspected in older patients (p = 0.042). Foveal CS was correlated with age (Early: p = 0.001. Suspect: p = 0.002) and with the cup–disc ratio only in early POAG patients (p < 0.001). Foveal CS had fair (AUC = 0.74) diagnostic accuracy for early POAG patients. Conclusions: CS in suspected POAG patients is lower than in healthy individuals. Our findings evidence the spatial vision loss before the onset of POAG.
- Open Access
- 18 April 2024
- Published by Elsevier in Vision Research
- Vol. 219, 108414
Corrigendum to “Are ipRGCs involved in human color vision? Hints from physiology, psychophysics, and natural image statistics” [Vis. Res. 217 (2024) 108378]
- 18 April 2024
- Published by Elsevier in Vision Research
- Vol. 219, 108414
Open AccessCorrigendum to “Are ipRGCs involved in human color vision? Hints from physiology, psychophysics, and natural image statistics” [Vis. Res. 217 (2024) 108378]
- Open Access
CONTRAST SENSITIVITY IS IMPAIRED IN SUSPECTED PRIMARY OPEN-ANGLE GLAUCOMA PATIENTS
Purpose: To assess contrast sensitivity (CS) for detecting visual changes in suspected POAG patients. Methods: CS was measured foveally at photopic conditions and peripherally at mesopic conditions using sinusoidal gratings of 4 cycles/degree. In experiment 1, foveal and peripheral CS were assessed in suspected POAG patients and age-matched healthy control subjects. In experiment 2, foveal CS was assessed in early POAG patients age-matched with suspected POAG group. Analysis was done considering two age ranges (Under and Over 50 years of age). Correlations between CS and clinical parameters were evaluated. Results: Peripheral CS was decreased only for older POAG suspect patients from the control group (Over 50: p = 0.008. Under 50: p = 0.566). Foveal CS was reduced in POAG suspect participants for both age ranges (Over 50: p = 0.028. Under 50: p < 0.001) and in early POAG patients (Under 50: p = 0.001; Over 50: p < 0.001), both compared to the control group. Foveal CS was lower in early POAG compared to POAG suspect for older patients (Over 50: p = 0.019. Under 50: p = 0.824). Foveal CS was correlated with cup-disc ratio in early POAG patients (Early: p < 0.001. Suspect: p = 0.766) and with age in both patient groups (Early: p = 0.001. Suspect: p = 0.002). Conclusion: CS is affected in patients with a high risk of developing POAG and recently diagnosed. Our results suggest that CS could serve as a screening tool, detecting early damage even before structural changes occur.
Open AccessCONTRAST SENSITIVITY IS IMPAIRED IN SUSPECTED PRIMARY OPEN-ANGLE GLAUCOMA PATIENTS
Purpose: To assess contrast sensitivity (CS) for detecting visual changes in suspected POAG patients. Methods: CS was measured foveally at photopic conditions and peripherally at mesopic conditions using sinusoidal gratings of 4 cycles/degree. In experiment 1, foveal and peripheral CS were assessed in suspected POAG patients and age-matched healthy control subjects. In experiment 2, foveal CS was assessed in early POAG patients age-matched with suspected POAG group. Analysis was done considering two age ranges (Under and Over 50 years of age). Correlations between CS and clinical parameters were evaluated. Results: Peripheral CS was decreased only for older POAG suspect patients from the control group (Over 50: p = 0.008. Under 50: p = 0.566). Foveal CS was reduced in POAG suspect participants for both age ranges (Over 50: p = 0.028. Under 50: p < 0.001) and in early POAG patients (Under 50: p = 0.001; Over 50: p < 0.001), both compared to the control group. Foveal CS was lower in early POAG compared to POAG suspect for older patients (Over 50: p = 0.019. Under 50: p = 0.824). Foveal CS was correlated with cup-disc ratio in early POAG patients (Early: p < 0.001. Suspect: p = 0.766) and with age in both patient groups (Early: p = 0.001. Suspect: p = 0.002). Conclusion: CS is affected in patients with a high risk of developing POAG and recently diagnosed. Our results suggest that CS could serve as a screening tool, detecting early damage even before structural changes occur.
- Open Access
- 7 March 2024
- Published by Elsevier in Vision Research
- Vol. 217, 108378
Are ipRGCs involved in human color vision? Hints from physiology, psychophysics, and natural image statistics
- 7 March 2024
- Published by Elsevier in Vision Research
- Vol. 217, 108378
Open AccessAre ipRGCs involved in human color vision? Hints from physiology, psychophysics, and natural image statistics
- Open Access
- 2 April 2023
- Published by Elsevier in Journal of Photochemistry and Photobiology
- Vol. 15
Photoreceptor contributions to the human pupil light reflex
- 2 April 2023
- Published by Elsevier in Journal of Photochemistry and Photobiology
- Vol. 15
Open AccessPhotoreceptor contributions to the human pupil light reflex