RLRuud Adrianus Leijendekkers

Ruud Adrianus Leijendekkers

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ruud Adrianus Leijendekkers has a total of 84 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Heterogeneity of Patients’ Preferences for Bone-Anchored Prostheses After Lower-Extremity Amputation (PREFER-BAP-2)

    by Sarathiel-Kyrillos M. Saleib, Marcel F. Jonker, Michael H.J. Verhofstad, Maria A. Paping, Mark G. Van Vledder, Ruud A. Leijendekkers, Oscar J.F. Van Waes

    Background: Patients with a bone-anchored prosthesis (BAP) previously expressed preferences regarding (i.e., indicated the importance of) 5 treatment attributes: change in quality of life (QoL), short- and long-term complications, implant survival, and out-of-pocket contributions (costs). However, preference heterogeneity is unclear. We aimed to identify latent preference subgroups, quantify attribute importance per subgroup, and describe background characteristics associated with each subgroup. Methods: A discrete choice experiment to reveal preferences for BAP characteristics among 247 patients from The Netherlands was analyzed using a latent class logit model. Subgroups (classes) were interpreted using relative attribute weights and patient characteristics. Results: A model with 3 classes (with 49% [n = 121], 27% [n = 67], and 24% [n = 59] of the patients in Classes 1, 2, and 3, respectively) fit best. Across classes, short-term complications were least important, and patients considered opting out of BAP treatment when outcomes were unfavorable. Within the classes, when BAP was selected, QoL remained a key driver (31% of decision weight in Class 1, 53% in Class 2, and 26% in Class 3). Class 1 weighted QoL and out-of-pocket contributions most; Class 2 prioritized QoL and disregarded short-term complications; Class 3 placed the most weight on long-term complications and was sensitive to out-of-pocket contributions mainly at high cost levels (€20,000 to €25,000) and to osseointegrated implant survival only when survival dropped from 20 to 5 years. Background profiles differed: compared with the other classes, Class 1 (66% male) had a greater proportion of patients with transtibial amputations and longer BAP experience; Class 2 (48% male) included a greater proportion with higher education and income levels and worse pre-treatment mobility, pain, and anxiety; and Class 3 (80% male) had a greater proportion with lower education and income levels, and the highest proportion awaiting surgery. Conclusions: Patient preferences for key aspects of BAP treatment are heterogeneous. We identified 3 distinct subgroups, and a patient’s background characteristics can help estimate membership in a particular subgroup. Patient-reported outcomes should be interpreted in light of these preference differences. Future work should integrate preference assessment into pre-treatment triage to better align counseling and selection with what patients value, ideally using a brief choice-task screening tool; the optimal screening tasks remain to be established. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.

  • Open Access

    Comparisons of (cost-)effectiveness of manual, hybrid, and digital shape capture and shape design techniques for transtibial and transfemoral prosthetic sockets: A scoping review

    by Pien van Gastel, Iris Pieta Jacoba Sterkenburg, Gerwin Smit, Merel van der Stelt, Ruud Leijendekkers

    This scoping review provides an overview of studies comparing the (cost-)effectiveness of shape capture and socket design techniques for transtibial and transfemoral prostheses. The review compares manual, hybrid, and digital methods, identifies the measurement tools used, and assesses their methodological quality. Effectiveness refers to clinical and functional outcomes such as socket fit, comfort, and user function, whereas cost-effectiveness reflects the balance between resource use and these outcomes. Following Preferred Reporting Items for Systematic Reviews and Meta-analysis guidelines, 5 databases (PubMed, Embase, Web of Science, CINAHL, and Cochrane) were systematically searched. Studies involving humans with transtibial or transfemoral prostheses that compared at least 2 of the 3 methods and reported (cost-)effectiveness outcomes were included. Of 556 articles screened, 20 met the inclusion criteria (497 participants). Sixteen studies evaluated transtibial prostheses and 4 transfemoral prostheses. Manual and hybrid methods were compared in 14 studies, and digital and manual methods in 6, whereas none compared hybrid and digital methods. Eighteen studies were rated as low quality, 2 as moderate, and none as high. Effectiveness constructs mainly covered the International Classification of Functioning, Disability and Health domains “Body functions & Body structures” and “Activities and participation,” but many were not clearly defined within this framework. Reported outcomes most often addressed production time, number of socket attempts, and socket fit or comfort. Overall, evidence remains limited and inconsistent, with a clear lack of direct comparisons between digital and hybrid techniques. Tentatively, hybrid and digital approaches may improve efficiency and comfort compared with manual methods, but robust, standardized research is needed to confirm these effects.


  • Open Access

    Continuous volitional control of a bionic leg supports diverse walking patterns in both agonist–antagonist muscle interface and bone-anchored prosthesis users

    by Federica Damonte, Lucas Avanci Gaudio, Jose Gonzalez-Vargas, Guillaume Durandau, Jennifer Ernst, Johan S Rietman, Ruud Leijendekkers, Herman van der Kooij, Massimo Sartori

    Myoelectric control paradigms have the potential to enable continuous volitional control of bionic limbs in various movement conditions. Although individuals with below knee amputations and an agonist–antagonist muscle interface (AMI) were proven to display a greater degree of continuous volitional control in bionic ankle-foot systems with respect to conventional socket-suspended prosthetic users, it remains unclear how myoelectric interfaces could translate to non-AMI prosthetic users with bone-anchored prostheses (BAP). This preliminary study proposes a human–machine interface (HMI) based on a neuromechanical model to enable volitional, continuous myoelectric control of a bionic leg in AMI and BAP users, walking across various speeds and ground inclinations. Differently from state of the art solutions, the proposed HMI is based on a digital twin of the intact leg, synthesizing the user’s phantom limb musculoskeletal function as controlled by muscle activations measured from the residuum. When embedded in a real-time framework, it enabled the participants to achieve volitional modulation of prosthesis peak plantar-dorsiflexion torques timing and amplitude during overground walking at three speeds (between 1.6 and 3.96 km/h), with case studies provided during calf-raises (30, 45, and 60 bpm) and ramp ascent walking (3 and 5% incline). Before prosthesis control tests, the participants underwent a 2-day gait training session. Results showed that all three subjects learned how to alter initial muscle activation patterns so that an average of 87% of peak activation timing fell within target ranges. The proposed neuromechanical modeling technology opens new avenues toward generalizable HMIs for the volitional control of active prostheses beyond set conditions and amputation types.


  • Open Access

    Past, present, and future of bone-anchored prosthesis for individuals with lower limb amputation in The Netherlands

    by David Reetz, Ruud Leijendekkers, Michael Jr Edwards, Jan Paul Frölke


  • Open Access

    A Bionic Foot Controlled by a Synergy-Driven Neuromechanical Model Enables Walking at Various Speeds in Socket-Suspended and Bone-Anchored Prosthesis Users

    by F. Damonte, J. Gonzalez-Vargas, G. Durandau, J. S. Rietman, R. Leijendekkers, H. van der Kooij, M. Sartori

    Human locomotion adapts to different conditions, resulting in changes in gait parameters like speed, stride time, and length. Bionic limbs strive to mimic natural walking patterns, with speed adaptation being a key feature. Research shows that myoelectric bionic legs allow individuals with agonist-antagonist myoneural interface (AMI) amputations to control speed-adaptive walking. However, those with non-AMI amputations show difficulty generating consistent electromyography (EMG) signals. Therefore, we aim to create a human-machine interface that provides speed-adaptive biomimetic behavior without relying on EMGs. Steady-state locomotion can be modeled as the sequential recruitment of muscle groups during the gait cycle. To replicate this motor control, we created a control framework for a bionic foot using a neuromechanical model driven by synthetic muscle activations, replacing EMG recordings. We tested the controller on two individuals with transtibial amputations—one with a socket-suspended prosthesis and the other with a bone-anchored prosthesis. Muscle activation peaks fell within target ranges, leading to peak plantar-flexion torques at 49% of the gait cycle. The averaged model torques aligned with those from inverse dynamics on the intact side (RMSE = 0.52 ± 0.3 (Nm/Kg), r = 0.52 ± 0.4). The results show that the control system effectively modulates joint torques in timing and amplitude for two subjects across three walking speeds (0.55 to 1.1 m/s). Designed for steady-state walking, it can modulate torque during speed transitions. This first investigation aims to prove the feasibility of a personalized biomimetic control framework for bionic limbs without relying on EMGs, supporting walking at various speeds.


  • What Are the Complications, Functional Outcomes, and Health-related Quality of Life of Bone-anchored Prostheses in Transfemoral Amputees? A Comparison of Single- and Two-stage Surgery Over Time

    by David Reetz, Zadakiel-Kyrillos M. Saleib, Esther M. M. Van Lieshout, Michael J. R. Edwards, Michiel H. J. Verhofstad, Mark G. Van Vledder, Oscar J. F. Van Waes, Jan Paul M. Frölke, Ruud A. Leijendekkers

    Background: The insertion of an osseointegration implant providing direct skeletal attachment to an external prosthesis, creating a bone-anchored prosthesis (BAP), is an alternative for patients who have a lower limb socket-suspended prosthesis with socket-related problems. Historically, the osseointegrated implant was inserted in a two-stage procedure for safety reasons; however, the single-stage procedure is being performed and reported on as well. Because there are no studies comparing these two treatment strategies, we conducted this study to investigate complication rates, functional outcomes, and health-related quality of life (HRQoL). Questions/purposes: Did patients who underwent single-stage surgery, compared with two-stage surgery, (1) have a lower frequency of adverse events, (2) have faster rehabilitation times and fewer sessions needed for completing the rehabilitation program, (3) perform better on the Timed Up and Go (TUG) test and 6-Minute Walk Test (6MWT), and (4) have superior HRQoL and prosthesis wearing time? Methods: Between May 2009 and October 2019, Radboud UMC treated 238 patients with BAP, and between September 2017 and December 2019 treated 180 patients, of which 34% (62) had transfemoral amputation and an indication for the standard BAP in a two-stage surgery. Erasmus MC treated 57 patients, of which 51% (29) had transfemoral amputation and an indication for the standard BAP in a single-stage surgery. All patients were considered potentially eligible if they could provide written informed consent. Based on that, all patients were eligible, and of those from Radboud UMC, all were included; a further 3% (2 of 62) were lost at 2-year follow-up because of emigration. For patients from Erasmus MC, a further 10% (3 of 29) were excluded because 7% (2 of 29) did not provide informed consent and 3% (1 of 29) died of nontreatment-related causes. A total of 88 patients remained, with 86 patients remaining at 2-year follow-up. We performed a double-center, retrospective study of patients ages 18 years and older with 2 years of follow-up who were fitted with unilateral osseointegrated implants for a BAP through either single-stage (Erasmus MC, Rotterdam) or two-stage (Radboud UMC, Nijmegen) surgery between December 2014 and November 2019. Both hospitals are Level 1 trauma centers in The Netherlands. Surgeons at Radboud UMC began performing two-stage surgery in 2009 and eventually transitioned to single-stage surgery. Erasmus MC started in 2017 with BAP and exclusively performed single-stage surgery. Patients were eligible for osseointegrated implant surgery if they had demonstrated failure of previous treatments with socket prostheses. The respective clinical teams at each center conducted baseline assessments and postoperative follow-up at 6 months, 1 year, and 2 years as part of routine clinical care, independent of this study. The only differences in patient characteristics were that patients in the two-stage group were younger (mean ± SD 57 ± 13 years versus 64 ± 23 years), and that trauma as a cause of primary amputation occurred relatively more often in the single-stage group (62% [16 of 26]) compared with the two-stage group (45% [28 of 62]). The primary study outcome was the frequency of adverse events per surgical procedure within the fixed 2-year follow-up period. Secondary outcomes included rehabilitation characteristics, functional outcomes (TUG and 6MWT scores), and patient-reported outcomes (HRQoL and prosthesis wearing time). Independent t-tests, chi-square tests, Wilcoxon signed-rank tests, and Mann-Whitney U tests were used to assess differences between and within the two cohorts and study outcomes, with multiple testing corrections applied. Results: A total of six infectious events were reported in 19% (5 of 26) of patients in the single-stage group compared with 22 events in 31% (19 of 62) of patients in the two-stage group. However, patients in the single-stage group experienced more major infection events. The frequency of surgical site infections was 6% (4 of 62) in the two-stage group versus 8% (2 of 26) in the single-stage group. Infections between Stage 1 and Stage 2 occurred in 27% (17 of 62) of patients in the two-stage group. There were no differences in rehabilitation duration (single-stage 15 ± 3 weeks versus two-stage 17 ± 16 weeks, mean difference 2 weeks [95% confidence interval (95% CI) -8 to 4]; p = 0.52); however, patients in the single-stage group had more sessions (22 ± 2 versus 18 ± 9 sessions, mean difference 4 [95% CI 1 to 7]; p = 0.02). Preoperatively, the single-stage group had worse median (IQR) TUG scores (12.8 seconds [11.0 to 16.8]) compared with the two-stage group (10.1 seconds [7.8 to 13.4], mean difference -3 [95% CI -7 to 1]; p = 0.007). Similarly, patients in the single-stage group had worse median (IQR) preoperative 6MWT scores (239 meters [160 to 290]) compared with the two-stage group (290 meters [220 to 367], mean difference 58 [95% CI 8 to 106]; p = 0.007). The TUG test showed greater median changes from baseline to 1-year and baseline to 2-year follow-up in the single-stage group (-3 versus -0.7; p = 0.003 and -3.5 versus -0.8; p < 0.001, respectively). Results were similar for the 6MWT (89 versus 29; p < 0.003 and 132 versus 38; p < 0.001, respectively). The median (IQR) Q-TFA global score was higher in the single-stage group at 2-year follow-up (75 [63 to 83]) compared with the two-stage group (67 [50 to 75], mean difference -8 [95% CI -18 to 2]; p < 0.001). All functional outcomes, except the TUG score at 6 months in the two-stage group, improved compared to baseline. Median changes of TUG and 6MWT scores between baseline and 1- and 2-year follow-up were better in the single-stage group. Conclusion: The single-stage BAP procedure appears to offer possible benefits in terms of the frequency of minor adverse events, no need for second surgery, as well as possible...


  • Novel gait phases recognition framework leveraging the temporal structure of the myoelectric activity

    by Rami Mobarak, Alessandro Mengarelli, Rami N Khushaba, Ali H Al-Timemy, Erik C Prinsen, Federica Verdini, Ruud A Leijendekkers, Sandro Fioretti, Laura Burattini, Andrea Tigrini

    Objective. Reliable control of lower limb prostheses during gait using surface electromyography requires robust decoding of myoelectric signals to ensure safety and efficiency. Conventional myoelectric pattern recognition (PR) methods, which classify features extracted from each window, often yield inaccurate and unstable output, limiting their practical use. Approach. To deal with these issues, two novel temporal myoelectric-based gait phase recognition frameworks are presented. Temporal activation profile (TAP) considers a sequence of features extracted from consecutive windows, and dual activation shots (DAS) using features extracted from the current and a specific preceding window. These methods were tested on (1) publicly available SIAT-LLMD dataset of 40 healthy subjects under different locomotion conditions, and (2) two subjects with transfemoral amputation during normal walking. Main results. TAP and DAS significantly outperformed conventional PR methods, achieving accuracies of 88.50% and 87.97%, respectively, in healthy subjects during normal walking. TAP achieved optimal performance using features extracted from consecutive windows spanning 240 ms in the past, whereas DAS performed best when leveraging features from the current window combined with those from a window 160 ms prior. No significant differences were observed between TAP and DAS under optimal conditions. Both approaches effectively enhanced gait phase recognition performance when applied to transfemoral amputee gait data. The TAP framework achieved the highest performance, surpassing 87.80% accuracy with extended temporal context requirement, and outperforming the DAS approach (82.32%) under pathological conditions. Significance. Both TAP and DAS are robust solutions for gait phase recognition as they stabilize the decision output and reduce classification errors. DAS is more practically feasible due to lower temporal and computational demands, while TAP is more effective in the case of altered neuromuscular activation patterns. The findings of this paper highlight the potential of integrating these methods into real-time prosthetic controllers, ensuring safe and reliable use for patients.


  • Open Access

    How To Improve Patient Selection in Individuals With Lower Extremity Amputation Using a Bone-anchored Prosthesis

    by Charlotte Msc van Vliet-Bockting, Robin Atallah, Jan Paul M. Frölke, Ruud A. Leijendekkers

    Background: Many patients with a lower limb socket-suspended prothesis experience socket-related problems, such as pain, chronic skin conditions, and mechanical problems, and as a result, health-related quality of life (HRQoL) is often negatively affected. A bone-anchored prosthesis can overcome these problems and improve HRQoL, but these prostheses have potential downsides as well. A valid and reliable tool to assess potential candidates for surgery concerning a favorable risk-benefit ratio between potential complications related to bone-anchored prostheses and improvements in HRQoL is not available yet. Having this information may inform treating physicians and patients when deciding whether to pursue bone-anchored prostheses. Questions/purpose: In this study, we asked: (1) What is the difference in HRQoL at 6, 12, and 24 months among patients who underwent lower limb bone-anchored prosthesis treatment after using a socket-suspended prosthesis preoperatively? (2) What factors are associated with change in HRQoL 24 months after lower limb bone-anchored prosthesis treatment? (3) Which complications occurred within 24 months after lower limb bone-anchored prosthesis treatment? (4) What factors are associated with minor to severe complications within 24 months after lower limb bone-anchored prosthesis treatment? Methods: A total of 206 patients who underwent lower limb bone-anchored prosthesis treatment (femoral or tibial) at the Radboud University Medical Center between May 2014 and September 2020 were included in this study. Of those, 8% (17 of 206) were lost to follow-up at 24 months without meeting a study endpoint (not attending the clinic unrelated to the bone-anchored prosthesis, re-amputation), and another < 1% (1 of 206) died prior to 24 months, leaving 92% (189 of 206) of the original group who had a follow-up time of at least 24 months. The mean ± SD age was 54.3 ± 12.7 years, and 72% were men. Amputation levels included 64% (139 of 218) transfemoral amputation, 3% (7 of 218) knee exarticulation, 32% (70 of 218) transtibial amputation, 0.5% (1 of 218) foot amputation, and 0.5% (1 of 218) osseointegration implant after primary amputation. Causes of amputation included 52% (108 of 206) trauma, 8% (17 of 206) oncology, 19% (38 of 206) dysvascular, 12% (25 of 206) infection, 1% (2 of 206) congenital, and 8% (16 of 206) other. Primary outcomes were generic HRQoL (Short-Form 36 health survey mental component summary [MCS] and physical component summary [PCS] scores), disease-specific HRQoL (Questionnaire for Persons with a Transfemoral Amputation global score), and complication occurrence (infection, implant complications such as loosening or breakage, stoma-related problems, periprosthetic fracture, and death). Multivariable multiple regression was used to develop association models. These models demonstrated which group of characteristics were associated with change in HRQoL at 24 months of follow-up and occurrence of complications within 24 months of follow-up. Assessments were carried out at baseline (preoperative while using a socket-suspended prosthesis) and after 6, 12, and 24 months of bone-anchored prosthesis use. Results: Generic HRQoL PCS score improved 25% (β 9 [95% confidence interval (CI) 7 to 11]) at 6 months and maintained that improvement at the 12-month (β 9 [95% CI 7 to 11]) and 24-month (β 8 [95% CI 7 to 10]) follow-up visit compared with baseline (p < 0.001). The generic HRQoL MCS score did not change compared with baseline. Disease-specific HRQoL improved 77% (β 30 [95% CI 25 to 34]), 85% (β 33 [95% CI 28 to 37]), and 72% (β 28 [95% CI 24 to 33]) at 6-month, 12-month, and 24-month follow-up, respectively, compared with baseline (p < 0.001). Patients with the following group of characteristics were more likely to experience a better physical generic HRQoL at 24 months of follow-up: younger patients with a lower physical generic HRQoL, and a traumatic cause of amputation combined with a lower activity level. Patients with the following group of characteristics were more likely to experience a better disease-specific HRQoL at 24 months of follow-up: dysvascular cause of amputation, lower prosthetic comfort combined with a lower activity level, and lower prosthetic comfort combined with a lower or higher activity level. In addition, patients with an average mobility level were more likely to experience less improvement in disease-specific HRQoL at 24 months of follow-up. Infections were the most common complications in the total cohort (116 events in 206 patients), of which the majority consisted of soft tissue infections (98% [114 of 116]). Bone infection did not occur. Septic implant loosening occurred in 1% (2 of 214) of total implants (3% [2 of 66] of tibial implants), both treated with transfemoral amputation. Younger and higher functioning patients had the lowest risk of minor complications within 24 months of follow-up. Women, older patients, patients with a lower activity level, and older patients with more time since amputation had the highest risk of minor complications within 24 months of follow-up. Patients with a higher disease-specific HRQoL had the highest risk of moderate or severe complications within 24 months of follow-up. Conclusion: In agreement with earlier research, this study confirmed that generic HRQoL and disease-specific HRQoL improved after bone-anchored prosthesis use. Additionally, this study confirmed that bone-anchored prosthesis has a relatively low likelihood of severe complications but with a high occurrence of minor complications. These were often successfully treated with nonsurgical interventions. Patients who have a favorable risk-benefit ratio between improvements in HRQoL and potential treatment-related complications are most eligible for a bone-anchored prosthesis. These findings may be helpful to patients and treating physicians to aid in patient selection and to inform...


  • Open Access

    The MyFlex-ζ Foot: A Variable Stiffness ESR Ankle-Foot Prosthesis

    by Johnnidel Tabucol, Vera G. M. Kooiman, Marco Leopaldi, Ruud Leijendekkers, Giacomo Selleri, Marcello Mellini, Nico Verdonschot, Magnús Oddsson, Raffaella Carloni, Andrea Zucchelli, et al.

    Most commercially available foot prostheses are passive ESR feet, which store and release energy to reduce metabolic costs and improve comfort but cannot adjust to varying walking conditions. In contrast, bionic feet adapt to different tasks but are hindered by high weight, power consumption, and cost. This paper presents MyFlex-ζ, an ESR foot with a variable stiffness system, as a compromise between these two categories. MyFlex-ζ adjusts stiffness by varying the sagittal-plane distance between two key points, altering force interactions within the prosthesis and affecting overall stiffness. Clinical tests with three transfemoral amputees evaluated stiffness variation across two sessions: the first subjective, where participants assessed stiffness settings during different tasks, and the second biomechanical, measuring performance parameters. Two participants selected different stiffness settings for various tasks, while the third, with limited perception of stiffness changes, showed less distinction in outcomes. Greater sagittal-plane rotation and higher energy absorption were observed in most tasks with more compliant settings, although one participant’s results were limited due to selecting close stiffness settings. Overall, these findings suggest MyFlex-ζ offers adaptability and performance improvements over traditional ESR feet. With further actuation and control system development, MyFlex-ζ could mark significant progress in prosthesis technology.


  • Press-Fit Bone-Anchored Prosthesis for Patients with Short Transfemoral Amputation

    by Jan Paul Frölke, Robin Atallah, Ruud Leijendekkers

    Background: This video article describes the use of a bone-anchored prosthesis in patients with high above-the-knee amputations resulting in short residual limbs, most typically from trauma, cancer, infections, or dysvascular disease. The use of a socket prosthesis is usually unsuccessful in patients with a high transfemoral amputation because such prostheses have an unstable connection and often require additional waist belts for better attachment to the short residual limb. In most cases, a bone-anchored prosthesis results in substantial improvements in wear time, mobility, and quality of life in these patients. These patients may also be excellent candidates for early osseointegration implant surgery, given the knowledge that socket prostheses are rarely successful. Description: This procedure is preferably performed in a single stage. After the surgical procedure, most patients stay 1 or 2 nights in the hospital, depending on the magnitude of the surgery (e.g., bilateral implantation of an osseointegration implant) and their comorbidities. Procedure steps include (1) preoperative implant planning, (2) patient positioning and setup, (3) soft-tissue correction (optional) and exposure of residual bone, (4) revision osteotomy with guided shortening, (5) preparation of the medullary canal and perpendicular cutoff plane, (6) marking of the lag screw with a custom-made aiming device and dummy prosthesis, (7) insertion of the intramedullary component with optional bone augmentation, (8) insertion of the lag screw, (9) soft-tissue contouring and closure, and (10) stoma creation and dual cone assembly. Alternatives: Simultaneous major leg amputation and implantation of an osseointegration prosthesis is not advocated as treatment. First, a rehabilitation program with a socket-suspended prosthesis should be trialed before a patient can apply for a bone-anchored prosthesis. After rehabilitation, satisfaction with a socket prosthesis may be adequate, making a bone-anchored prosthesis unnecessary; however, patients with very short residual limbs and/or irregular soft-tissue conditions may be candidates for early implantation of a bone-anchored prosthesis. Contraindications for osseointegration implant surgery are severe diabetes (with complications), severe bone deformity, immature bone, bone diseases (chronic infection or metastasis), current chemotherapy, severe vascular diseases, pain without a clear cause, body mass index of >30 kg/m2, and smoking. Rationale: About half of patients with a major lower-limb amputation who use an artificial leg are able to function acceptably well with use of a socket-suspended prosthesis; however, in cases with a high transfemoral amputation level, severe limitations may be expected, resulting in reduced prosthesis use, mobility, and quality of life. In these cases, energy transfer from limb to prosthesis is poor because of the so-called pseudojoint, which is the soft-tissue interface, and gross mechanical malalignment is common. These issues lead to complications related to skin irritation and poor socket fit, resulting in decreased overall satisfaction and confidence in mobility. An osseointegration implant creates a direct skeletal connection between the residual limb and artificial leg, in which energy transfer is optimal and mechanical alignment is radically improved. Expected Outcomes: We performed a prospective study with a 1-year follow-up 1 . A total of 16 patients with a short residual limb following transfemoral amputation received a gamma-type osseointegration implant with additional lag screw fixation toward the femoral neck. Most patients were male, had a traumatic amputation, and underwent a 2-stage surgery. Prosthesis wear time and patient health-related quality of life were measured with use of the Questionnaire for Persons with a Transfemoral Amputation (QTFA) prosthetic use score and global score, respectively. Both measures improved significantly from baseline to 1-year follow-up. The global score is not applicable for patients who do not use a prosthesis. For the 8 patients (i.e., 50% of the cohort) who did not use a prosthesis at baseline, the third question of the global score (G3 Q3) was utilized instead. This question asks, “How would you summarize your overall situation as an amputee?” As measured with this question, these patients also showed a substantial improvement in quality of life from baseline to 1-year follow-up. Adverse events that can occur following this surgical procedure include infection of the soft tissues and/or bone, periprosthetic fracture, implant breakage, aseptic loosening, and redundancy of soft tissues. In our study, only soft-tissue infections occurred. All superficial soft-tissue infections were successfully treated with use of oral antibiotics. One patient with a deep soft-tissue infection required surgery for abscess drainage. One patient required additional surgery to correct redundancy of soft tissues. Dual-cone adaptor breakage occurred twice; both cases were successfully treated in an outpatient clinic setting. We concluded that the short-term results of this treatment were acceptable. Mid-term follow-up results are currently being collected. Important Tips: Preoperative implant planning should be guided by surgical instructions with a custom-made implant design, with the aim of performing the procedure in a single stage. The use of a traction table may be beneficial Liberally resect soft-tissue redundancy. Utilize water-cooled power sawing. Utilize fluoroscopy to guide drilling. The use of radiographic markers can help guide exact lag screw positioning. In case of little resistance during insertion of the intramedullary component, utilize bone morphogenetic protein-2 (BMP-2; Inductos), bone struts, and/or bone-impaction grafting Utilize a lag screw to increase stability Do not close muscle fascia over the implant. Perform a 2-stage procedure only in cases with bone reconstructions, with the stages undertaken at a 10 to 12-week interval. Perform regular postoperative assessment according to your institutional follow-up schedule. Acronyms and Abbreviations: BAP = bone-anchored prosthesis OI = osseointegration implant OFI-Y = custom-made press-fit titanium bone-anchored femur implant (BADAL X; OTN Implants) FL = femur length OFI-C = standard press-fit titanium bone-anchored implant (BADAL-X; OTN Implants) CT = computed tomography DCA = dual-cone adapter K-wire = Kirschner wire