Gregory Hoy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Gregory Hoy has a total of 232 co-authors. Here are the top co-authors by number of shared publications:
- Sarah Warby
Melbourne Shoulder Group, Prahran, Victoria, Australia
9 shared publications - Andrew McBride
Menzies Research Institute Tasmania, University of Tasmania, Hobart, Australia
6 shared publications Shane Barwood
6 shared publicationsLyn Watson
Melbourne Shoulder Group, 305 High Street Prahran, Melbourne, VIC, 3181, Australia
5 shared publications- Paul F. Soeding
Department of Anaesthesia and Pain Medicine, Royal Melbourne Hospital, Melbourne, Australia
5 shared publications - Richard S. Page
Department of Orthopaedic Surgery Barwon Health Geelong Victoria Australia
5 shared publications
Latest Publications
- Open Access
- 13 May 2026
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 108 (20) , 1630-1637
PyroTITAN Pyrocarbon Shoulder Hemiarthroplasty
Background: Pyrocarbon hemiarthroplasty (HA) is a recent option for younger patients with end-stage glenohumeral joint (GHJ) arthritis. Early results are promising but limited by study bias. The aim of this study was to evaluate medium-term clinical and radiographic outcomes following PyroTITAN pyrocarbon HA. Methods: One hundred and nineteen shoulders with GHJ arthritis in 115 patients (mean age, 56.5 years; 92 shoulders were in male patients) underwent PyroTITAN pyrocarbon HA. Primary patient-reported outcome measures (PROMs) included the Western Ontario Osteoarthritis of the Shoulder Index and American Shoulder and Elbow Surgeons score. Clinicians assessed shoulder range of motion and abduction strength. PROMs and clinician evaluations were recorded preoperatively and at 6, 12, and 24 months and 5 years postoperatively. Postoperative complications were recorded, and radiographs were evaluated for glenoid erosion. Implant survival was calculated over the 5-year follow-up period. Data were analyzed on an intention-to-treat basis using linear mixed models for continuous data and Friedman analysis of variance for ordinal data. Kaplan-Meier analysis assessed revision-free survival. Significance was set at p < 0.05. Results: There was significant improvement in all PROMs and ranges of motion at 6, 12, and 24 months and 5 years postoperatively. Abduction strength was significantly improved at 24 months. Seven complications (5.9%) were recorded: ongoing pain (n = 2), stiffness (n = 2), pain and stiffness (n = 2), and implant fracture (n = 1). There were 3 revisions (2.5%) and thus a 97.5% five-year survival rate. Glenoid erosion increased slightly but not significantly over time. Conclusions: The findings in our patient series support the PyroTITAN HA implant as a viable option for GHJ arthritis across a broad age range, including younger patients. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
- 13 May 2026
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 108 (20) , 1630-1637
Open AccessPyroTITAN Pyrocarbon Shoulder Hemiarthroplasty
Background: Pyrocarbon hemiarthroplasty (HA) is a recent option for younger patients with end-stage glenohumeral joint (GHJ) arthritis. Early results are promising but limited by study bias. The aim of this study was to evaluate medium-term clinical and radiographic outcomes following PyroTITAN pyrocarbon HA. Methods: One hundred and nineteen shoulders with GHJ arthritis in 115 patients (mean age, 56.5 years; 92 shoulders were in male patients) underwent PyroTITAN pyrocarbon HA. Primary patient-reported outcome measures (PROMs) included the Western Ontario Osteoarthritis of the Shoulder Index and American Shoulder and Elbow Surgeons score. Clinicians assessed shoulder range of motion and abduction strength. PROMs and clinician evaluations were recorded preoperatively and at 6, 12, and 24 months and 5 years postoperatively. Postoperative complications were recorded, and radiographs were evaluated for glenoid erosion. Implant survival was calculated over the 5-year follow-up period. Data were analyzed on an intention-to-treat basis using linear mixed models for continuous data and Friedman analysis of variance for ordinal data. Kaplan-Meier analysis assessed revision-free survival. Significance was set at p < 0.05. Results: There was significant improvement in all PROMs and ranges of motion at 6, 12, and 24 months and 5 years postoperatively. Abduction strength was significantly improved at 24 months. Seven complications (5.9%) were recorded: ongoing pain (n = 2), stiffness (n = 2), pain and stiffness (n = 2), and implant fracture (n = 1). There were 3 revisions (2.5%) and thus a 97.5% five-year survival rate. Glenoid erosion increased slightly but not significantly over time. Conclusions: The findings in our patient series support the PyroTITAN HA implant as a viable option for GHJ arthritis across a broad age range, including younger patients. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
- 13 November 2025
- Published by Elsevier in Seminars in Arthroplasty: JSES
- Vol. 36 (1) , 151511
Computed tomography density of the acromion prior to reverse total shoulder arthroplasty
- 13 November 2025
- Published by Elsevier in Seminars in Arthroplasty: JSES
- Vol. 36 (1) , 151511
Computed tomography density of the acromion prior to reverse total shoulder arthroplasty
- Open Access
- 30 October 2025
- Published by Elsevier in Journal of ISAKOS
- Vol. 15, 101015
Posterior capsulolabral reconstruction results in good clinical and return to sport outcomes in tennis players with microtraumatic posterior shoulder instability
- 30 October 2025
- Published by Elsevier in Journal of ISAKOS
- Vol. 15, 101015
Open AccessPosterior capsulolabral reconstruction results in good clinical and return to sport outcomes in tennis players with microtraumatic posterior shoulder instability
- 23 October 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (5) , 1209-1218
Outcomes of pyrolytic carbon humeral resurfacing hemiarthroplasty compared to best-in-class total shoulder arthroplasty in young patients with osteoarthritis: analysis from the Australian Orthopaedic Association National Joint Replacement Registry
- 23 October 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (5) , 1209-1218
Outcomes of pyrolytic carbon humeral resurfacing hemiarthroplasty compared to best-in-class total shoulder arthroplasty in young patients with osteoarthritis: analysis from the Australian Orthopaedic Association National Joint Replacement Registry
- 3 September 2025
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 53 (12) , 2963-2972
Correcting Excessive Glenoid Retroversion in Combination With Posterior Glenoid Bone Grafting Leads to Improved Glenohumeral Contact Pressures in a Cadaveric Posterior Instability Model
Background: The extent to which excessive glenoid retroversion leads to increased glenohumeral contact pressures and whether these increases can be mitigated surgically is unknown. Purpose: To evaluate the effect of excessive glenoid retroversion and posterior iliac crest bone grafting (ICBG) with or without glenoid osteotomy on glenohumeral contact patterns. Study Design: Controlled laboratory study. Methods: Six fresh-frozen shoulders had a posterior open-wedge glenoid osteotomy allowing glenoid retroversion to be set at 0°, 10°, and 20°. Four conditions were simulated consecutively on the same specimen at each retroversion angle: intact glenohumeral joint, posterior Bankart lesion, 20% posterior glenoid deficiency, and posterior ICBG (at 20° of retroversion; corrected to 10° and 0° of retroversion). The contact pattern for each specimen was evaluated in the jerk position (60° of glenohumeral anteflexion, 60° of internal rotation) by measuring mean and peak contact pressures (megapascals), peak contact pressure distance (millimeters), and mean contact area (square millimeters). Results: In the intact condition, retroversion of 20° resulted in a significant decrease in contact area but did not significantly affect contact pressure. Creating a posterior Bankart lesion and/or posterior glenoid deficiency showed a significant increase in mean and peak contact pressure at all 3 retroversion angles ( P < .05). Correcting glenoid retroversion to 0° in combination with ICBG resulted in comparable contact area and mean and peak contact pressure of the intact condition ( P > .05). At 10° and 20° of glenoid retroversion, ICBG resulted in significantly higher peak and mean contact pressure (mean not significantly different at 10°) and significantly lower contact area as compared with the intact condition ( P < .05). Conclusion: Glenohumeral contact patterns highly depend on the amount of glenoid retroversion and posterior labral and/or bony glenoid integrity. Only the combination of ICBG and glenoid osteotomy to correct glenoid retroversion to 0° resulted in glenohumeral contact patterns comparable to the native condition with 0° of retroversion. Clinical Relevance: The combined effect of posterior glenoid bone grafting and correcting excessive glenoid retroversion (20°) may correct abnormal glenohumeral contact patterns.
- 3 September 2025
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 53 (12) , 2963-2972
Correcting Excessive Glenoid Retroversion in Combination With Posterior Glenoid Bone Grafting Leads to Improved Glenohumeral Contact Pressures in a Cadaveric Posterior Instability Model
Background: The extent to which excessive glenoid retroversion leads to increased glenohumeral contact pressures and whether these increases can be mitigated surgically is unknown. Purpose: To evaluate the effect of excessive glenoid retroversion and posterior iliac crest bone grafting (ICBG) with or without glenoid osteotomy on glenohumeral contact patterns. Study Design: Controlled laboratory study. Methods: Six fresh-frozen shoulders had a posterior open-wedge glenoid osteotomy allowing glenoid retroversion to be set at 0°, 10°, and 20°. Four conditions were simulated consecutively on the same specimen at each retroversion angle: intact glenohumeral joint, posterior Bankart lesion, 20% posterior glenoid deficiency, and posterior ICBG (at 20° of retroversion; corrected to 10° and 0° of retroversion). The contact pattern for each specimen was evaluated in the jerk position (60° of glenohumeral anteflexion, 60° of internal rotation) by measuring mean and peak contact pressures (megapascals), peak contact pressure distance (millimeters), and mean contact area (square millimeters). Results: In the intact condition, retroversion of 20° resulted in a significant decrease in contact area but did not significantly affect contact pressure. Creating a posterior Bankart lesion and/or posterior glenoid deficiency showed a significant increase in mean and peak contact pressure at all 3 retroversion angles ( P < .05). Correcting glenoid retroversion to 0° in combination with ICBG resulted in comparable contact area and mean and peak contact pressure of the intact condition ( P > .05). At 10° and 20° of glenoid retroversion, ICBG resulted in significantly higher peak and mean contact pressure (mean not significantly different at 10°) and significantly lower contact area as compared with the intact condition ( P < .05). Conclusion: Glenohumeral contact patterns highly depend on the amount of glenoid retroversion and posterior labral and/or bony glenoid integrity. Only the combination of ICBG and glenoid osteotomy to correct glenoid retroversion to 0° resulted in glenohumeral contact patterns comparable to the native condition with 0° of retroversion. Clinical Relevance: The combined effect of posterior glenoid bone grafting and correcting excessive glenoid retroversion (20°) may correct abnormal glenohumeral contact patterns.
- 1 May 2025
- Published by Springer Nature
- p. 293-298
The Failed Posterior Shoulder Stabilization
- Open Access
- 4 October 2024
- Published by Elsevier in JSES International
- Vol. 9 (1) , 46-55
The efficacy of conservative management of micro-traumatic posterior shoulder instability
- 4 October 2024
- Published by Elsevier in JSES International
- Vol. 9 (1) , 46-55
Open AccessThe efficacy of conservative management of micro-traumatic posterior shoulder instability
- Open Access
- 23 September 2024
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 12 (9)
Anconeus Exertional Compartment Syndrome and Posterolateral Rotatory Elbow Instability: A Clinical Association and Rare Cause of Elbow Pain
Background: Anconeus compartment syndrome is a rarely reported compartment syndrome in the anconeus muscle compartment of the forearm. It has anatomic and pathophysiological associations with posterolateral rotatory instability (PLRI) of the elbow. Purpose: To present the history, management, and outcomes of 4 patients with anconeus compartment syndrome. Secondary aims were to (1) establish normative anconeus pressures and (2) measure the volume of this compartment with and without PLRI in cadavers. Study Design: Case series; Level of evidence, 4. Methods: Four patients with clinical signs of anconeus compartment syndrome (2 gymnasts, 1 swimmer, and 1 footballer/weightlifter) were identified over a 3-year period (2015-2017 inclusive). Patient history, sporting activity, physical examination, anconeus compartment pressures, and treatment outcomes were recorded. Manometry of the anconeus compartment in 2 healthy male controls was performed to establish normative compartment pressures. Anconeus volumetric anatomy and the effect of creating PLRI on compartment volume was investigated in 4 cadaveric elbows. Results: All 4 patients had microtraumatic PLRI, and 2 patients had anconeus hypertrophy. Anconeus compartment pressures at rest and at 2-minutes postexercise were median 28.0 and 67.5 mm Hg, respectively, in the patients and mean 16.5 and 18 mm Hg, respectively, in the controls. Simultaneous fasciotomy and PLRI reconstructive procedures were performed in 2 patients, with outcomes showing full return to competition. Fasciotomy alone was performed in 2 patients to allow return to competition, with both requiring later reconstruction to address PLRI. Cadaver dissection revealed that the anconeus compartment was extremely small and that creation of PLRI reduced the direct volume of the compartment and increased the distance between the anconeus origin and insertion. Conclusion: Our case series demonstrated that anconeus compartment syndrome can occur in upper limb-dominant athletes in the presence of PLRI and anconeus hypertrophy. Pain is relieved by fasciotomy, but definitive treatment of the underlying instability prevents further symptomatology.
- 23 September 2024
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 12 (9)
Open AccessAnconeus Exertional Compartment Syndrome and Posterolateral Rotatory Elbow Instability: A Clinical Association and Rare Cause of Elbow Pain
Background: Anconeus compartment syndrome is a rarely reported compartment syndrome in the anconeus muscle compartment of the forearm. It has anatomic and pathophysiological associations with posterolateral rotatory instability (PLRI) of the elbow. Purpose: To present the history, management, and outcomes of 4 patients with anconeus compartment syndrome. Secondary aims were to (1) establish normative anconeus pressures and (2) measure the volume of this compartment with and without PLRI in cadavers. Study Design: Case series; Level of evidence, 4. Methods: Four patients with clinical signs of anconeus compartment syndrome (2 gymnasts, 1 swimmer, and 1 footballer/weightlifter) were identified over a 3-year period (2015-2017 inclusive). Patient history, sporting activity, physical examination, anconeus compartment pressures, and treatment outcomes were recorded. Manometry of the anconeus compartment in 2 healthy male controls was performed to establish normative compartment pressures. Anconeus volumetric anatomy and the effect of creating PLRI on compartment volume was investigated in 4 cadaveric elbows. Results: All 4 patients had microtraumatic PLRI, and 2 patients had anconeus hypertrophy. Anconeus compartment pressures at rest and at 2-minutes postexercise were median 28.0 and 67.5 mm Hg, respectively, in the patients and mean 16.5 and 18 mm Hg, respectively, in the controls. Simultaneous fasciotomy and PLRI reconstructive procedures were performed in 2 patients, with outcomes showing full return to competition. Fasciotomy alone was performed in 2 patients to allow return to competition, with both requiring later reconstruction to address PLRI. Cadaver dissection revealed that the anconeus compartment was extremely small and that creation of PLRI reduced the direct volume of the compartment and increased the distance between the anconeus origin and insertion. Conclusion: Our case series demonstrated that anconeus compartment syndrome can occur in upper limb-dominant athletes in the presence of PLRI and anconeus hypertrophy. Pain is relieved by fasciotomy, but definitive treatment of the underlying instability prevents further symptomatology.
- 9 September 2024
- Published by Wiley in Journal of Medical Imaging and Radiation Oncology
- Vol. 68 (6) , 673-679
Reliable technique for acromion density assessment on CT
Introduction: Acromial stress fracture (ASF) is an uncommon but acknowledged complication of reverse total shoulder arthroplasty (RTSA). There is no standardised method to directly measure the bone mineral density of the acromion to allow a detailed analysis of the potential mechanism of ASF. The aim is to establish a reliable and reproducible technique for measurement of acromial density on computer tomography (CT).Methods: A retrospective review on CT scans obtained for three groups of patients: those planned for RTSA (n = 26); age and gender‐matched non‐operative (n = 26); and young non‐operative patients (n = 28) were performed. Standardised axial images of 1 mm thickness at 1 mm increments were created following horizontal straightening on the coronal and sagittal views. To assess inter‐rater reliability, two senior CT radiographers performed density measurements using standard region of interest (ROI) tool on the CTs with the ROI placed on the mid (ROI 1) and posterior (ROI 2) acromion. ROIs were selected as the most common locations for acromion fracture post RTSA. Measurements were repeated at least 6 weeks apart. Intra‐class coefficients (ICC) were used to determine intra‐ and inter‐rater reliability.Results: ICCs demonstrated good to high intra‐rater and inter‐rater reliability for both ROI 1 and ROI 2 across all three groups. The lower margin of 95% confidence intervals was more than 0 for all intra‐class coefficients.Conclusion: This study demonstrates a reliable method of measuring acromion density on CT. This method can be used to assess bone mineral density in the clinical setting and in future studies investigating ASF following RTSA.
- 9 September 2024
- Published by Wiley in Journal of Medical Imaging and Radiation Oncology
- Vol. 68 (6) , 673-679
Reliable technique for acromion density assessment on CT
Introduction: Acromial stress fracture (ASF) is an uncommon but acknowledged complication of reverse total shoulder arthroplasty (RTSA). There is no standardised method to directly measure the bone mineral density of the acromion to allow a detailed analysis of the potential mechanism of ASF. The aim is to establish a reliable and reproducible technique for measurement of acromial density on computer tomography (CT).Methods: A retrospective review on CT scans obtained for three groups of patients: those planned for RTSA (n = 26); age and gender‐matched non‐operative (n = 26); and young non‐operative patients (n = 28) were performed. Standardised axial images of 1 mm thickness at 1 mm increments were created following horizontal straightening on the coronal and sagittal views. To assess inter‐rater reliability, two senior CT radiographers performed density measurements using standard region of interest (ROI) tool on the CTs with the ROI placed on the mid (ROI 1) and posterior (ROI 2) acromion. ROIs were selected as the most common locations for acromion fracture post RTSA. Measurements were repeated at least 6 weeks apart. Intra‐class coefficients (ICC) were used to determine intra‐ and inter‐rater reliability.Results: ICCs demonstrated good to high intra‐rater and inter‐rater reliability for both ROI 1 and ROI 2 across all three groups. The lower margin of 95% confidence intervals was more than 0 for all intra‐class coefficients.Conclusion: This study demonstrates a reliable method of measuring acromion density on CT. This method can be used to assess bone mineral density in the clinical setting and in future studies investigating ASF following RTSA.