GHGregory Hoy

Gregory Hoy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gregory Hoy has a total of 232 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    PyroTITAN Pyrocarbon Shoulder Hemiarthroplasty

    by Gregory Hoy, Kenan Burrows, Andrew McBride, Mark Ross, Katherine Davis, Sarah Warby

    Background: Pyrocarbon hemiarthroplasty (HA) is a recent option for younger patients with end-stage glenohumeral joint (GHJ) arthritis. Early results are promising but limited by study bias. The aim of this study was to evaluate medium-term clinical and radiographic outcomes following PyroTITAN pyrocarbon HA. Methods: One hundred and nineteen shoulders with GHJ arthritis in 115 patients (mean age, 56.5 years; 92 shoulders were in male patients) underwent PyroTITAN pyrocarbon HA. Primary patient-reported outcome measures (PROMs) included the Western Ontario Osteoarthritis of the Shoulder Index and American Shoulder and Elbow Surgeons score. Clinicians assessed shoulder range of motion and abduction strength. PROMs and clinician evaluations were recorded preoperatively and at 6, 12, and 24 months and 5 years postoperatively. Postoperative complications were recorded, and radiographs were evaluated for glenoid erosion. Implant survival was calculated over the 5-year follow-up period. Data were analyzed on an intention-to-treat basis using linear mixed models for continuous data and Friedman analysis of variance for ordinal data. Kaplan-Meier analysis assessed revision-free survival. Significance was set at p < 0.05. Results: There was significant improvement in all PROMs and ranges of motion at 6, 12, and 24 months and 5 years postoperatively. Abduction strength was significantly improved at 24 months. Seven complications (5.9%) were recorded: ongoing pain (n = 2), stiffness (n = 2), pain and stiffness (n = 2), and implant fracture (n = 1). There were 3 revisions (2.5%) and thus a 97.5% five-year survival rate. Glenoid erosion increased slightly but not significantly over time. Conclusions: The findings in our patient series support the PyroTITAN HA implant as a viable option for GHJ arthritis across a broad age range, including younger patients. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.

  • Computed tomography density of the acromion prior to reverse total shoulder arthroplasty

    by Shu Su, Sarah Warby, Xiao Chen, Julie Tate, Gregory Hoy, Warwick Wright, Shane Barwood, Brendan Soo, Richard Dallalana, Andrew H. Rotstein

  • Open Access

    Posterior capsulolabral reconstruction results in good clinical and return to sport outcomes in tennis players with microtraumatic posterior shoulder instability

    by Franziska Eckers, Lyn Watson, Simon Balster, Sarah Warby, Maike S. Müller, Emma Hoy, Paul Borbas, Gregory Hoy

  • Correcting Excessive Glenoid Retroversion in Combination With Posterior Glenoid Bone Grafting Leads to Improved Glenohumeral Contact Pressures in a Cadaveric Posterior Instability Model

    by Lukas Ernstbrunner, Alexander Paszicsnyek, Maximilian Vetter, Manuel Waltenspül, Paul Borbas, Fraser W. Francis-Pester, Gregory A. Hoy, David C. Ackland, Samy Bouaicha, Karl Wieser

    Background: The extent to which excessive glenoid retroversion leads to increased glenohumeral contact pressures and whether these increases can be mitigated surgically is unknown. Purpose: To evaluate the effect of excessive glenoid retroversion and posterior iliac crest bone grafting (ICBG) with or without glenoid osteotomy on glenohumeral contact patterns. Study Design: Controlled laboratory study. Methods: Six fresh-frozen shoulders had a posterior open-wedge glenoid osteotomy allowing glenoid retroversion to be set at 0°, 10°, and 20°. Four conditions were simulated consecutively on the same specimen at each retroversion angle: intact glenohumeral joint, posterior Bankart lesion, 20% posterior glenoid deficiency, and posterior ICBG (at 20° of retroversion; corrected to 10° and 0° of retroversion). The contact pattern for each specimen was evaluated in the jerk position (60° of glenohumeral anteflexion, 60° of internal rotation) by measuring mean and peak contact pressures (megapascals), peak contact pressure distance (millimeters), and mean contact area (square millimeters). Results: In the intact condition, retroversion of 20° resulted in a significant decrease in contact area but did not significantly affect contact pressure. Creating a posterior Bankart lesion and/or posterior glenoid deficiency showed a significant increase in mean and peak contact pressure at all 3 retroversion angles ( P < .05). Correcting glenoid retroversion to 0° in combination with ICBG resulted in comparable contact area and mean and peak contact pressure of the intact condition ( P > .05). At 10° and 20° of glenoid retroversion, ICBG resulted in significantly higher peak and mean contact pressure (mean not significantly different at 10°) and significantly lower contact area as compared with the intact condition ( P < .05). Conclusion: Glenohumeral contact patterns highly depend on the amount of glenoid retroversion and posterior labral and/or bony glenoid integrity. Only the combination of ICBG and glenoid osteotomy to correct glenoid retroversion to 0° resulted in glenohumeral contact patterns comparable to the native condition with 0° of retroversion. Clinical Relevance: The combined effect of posterior glenoid bone grafting and correcting excessive glenoid retroversion (20°) may correct abnormal glenohumeral contact patterns.

  • Bone Defects in Posterior Instability

    by Gregory Hoy, Michael Blaser, Lukas Ernstbrunner


  • The Failed Posterior Shoulder Stabilization

    by Gregory Hoy, Michael Blaser, Lukas Ernstbrunner

  • Open Access

    The efficacy of conservative management of micro-traumatic posterior shoulder instability

    by Lyn Watson, Simon Balster, Sarah Warby, Ross Lenssen, Gregory Hoy, Shane Barwood, Jacqui French, Bonnie Kerr, Sam Lawrence, Charlotte Ganderton, et al.


  • Open Access

    Anconeus Exertional Compartment Syndrome and Posterolateral Rotatory Elbow Instability: A Clinical Association and Rare Cause of Elbow Pain

    by Gregory Hoy, Trefor James, Paul Jarman, Sarah Warby

    Background: Anconeus compartment syndrome is a rarely reported compartment syndrome in the anconeus muscle compartment of the forearm. It has anatomic and pathophysiological associations with posterolateral rotatory instability (PLRI) of the elbow. Purpose: To present the history, management, and outcomes of 4 patients with anconeus compartment syndrome. Secondary aims were to (1) establish normative anconeus pressures and (2) measure the volume of this compartment with and without PLRI in cadavers. Study Design: Case series; Level of evidence, 4. Methods: Four patients with clinical signs of anconeus compartment syndrome (2 gymnasts, 1 swimmer, and 1 footballer/weightlifter) were identified over a 3-year period (2015-2017 inclusive). Patient history, sporting activity, physical examination, anconeus compartment pressures, and treatment outcomes were recorded. Manometry of the anconeus compartment in 2 healthy male controls was performed to establish normative compartment pressures. Anconeus volumetric anatomy and the effect of creating PLRI on compartment volume was investigated in 4 cadaveric elbows. Results: All 4 patients had microtraumatic PLRI, and 2 patients had anconeus hypertrophy. Anconeus compartment pressures at rest and at 2-minutes postexercise were median 28.0 and 67.5 mm Hg, respectively, in the patients and mean 16.5 and 18 mm Hg, respectively, in the controls. Simultaneous fasciotomy and PLRI reconstructive procedures were performed in 2 patients, with outcomes showing full return to competition. Fasciotomy alone was performed in 2 patients to allow return to competition, with both requiring later reconstruction to address PLRI. Cadaver dissection revealed that the anconeus compartment was extremely small and that creation of PLRI reduced the direct volume of the compartment and increased the distance between the anconeus origin and insertion. Conclusion: Our case series demonstrated that anconeus compartment syndrome can occur in upper limb-dominant athletes in the presence of PLRI and anconeus hypertrophy. Pain is relieved by fasciotomy, but definitive treatment of the underlying instability prevents further symptomatology.


  • Reliable technique for acromion density assessment on CT

    by Shu Su, Xiao Chen, Sarah Warby, Julie Tate, Penelope Brooke, Shane Barwood, Gregory Hoy, Brendan Soo, Richard Dallalana, Warwick Wright, et al.

    Introduction: Acromial stress fracture (ASF) is an uncommon but acknowledged complication of reverse total shoulder arthroplasty (RTSA). There is no standardised method to directly measure the bone mineral density of the acromion to allow a detailed analysis of the potential mechanism of ASF. The aim is to establish a reliable and reproducible technique for measurement of acromial density on computer tomography (CT).Methods: A retrospective review on CT scans obtained for three groups of patients: those planned for RTSA (n = 26); age and gender‐matched non‐operative (n = 26); and young non‐operative patients (n = 28) were performed. Standardised axial images of 1 mm thickness at 1 mm increments were created following horizontal straightening on the coronal and sagittal views. To assess inter‐rater reliability, two senior CT radiographers performed density measurements using standard region of interest (ROI) tool on the CTs with the ROI placed on the mid (ROI 1) and posterior (ROI 2) acromion. ROIs were selected as the most common locations for acromion fracture post RTSA. Measurements were repeated at least 6 weeks apart. Intra‐class coefficients (ICC) were used to determine intra‐ and inter‐rater reliability.Results: ICCs demonstrated good to high intra‐rater and inter‐rater reliability for both ROI 1 and ROI 2 across all three groups. The lower margin of 95% confidence intervals was more than 0 for all intra‐class coefficients.Conclusion: This study demonstrates a reliable method of measuring acromion density on CT. This method can be used to assess bone mineral density in the clinical setting and in future studies investigating ASF following RTSA.