Omar M. Aldaas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Omar M. Aldaas has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Jonathan Chong Hsu
University of California, San Diego
9 shared publications - Gregory K. Feld
Department of Medicine University of California San Diego La Jolla California USA
4 shared publications Amer M. Aldaas
A.T. Still University School of Osteopathic Medicine, Mesa, AZ (A.M.A.).
3 shared publicationsDavid Krummen
Section of Cardiac Electrophysiology, Division of Cardiology at the University of California San Diego Health System, La Jolla, California
3 shared publicationsFarshad Raissi
Section of Cardiac Electrophysiology, Division of Cardiology at the University of California San Diego Health System, La Jolla, California
3 shared publicationsFrederick T. Han
Section of Cardiac Electrophysiology, Division of Cardiology at the University of California San Diego Health System, La Jolla, California
3 shared publications
Latest Publications
- 1 March 2025
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 18 (3) , e013294
Harmonized Definitions and Nomenclature for Use in Pulsed Field Ablation
- 1 March 2025
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 18 (3) , e013294
Harmonized Definitions and Nomenclature for Use in Pulsed Field Ablation
- Open Access
- 22 May 2024
- Published by Elsevier in Structural Heart
- Vol. 9 (1) , 100319
Tricuspid Regurgitation in the Setting of Cardiac Implantable Electronic Devices
- 22 May 2024
- Published by Elsevier in Structural Heart
- Vol. 9 (1) , 100319
Open AccessTricuspid Regurgitation in the Setting of Cardiac Implantable Electronic Devices
- Open Access
- 19 December 2023
- Published by Wiley in Clinical Cardiology
- Vol. 47 (2)
Response to Letter to the Editor
- 19 December 2023
- Published by Wiley in Clinical Cardiology
- Vol. 47 (2)
Open AccessResponse to Letter to the Editor
- Open Access
- 12 September 2023
- Published by Elsevier in Heart Rhythm O2
- Vol. 4 (10) , 599-608
Safety and acute efficacy of catheter ablation for atrial fibrillation with pulsed field ablation vs thermal energy ablation: A meta-analysis of single proportions
- 12 September 2023
- Published by Elsevier in Heart Rhythm O2
- Vol. 4 (10) , 599-608
Open AccessSafety and acute efficacy of catheter ablation for atrial fibrillation with pulsed field ablation vs thermal energy ablation: A meta-analysis of single proportions
- Open Access
- 25 August 2023
- Published by Wiley in Clinical Cardiology
- Vol. 46 (12) , 1488-1494
Safety and efficacy of catheter ablation of atrial fibrillation in the very elderly (≥80 years old): Insights from the UC San Diego AF Ablation Registry
Background: Catheter ablation improves outcomes in symptomatic atrial fibrillation (AF) patients. However, its safety and efficacy in the very elderly (≥80 years old) is not well described.Hypothesis: Ablation of AF in the very elderly is safe and effective.Methods: We performed a retrospective study of all patients who underwent catheter ablation enrolled in the University of California, San Diego AF Ablation Registry. The primary outcome was freedom from atrial arrhythmias on or off antiarrhythmic drugs (AADs).Results: Of 847 patients, 42 (5.0%) were 80 years of age or greater with a median age of 81.5 (80–82.3) and 805 (95.0%) were less than 80 years of age with a median age of 64.4 (57.6–70.2). Among those who were ≥80 years old, 29 were undergoing de novo ablation (69.0%), whereas in the younger cohort, 518 (64.5%) were undergoing de novo ablation (p = .548). There were no statistically significant differences in fluoroscopy (p = .406) or total procedure times (p = .076), AAD use (p = .611), or procedural complications (p = .500) between groups. After multivariable adjustment, there were no statistically significant differences in recurrence of any atrial arrhythmias on or off AAD (adjusted hazard ratio [AHR]: 0.75; 95% confidence interval [CI]: 0.45–1.23; p = .252), all‐cause hospitalizations (AHR: 0.86; 95% CI: 0.46–1.60; p = .626), or all‐cause mortality (AHR: 4.48; 95% CI: 0.59–34.07; p = .147) between the very elderly and the younger cohort.Conclusion: In this registry analysis, catheter ablation of AF appears similarly effective and safe in patients 80 years or older when compared to a younger cohort.
- 25 August 2023
- Published by Wiley in Clinical Cardiology
- Vol. 46 (12) , 1488-1494
Open AccessSafety and efficacy of catheter ablation of atrial fibrillation in the very elderly (≥80 years old): Insights from the UC San Diego AF Ablation Registry
Background: Catheter ablation improves outcomes in symptomatic atrial fibrillation (AF) patients. However, its safety and efficacy in the very elderly (≥80 years old) is not well described.Hypothesis: Ablation of AF in the very elderly is safe and effective.Methods: We performed a retrospective study of all patients who underwent catheter ablation enrolled in the University of California, San Diego AF Ablation Registry. The primary outcome was freedom from atrial arrhythmias on or off antiarrhythmic drugs (AADs).Results: Of 847 patients, 42 (5.0%) were 80 years of age or greater with a median age of 81.5 (80–82.3) and 805 (95.0%) were less than 80 years of age with a median age of 64.4 (57.6–70.2). Among those who were ≥80 years old, 29 were undergoing de novo ablation (69.0%), whereas in the younger cohort, 518 (64.5%) were undergoing de novo ablation (p = .548). There were no statistically significant differences in fluoroscopy (p = .406) or total procedure times (p = .076), AAD use (p = .611), or procedural complications (p = .500) between groups. After multivariable adjustment, there were no statistically significant differences in recurrence of any atrial arrhythmias on or off AAD (adjusted hazard ratio [AHR]: 0.75; 95% confidence interval [CI]: 0.45–1.23; p = .252), all‐cause hospitalizations (AHR: 0.86; 95% CI: 0.46–1.60; p = .626), or all‐cause mortality (AHR: 4.48; 95% CI: 0.59–34.07; p = .147) between the very elderly and the younger cohort.Conclusion: In this registry analysis, catheter ablation of AF appears similarly effective and safe in patients 80 years or older when compared to a younger cohort.
- Open Access
- 15 May 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (5)
In-hospital complications associated with pulmonary vein isolation with adjunctive lesions: the NCDR AFib Ablation Registry
Aims: No prior study has been adequately powered to evaluate real-world safety outcomes in those receiving adjunctive ablation lesions beyond pulmonary vein isolation (PVI). We sought to evaluate characteristics and in-hospital complications among patients undergoing PVI with and without adjunctive lesions. Methods and results: Patients in the National Cardiovascular Data Registry AFib Ablation Registry undergoing first-time atrial fibrillation (AF) ablation between 2016 and 2020 were identified and stratified into paroxysmal (PAF) and persistent AF, and separated into PVI only, PVI + cavotricuspid isthmus (CTI) ablation, and PVI + adjunctive (superior vena cava isolation, coronary sinus, vein of Marshall, atypical atrial flutter lines, other). Adjusted odds of adverse events were calculated using multivariable logistic regression. A total of 50 937 patients [PAF: 30 551 (60%), persistent AF: 20 386 (40%)] were included. Among those with PAF, there were no differences in the adjusted odds of complications between PVI + CTI or PVI + adjunctive when compared with PVI only. Among persistent AF, PVI + adjunctive was associated with a higher risk of any complication [3.0 vs. 4.5%, odds ratio (OR) 1.30, 95% confidence interval (CI) 1.07–1.58] and major complication (0.8 vs. 1.4%, OR 1.56, 95% CI 1.10–2.21), while no differences were observed in PVI + CTI compared with PVI only. Overall, there was high heterogeneity in adjunctive lesion type, and those receiving adjunctive lesions had a higher comorbidity burden. Conclusion: Additional CTI ablation was common without an increased risk of complications. Adjunctive lesions other than CTI are commonly performed in those with more comorbidities and were associated with an increased risk of complications in persistent AF, although the current analysis is limited by high heterogeneity in adjunctive lesion set type.
- 15 May 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (5)
Open AccessIn-hospital complications associated with pulmonary vein isolation with adjunctive lesions: the NCDR AFib Ablation Registry
Aims: No prior study has been adequately powered to evaluate real-world safety outcomes in those receiving adjunctive ablation lesions beyond pulmonary vein isolation (PVI). We sought to evaluate characteristics and in-hospital complications among patients undergoing PVI with and without adjunctive lesions. Methods and results: Patients in the National Cardiovascular Data Registry AFib Ablation Registry undergoing first-time atrial fibrillation (AF) ablation between 2016 and 2020 were identified and stratified into paroxysmal (PAF) and persistent AF, and separated into PVI only, PVI + cavotricuspid isthmus (CTI) ablation, and PVI + adjunctive (superior vena cava isolation, coronary sinus, vein of Marshall, atypical atrial flutter lines, other). Adjusted odds of adverse events were calculated using multivariable logistic regression. A total of 50 937 patients [PAF: 30 551 (60%), persistent AF: 20 386 (40%)] were included. Among those with PAF, there were no differences in the adjusted odds of complications between PVI + CTI or PVI + adjunctive when compared with PVI only. Among persistent AF, PVI + adjunctive was associated with a higher risk of any complication [3.0 vs. 4.5%, odds ratio (OR) 1.30, 95% confidence interval (CI) 1.07–1.58] and major complication (0.8 vs. 1.4%, OR 1.56, 95% CI 1.10–2.21), while no differences were observed in PVI + CTI compared with PVI only. Overall, there was high heterogeneity in adjunctive lesion type, and those receiving adjunctive lesions had a higher comorbidity burden. Conclusion: Additional CTI ablation was common without an increased risk of complications. Adjunctive lesions other than CTI are commonly performed in those with more comorbidities and were associated with an increased risk of complications in persistent AF, although the current analysis is limited by high heterogeneity in adjunctive lesion set type.
- 1 December 2019
- Published by Wiley in Echocardiography
- Vol. 36 (12) , 2145-2151
Accuracy of left ventricular ejection fraction determined by automated analysis of handheld echocardiograms: A comparison of experienced and novice examiners
Background: Handheld ultrasound devices have been developed that facilitate imaging in new clinical settings. However, quantitative assessment has been difficult. Software algorithms have recently been developed with the aim of providing rapid measurements of left ventricular ejection fraction (LVEF) with minimal operator input.Methods: We prospectively enrolled a cohort of 70 patients scheduled to undergo echocardiography at the University of California, San Diego. Each patient underwent a standard echocardiography examination by an experienced sonographer as well as a handheld ultrasound with automated software by both the sonographer and an inexperienced resident.Results: There was a positive correlation between the LVEFs obtained from the standard transthoracic echocardiogram and handheld device in the hands of a novice (r = 0.62; 95% CI 0.45‐0.75) and experienced sonographer (r = 0.69; 95% CI 0.54‐0.80). The sensitivity and specificity to detect a reduced LVEF (<50%) were 69% and 96% for the novice and 64% and 98% for the experienced sonographer. The sensitivity and specificity to detect a severely reduced LVEF (<35%) were 67% and 97% for the novice and 56% and 93% for the experienced sonographer, but when limited to recordings of at least adequate quality, improved to 100% and 100% for the novice and 100% and 98% for the experienced sonographer, respectively.Conclusion: These data demonstrate that the handheld ultrasound device paired with novel software can provide a clinically useful estimate of LVEF when the images are of adequate quality and yield results by novice examiners that are similar to experienced sonographers.
- 1 December 2019
- Published by Wiley in Echocardiography
- Vol. 36 (12) , 2145-2151
Accuracy of left ventricular ejection fraction determined by automated analysis of handheld echocardiograms: A comparison of experienced and novice examiners
Background: Handheld ultrasound devices have been developed that facilitate imaging in new clinical settings. However, quantitative assessment has been difficult. Software algorithms have recently been developed with the aim of providing rapid measurements of left ventricular ejection fraction (LVEF) with minimal operator input.Methods: We prospectively enrolled a cohort of 70 patients scheduled to undergo echocardiography at the University of California, San Diego. Each patient underwent a standard echocardiography examination by an experienced sonographer as well as a handheld ultrasound with automated software by both the sonographer and an inexperienced resident.Results: There was a positive correlation between the LVEFs obtained from the standard transthoracic echocardiogram and handheld device in the hands of a novice (r = 0.62; 95% CI 0.45‐0.75) and experienced sonographer (r = 0.69; 95% CI 0.54‐0.80). The sensitivity and specificity to detect a reduced LVEF (<50%) were 69% and 96% for the novice and 64% and 98% for the experienced sonographer. The sensitivity and specificity to detect a severely reduced LVEF (<35%) were 67% and 97% for the novice and 56% and 93% for the experienced sonographer, but when limited to recordings of at least adequate quality, improved to 100% and 100% for the novice and 100% and 98% for the experienced sonographer, respectively.Conclusion: These data demonstrate that the handheld ultrasound device paired with novel software can provide a clinically useful estimate of LVEF when the images are of adequate quality and yield results by novice examiners that are similar to experienced sonographers.