Chang-Hung Hsu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chang-Hung Hsu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Shan-Jen Cheng
Army Academy
3 shared publications - Te-Jen Chang
Department of Electrical Engineering, Ming Chi University of Technology, New Taipei City 24301, Taiwan
3 shared publications Chang Ann-Shing
1 shared publicationChia-Shiang Yao
Division of Electrical Engineering, Fortune Electric Company Ltd., Tao-Yuan 320, Taiwan
1 shared publicationChia-Wen Chang
Chang Gung University 2 Department of Electrical Engineering Tao-Yuan 333, Taiwan
1 shared publication- Chin-Ping Fung
Department of Mechanical Engineering, Asia Eastern University of Science and Technology, New Taipei City 220303, Taiwan
1 shared publication
Latest Publications
- Open Access
- 1 January 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (1)
Effect of relationship between magnetic moment energy variation and knee point squareness ratio on transformer noise
This paper presents the effects of the magnetostriction of core loss and noise (sound level) on power transformers between 15 and 120 MVA and the results of an analysis relative to the parameters of the squareness ratio (SR). Three types of soft magnetic silicon steel were used in this study: 30ZH105, 27ZH100, and 27PH100. The hysteresis loop and magnetostriction were measured for various magnetic parameters of sound level and core loss. Moreover, finite element analysis was performed to indicate the flux density and the parameter of ΔBr variation dependent on transformer loss and noise. The design values for transformers with several capacities, with respect to sound level and core loss performance were compared. Studies have indicated that transformer noise includes hysteresis and the volume of ferromagnetic materials. The sound level performance displayed a lower noise result because of the core with a higher SR. Besides, it can be observed that the material has innate magnetic anisotropy and the greater the magnetic moment flip energy then induced higher the noise. Additionally, it was observed that a higher SR. of 27ZH100 for core loss was not significant. When the SR. with respect to the sound level was high, the experimental and design values were very similar by using fast Fourier transform to observe the noise operated at a different frequency spectrum between 50 Hz and 10 kHz. The design values for transformers with varying capacities, with respect to the sound level and core loss performance were analyzed and compared with the experimental values.
- 1 January 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (1)
Open AccessEffect of relationship between magnetic moment energy variation and knee point squareness ratio on transformer noise
This paper presents the effects of the magnetostriction of core loss and noise (sound level) on power transformers between 15 and 120 MVA and the results of an analysis relative to the parameters of the squareness ratio (SR). Three types of soft magnetic silicon steel were used in this study: 30ZH105, 27ZH100, and 27PH100. The hysteresis loop and magnetostriction were measured for various magnetic parameters of sound level and core loss. Moreover, finite element analysis was performed to indicate the flux density and the parameter of ΔBr variation dependent on transformer loss and noise. The design values for transformers with several capacities, with respect to sound level and core loss performance were compared. Studies have indicated that transformer noise includes hysteresis and the volume of ferromagnetic materials. The sound level performance displayed a lower noise result because of the core with a higher SR. Besides, it can be observed that the material has innate magnetic anisotropy and the greater the magnetic moment flip energy then induced higher the noise. Additionally, it was observed that a higher SR. of 27ZH100 for core loss was not significant. When the SR. with respect to the sound level was high, the experimental and design values were very similar by using fast Fourier transform to observe the noise operated at a different frequency spectrum between 50 Hz and 10 kHz. The design values for transformers with varying capacities, with respect to the sound level and core loss performance were analyzed and compared with the experimental values.
- Open Access
- 1 February 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (2) , 025043
Electromagnetic alternators with composite amorphous alloy shell for improving characteristics
In this study, a magnetic casing encapsulating a generator is used to improve the electromagnetic and power characteristics of the generator. Two types of two-pole AC generators are proposed: one is a bare-bonded (NC) type and the other is an iron-based amorphous alloy material covering the generator casing. In this study, Fe-Si-B amorphous thin strips were annealed between 300 and 380 °C and soaked for 60 min to observe and analyze the structural changes and the evolution of properties under different temperature conditions. After the thin strip is annealed at 400 °C, α-Fe dendrites begin to appear, and at 450 °C, a large number of α-Fe dendrites are formed. The demagnetization rate of the permanent magnet area near the bottom of the pole piece is the highest for the generator with an amorphous alloy shell because the magnetic flux leakage from the side frame of the pole piece changes the magnetic flux path, thereby affecting the demagnetization performance. In this study, three amorphous alloys, HB1-M, HB1, and SA1, were used as the cladding permanent magnet generator shell, and annealing and non-annealing procedures were conducted to observe the influence on the magnetic power of the generator. The magnetic flux on the surface of the amorphous shell was measured by a magnetic fluxmeter. For experiments with an amorphous shell, the results show that the annealed center point magnetic flux densities were approximately HB1-M (15 mT), HB1 (12 mT), and SA1 (10 mT), and the marginal non-annealed amorphous thin strip could reach ∼7–5 mT. The measured generator harmonic component of SA1 is higher than the voltage and current harmonics, reflecting that the magnetization direction of the magnetic shell in the demagnetization region is covered by the magnetic flux density. Because of central flame annealing, the magnetic shell is paramagnetic, and it helps to reduce the noise by at least 5 dB. The generator current harmonic characteristic of the HB1-M material is smaller than that of the HB1 and SA1 materials. In this study, a composite amorphous material was used to cover the generator casing; it was verified that HB1-M + HB1 + SA1 has the lowest noise characteristics for the generator. The generator noise of the composited material (HB1-M + HB1 + SA1) can be reduced to below 69 dB, which is ∼7–9 dB lower than that of a single amorphous material.
- 1 February 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (2) , 025043
Open AccessElectromagnetic alternators with composite amorphous alloy shell for improving characteristics
In this study, a magnetic casing encapsulating a generator is used to improve the electromagnetic and power characteristics of the generator. Two types of two-pole AC generators are proposed: one is a bare-bonded (NC) type and the other is an iron-based amorphous alloy material covering the generator casing. In this study, Fe-Si-B amorphous thin strips were annealed between 300 and 380 °C and soaked for 60 min to observe and analyze the structural changes and the evolution of properties under different temperature conditions. After the thin strip is annealed at 400 °C, α-Fe dendrites begin to appear, and at 450 °C, a large number of α-Fe dendrites are formed. The demagnetization rate of the permanent magnet area near the bottom of the pole piece is the highest for the generator with an amorphous alloy shell because the magnetic flux leakage from the side frame of the pole piece changes the magnetic flux path, thereby affecting the demagnetization performance. In this study, three amorphous alloys, HB1-M, HB1, and SA1, were used as the cladding permanent magnet generator shell, and annealing and non-annealing procedures were conducted to observe the influence on the magnetic power of the generator. The magnetic flux on the surface of the amorphous shell was measured by a magnetic fluxmeter. For experiments with an amorphous shell, the results show that the annealed center point magnetic flux densities were approximately HB1-M (15 mT), HB1 (12 mT), and SA1 (10 mT), and the marginal non-annealed amorphous thin strip could reach ∼7–5 mT. The measured generator harmonic component of SA1 is higher than the voltage and current harmonics, reflecting that the magnetization direction of the magnetic shell in the demagnetization region is covered by the magnetic flux density. Because of central flame annealing, the magnetic shell is paramagnetic, and it helps to reduce the noise by at least 5 dB. The generator current harmonic characteristic of the HB1-M material is smaller than that of the HB1 and SA1 materials. In this study, a composite amorphous material was used to cover the generator casing; it was verified that HB1-M + HB1 + SA1 has the lowest noise characteristics for the generator. The generator noise of the composited material (HB1-M + HB1 + SA1) can be reduced to below 69 dB, which is ∼7–9 dB lower than that of a single amorphous material.
- Open Access
- 26 November 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (12) , 2086
Effect of Local Annealing on Magnetic Flux Distribution and Noise in a Micro-Generator with Amorphous Shell
This study examined micro-alternators with two different housing structures––an uncoated shell and a shell coated with an iron-based amorphous-alloy soft magnetic material. The electromagnetic power and noise characteristics of generators with these shell structures were measured and analyzed. The material used for the shell coating was the SA1 amorphous alloy. The magnetic property of the SA1 material was evaluated, including its hysteresis expansion, hysteresis-loop parameters, α-Fe crystal formation, thermogravimetric transfer, and Curie temperature. The center point of the casing was subjected to flame local-heating annealing to attain ferromagnetism and paramagnetism material characteristics. The experimental shell was between these magnetic-phase-transition properties and was used to observe the magnetic power and noise characteristics of the microgenerator. The measured magnetic flux at the center of the amorphous shell was 1.2–2.4 mT, and the magnetic flux distributed around the shell was 0.6–1.0 mT. The generator with the amorphous-alloy shell had the lowest demagnetization rate in the permanent magnet region, which was close to the bottom of the pole piece, and the magnetic flux leakage of the pole-piece side frame changed the magnetic flux path, thus affecting the demagnetization performance. For the noise experiment, the flame-annealing temperature of the local center point of the amorphous casing reached the Curie temperature, and the noise characteristics of the casing can be reduced by 15 dB compared to those of the generator without the casing. However, the overall performance of generator harmonics and power were not fully improved.
- 26 November 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (12) , 2086
Open AccessEffect of Local Annealing on Magnetic Flux Distribution and Noise in a Micro-Generator with Amorphous Shell
This study examined micro-alternators with two different housing structures––an uncoated shell and a shell coated with an iron-based amorphous-alloy soft magnetic material. The electromagnetic power and noise characteristics of generators with these shell structures were measured and analyzed. The material used for the shell coating was the SA1 amorphous alloy. The magnetic property of the SA1 material was evaluated, including its hysteresis expansion, hysteresis-loop parameters, α-Fe crystal formation, thermogravimetric transfer, and Curie temperature. The center point of the casing was subjected to flame local-heating annealing to attain ferromagnetism and paramagnetism material characteristics. The experimental shell was between these magnetic-phase-transition properties and was used to observe the magnetic power and noise characteristics of the microgenerator. The measured magnetic flux at the center of the amorphous shell was 1.2–2.4 mT, and the magnetic flux distributed around the shell was 0.6–1.0 mT. The generator with the amorphous-alloy shell had the lowest demagnetization rate in the permanent magnet region, which was close to the bottom of the pole piece, and the magnetic flux leakage of the pole-piece side frame changed the magnetic flux path, thus affecting the demagnetization performance. For the noise experiment, the flame-annealing temperature of the local center point of the amorphous casing reached the Curie temperature, and the noise characteristics of the casing can be reduced by 15 dB compared to those of the generator without the casing. However, the overall performance of generator harmonics and power were not fully improved.
- Open Access
- 1 August 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 9441-9452
Prognostics for remaining useful life estimation in proton exchange membrane fuel cell by dynamic recurrent neural networks
- 1 August 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 9441-9452
Open AccessPrognostics for remaining useful life estimation in proton exchange membrane fuel cell by dynamic recurrent neural networks
- Open Access
- 22 March 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (7) , 3231
Low-Cost and High-Efficiency Electromechanical Integration for Smart Factories of IoT with CNN and FOPID Controller Design under the Impact of COVID-19
This study proposes a design for unmanned chemical factories and implementation based on ultra-low-cost Internet of Things technology, to combat the impact of COVID-19 on industrial factories. A safety and private blockchain network architecture was established, including a three-layer network structure comprising edge, fog, and cloud calculators. Edge computing uses a programmable logic controller and a single-chip microcomputer to transmit and control the motion path of a four-axis robotic arm motor. The fog computing architecture is implemented using Python software. The structure is integrated and applied using a convolutional neural network (CNN) and a fractional-order proportional-integral-derivative controller (FOPID). In addition, edge computing and fog computing signals are transmitted through the blockchain, and can be directly uploaded to the cloud computing controller for signal integration. The integrated application of the production line sensor and image recognition based on the network layer was addressed. We verified the image recognition of the CNN and the robot motor signal control of the FOPID. This study proposes that a CNN + FOPID method can improve the efficiency of the factory by more than 50% compared with traditional manual operators. The low-cost, high-efficiency equipment of the new method has substantial contribution and application potential.
- 22 March 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (7) , 3231
Open AccessLow-Cost and High-Efficiency Electromechanical Integration for Smart Factories of IoT with CNN and FOPID Controller Design under the Impact of COVID-19
This study proposes a design for unmanned chemical factories and implementation based on ultra-low-cost Internet of Things technology, to combat the impact of COVID-19 on industrial factories. A safety and private blockchain network architecture was established, including a three-layer network structure comprising edge, fog, and cloud calculators. Edge computing uses a programmable logic controller and a single-chip microcomputer to transmit and control the motion path of a four-axis robotic arm motor. The fog computing architecture is implemented using Python software. The structure is integrated and applied using a convolutional neural network (CNN) and a fractional-order proportional-integral-derivative controller (FOPID). In addition, edge computing and fog computing signals are transmitted through the blockchain, and can be directly uploaded to the cloud computing controller for signal integration. The integrated application of the production line sensor and image recognition based on the network layer was addressed. We verified the image recognition of the CNN and the robot motor signal control of the FOPID. This study proposes that a CNN + FOPID method can improve the efficiency of the factory by more than 50% compared with traditional manual operators. The low-cost, high-efficiency equipment of the new method has substantial contribution and application potential.
- Open Access
Data-Driven Prognostics of the SOFC System Based on Dynamic Neural Network Models
Prognostics technology is important for the sustainability of solid oxide fuel cell (SOFC) system commercialization, i.e., through failure prevention, reliability assessment, and the remaining useful life (RUL) estimation. To solve SOFC system issues, data-driven prognostics methods based on the dynamic neural network (DNN), one of non-linear models, were investigated in this study. Based on DNN model types, the neural network autoregressive (NNARX) model with external inputs, the neural network autoregressive moving average (NNARMAX) model with external inputs, and the neural network output error (NNOE) were utilized to predict the degradation trend and estimate the RUL. First, the degradation trend prediction was executed to evaluate the correctness of the proposed DNN model structures in the first learning phase. Then, the RUL was estimated on the basis of the degradation trend of the NN models in the second inference phase. The comparison test results show the prediction accuracy of the NNARX model is higher and the RUL estimation can be given within a smaller relative error than the NNARMAX and NNOE models. The evaluation criteria of the root mean square error and mean absolute error of the NNARX model are the smallest among these three models. Therefore, the proposed NNARX model can effectively and precisely provide degradation trend prediction and RUL estimation of the SOFC system.
Open AccessData-Driven Prognostics of the SOFC System Based on Dynamic Neural Network Models
Prognostics technology is important for the sustainability of solid oxide fuel cell (SOFC) system commercialization, i.e., through failure prevention, reliability assessment, and the remaining useful life (RUL) estimation. To solve SOFC system issues, data-driven prognostics methods based on the dynamic neural network (DNN), one of non-linear models, were investigated in this study. Based on DNN model types, the neural network autoregressive (NNARX) model with external inputs, the neural network autoregressive moving average (NNARMAX) model with external inputs, and the neural network output error (NNOE) were utilized to predict the degradation trend and estimate the RUL. First, the degradation trend prediction was executed to evaluate the correctness of the proposed DNN model structures in the first learning phase. Then, the RUL was estimated on the basis of the degradation trend of the NN models in the second inference phase. The comparison test results show the prediction accuracy of the NNARX model is higher and the RUL estimation can be given within a smaller relative error than the NNARMAX and NNOE models. The evaluation criteria of the root mean square error and mean absolute error of the NNARX model are the smallest among these three models. Therefore, the proposed NNARX model can effectively and precisely provide degradation trend prediction and RUL estimation of the SOFC system.
- 28 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 57 (2) , 1-5
Performance of the Noise and Vibration of the AC/DC Signal for a Permanent Magnetic DC Motor
Herein, a single-phase DC permanent magnet motor (PMM) operated at direct current (DC) was proposed, affected by a type of alternating current (AC) signal>5% and frequency between 50 and 3,000 Hz to explore characteristics such as noise, vibration, and motor power efficiency. The finite element method (FEA) was used to model the motor and the transient results of the magnetic flux and current were simulated. The noise level of the motor was experimentally determined for the motor under normal DC power operation subjected to higher hybrid power supply. This indicates that the vibration displacement (mm) and velocity (mm/s) vary, while acceleration (mm/s2) is linearly stable. From the experimental results, the vibration is inversely proportional to the noise. The lower noise level is only observed under medium frequency, similar to a bathtub curve. In addition, when the motor is operated at the low frequency of 50–500 Hz, the characteristics of the power performance were increased more than 1.5 times, including real power P (real power, Watt), apparent power S (apparent power, VA), and reactive power Q (reactive power, VAR), which is much higher than the high-frequency power signal at frequency>500 Hz, gradually stabilizing the motor power. Moreover, a hybrid AC signal of up to 15% was added to the motor system at a frequency between 50 and 500 Hz, drastically changing the displacement and vibration by up to 1.36 times. However, at high frequencies of>1 kHz, the power and noise increase slightly before reaching the steady state.
- 28 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 57 (2) , 1-5
Performance of the Noise and Vibration of the AC/DC Signal for a Permanent Magnetic DC Motor
Herein, a single-phase DC permanent magnet motor (PMM) operated at direct current (DC) was proposed, affected by a type of alternating current (AC) signal>5% and frequency between 50 and 3,000 Hz to explore characteristics such as noise, vibration, and motor power efficiency. The finite element method (FEA) was used to model the motor and the transient results of the magnetic flux and current were simulated. The noise level of the motor was experimentally determined for the motor under normal DC power operation subjected to higher hybrid power supply. This indicates that the vibration displacement (mm) and velocity (mm/s) vary, while acceleration (mm/s2) is linearly stable. From the experimental results, the vibration is inversely proportional to the noise. The lower noise level is only observed under medium frequency, similar to a bathtub curve. In addition, when the motor is operated at the low frequency of 50–500 Hz, the characteristics of the power performance were increased more than 1.5 times, including real power P (real power, Watt), apparent power S (apparent power, VA), and reactive power Q (reactive power, VAR), which is much higher than the high-frequency power signal at frequency>500 Hz, gradually stabilizing the motor power. Moreover, a hybrid AC signal of up to 15% was added to the motor system at a frequency between 50 and 500 Hz, drastically changing the displacement and vibration by up to 1.36 times. However, at high frequencies of>1 kHz, the power and noise increase slightly before reaching the steady state.
- 30 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 55 (11) , 1-7
Fractional Order PID Control for Reduction of Vibration and Noise on Induction Motor
This article aims at investigating the impact of harmonic current, vibration, and noise on induction motors (IMs) with a fractional order (FO) proportional-integral-derivative (PID) controller. Conventional PID controllers are widely used in closed-loop vector-space to control IMs. In general, the parameters of a PID controller should be considered carefully because the vector-space loop can induce imbalanced current and magnetic flux in the α-β sub-plane closed-loop system. If this occurs, the imbalanced current affects not only the IM performance but also the harmonic current, motor vibration, and noise. In this study, an FO PID (PρIλDμ) controller is used for stabilizing the effect of the current and harmonic on the IM. This PID controller is built based on the results of measurements on motor design parameters. By using the phase margin rule to design and determine suitable parameters, several orders of ρ, λ, and μ in their reasonable ranges are evaluated to obtain a relative optimal FO (PρIλDμ) controller. This can improve the performance of the IM in terms of harmonic current, vibration, and noise, more than a conventional PID controller can achieve.
- 30 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 55 (11) , 1-7
Fractional Order PID Control for Reduction of Vibration and Noise on Induction Motor
This article aims at investigating the impact of harmonic current, vibration, and noise on induction motors (IMs) with a fractional order (FO) proportional-integral-derivative (PID) controller. Conventional PID controllers are widely used in closed-loop vector-space to control IMs. In general, the parameters of a PID controller should be considered carefully because the vector-space loop can induce imbalanced current and magnetic flux in the α-β sub-plane closed-loop system. If this occurs, the imbalanced current affects not only the IM performance but also the harmonic current, motor vibration, and noise. In this study, an FO PID (PρIλDμ) controller is used for stabilizing the effect of the current and harmonic on the IM. This PID controller is built based on the results of measurements on motor design parameters. By using the phase margin rule to design and determine suitable parameters, several orders of ρ, λ, and μ in their reasonable ranges are evaluated to obtain a relative optimal FO (PρIλDμ) controller. This can improve the performance of the IM in terms of harmonic current, vibration, and noise, more than a conventional PID controller can achieve.