Jarmo Leppäniemi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jarmo Leppäniemi has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Jari Koskinen
Department of Chemistry and Materials Science, Aalto University School of Chemical Engineering, P.O. Box 16100, FI-00076 Aalto, 02150, Espoo, Finland
3 shared publications- Harri Lipsanen
Department of Electronics and Nanoengineering, Aalto University, Espoo, Finland
2 shared publications Perttu Sippola
Department of Electronics and Nanoengineering, Aalto University School of Electrical Engineering, P.O. Box 13500, FI-00076 Aalto, 02150, Espoo, Finland
2 shared publicationsAntti Peltonen
Aalto-NanoFab, Micronova, Aalto University, P.O. Box 13500, FI-00076 Aalto, 02150, Espoo, Finland
1 shared publicationJari Aromaa
1 shared publicationJari J. Aromaa
Department of Chemical and Metallurgical Engineering, Aalto University School of Chemical Engineering, P.O. Box 16100, FI-00076 Aalto, 02150, Espoo, Finland
1 shared publication
Latest Publications
- Open Access
- 12 February 2018
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 3 (2) , 1791-1800
Effect of Surface Wear on Corrosion Protection of Steel by CrN Coatings Sealed with Atomic Layer Deposition
Corrosion protection of steel obtained with physical vapor deposition (PVD) coatings can be further improved by sealing the intrinsic pinholes with atomic layer deposition (ALD) coatings. In this work, the effect of surface wear on corrosion protection obtained by a hybrid PVD CrN/ALD Al2O3/TiO2 nanolaminate coating was studied. The samples were investigated by alternating surface wear steps and exposure to salt solution and consecutively the progression of corrosion after each wear and each corrosion step was evaluated. Optical microscopy, scanning electron microscopy (SEM), and energy-dispersive spectroscopy showed that the rust spots were almost exclusively located on positions at which the wear steps had removed the top surface of the PVD CrN coating. Nevertheless, even after complete removal of the ALD nanolaminate from the top of the CrN surface by sandpaper grinding, the corrosion current density was less than half compared to the PVD CrN coating alone without surface wear. Cross-sectional SEM images obtained with focused ion beam milling showed not only the presence of the ALD coating at the CrN defects but also the opening of new pathways for the corrosion to attack the substrate. A mechanism for the effect of wear on the structure and corrosion protection of hybrid PVD/ALD coatings is proposed on the basis of this investigation.
- 12 February 2018
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 3 (2) , 1791-1800
Open AccessEffect of Surface Wear on Corrosion Protection of Steel by CrN Coatings Sealed with Atomic Layer Deposition
Corrosion protection of steel obtained with physical vapor deposition (PVD) coatings can be further improved by sealing the intrinsic pinholes with atomic layer deposition (ALD) coatings. In this work, the effect of surface wear on corrosion protection obtained by a hybrid PVD CrN/ALD Al2O3/TiO2 nanolaminate coating was studied. The samples were investigated by alternating surface wear steps and exposure to salt solution and consecutively the progression of corrosion after each wear and each corrosion step was evaluated. Optical microscopy, scanning electron microscopy (SEM), and energy-dispersive spectroscopy showed that the rust spots were almost exclusively located on positions at which the wear steps had removed the top surface of the PVD CrN coating. Nevertheless, even after complete removal of the ALD nanolaminate from the top of the CrN surface by sandpaper grinding, the corrosion current density was less than half compared to the PVD CrN coating alone without surface wear. Cross-sectional SEM images obtained with focused ion beam milling showed not only the presence of the ALD coating at the CrN defects but also the opening of new pathways for the corrosion to attack the substrate. A mechanism for the effect of wear on the structure and corrosion protection of hybrid PVD/ALD coatings is proposed on the basis of this investigation.
- 18 September 2017
- Published by Wiley in European Journal of Oral Sciences
- Vol. 125 (6) , 495-503
Non‐stick properties of thin‐film coatings on dental‐restorative instruments
The non‐stick properties of thin‐film coatings on dental‐restorative instruments were investigated by static contact‐angle measurement using dental filler resin as well as by scanning electron microscopy of the amount of sticking dental restorative material. Furthermore, using a customized dipping measurement set‐up, non‐stick properties were evaluated by measuring force‐by‐time when the instrument was pulled out of restorative material. Minor improvements in non‐stick properties were obtained with commercial diamond‐like carbon and commercial polytetrafluoroethylene‐based coatings. Major improvements were obtained with an in‐house fabricated superhydrophobic coating prepared by a multistep process consisting of surface microstructuring by etching in hydrogen fluoride (HF): hydrogen peroxide (H2O2) (1:1; vol/vol), atomic layer deposition of a 7 nm coating of aluminium oxide and titanium oxide, and a self‐assembled monolayer of fluorinated organosilicon. Superhydrophobic coatings provide a possible future solution to prevent unwanted adnerence of composite restorative material to dental instruments.
- 18 September 2017
- Published by Wiley in European Journal of Oral Sciences
- Vol. 125 (6) , 495-503
Non‐stick properties of thin‐film coatings on dental‐restorative instruments
The non‐stick properties of thin‐film coatings on dental‐restorative instruments were investigated by static contact‐angle measurement using dental filler resin as well as by scanning electron microscopy of the amount of sticking dental restorative material. Furthermore, using a customized dipping measurement set‐up, non‐stick properties were evaluated by measuring force‐by‐time when the instrument was pulled out of restorative material. Minor improvements in non‐stick properties were obtained with commercial diamond‐like carbon and commercial polytetrafluoroethylene‐based coatings. Major improvements were obtained with an in‐house fabricated superhydrophobic coating prepared by a multistep process consisting of surface microstructuring by etching in hydrogen fluoride (HF): hydrogen peroxide (H2O2) (1:1; vol/vol), atomic layer deposition of a 7 nm coating of aluminium oxide and titanium oxide, and a self‐assembled monolayer of fluorinated organosilicon. Superhydrophobic coatings provide a possible future solution to prevent unwanted adnerence of composite restorative material to dental instruments.