Milad Tajik Jamalabad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Milad Tajik Jamalabad has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Mohammad Aminy
3 shared publications- Antonia Gil
Instituto ENERGAIA, Zaragoza University, Campus Rio Ebro, Mariano Esquillor Gomez, 15, 50018 Zaragoza, Spain
2 shared publications Arnold Martínez
Mechanical Engineering Department Universidad del Norte Barranquilla Colombia
2 shared publications- Cristóbal Cortés
Institute of Energy and Resources Efficiency of Aragón (ENERGAIA), University of Zaragoza, 50018 Zaragoza, Spain
2 shared publications - Elham Abohamzeh
Department of Energy, Material and Energy Research Center (MERC), Karaj, Iran
2 shared publications - Georg Frey
Chair of Automation and Energy Systems, Saarland University, Saarbrücken Campus, 66123 Saarbrücken, Germany
2 shared publications
Latest Publications
- Open Access
- 7 July 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (13) , 6811
Performance Prediction of a Hybrid Heat Pump System Integrated with a Biomass Boiler for Rural Dwellings by Means of Machine Learning Techniques
Given the heterogeneity in data on heat pump performance curves across manufacturers, selecting the appropriate one for more detailed studies is complex. Machine learning (ML) techniques can be very helpful in this endeavor. In this case, four techniques were used: artificial neural networks (ANN), support vector machines (SVM), Gaussian Process (GP), and decision trees (DT), to predict HP performance maps. These four techniques were then applied to a hybrid installation consisting of an air-water HP boiler and a biomass boiler modeled with TRNSYS and connected in series. Performance maps were generated using TRNSYS type 581. Key aspects, including overall efficiency, emissions, lifetime costs, and design and control parameters, were then analyzed. The study found that the coefficient of variation of root-mean-square error (CVRMSE) was 14.9% for the DT model, 11.4% for the ANN, 11.1% for the SVM, and 10.7% for the GP model. The GP model was ultimately used to develop an HP performance map due to its highest accuracy, and comparisons with baseline data revealed significant differences in efficiency, operational costs, and emissions, among others.
- 7 July 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (13) , 6811
Open AccessPerformance Prediction of a Hybrid Heat Pump System Integrated with a Biomass Boiler for Rural Dwellings by Means of Machine Learning Techniques
Given the heterogeneity in data on heat pump performance curves across manufacturers, selecting the appropriate one for more detailed studies is complex. Machine learning (ML) techniques can be very helpful in this endeavor. In this case, four techniques were used: artificial neural networks (ANN), support vector machines (SVM), Gaussian Process (GP), and decision trees (DT), to predict HP performance maps. These four techniques were then applied to a hybrid installation consisting of an air-water HP boiler and a biomass boiler modeled with TRNSYS and connected in series. Performance maps were generated using TRNSYS type 581. Key aspects, including overall efficiency, emissions, lifetime costs, and design and control parameters, were then analyzed. The study found that the coefficient of variation of root-mean-square error (CVRMSE) was 14.9% for the DT model, 11.4% for the ANN, 11.1% for the SVM, and 10.7% for the GP model. The GP model was ultimately used to develop an HP performance map due to its highest accuracy, and comparisons with baseline data revealed significant differences in efficiency, operational costs, and emissions, among others.
- Open Access
- 29 May 2026
- Published by TIB Open Publishing in International Sustainable Energy Conference - Proceedings
- Vol. 2
CFD Modelling and Multi-Objective Optimization of a Segmented Open Sorption Heat Storage
Sorption heat storage offers high energy density and low thermal losses, making it attractive for short-term and seasonal solar heat storage in buildings. However, implementation depends on reactor design, particularly in terms of scalability, flow distribution, and pressure losses. Modular open-reactor designs improve scalability, while internal segmentation can reduce pressure drop by shortening the flow path. However, segmentation may also cause non-uniform heat and mass distribution, leading to outlet-temperature non-uniformity and less reliable heat delivery. This paper combines a computational fluid dynamics (CFD) model of a segmented reactor with response surface methodology (RSM)-based multi-response optimization of key design variables. Coupled heat and mass transfer in a zeolite packed bed is simulated using adsorption equilibrium and kinetic relations. A central composite design (CCD) samples the geometry space, and quadratic response-surface models are developed for energy storage density, useful recovered energy, pressure drop, average outlet temperature, outlet-temperature non-uniformity, the 95% threshold temperature, and the corresponding duration above this threshold. The surrogate models are evaluated using analysis of variance (ANOVA) and diagnostic checks. A desirability-function approach combines the seven responses into a single objective and identifies high-desirability geometries under an approximately constrained module envelope. The optimized CFD-confirmed design increased useful recovered energy by 18.28%, energy storage density by 5.21%, reduced outlet-temperature non-uniformity by 70.25%, and extended the duration above the 95% temperature threshold by 34.65%, with only a 10% increase in pressure drop. These results demonstrate that the proposed CFD–RSM framework is an efficient, reliable approach for multi-objective optimization of sorption reactors.
- 29 May 2026
- Published by TIB Open Publishing in International Sustainable Energy Conference - Proceedings
- Vol. 2
Open AccessCFD Modelling and Multi-Objective Optimization of a Segmented Open Sorption Heat Storage
Sorption heat storage offers high energy density and low thermal losses, making it attractive for short-term and seasonal solar heat storage in buildings. However, implementation depends on reactor design, particularly in terms of scalability, flow distribution, and pressure losses. Modular open-reactor designs improve scalability, while internal segmentation can reduce pressure drop by shortening the flow path. However, segmentation may also cause non-uniform heat and mass distribution, leading to outlet-temperature non-uniformity and less reliable heat delivery. This paper combines a computational fluid dynamics (CFD) model of a segmented reactor with response surface methodology (RSM)-based multi-response optimization of key design variables. Coupled heat and mass transfer in a zeolite packed bed is simulated using adsorption equilibrium and kinetic relations. A central composite design (CCD) samples the geometry space, and quadratic response-surface models are developed for energy storage density, useful recovered energy, pressure drop, average outlet temperature, outlet-temperature non-uniformity, the 95% threshold temperature, and the corresponding duration above this threshold. The surrogate models are evaluated using analysis of variance (ANOVA) and diagnostic checks. A desirability-function approach combines the seven responses into a single objective and identifies high-desirability geometries under an approximately constrained module envelope. The optimized CFD-confirmed design increased useful recovered energy by 18.28%, energy storage density by 5.21%, reduced outlet-temperature non-uniformity by 70.25%, and extended the duration above the 95% temperature threshold by 34.65%, with only a 10% increase in pressure drop. These results demonstrate that the proposed CFD–RSM framework is an efficient, reliable approach for multi-objective optimization of sorption reactors.
- Open Access
Comparative Assessment of Supervised Machine Learning Models for Predicting Water Uptake in Sorption-Based Thermal Energy Storage
In this study, supervised machine learning (ML) regression models are employed to predict water uptake during the sorption process in a sorption reactor for thermal energy storage applications. Two main methods are used to study sorption storage systems: experimental studies and numerical simulations. Experimental studies involve physical testing and measurements but are often costly and time-consuming. Numerical simulations are more flexible and cost-effective, though they can require significant computational resources for large or complex systems. To address these challenges, researchers are increasingly employing various machine learning techniques, which offer strong potential for data analysis and predictive modeling. In this study, CFD-based sorption simulations are integrated with machine learning models to predict the spatiotemporal evolution of water uptake. Several ML techniques including support vector regression (SVR), Random Forest, XGBoost, CatBoost (gradient boosting decision trees), and multilayer perceptron neural networks (MLPs) are evaluated and compared. A fixed-bed reactor equipped with fins and tubes is considered within a closed adsorption thermal storage system. Numerical simulations are conducted for three different fin lengths (10 mm, 25 mm, and 35 mm) to generate a comprehensive dataset for training the ML models and capturing the complex temporal evolution of water uptake, thereby enabling predictions for unseen fin geometries. The results indicate that neural network-based models achieve superior predictive performance compared to the other methods. For water uptake training, the mean absolute error (MAE), root mean squared error (RMSE), and coefficient of determination are approximately 2.83, 4.37, and 0.91, respectively. The predicted water uptake shows close agreement with the numerical simulation results. For the prediction cases, the MAE, MSE, and values are approximately 1.13, 1.2, and 0.8, respectively. Overall, the study demonstrates that machine learning models can accurately predict water uptake beyond the training dataset, indicating strong generalization capability and significant potential for improving thermal management system design. Additionally, the proposed approach reduces simulation time and computational cost while providing an efficient and reliable framework for modeling complex sorption processes in thermal energy storage systems.Open AccessComparative Assessment of Supervised Machine Learning Models for Predicting Water Uptake in Sorption-Based Thermal Energy Storage
In this study, supervised machine learning (ML) regression models are employed to predict water uptake during the sorption process in a sorption reactor for thermal energy storage applications. Two main methods are used to study sorption storage systems: experimental studies and numerical simulations. Experimental studies involve physical testing and measurements but are often costly and time-consuming. Numerical simulations are more flexible and cost-effective, though they can require significant computational resources for large or complex systems. To address these challenges, researchers are increasingly employing various machine learning techniques, which offer strong potential for data analysis and predictive modeling. In this study, CFD-based sorption simulations are integrated with machine learning models to predict the spatiotemporal evolution of water uptake. Several ML techniques including support vector regression (SVR), Random Forest, XGBoost, CatBoost (gradient boosting decision trees), and multilayer perceptron neural networks (MLPs) are evaluated and compared. A fixed-bed reactor equipped with fins and tubes is considered within a closed adsorption thermal storage system. Numerical simulations are conducted for three different fin lengths (10 mm, 25 mm, and 35 mm) to generate a comprehensive dataset for training the ML models and capturing the complex temporal evolution of water uptake, thereby enabling predictions for unseen fin geometries. The results indicate that neural network-based models achieve superior predictive performance compared to the other methods. For water uptake training, the mean absolute error (MAE), root mean squared error (RMSE), and coefficient of determination are approximately 2.83, 4.37, and 0.91, respectively. The predicted water uptake shows close agreement with the numerical simulation results. For the prediction cases, the MAE, MSE, and values are approximately 1.13, 1.2, and 0.8, respectively. Overall, the study demonstrates that machine learning models can accurately predict water uptake beyond the training dataset, indicating strong generalization capability and significant potential for improving thermal management system design. Additionally, the proposed approach reduces simulation time and computational cost while providing an efficient and reliable framework for modeling complex sorption processes in thermal energy storage systems. - Open Access
- 27 January 2025
- Published by Wiley in Energy Storage
- Vol. 7 (1)
Numerical Investigation of the Effect of the Mushy Zone Parameter and the Thermal Properties of Paraffin‐Based PCMs on Solidification Modeling Under T‐History Conditions
Phase change materials (PCMs) are widely used in various critical applications because of their capacity to store thermal energy and regulate temperature effectively. A review of the literature on PCM solidification and melting simulations reveals that the accuracy of these simulations is highly dependent on the input parameters and underlying assumptions used in the software. Among the key factors influencing precise simulation results are the parameter of mushy zone () and the thermal properties of the material. This study numerically investigated the impact of the and thermal properties on the solidification behavior of a paraffin in the test tube under T‐history conditions. The analysis was conducted using the commercial CFD software ANSYS Fluent and the enthalpy‐porosity method is applied to simulation the solidification process. To accurately reflect the conditions of the T‐history experiment, radiative heat transfer between surfaces was employed for the boundary conditions, ensuring a realistic representation of the experimental setup. An evaluation of four thermal properties—thermal conductivity, density, latent heat, and specific heat—indicates that while an increase in latent heat, density, and specific heat slows down the rate of solidification, an increase in thermal conductivity has the opposite effect, accelerating the solidification process. The results further emphasize that selecting an appropriate value for is crucial for achieving accurate solidification simulations. Increasing from to enhanced the prediction accuracy of the solidification time by 10%. Additionally, the mushy zone parameter significantly affects the shape and progression of solidification. As increases, solidification in the lower layers decreases, concentrating the process more in the layers adjacent to the cold wall.
- 27 January 2025
- Published by Wiley in Energy Storage
- Vol. 7 (1)
Open AccessNumerical Investigation of the Effect of the Mushy Zone Parameter and the Thermal Properties of Paraffin‐Based PCMs on Solidification Modeling Under T‐History Conditions
Phase change materials (PCMs) are widely used in various critical applications because of their capacity to store thermal energy and regulate temperature effectively. A review of the literature on PCM solidification and melting simulations reveals that the accuracy of these simulations is highly dependent on the input parameters and underlying assumptions used in the software. Among the key factors influencing precise simulation results are the parameter of mushy zone () and the thermal properties of the material. This study numerically investigated the impact of the and thermal properties on the solidification behavior of a paraffin in the test tube under T‐history conditions. The analysis was conducted using the commercial CFD software ANSYS Fluent and the enthalpy‐porosity method is applied to simulation the solidification process. To accurately reflect the conditions of the T‐history experiment, radiative heat transfer between surfaces was employed for the boundary conditions, ensuring a realistic representation of the experimental setup. An evaluation of four thermal properties—thermal conductivity, density, latent heat, and specific heat—indicates that while an increase in latent heat, density, and specific heat slows down the rate of solidification, an increase in thermal conductivity has the opposite effect, accelerating the solidification process. The results further emphasize that selecting an appropriate value for is crucial for achieving accurate solidification simulations. Increasing from to enhanced the prediction accuracy of the solidification time by 10%. Additionally, the mushy zone parameter significantly affects the shape and progression of solidification. As increases, solidification in the lower layers decreases, concentrating the process more in the layers adjacent to the cold wall.
- Open Access
Comparison of Different Numerical Models for Solidification of Paraffin-Based PCMs and Evaluation of the Effect of Variable Mushy Zone Constant
The impact of the mushy zone parameter () and the chosen numerical model during the solidification of a commercial paraffin-type phase change material (PCM) in a vertical cylinder under T-history conditions was examined through numerical simulations. The cooling process was modeled using three methods implemented in the CFD software ANSYS Fluent 2020 R2: the enthalpy–porosity method, the apparent heat capacity (AHC) method, and a new model proposed by the authors which incorporates heat capacity directly into ANSYS Fluent. To accurately define the boundary conditions, radiative heat transfer between surfaces was taken into account. Furthermore, the influence of the mushy zone parameter on the simulation accuracy and solidification rate was investigated, with the parameter being treated as a function of the liquid fraction. The results indicate that the proposed model aligns closely with experimental data regarding cooling temperature, offering better predictions compared to the other models. It was observed that temperature varies with time but not with position, suggesting that this model more effectively satisfies the lumped system condition—an essential characteristic of the T-history experiment—compared to the other methods. Additionally, the analysis showed that a higher mushy zone parameter enhances the accuracy of simulations and predicts a shorter solidification time; approximately 11% for the E-p and 7% for the AHC model. Using a variable mushy zone parameter based on the liquid fraction also produced similar results, resulting in an increased solidification rate.Open AccessComparison of Different Numerical Models for Solidification of Paraffin-Based PCMs and Evaluation of the Effect of Variable Mushy Zone Constant
The impact of the mushy zone parameter () and the chosen numerical model during the solidification of a commercial paraffin-type phase change material (PCM) in a vertical cylinder under T-history conditions was examined through numerical simulations. The cooling process was modeled using three methods implemented in the CFD software ANSYS Fluent 2020 R2: the enthalpy–porosity method, the apparent heat capacity (AHC) method, and a new model proposed by the authors which incorporates heat capacity directly into ANSYS Fluent. To accurately define the boundary conditions, radiative heat transfer between surfaces was taken into account. Furthermore, the influence of the mushy zone parameter on the simulation accuracy and solidification rate was investigated, with the parameter being treated as a function of the liquid fraction. The results indicate that the proposed model aligns closely with experimental data regarding cooling temperature, offering better predictions compared to the other models. It was observed that temperature varies with time but not with position, suggesting that this model more effectively satisfies the lumped system condition—an essential characteristic of the T-history experiment—compared to the other methods. Additionally, the analysis showed that a higher mushy zone parameter enhances the accuracy of simulations and predicts a shorter solidification time; approximately 11% for the E-p and 7% for the AHC model. Using a variable mushy zone parameter based on the liquid fraction also produced similar results, resulting in an increased solidification rate. - Open Access
- 11 November 2024
- Published by MDPI AG in Preprints.org
Comparison of Different Numerical Models for Solidification of Paraffin-Based PCMs and Evaluation of the Effect of Variable Mushy Zone Constant
The impact of the mushy zone parameter (Amushy) and the numerical model during the solidification of a commercial paraffin-type PCM in a vertical cylinder under T-history conditions was examined numerically. The cooling process was simulated using three methods implemented in the CFD code ANSYS Fluent 2020 R2: the enthalpy–porosity method, the AHC method, and a new model proposed by the authors, in which heat capacity is directly introduced into ANSYS Fluent. To determine the precise boundary conditions, radiative heat transfer between surfaces is considered. Moreover, the effect of the mushy zone parameter on simulation accuracy and solidification rate has been investigated, with a variable Amushyintroduced as a function of the liquid fraction. The results indicate that the proposed model demonstrates excellent agreement with experimental data for cooling temperature, providing a more accurate prediction than the other models. Additionally, it shows that temperature varies with time but not with position, suggesting that this model more effectively meets the lumped system condition—a key characteristic of the T-history experiment—compared to the other models. The effect of Amushyy indicates that simulations with a high mushy zone parameter are more accurate and predict a shorter solidification time. Additionally, using a variable mushy zone parameter based on liquid fraction yields similar results, leading to an increased solidification rate.
- 11 November 2024
- Published by MDPI AG in Preprints.org
Open AccessComparison of Different Numerical Models for Solidification of Paraffin-Based PCMs and Evaluation of the Effect of Variable Mushy Zone Constant
The impact of the mushy zone parameter (Amushy) and the numerical model during the solidification of a commercial paraffin-type PCM in a vertical cylinder under T-history conditions was examined numerically. The cooling process was simulated using three methods implemented in the CFD code ANSYS Fluent 2020 R2: the enthalpy–porosity method, the AHC method, and a new model proposed by the authors, in which heat capacity is directly introduced into ANSYS Fluent. To determine the precise boundary conditions, radiative heat transfer between surfaces is considered. Moreover, the effect of the mushy zone parameter on simulation accuracy and solidification rate has been investigated, with a variable Amushyintroduced as a function of the liquid fraction. The results indicate that the proposed model demonstrates excellent agreement with experimental data for cooling temperature, providing a more accurate prediction than the other models. Additionally, it shows that temperature varies with time but not with position, suggesting that this model more effectively meets the lumped system condition—a key characteristic of the T-history experiment—compared to the other models. The effect of Amushyy indicates that simulations with a high mushy zone parameter are more accurate and predict a shorter solidification time. Additionally, using a variable mushy zone parameter based on liquid fraction yields similar results, leading to an increased solidification rate.
- Open Access
- 29 October 2024
- Published by Wiley
Numerical investigation of the effect of the mushy zone parameter and the thermal properties of paraffin-based PCMs on solidification modeling under T-history conditions.
The impact of the mushy zone parameter ( A mushy ) and thermal properties during the solidification of a commercial paraffin-type PCM in a vertical cylinder under T-history conditions was examined numerically. First, the thermal properties of the paraffin-type PCM and its temperature profile during solidification under T-history conditions were experimentally obtained. The solidification process is simulated by using a numerical model and it was conducted via the commercial CFD code ANSYS FLUENT 2022. R2. The enthalpy‒porosity model was employed by the ANSYS FLUENT for solidification and melting. The accuracy of a simulation is highly sensitive to the software inputs and assumptions. Therefore, selecting the correct values for thermal properties and the mushy constant is essential for achieving precise simulation results. To determine the precise boundary conditions, radiative heat transfer between surfaces is considered. The results indicate that, between the four thermal properties, although increasing the thermal conductivity accelerates the solidification rate, the opposite effect is observed with increasing latent heat, density, and specific heat, as higher values of these properties lead to slower cooling. Moreover, the results highlight that choosing the correct mushy zone parameter is crucial for accurate solidification modeling. Although the impact of A mush on solidification is generally less pronounced because conductive heat transfer dominates compared with the melting process, for paraffin-type PCMs, a higher A mush value yields results that better align with experimental data, unlike other PCM materials. Furthermore, the shape and progression of the solidification is influenced by the mushy zone parameter and as A mushy increases, solidification in the bottom layers decreases, with the process becoming more concentrated in the layers closer to the cold wall.
- 29 October 2024
- Published by Wiley
Open AccessNumerical investigation of the effect of the mushy zone parameter and the thermal properties of paraffin-based PCMs on solidification modeling under T-history conditions.
The impact of the mushy zone parameter ( A mushy ) and thermal properties during the solidification of a commercial paraffin-type PCM in a vertical cylinder under T-history conditions was examined numerically. First, the thermal properties of the paraffin-type PCM and its temperature profile during solidification under T-history conditions were experimentally obtained. The solidification process is simulated by using a numerical model and it was conducted via the commercial CFD code ANSYS FLUENT 2022. R2. The enthalpy‒porosity model was employed by the ANSYS FLUENT for solidification and melting. The accuracy of a simulation is highly sensitive to the software inputs and assumptions. Therefore, selecting the correct values for thermal properties and the mushy constant is essential for achieving precise simulation results. To determine the precise boundary conditions, radiative heat transfer between surfaces is considered. The results indicate that, between the four thermal properties, although increasing the thermal conductivity accelerates the solidification rate, the opposite effect is observed with increasing latent heat, density, and specific heat, as higher values of these properties lead to slower cooling. Moreover, the results highlight that choosing the correct mushy zone parameter is crucial for accurate solidification modeling. Although the impact of A mush on solidification is generally less pronounced because conductive heat transfer dominates compared with the melting process, for paraffin-type PCMs, a higher A mush value yields results that better align with experimental data, unlike other PCM materials. Furthermore, the shape and progression of the solidification is influenced by the mushy zone parameter and as A mushy increases, solidification in the bottom layers decreases, with the process becoming more concentrated in the layers closer to the cold wall.
- Open Access
- 28 October 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (21) , 9840
Configurational Design of a Hybrid System Based on an Air–Water Heat Pump and Biomass Boiler for a Rural Dwelling
Hybrid energy systems combine multiple energy sources and storage technologies to enhance performance and meet diverse energy needs. Hybrid heat pump systems are particularly suitable for heating and cooling buildings in rural areas. Air-source heat pumps have two well-known disadvantages during the coldest period of the year, when the building’s heating load is at its peak: the heat pump’s capacity is reduced and it needs to perform defrost cycles. A potential solution is to size the heat pump to cover only a portion of the peak load and to use a second heat generator in a hybrid heat pump system. There is a gap in the literature regarding the configurational analysis of hybrid heat pump (HHP) systems, particularly in terms of combining heat pumps and biomass boilers, and evaluating their efficiency, economic aspects, and environmental impact. Thus, in this research, a dynamic model of a HHP system, consisting of an air-to-water heat pump paired with a biomass boiler as a backup, is presented. Various configurations of the HHP system have been developed to evaluate key performance indicators, such as efficiency, emissions, operational costs, and other relevant factors. The findings of this paper indicate that the energy performance of HHP systems is significantly affected by the system layout, heat pump size, cut-off temperature, and the control algorithm used to activate the heat generators. Moreover, series operation of HHP systems is not only more efficient than parallel operation but also results in lower emissions and reduced operation costs. As expected, the energy loss associated with defrost cycles significantly impacts the overall performance of a hybrid system based on an air-source heat pump. Finally, the impact of the cut-off temperature on the key parameters in the configuration analysis was examined, and the optimal performance of the HHP system, in terms of minimizing operational costs and emissions, was depicted using a heat map diagram.
- 28 October 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (21) , 9840
Open AccessConfigurational Design of a Hybrid System Based on an Air–Water Heat Pump and Biomass Boiler for a Rural Dwelling
Hybrid energy systems combine multiple energy sources and storage technologies to enhance performance and meet diverse energy needs. Hybrid heat pump systems are particularly suitable for heating and cooling buildings in rural areas. Air-source heat pumps have two well-known disadvantages during the coldest period of the year, when the building’s heating load is at its peak: the heat pump’s capacity is reduced and it needs to perform defrost cycles. A potential solution is to size the heat pump to cover only a portion of the peak load and to use a second heat generator in a hybrid heat pump system. There is a gap in the literature regarding the configurational analysis of hybrid heat pump (HHP) systems, particularly in terms of combining heat pumps and biomass boilers, and evaluating their efficiency, economic aspects, and environmental impact. Thus, in this research, a dynamic model of a HHP system, consisting of an air-to-water heat pump paired with a biomass boiler as a backup, is presented. Various configurations of the HHP system have been developed to evaluate key performance indicators, such as efficiency, emissions, operational costs, and other relevant factors. The findings of this paper indicate that the energy performance of HHP systems is significantly affected by the system layout, heat pump size, cut-off temperature, and the control algorithm used to activate the heat generators. Moreover, series operation of HHP systems is not only more efficient than parallel operation but also results in lower emissions and reduced operation costs. As expected, the energy loss associated with defrost cycles significantly impacts the overall performance of a hybrid system based on an air-source heat pump. Finally, the impact of the cut-off temperature on the key parameters in the configuration analysis was examined, and the optimal performance of the HHP system, in terms of minimizing operational costs and emissions, was depicted using a heat map diagram.
- 1 July 2017
- Published by Elsevier in Renewable Energy
- Vol. 107, 156-163
Experimental investigation on a solar parabolic trough collector for absorber tube filled with porous media
- 1 July 2017
- Published by Elsevier in Renewable Energy
- Vol. 107, 156-163
Experimental investigation on a solar parabolic trough collector for absorber tube filled with porous media
- 1 June 2016
- Published by Elsevier in Renewable Energy
- Vol. 91, 147-154
Heat transfer in concentrated solar air-heaters filled with a porous medium with radiation effects: A perturbation solution
- 1 June 2016
- Published by Elsevier in Renewable Energy
- Vol. 91, 147-154
Heat transfer in concentrated solar air-heaters filled with a porous medium with radiation effects: A perturbation solution