Steven J. Hammer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Steven J. Hammer has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- Grant D. Stewart
Department of Surgery, University of Cambridge, Cambridge Biomedical Campus, Cambridge, UK
7 shared publications - Wenmiao Shu
Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK
7 shared publications - Robert L. Reuben
Institute of Mechanical, Process and Energy Engineering, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, UK
6 shared publications P. Scanlan
4 shared publicationsS. Alan McNeill
Edinburgh Urological Cancer Group, Division of Pathology Laboratories, Institute of Genetics and Molecular Medicine, University of Edinburgh, Western General Hospital, Edinburgh, UK
4 shared publicationsDaniel W. Good
Edinburgh Urological Cancer Group, Division of Pathology Laboratories, Institute of Genetics and Molecular Medicine, University of Edinburgh, Western General Hospital, Edinburgh, UK
3 shared publications
Latest Publications
- Open Access
An Analysis of PCR Ct Scores and Distributions from the ONS Community Infection Survey during the COVID Second Wave in the UK
This work presents an analysis of PCR cycle threshold (Ct) scores and their distributions, i.e. the probabilities that a test is positive with a score Ct, P(Ct), derived from the survey during the second COVID wave in the UK. Their relation to gene target breakdown is exemplified. Thus a significant parameter for tracking the course of COVID in the second wave is the percentage of positive tests with Ct < 25, %Ct <25, which is obtained by plotting weekly percentiles from the survey against Ct to construct the ogive or cumulative frequency curve (CMF). The biological basis for studying this parameter is the strong correlation between %Ct < 25 and the percentage of positive tests comprising target genes ORF1ab+N and ORF1ab+N+S, or %Inf. Furthermore, the probability distributions, obtained by differentiating the ogives, were found to be predominantly bimodal with a hot peak at Ct = 20.31+/- 4.65 and a cold peak with Ct = 32.95+/-1.11. These closely match the peaks found for the target genes ORF1ab+N, viz. Ct=18.54+/-2.31 and Ct=32.02+/-0.49 as well as in Walker et al [12]. Similar results were found in [13] and [14]. The cold peak seems likely to be associated with residue from a previous infection. The distributions for gene targets in cfvroc Pillar 2 [15,16] are also bimodal but the peaks occur at lower values of Ct. This suggests the results are machine/sample dependent and emphasises the need for calibration, if quality control in PCR testing is to be improved.
Open AccessAn Analysis of PCR Ct Scores and Distributions from the ONS Community Infection Survey during the COVID Second Wave in the UK
This work presents an analysis of PCR cycle threshold (Ct) scores and their distributions, i.e. the probabilities that a test is positive with a score Ct, P(Ct), derived from the survey during the second COVID wave in the UK. Their relation to gene target breakdown is exemplified. Thus a significant parameter for tracking the course of COVID in the second wave is the percentage of positive tests with Ct < 25, %Ct <25, which is obtained by plotting weekly percentiles from the survey against Ct to construct the ogive or cumulative frequency curve (CMF). The biological basis for studying this parameter is the strong correlation between %Ct < 25 and the percentage of positive tests comprising target genes ORF1ab+N and ORF1ab+N+S, or %Inf. Furthermore, the probability distributions, obtained by differentiating the ogives, were found to be predominantly bimodal with a hot peak at Ct = 20.31+/- 4.65 and a cold peak with Ct = 32.95+/-1.11. These closely match the peaks found for the target genes ORF1ab+N, viz. Ct=18.54+/-2.31 and Ct=32.02+/-0.49 as well as in Walker et al [12]. Similar results were found in [13] and [14]. The cold peak seems likely to be associated with residue from a previous infection. The distributions for gene targets in cfvroc Pillar 2 [15,16] are also bimodal but the peaks occur at lower values of Ct. This suggests the results are machine/sample dependent and emphasises the need for calibration, if quality control in PCR testing is to be improved.
- Open Access
- 21 April 2022
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 26 (4) , 383-398
Locating and sizing tumor nodules in human prostate using instrumented probing – computational framework and experimental validation
Detection of tumor nodules is key to early cancer diagnosis. This study investigates the potential of using the mechanical data, acquired from probing the prostate for detecting the existence, and, more importantly, characterizing the size and depth, from the posterior surface, of the prostate cancer (PCa) nodules. A computational approach is developed to quantify the uncertainty of nodule detectability and is based on identifying stiffness anomalies in the profiles of point force measurements across transverse sections of the prostate. The capability of the proposed method was assessed firstly using a ‘training’ dataset of in silico models including PCa nodules with random size, depth and location, followed by a clinical feasibility study, involving experimental data from 13 ex vivo prostates from patients who had undergone radical prostatatectomy. Promising levels of sensitivity and specificity were obtained for detecting the PCa nodules in a total of 44 prostate sections. This study has shown that the proposed methods could be a useful complementary tool to exisiting diagnostic methods of PCa. The future study will involve implementing the proposed measurement and detection strategies in vivo, with the help of a miniturized medical device.
- 21 April 2022
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 26 (4) , 383-398
Open AccessLocating and sizing tumor nodules in human prostate using instrumented probing – computational framework and experimental validation
Detection of tumor nodules is key to early cancer diagnosis. This study investigates the potential of using the mechanical data, acquired from probing the prostate for detecting the existence, and, more importantly, characterizing the size and depth, from the posterior surface, of the prostate cancer (PCa) nodules. A computational approach is developed to quantify the uncertainty of nodule detectability and is based on identifying stiffness anomalies in the profiles of point force measurements across transverse sections of the prostate. The capability of the proposed method was assessed firstly using a ‘training’ dataset of in silico models including PCa nodules with random size, depth and location, followed by a clinical feasibility study, involving experimental data from 13 ex vivo prostates from patients who had undergone radical prostatatectomy. Promising levels of sensitivity and specificity were obtained for detecting the PCa nodules in a total of 44 prostate sections. This study has shown that the proposed methods could be a useful complementary tool to exisiting diagnostic methods of PCa. The future study will involve implementing the proposed measurement and detection strategies in vivo, with the help of a miniturized medical device.
- 30 September 2017
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 231 (12) , 1081-1100
Quantitative mechanical assessment of the whole prostate gland ex vivo using dynamic instrumented palpation
An instrumented palpation sensor, designed for measuring the dynamic modulus of tissue in vivo, has been developed and trialled on ex vivo whole prostate glands. The sensor consists of a flexible membrane sensor/actuator with an embedded strain gauge and is actuated using a dynamically varying airflow at frequencies of 1 and 5 Hz. The device was calibrated using an indentation stiffness measurement rig and gelatine samples with a range of static modulus similar to that reported in the literature for prostate tissue. The glands were removed from patients with diagnosed prostate cancer scheduled for radical prostatectomy, and the stiffness was measured within 30 min of surgical removal. Each prostate was later examined histologically in a column immediately below each indentation point and graded into one of the four groups; normal, benign prostatic hyperplasia, cancerous and mixed cancer and benign prostatic hyperplasia. In total, 11 prostates were assessed using multiple point probing, and the complex modulus at 1 and 5 Hz was calculated on a point-by-point basis. The device yielded values of quasi-static modulus of 15 ± 0.5 kPa and dynamic modulus of 20 ± 0.5 kPa for whole prostates, and a sensitivity of up to 80% with slightly lower specificity was achieved on diagnosis of prostate cancer using a combination of mechanical measures. This assessment did not take into account some obvious factors such as edge effects, overlap and clinical significance of the cancer, all of which would improve performance. The device, as currently configured, is immediately deployable in vivo. A number of improvements are also identified which could improve the sensitivity and specificity in future embodiments of the probe.
- 30 September 2017
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 231 (12) , 1081-1100
Quantitative mechanical assessment of the whole prostate gland ex vivo using dynamic instrumented palpation
An instrumented palpation sensor, designed for measuring the dynamic modulus of tissue in vivo, has been developed and trialled on ex vivo whole prostate glands. The sensor consists of a flexible membrane sensor/actuator with an embedded strain gauge and is actuated using a dynamically varying airflow at frequencies of 1 and 5 Hz. The device was calibrated using an indentation stiffness measurement rig and gelatine samples with a range of static modulus similar to that reported in the literature for prostate tissue. The glands were removed from patients with diagnosed prostate cancer scheduled for radical prostatectomy, and the stiffness was measured within 30 min of surgical removal. Each prostate was later examined histologically in a column immediately below each indentation point and graded into one of the four groups; normal, benign prostatic hyperplasia, cancerous and mixed cancer and benign prostatic hyperplasia. In total, 11 prostates were assessed using multiple point probing, and the complex modulus at 1 and 5 Hz was calculated on a point-by-point basis. The device yielded values of quasi-static modulus of 15 ± 0.5 kPa and dynamic modulus of 20 ± 0.5 kPa for whole prostates, and a sensitivity of up to 80% with slightly lower specificity was achieved on diagnosis of prostate cancer using a combination of mechanical measures. This assessment did not take into account some obvious factors such as edge effects, overlap and clinical significance of the cancer, all of which would improve performance. The device, as currently configured, is immediately deployable in vivo. A number of improvements are also identified which could improve the sensitivity and specificity in future embodiments of the probe.
- 1 March 2016
- Published by Elsevier in European Urology Supplements
- Vol. 15 (3) , e390
390 Micromechanical biomarkers are superior to conventional DRE and TRUS biopsy in the detection of prostate cancer
- 1 March 2016
- Published by Elsevier in European Urology Supplements
- Vol. 15 (3) , e390
390 Micromechanical biomarkers are superior to conventional DRE and TRUS biopsy in the detection of prostate cancer
- Open Access
- 16 July 2015
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 32 (1) , e02734
Patient specific modeling of palpation‐based prostate cancer diagnosis: effects of pelvic cavity anatomy and intrabladder pressure
Summary: Computational modeling has become a successful tool for scientific advances including understanding the behavior of biological and biomedical systems as well as improving clinical practice. In most cases, only general models are used without taking into account patient‐specific features. However, patient specificity has proven to be crucial in guiding clinical practice because of disastrous consequences that can arise should the model be inaccurate. This paper proposes a framework for the computational modeling applied to the example of the male pelvic cavity for the purpose of prostate cancer diagnostics using palpation. The effects of patient specific structural features on palpation response are studied in three selected patients with very different pathophysiological conditions whose pelvic cavities are reconstructed from MRI scans. In particular, the role of intrabladder pressure in the outcome of digital rectal examination is investigated with the objective of providing guidelines to practitioners to enhance the effectiveness of diagnosis. Furthermore, the presence of the pelvic bone in the model is assessed to determine the pathophysiological conditions in which it has to be modeled. The conclusions and suggestions of this work have potential use not only in clinical practice and also for biomechanical modeling where structural patient‐specificity needs to be considered. © 2015 The Authors. International Journal for Numerical Methods in Biomedical Engineering published by John Wiley & Sons Ltd.
- 16 July 2015
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 32 (1) , e02734
Open AccessPatient specific modeling of palpation‐based prostate cancer diagnosis: effects of pelvic cavity anatomy and intrabladder pressure
Summary: Computational modeling has become a successful tool for scientific advances including understanding the behavior of biological and biomedical systems as well as improving clinical practice. In most cases, only general models are used without taking into account patient‐specific features. However, patient specificity has proven to be crucial in guiding clinical practice because of disastrous consequences that can arise should the model be inaccurate. This paper proposes a framework for the computational modeling applied to the example of the male pelvic cavity for the purpose of prostate cancer diagnostics using palpation. The effects of patient specific structural features on palpation response are studied in three selected patients with very different pathophysiological conditions whose pelvic cavities are reconstructed from MRI scans. In particular, the role of intrabladder pressure in the outcome of digital rectal examination is investigated with the objective of providing guidelines to practitioners to enhance the effectiveness of diagnosis. Furthermore, the presence of the pelvic bone in the model is assessed to determine the pathophysiological conditions in which it has to be modeled. The conclusions and suggestions of this work have potential use not only in clinical practice and also for biomechanical modeling where structural patient‐specificity needs to be considered. © 2015 The Authors. International Journal for Numerical Methods in Biomedical Engineering published by John Wiley & Sons Ltd.
- 23 June 2015
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 232, 310-318
Development of a novel actuator for the dynamic palpation of soft tissue for use in the assessment of prostate tissue quality
- 23 June 2015
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 232, 310-318
Development of a novel actuator for the dynamic palpation of soft tissue for use in the assessment of prostate tissue quality
- Open Access
- 1 April 2015
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 225, 53-60
An optical fibre dynamic instrumented palpation sensor for the characterisation of biological tissue
- 1 April 2015
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 225, 53-60
Open AccessAn optical fibre dynamic instrumented palpation sensor for the characterisation of biological tissue
- Open Access
- 1 January 2015
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 41, 149-160
Quantitative diagnostics of soft tissue through viscoelastic characterization using time-based instrumented palpation
- 1 January 2015
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 41, 149-160
Open AccessQuantitative diagnostics of soft tissue through viscoelastic characterization using time-based instrumented palpation
- Open Access
- 31 December 2014
- Published by Elsevier in Procedia Engineering
- Vol. 87, 656-659
A Scalable Actuator for the Dynamic Palpation of Soft Tissue for Use in the Assessment of Prostate Tissue Quality
- 31 December 2014
- Published by Elsevier in Procedia Engineering
- Vol. 87, 656-659
Open AccessA Scalable Actuator for the Dynamic Palpation of Soft Tissue for Use in the Assessment of Prostate Tissue Quality
- Open Access
- 10 November 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (11) , e112872
Tissue Quality Assessment Using a Novel Direct Elasticity Assessment Device (The E-Finger): A Cadaveric Study of Prostatectomy Dissection
Minimally invasive radical prostatectomy (RP) (robotic and laparoscopic), have brought improvements in the outcomes of RP due to improved views and increased degrees of freedom of surgical devices. Robotic and laparoscopic surgeries do not incorporate haptic feedback, which may result in complications secondary to inadequate tissue dissection (causing positive surgical margins, rhabdosphincter damage, etc). We developed a micro-engineered device (6 mm2 sized) [E-finger]) capable of quantitative elasticity assessment, with amplitude ratio, mean ratio and phase lag representing this. The aim was to assess the utility of the device in differentiating peri-prostatic tissue types in order to guide prostate dissection. Two embalmed and 2 fresh frozen cadavers were used in the study. Baseline elasticity values were assessed in bladder, prostate and rhabdosphincter of pre-dissected embalmed cadavers using the micro-engineered device. A measurement grid was created to span from the bladder, across the prostate and onto the rhabdosphincter of fresh frozen cadavers to enable a systematic quantitative elasticity assessment of the entire area by 2 independent assessors. Tissue was sectioned along each row of elasticity measurement points, and stained with haematoxylin and eosin (H&E). Image analysis was performed with Image Pro Premier to determine the histology at each measurement point. Statistically significant differences in elasticity were identified between bladder, prostate and sphincter in both embalmed and fresh frozen cadavers (p = 2. This cadaveric study has evaluated the ability of our elasticity assessment device to differentiate bladder, prostate and rhabdosphincter to a resolution of 6 mm2. The results provide useful data for which to continue to examine the use of elasticity assessment devices for tissue quality assessment with the aim of giving haptic feedback to surgeons performing complex surgery.
- 10 November 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (11) , e112872
Open AccessTissue Quality Assessment Using a Novel Direct Elasticity Assessment Device (The E-Finger): A Cadaveric Study of Prostatectomy Dissection
Minimally invasive radical prostatectomy (RP) (robotic and laparoscopic), have brought improvements in the outcomes of RP due to improved views and increased degrees of freedom of surgical devices. Robotic and laparoscopic surgeries do not incorporate haptic feedback, which may result in complications secondary to inadequate tissue dissection (causing positive surgical margins, rhabdosphincter damage, etc). We developed a micro-engineered device (6 mm2 sized) [E-finger]) capable of quantitative elasticity assessment, with amplitude ratio, mean ratio and phase lag representing this. The aim was to assess the utility of the device in differentiating peri-prostatic tissue types in order to guide prostate dissection. Two embalmed and 2 fresh frozen cadavers were used in the study. Baseline elasticity values were assessed in bladder, prostate and rhabdosphincter of pre-dissected embalmed cadavers using the micro-engineered device. A measurement grid was created to span from the bladder, across the prostate and onto the rhabdosphincter of fresh frozen cadavers to enable a systematic quantitative elasticity assessment of the entire area by 2 independent assessors. Tissue was sectioned along each row of elasticity measurement points, and stained with haematoxylin and eosin (H&E). Image analysis was performed with Image Pro Premier to determine the histology at each measurement point. Statistically significant differences in elasticity were identified between bladder, prostate and sphincter in both embalmed and fresh frozen cadavers (p = 2. This cadaveric study has evaluated the ability of our elasticity assessment device to differentiate bladder, prostate and rhabdosphincter to a resolution of 6 mm2. The results provide useful data for which to continue to examine the use of elasticity assessment devices for tissue quality assessment with the aim of giving haptic feedback to surgeons performing complex surgery.