Hans-Jürgen Koß
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hans-Jürgen Koß has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Thorsten Brands
RWTH Aachen University
11 shared publications - André Bardow
Energy & Process Systems Engineering, Department of Mechanical and Process Engineering, ETH Zurich, Zürich, Switzerland
10 shared publications Stefan Pischinger
7 shared publications- Christof Schulz
University of Duisburg-Essen
4 shared publications - Ludger Wolff
Institute of Technical Thermodynamics , RWTH Aachen University , 52056 Aachen , Germany
4 shared publications - Wolfgang Marquardt
RWTH Aachen University
4 shared publications
Latest Publications
- 5 June 2026
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 164 (21)
Improved ab initio molecular dynamics–based vibrational spectroscopy for indirect hard modeling for bulk-phase vibrational spectroscopy using vibrational scaling and sampling diagnostics
Ab initio molecular dynamics (AIMD)-derived vibrational spectra provide a promising route toward calibration-free quantitative spectroscopy when combined with indirect hard modeling (IHM). Reliability of AIMD-based spectra for bulk-phase can be compromised by incomplete sampling, electronic-structure errors, and frequency shifts relative to experiment. In this work, an improved AIMD–IHM framework is presented that addresses these limitations through benchmarking comparison of the BLYP and B3LYP/ADMM functional methods to assess their relative accuracy, cluster-resolved sampling analysis based on hydrogen-bond kinetics, and a gas-phase-anchored vibrational frequency scaling strategy. The methodology is demonstrated for aqueous acetic acid, a strongly hydrogen-bonded system characterized by transient molecular associations and proton-sharing motifs. Raman spectra generated from bulk-phase AIMD simulations using BLYP and B3LYP/ADMM are benchmarked against experiment, revealing that the computationally efficient BLYP functional outperforms B3LYP/ADMM in reproducing experimental vibrational frequencies, with a root mean square error (RMSE) of 91 cm−1 compared to 155 cm−1 for the volumetric fraction of 0.2. A region-specific scaling procedure derived from gas-phase data significantly reduces the RMSE of BLYP-based bulk-phase spectra. Hydrogen-bond cluster analysis via reactive-flux indicates that the AIMD trajectories are sufficiently sampled for all relevant molecular motifs and provide quantitative evidence that the spectra are unlikely to be biased by undersampling. When integrated into IHM, the scaled AIMD-derived spectra determine experimental mixture compositions with an RMSE of 0.021 without any experimental calibration, representing an improvement over unscaled spectra, which showed an RMSE of 0.034. The proposed framework enhances the predictive accuracy of AIMD–IHM and extends its applicability to strongly interacting liquid systems.
- 5 June 2026
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 164 (21)
Improved ab initio molecular dynamics–based vibrational spectroscopy for indirect hard modeling for bulk-phase vibrational spectroscopy using vibrational scaling and sampling diagnostics
Ab initio molecular dynamics (AIMD)-derived vibrational spectra provide a promising route toward calibration-free quantitative spectroscopy when combined with indirect hard modeling (IHM). Reliability of AIMD-based spectra for bulk-phase can be compromised by incomplete sampling, electronic-structure errors, and frequency shifts relative to experiment. In this work, an improved AIMD–IHM framework is presented that addresses these limitations through benchmarking comparison of the BLYP and B3LYP/ADMM functional methods to assess their relative accuracy, cluster-resolved sampling analysis based on hydrogen-bond kinetics, and a gas-phase-anchored vibrational frequency scaling strategy. The methodology is demonstrated for aqueous acetic acid, a strongly hydrogen-bonded system characterized by transient molecular associations and proton-sharing motifs. Raman spectra generated from bulk-phase AIMD simulations using BLYP and B3LYP/ADMM are benchmarked against experiment, revealing that the computationally efficient BLYP functional outperforms B3LYP/ADMM in reproducing experimental vibrational frequencies, with a root mean square error (RMSE) of 91 cm−1 compared to 155 cm−1 for the volumetric fraction of 0.2. A region-specific scaling procedure derived from gas-phase data significantly reduces the RMSE of BLYP-based bulk-phase spectra. Hydrogen-bond cluster analysis via reactive-flux indicates that the AIMD trajectories are sufficiently sampled for all relevant molecular motifs and provide quantitative evidence that the spectra are unlikely to be biased by undersampling. When integrated into IHM, the scaled AIMD-derived spectra determine experimental mixture compositions with an RMSE of 0.021 without any experimental calibration, representing an improvement over unscaled spectra, which showed an RMSE of 0.034. The proposed framework enhances the predictive accuracy of AIMD–IHM and extends its applicability to strongly interacting liquid systems.
- Open Access
- 21 December 2023
- Published by Springer Nature in Communications Chemistry
- Vol. 6 (1) , 1
Author Correction: Interdisciplinary development of an overall process concept from glucose to 4,5-dimethyl-1,3-dioxolane via 2,3-butanediol
- 21 December 2023
- Published by Springer Nature in Communications Chemistry
- Vol. 6 (1) , 1
Open AccessAuthor Correction: Interdisciplinary development of an overall process concept from glucose to 4,5-dimethyl-1,3-dioxolane via 2,3-butanediol
- Open Access
- 20 November 2023
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 415 (29-30) , 7247-7258
The Good pH probe: non-invasive pH in-line monitoring using Good buffers and Raman spectroscopy
In bioprocesses, the pH value is a critical process parameter that requires monitoring and control. For pH monitoring, potentiometric methods such as pH electrodes are state of the art. However, they are invasive and show measurement value drift. Spectroscopic pH monitoring is a non-invasive alternative to potentiometric methods avoiding this measurement value drift. In this study, we developed the Good pH probe, which is an approach for spectroscopic pH monitoring in bioprocesses with an effective working range between pH 6 and pH 8 that does not require the estimation of activity coefficients. The Good pH probe combines for the first time the Good buffer 3-(N-morpholino)propanesulfonic acid (MOPS) as pH indicator with Raman spectroscopy as spectroscopic technique, and Indirect Hard Modeling (IHM) for the spectral evaluation. During a detailed characterization, we proved that the Good pH probe is reversible, exhibits no temperature dependence between 15 and 40 °C, has low sensitivity to the ionic strength up to 1100 mM, and is applicable in more complex systems, in which other components significantly superimpose the spectral features of MOPS. Finally, the Good pH probe was successfully used for non-invasive pH in-line monitoring during an industrially relevant enzyme-catalyzed reaction with a root mean square error of prediction (RMSEP) of 0.04 pH levels. Thus, the Good pH probe extends the list of critical process parameters monitorable using Raman spectroscopy and IHM by the pH value. Graphical abstract
- 20 November 2023
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 415 (29-30) , 7247-7258
Open AccessThe Good pH probe: non-invasive pH in-line monitoring using Good buffers and Raman spectroscopy
In bioprocesses, the pH value is a critical process parameter that requires monitoring and control. For pH monitoring, potentiometric methods such as pH electrodes are state of the art. However, they are invasive and show measurement value drift. Spectroscopic pH monitoring is a non-invasive alternative to potentiometric methods avoiding this measurement value drift. In this study, we developed the Good pH probe, which is an approach for spectroscopic pH monitoring in bioprocesses with an effective working range between pH 6 and pH 8 that does not require the estimation of activity coefficients. The Good pH probe combines for the first time the Good buffer 3-(N-morpholino)propanesulfonic acid (MOPS) as pH indicator with Raman spectroscopy as spectroscopic technique, and Indirect Hard Modeling (IHM) for the spectral evaluation. During a detailed characterization, we proved that the Good pH probe is reversible, exhibits no temperature dependence between 15 and 40 °C, has low sensitivity to the ionic strength up to 1100 mM, and is applicable in more complex systems, in which other components significantly superimpose the spectral features of MOPS. Finally, the Good pH probe was successfully used for non-invasive pH in-line monitoring during an industrially relevant enzyme-catalyzed reaction with a root mean square error of prediction (RMSEP) of 0.04 pH levels. Thus, the Good pH probe extends the list of critical process parameters monitorable using Raman spectroscopy and IHM by the pH value. Graphical abstract
- Open Access
- 16 November 2023
- Published by Springer Nature in Communications Chemistry
- Vol. 6 (1) , 1-11
Interdisciplinary development of an overall process concept from glucose to 4,5-dimethyl-1,3-dioxolane via 2,3-butanediol
To reduce carbon dioxide emissions, carbon-neutral fuels have recently gained renewed attention. Here we show the development and evaluation of process routes for the production of such a fuel, the cyclic acetal 4,5-dimethyl-1,3-dioxolane, from glucose via 2,3-butanediol. The selected process routes are based on the sequential use of microbes, enzymes and chemo-catalysts in order to exploit the full potential of the different catalyst systems through a tailor-made combination. The catalysts (microbes, enzymes, chemo-catalysts) and the reaction medium selected for each conversion step are key factors in the development of the respective production methods. The production of the intermediate 2,3-butanediol by combined microbial and enzyme catalysis is compared to the conventional microbial route from glucose in terms of specific energy demand and overall yield, with the conventional route remaining more efficient. In order to be competitive with current 2,3-butanediol production, the key performance indicator, enzyme stability to high aldehyde concentrations, needs to be increased. The target value for the enzyme stability is an acetaldehyde concentration of 600 mM, which is higher than the current maximum concentration (200 mM) by a factor of three.
- 16 November 2023
- Published by Springer Nature in Communications Chemistry
- Vol. 6 (1) , 1-11
Open AccessInterdisciplinary development of an overall process concept from glucose to 4,5-dimethyl-1,3-dioxolane via 2,3-butanediol
To reduce carbon dioxide emissions, carbon-neutral fuels have recently gained renewed attention. Here we show the development and evaluation of process routes for the production of such a fuel, the cyclic acetal 4,5-dimethyl-1,3-dioxolane, from glucose via 2,3-butanediol. The selected process routes are based on the sequential use of microbes, enzymes and chemo-catalysts in order to exploit the full potential of the different catalyst systems through a tailor-made combination. The catalysts (microbes, enzymes, chemo-catalysts) and the reaction medium selected for each conversion step are key factors in the development of the respective production methods. The production of the intermediate 2,3-butanediol by combined microbial and enzyme catalysis is compared to the conventional microbial route from glucose in terms of specific energy demand and overall yield, with the conventional route remaining more efficient. In order to be competitive with current 2,3-butanediol production, the key performance indicator, enzyme stability to high aldehyde concentrations, needs to be increased. The target value for the enzyme stability is an acetaldehyde concentration of 600 mM, which is higher than the current maximum concentration (200 mM) by a factor of three.
- 1 August 2019
- Published by Elsevier in Combustion and Flame
- Vol. 206, 201-210
Fuel effects on NO formation in diesel-like jets in a vessel
- 1 August 2019
- Published by Elsevier in Combustion and Flame
- Vol. 206, 201-210
Fuel effects on NO formation in diesel-like jets in a vessel
- 10 October 2018
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 39 (12) , 132
Concentration-Dependent Diffusion Coefficients of Binary Gas Mixtures Using a Loschmidt Cell with Holographic Interferometry
- 10 October 2018
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 39 (12) , 132
Concentration-Dependent Diffusion Coefficients of Binary Gas Mixtures Using a Loschmidt Cell with Holographic Interferometry
- 10 October 2018
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 39 (12) , 133
Concentration-Dependent Diffusion Coefficients of Binary Gas Mixtures Using a Loschmidt Cell with Holographic Interferometry
- 10 October 2018
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 39 (12) , 133
Concentration-Dependent Diffusion Coefficients of Binary Gas Mixtures Using a Loschmidt Cell with Holographic Interferometry
- 1 February 2018
- Published by Elsevier in Combustion and Flame
- Vol. 188, 250-261
Quantitative nitrogen oxide measurements by laser-induced fluorescence in diesel-like n-heptane jets with enhanced premixing
- 1 February 2018
- Published by Elsevier in Combustion and Flame
- Vol. 188, 250-261
Quantitative nitrogen oxide measurements by laser-induced fluorescence in diesel-like n-heptane jets with enhanced premixing
- 1 January 2018
- Published by Elsevier in Chemometrics and Intelligent Laboratory Systems
- Vol. 172, 1-9
Robust analysis of spectra with strong background signals by First-Derivative Indirect Hard Modeling (FD-IHM)
- 1 January 2018
- Published by Elsevier in Chemometrics and Intelligent Laboratory Systems
- Vol. 172, 1-9
Robust analysis of spectra with strong background signals by First-Derivative Indirect Hard Modeling (FD-IHM)