Ryan P. McNabb
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ryan P. McNabb has a total of 108 co-authors. Here are the top co-authors by number of shared publications:
Anthony N. Kuo
Duke University Medical Center
19 shared publicationsJoseph A. Izatt
Duke University Medical Center
18 shared publications- Mark Draelos
University of Michigan
8 shared publications - Sina Farsiu
Duke University
5 shared publications - Amit Narawane
Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA
4 shared publications - Joseph A. Izatt
Department of Biomedical Engineering, Duke University, Durham, NC, USA
4 shared publications
Latest Publications
- 8 October 2026
- Published by Optica Publishing Group in Optica
- Vol. 13 (10) , 2144
Synthetic training enables markerless 3D instrument tracking for intraoperative optical coherence tomography
This work experimentally demonstrates automatic optical 3D tracking of target areas of interest within wide-field digital stereoscope imagery to guide high-resolution intraoperative optical coherence tomography (iOCT) acquisition in real time. Eye surgeries such as cataract surgery are among the most commonly performed surgeries in the world and require precise visualization, especially in the axial dimension. By enabling unparalleled axial sensitivity, iOCT has emerged as a leading modality to enhance surgical visualization of the eye. However, current iOCT visualization of ophthalmic surgeries is limited by the small field of view (FOV) of OCT relative to that of the surgical microscope, requiring extensive manual realignment by a trained operator. We have developed an iOCT computer vision system that utilizes the built-in stereo microscope video feed to automatically align the OCT volume with the surgeon’s tool tip in 3D, tracking over a wide FOV and without modifications to surgical tools. Furthermore, our system used a deep-learning detection model trained on a novel synthetic microscope image generation pipeline and annotated real images to create what is believed to be a new 3D tracking system that is both fast and accurate. We integrated this tracking system into a high-speed iOCT stereo microscope to acquire 3D tool-tip-aligned OCT volumes in real time. We demonstrated successful tracking performance by consistently positioning the iOCT volume ( x =5mm, y =5mm, and z =7mm) at the tool tip ( x =0.72±0.44mm, y =0.78±0.47mm, and z =2.07±1.43mm error) in testing with a motorized three-axis stage and by simulating ex vivo porcine eye cataract maneuvers with real surgical instruments. Our synthetic eye dataset pipeline and iOCT tracking system pave the way for more effective and usable visualization in eye surgery.
- 8 October 2026
- Published by Optica Publishing Group in Optica
- Vol. 13 (10) , 2144
Synthetic training enables markerless 3D instrument tracking for intraoperative optical coherence tomography
This work experimentally demonstrates automatic optical 3D tracking of target areas of interest within wide-field digital stereoscope imagery to guide high-resolution intraoperative optical coherence tomography (iOCT) acquisition in real time. Eye surgeries such as cataract surgery are among the most commonly performed surgeries in the world and require precise visualization, especially in the axial dimension. By enabling unparalleled axial sensitivity, iOCT has emerged as a leading modality to enhance surgical visualization of the eye. However, current iOCT visualization of ophthalmic surgeries is limited by the small field of view (FOV) of OCT relative to that of the surgical microscope, requiring extensive manual realignment by a trained operator. We have developed an iOCT computer vision system that utilizes the built-in stereo microscope video feed to automatically align the OCT volume with the surgeon’s tool tip in 3D, tracking over a wide FOV and without modifications to surgical tools. Furthermore, our system used a deep-learning detection model trained on a novel synthetic microscope image generation pipeline and annotated real images to create what is believed to be a new 3D tracking system that is both fast and accurate. We integrated this tracking system into a high-speed iOCT stereo microscope to acquire 3D tool-tip-aligned OCT volumes in real time. We demonstrated successful tracking performance by consistently positioning the iOCT volume ( x =5mm, y =5mm, and z =7mm) at the tool tip ( x =0.72±0.44mm, y =0.78±0.47mm, and z =2.07±1.43mm error) in testing with a motorized three-axis stage and by simulating ex vivo porcine eye cataract maneuvers with real surgical instruments. Our synthetic eye dataset pipeline and iOCT tracking system pave the way for more effective and usable visualization in eye surgery.
- 25 August 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (9) , 4741
Motion-corrected Gaussian, mean, and parametric curvature mapping of the posterior eye with pupil-tracked whole-eye OCT
Optical coherence tomography (OCT) is a promising alternative to magnetic resonance imaging (MRI) for accessible, high-resolution measurement of posterior eye curvature, including for applications such as exploration of local eye shape deformations in pathologic myopia. However, OCT is a point-scanning interferometric imaging method that spatially encodes the effects of patient motion during acquisition into an acquired volume. These motion artifacts reduce accuracy and increase intra-acquisition variation in measured curvature, reducing the utility of OCT for monitoring posterior eye curvatures longitudinally. We present a method utilizing 3D pupil tracking and sparse orthogonal scanning for post-acquisition correction of motion artifacts in posterior eye OCT volumes and their corresponding curvature maps. We imaged six subjects exhibiting moderate (−6.0 to −3.0 D) to high (<−6.0 D) myopia and demonstrate a reduction in intra-session curvature variability when using our pupil tracking motion correction scheme. We also propose alternative metrics for representing 2-dimensional posterior eye curvature data to researchers and clinicians.
- 25 August 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (9) , 4741
Motion-corrected Gaussian, mean, and parametric curvature mapping of the posterior eye with pupil-tracked whole-eye OCT
Optical coherence tomography (OCT) is a promising alternative to magnetic resonance imaging (MRI) for accessible, high-resolution measurement of posterior eye curvature, including for applications such as exploration of local eye shape deformations in pathologic myopia. However, OCT is a point-scanning interferometric imaging method that spatially encodes the effects of patient motion during acquisition into an acquired volume. These motion artifacts reduce accuracy and increase intra-acquisition variation in measured curvature, reducing the utility of OCT for monitoring posterior eye curvatures longitudinally. We present a method utilizing 3D pupil tracking and sparse orthogonal scanning for post-acquisition correction of motion artifacts in posterior eye OCT volumes and their corresponding curvature maps. We imaged six subjects exhibiting moderate (−6.0 to −3.0 D) to high (<−6.0 D) myopia and demonstrate a reduction in intra-session curvature variability when using our pupil tracking motion correction scheme. We also propose alternative metrics for representing 2-dimensional posterior eye curvature data to researchers and clinicians.
- Open Access
- 22 July 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (12) , 1-16
Autonomous robotic alignment and dynamic illumination control of an ophthalmic slit lamp for in vivo anterior segment imaging
SignificanceThe slit lamp is the gold standard ophthalmic instrument for examining the anterior segment of the eye. Slit lamps require the mechanical stabilization of patients to facilitate alignment and a specialized technician to operate. The growing demand for ophthalmic care and shortages of specialists highlight the need for alternative diagnostic technologies.AimWe demonstrate an autonomously aligning, contactless slit lamp enabled by a vision-guided robot to acquire anterior segment images without mechanical patient stabilization.ApproachWe integrate three subsystems mounted to a collaborative robot arm: a custom optical system for dynamic slit illumination, vision-based sensors, and color cameras. A hierarchical control strategy is employed to maintain alignment. Programmable illumination patterns are projected onto the cornea to replicate slit-lamp examination maneuvers.ResultsThe device autonomously aligned to the eyes of in vivo human subjects, and we collected color images of the anterior segment during alignment. Dynamic slit illumination compensated for motion with a latency of 86 ms, allowing slit alignment to be maintained during imaging without mechanical stabilization.ConclusionsThese results demonstrate the feasibility of autonomous, contactless slit-lamp imaging through the use of robotic alignment and dynamic illumination. Such advancements could expand access to anterior segment diagnostic imaging.
- 22 July 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (12) , 1-16
Open AccessAutonomous robotic alignment and dynamic illumination control of an ophthalmic slit lamp for in vivo anterior segment imaging
SignificanceThe slit lamp is the gold standard ophthalmic instrument for examining the anterior segment of the eye. Slit lamps require the mechanical stabilization of patients to facilitate alignment and a specialized technician to operate. The growing demand for ophthalmic care and shortages of specialists highlight the need for alternative diagnostic technologies.AimWe demonstrate an autonomously aligning, contactless slit lamp enabled by a vision-guided robot to acquire anterior segment images without mechanical patient stabilization.ApproachWe integrate three subsystems mounted to a collaborative robot arm: a custom optical system for dynamic slit illumination, vision-based sensors, and color cameras. A hierarchical control strategy is employed to maintain alignment. Programmable illumination patterns are projected onto the cornea to replicate slit-lamp examination maneuvers.ResultsThe device autonomously aligned to the eyes of in vivo human subjects, and we collected color images of the anterior segment during alignment. Dynamic slit illumination compensated for motion with a latency of 86 ms, allowing slit alignment to be maintained during imaging without mechanical stabilization.ConclusionsThese results demonstrate the feasibility of autonomous, contactless slit-lamp imaging through the use of robotic alignment and dynamic illumination. Such advancements could expand access to anterior segment diagnostic imaging.
- 24 June 2026
- Published by Optica Publishing Group in Optics Continuum
- Vol. 5 (7) , 2096-2103
Size estimation of mixed free-floating sub-resolution spherical scatterers utilizing adaptive scanning optical coherence tomography
Optical coherence tomography (OCT) is a volumetric imaging technique that enables real-time assessment of biological tissues with micrometer-scale resolution. This enables OCT to also offer the potential to estimate scatterer size. However, in cases where the axial and lateral resolution of the OCT system are larger than the target scatterer, it is difficult to assess the scatterer size directly within the OCT space domain. This paper presents a workflow to estimate diameters of individual free-floating spherical particles within OCT volumes, leveraging adaptive scanning, spectroscopic OCT, and Mie theory. Using this workflow, we demonstrate the capability to estimate individual microbead diameters ranging from 6 to 10 µm, both in isolation and within mixed solutions with 12 × speed up than the previous method. The results indicate that the proposed Mie backscattering approach yields size estimations that were statistically equivalent to labeled values. In experiments with a mixed solution containing microbeads of 6 µm, 8 µm, and 10 µm diameters, our method successfully differentiated the three bead sizes through histogram analysis.
- 24 June 2026
- Published by Optica Publishing Group in Optics Continuum
- Vol. 5 (7) , 2096-2103
Size estimation of mixed free-floating sub-resolution spherical scatterers utilizing adaptive scanning optical coherence tomography
Optical coherence tomography (OCT) is a volumetric imaging technique that enables real-time assessment of biological tissues with micrometer-scale resolution. This enables OCT to also offer the potential to estimate scatterer size. However, in cases where the axial and lateral resolution of the OCT system are larger than the target scatterer, it is difficult to assess the scatterer size directly within the OCT space domain. This paper presents a workflow to estimate diameters of individual free-floating spherical particles within OCT volumes, leveraging adaptive scanning, spectroscopic OCT, and Mie theory. Using this workflow, we demonstrate the capability to estimate individual microbead diameters ranging from 6 to 10 µm, both in isolation and within mixed solutions with 12 × speed up than the previous method. The results indicate that the proposed Mie backscattering approach yields size estimations that were statistically equivalent to labeled values. In experiments with a mixed solution containing microbeads of 6 µm, 8 µm, and 10 µm diameters, our method successfully differentiated the three bead sizes through histogram analysis.
- Open Access
- 9 May 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (19) , eadr5912
Deep compressed multichannel adaptive optics scanning light ophthalmoscope
Adaptive optics scanning light ophthalmoscopy (AOSLO) reveals individual retinal cells and their function, microvasculature, and micropathologies in vivo. As compared to the single-channel offset pinhole and two-channel split-detector nonconfocal AOSLO designs, by providing multidirectional imaging capabilities, a recent generation of multidetector and (multi-)offset aperture AOSLO modalities has been demonstrated to provide critical information about retinal microstructures. However, increasing detection channels requires expensive optical components and/or critically increases imaging time. To address this issue, we present an innovative combination of machine learning and optics as an integrated technology to compressively capture 12 nonconfocal channel AOSLO images simultaneously. Imaging of healthy participants and diseased subjects using the proposed deep compressed multichannel AOSLO showed enhanced visualization of rods, cones, and mural cells with over an order-of-magnitude improvement in imaging speed as compared to conventional offset aperture imaging. To facilitate the adaptation and integration with other in vivo microscopy systems, we made optical design, acquisition, and computational reconstruction codes open source.
- 9 May 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (19) , eadr5912
Open AccessDeep compressed multichannel adaptive optics scanning light ophthalmoscope
Adaptive optics scanning light ophthalmoscopy (AOSLO) reveals individual retinal cells and their function, microvasculature, and micropathologies in vivo. As compared to the single-channel offset pinhole and two-channel split-detector nonconfocal AOSLO designs, by providing multidirectional imaging capabilities, a recent generation of multidetector and (multi-)offset aperture AOSLO modalities has been demonstrated to provide critical information about retinal microstructures. However, increasing detection channels requires expensive optical components and/or critically increases imaging time. To address this issue, we present an innovative combination of machine learning and optics as an integrated technology to compressively capture 12 nonconfocal channel AOSLO images simultaneously. Imaging of healthy participants and diseased subjects using the proposed deep compressed multichannel AOSLO showed enhanced visualization of rods, cones, and mural cells with over an order-of-magnitude improvement in imaging speed as compared to conventional offset aperture imaging. To facilitate the adaptation and integration with other in vivo microscopy systems, we made optical design, acquisition, and computational reconstruction codes open source.
- 26 March 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (4) , 1616-1637
Sensor-driven digital motion correction of robotically-aligned optical coherence tomography retinal volumes
Optical coherence tomography (OCT) has revolutionized diagnostics in retinal ophthalmology. Traditional OCT requires minimal relative motion between the subject and scanner, which is difficult to achieve with handheld devices and/or non-stabilized subjects. We recently introduced robotically-aligned OCT (RAOCT) as an alternative that promises to alleviate these minimal-movement requirements by tracking the subject and compensating for their motion with dynamic hardware components in real-time. However, hardware and image processing delays lead to residual motion artifacts even after automatic alignment and motion compensation. Here, we introduce a novel sensor-driven digital motion correction approach that overcomes these shortcomings. Our method leverages synchronized sensing of both the subject’s eye and the scanner hardware to continuously estimate the imaging system state during acquisition. The A-scans are then remapped using a ray-tracing model of the system at the precise moment of acquisition. We demonstrate that, in addition to motion compensation from RAOCT, our method further reduces residual artifacts by 88.3 %, 80.4 %, and 62.6 % across axial, lateral, and rotational motions, respectively. We also show our correction in human retinal OCT images where residual errors from acquisition were reduced down to 12.4 µm, 0.11°, and 0.39° for axial, lateral, and rotational motion, respectively.
- 26 March 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (4) , 1616-1637
Sensor-driven digital motion correction of robotically-aligned optical coherence tomography retinal volumes
Optical coherence tomography (OCT) has revolutionized diagnostics in retinal ophthalmology. Traditional OCT requires minimal relative motion between the subject and scanner, which is difficult to achieve with handheld devices and/or non-stabilized subjects. We recently introduced robotically-aligned OCT (RAOCT) as an alternative that promises to alleviate these minimal-movement requirements by tracking the subject and compensating for their motion with dynamic hardware components in real-time. However, hardware and image processing delays lead to residual motion artifacts even after automatic alignment and motion compensation. Here, we introduce a novel sensor-driven digital motion correction approach that overcomes these shortcomings. Our method leverages synchronized sensing of both the subject’s eye and the scanner hardware to continuously estimate the imaging system state during acquisition. The A-scans are then remapped using a ray-tracing model of the system at the precise moment of acquisition. We demonstrate that, in addition to motion compensation from RAOCT, our method further reduces residual artifacts by 88.3 %, 80.4 %, and 62.6 % across axial, lateral, and rotational motions, respectively. We also show our correction in human retinal OCT images where residual errors from acquisition were reduced down to 12.4 µm, 0.11°, and 0.39° for axial, lateral, and rotational motion, respectively.
- 10 March 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (6) , 1969-1972
Pupil wobble in point-scanning retinal optical coherence tomography systems
Optical coherence tomography (OCT) systems utilize 2D scanning methods to acquire reflectance-based volumetric images of samples, such as the human retina, with micrometer-scale depth resolution. A common method for performing this scanning at high speeds is to use a pair of sequential, single-axis galvanometer scanners. An undesired effect of using separated scanners is the variation in the beam position at the pupil plane, a phenomenon known as beam wander or pupil wobble. This can lead to loss of signal and vignetting artifacts in the resulting images. To overcome these limitations, we propose a method to deterministically analyze the pupil wobble in a given retinal OCT system and to correct for the displacement using pupil tracking OCT with a 2D scanning mirror placed anti-conjugate to the pupil plane. We demonstrate that we can model the pattern of pupil wobble present in any OCT system both theoretically and empirically and then use a pupil tracking system to correct for the displacement of the beam to acquire OCT images without the imposed artifacts.
- 10 March 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (6) , 1969-1972
Pupil wobble in point-scanning retinal optical coherence tomography systems
Optical coherence tomography (OCT) systems utilize 2D scanning methods to acquire reflectance-based volumetric images of samples, such as the human retina, with micrometer-scale depth resolution. A common method for performing this scanning at high speeds is to use a pair of sequential, single-axis galvanometer scanners. An undesired effect of using separated scanners is the variation in the beam position at the pupil plane, a phenomenon known as beam wander or pupil wobble. This can lead to loss of signal and vignetting artifacts in the resulting images. To overcome these limitations, we propose a method to deterministically analyze the pupil wobble in a given retinal OCT system and to correct for the displacement using pupil tracking OCT with a 2D scanning mirror placed anti-conjugate to the pupil plane. We demonstrate that we can model the pattern of pupil wobble present in any OCT system both theoretically and empirically and then use a pupil tracking system to correct for the displacement of the beam to acquire OCT images without the imposed artifacts.
- Top Cited Papers
- 16 January 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (2) , 578-602
Robotics and optical coherence tomography: current works and future perspectives [Invited]
Optical coherence tomography (OCT) is an interferometric technique for micron-level imaging in biological and non-biological contexts. As a non-invasive, non-ionizing, and video-rate imaging modality, OCT is widely used in biomedical and clinical applications, especially ophthalmology, where it functions in many roles, including tissue mapping, disease diagnosis, and intrasurgical visualization. In recent years, the rapid growth of medical robotics has led to new applications for OCT, primarily for 3D free-space scanning, volumetric perception, and novel optical designs for specialized medical applications. This review paper surveys these recent developments at the intersection of OCT and robotics and organizes them by degree of integration and application, with a focus on biomedical and clinical topics. We conclude with perspectives on how these recent innovations may lead to further advances in imaging and medical technology.
- 16 January 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (2) , 578-602
Top Cited PapersRobotics and optical coherence tomography: current works and future perspectives [Invited]
Optical coherence tomography (OCT) is an interferometric technique for micron-level imaging in biological and non-biological contexts. As a non-invasive, non-ionizing, and video-rate imaging modality, OCT is widely used in biomedical and clinical applications, especially ophthalmology, where it functions in many roles, including tissue mapping, disease diagnosis, and intrasurgical visualization. In recent years, the rapid growth of medical robotics has led to new applications for OCT, primarily for 3D free-space scanning, volumetric perception, and novel optical designs for specialized medical applications. This review paper surveys these recent developments at the intersection of OCT and robotics and organizes them by degree of integration and application, with a focus on biomedical and clinical topics. We conclude with perspectives on how these recent innovations may lead to further advances in imaging and medical technology.
- Open Access
- 9 January 2023
- Published by Springer Nature in Research Square
Contactless, autonomous robotic alignment of optical coherence tomography for in vivo evaluation of diseased retinas
During the COVID-19 pandemic, an emphasis was placed on contactless, physical distancing and improved telehealth; contrariwise, standard-of-care ophthalmic imaging of patients required present, trained personnel. Here, we introduce contactless, autonomous robotic alignment of optical coherence tomography (RAOCT) for in vivo imaging of retinal disease and compare measured retinal thickness and diagnostic readability to technician operated clinical OCT. In a powered study, we found no statistically significant difference in retinal thickness in both healthy and diseased retinas (p > 0.7) or across a variety of demographics (gender, race, and age) between RAOCT and clinical OCT. In a secondary study, a retina specialist labeled a given volume as normal/abnormal. Compared to the clinical diagnostic label, sensitivity/specificity for RAOCT were equal or improved over clinical OCT. Contactless, autonomous RAOCT, that improves upon current clinical OCT, could play a role in both ophthalmic care and non-ophthalmic settings that would benefit from improved eye care.
- 9 January 2023
- Published by Springer Nature in Research Square
Open AccessContactless, autonomous robotic alignment of optical coherence tomography for in vivo evaluation of diseased retinas
During the COVID-19 pandemic, an emphasis was placed on contactless, physical distancing and improved telehealth; contrariwise, standard-of-care ophthalmic imaging of patients required present, trained personnel. Here, we introduce contactless, autonomous robotic alignment of optical coherence tomography (RAOCT) for in vivo imaging of retinal disease and compare measured retinal thickness and diagnostic readability to technician operated clinical OCT. In a powered study, we found no statistically significant difference in retinal thickness in both healthy and diseased retinas (p > 0.7) or across a variety of demographics (gender, race, and age) between RAOCT and clinical OCT. In a secondary study, a retina specialist labeled a given volume as normal/abnormal. Compared to the clinical diagnostic label, sensitivity/specificity for RAOCT were equal or improved over clinical OCT. Contactless, autonomous RAOCT, that improves upon current clinical OCT, could play a role in both ophthalmic care and non-ophthalmic settings that would benefit from improved eye care.
- 16 November 2022
- Published by Optica Publishing Group in Optica
- Vol. 9 (11) , 1276-1288
Adaptive point-scan imaging beyond the frame rate–resolution limit with scene-reactive scan trajectories
Point-scanned imaging modalities such as optical coherence tomography (OCT) are subject to frame rate limits governed by the image resolution, sampling rate, and scanner dynamics. For scenes with dynamic features on static backgrounds, adaptive scanning escapes these limits by visiting scan positions only as needed. We implemented adaptive scanning using a probabilistic approach that balanced re-imaging of known dynamic positions with exploration for undiscovered ones. We evaluated our approach in model systems that simulated multitarget tracking and ophthalmic surgery using a swept-source OCT system. We demonstrated frame rate speedups in excess of 5 × without degradation in image quality, a performance that would have otherwise required a significantly faster source.
- 16 November 2022
- Published by Optica Publishing Group in Optica
- Vol. 9 (11) , 1276-1288
Adaptive point-scan imaging beyond the frame rate–resolution limit with scene-reactive scan trajectories
Point-scanned imaging modalities such as optical coherence tomography (OCT) are subject to frame rate limits governed by the image resolution, sampling rate, and scanner dynamics. For scenes with dynamic features on static backgrounds, adaptive scanning escapes these limits by visiting scan positions only as needed. We implemented adaptive scanning using a probabilistic approach that balanced re-imaging of known dynamic positions with exploration for undiscovered ones. We evaluated our approach in model systems that simulated multitarget tracking and ophthalmic surgery using a swept-source OCT system. We demonstrated frame rate speedups in excess of 5 × without degradation in image quality, a performance that would have otherwise required a significantly faster source.