Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nicola Secciani has a total of 86 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Introduction of robotics into a well-established navigation OR team for TKA does not increase surgical time. A one center evaluation

    by Lorenzo Maggi, Yves Vanderschelden, David Burlot, Nicola Secciani, Benedetto Allotta

    Robotic-assisted Total Knee Arthroplasty (RA-TKA) enhances precision but is historically associated with increased operative times and workflow disruption. This study evaluates whether integrating a novel open-platform robotic effector into an established, familiar navigation workflow mitigates the learning curve and maintains total operative time compared to standard navigation. A retrospective comparative analysis was performed on 236 primary TKAs (142 NAV-TKA vs. 94 RA-TKA) performed by a single high-volume surgical team. Operative times were segmented into five phases using synchronized system logs. Educational cases were excluded. The learning curve was analyzed using Cumulative Sum (CUSUM) control charts. Multi-way analysis across independent cohorts showed a significant global variation in total skin-to-skin time ( p < 0.001). However, post-hoc pairwise testing demonstrated that while the initial learning phase was significantly longer (Median: 84.00 min), the steady-state proficiency phase (Median: 77.00 min) achieved a comparable time profile to the legacy navigation workflow (Median: 81.00 min; p > 0.017), avoiding an overall sustained time penalty. CUSUM analysis identified a learning curve of 58 cases. In the proficiency phase, the active robotic resection time was significantly faster than manual navigated resection (17.95 vs. 19.08 min; p = 0.009). The open-platform robotic system successfully integrated into the clinical workflow without introducing an overall sustained time penalty. Retaining a familiar interface effectively cushions the initial efficiency loss typical of closed platforms. Once proficiency is attained, active robotic assistance significantly enhances mechanical resection speed, offsetting the mandatory intra-operative planning time investment.

  • Open Access

    A Resource-Efficient Method for Real-Time Flexion–Extension Angle Estimation with an Under-Sensorized Finger Exoskeleton

    by Alessia Di Natale, Matilde Gelli, Gherardo Liverani, Alessandro Ridolfi, Benedetto Allotta, Nicola Secciani

    Hand exoskeletons are used in rehabilitation together with serious games to enhance patient experience and, possibly, therapy outcomes. To achieve good engagement, a realistic virtual representation of hand motion is needed; however, the relationship between exoskeleton joint motion and anatomical finger kinematics is rarely obtained using low-cost procedures. This work introduces a mechanical redesign and modeling pipeline that utilizes temporary sensors to identify the exoskeleton–finger mapping, enabling qualitatively realistic virtual hand motion driven solely by the existing on-board sensor. A recently developed hand exoskeleton prototype was redesigned to host two temporary rotary encoders aligned with the MetaCarpoPhalangeal (MCP) and Proximal InterPhalangeal (PIP) joints, in addition to the actuation encoder. Healthy subjects wore the modified device and performed full flexion–extension cycles. Encoder trajectories were processed; then each cycle was approximated by a third-order polynomial in the normalized actuation angle, and a group-level model was obtained by averaging coefficients across valid cycles. Finally, the encoder-based reconstructions of MCP and PIP motion were evaluated against measurements from a gold-standard optical motion capture system. Results indicate that the proposed polynomial model enables joint-angle estimation with sufficient accuracy for interactive rehabilitation scenarios, supporting its use to drive smooth virtual hand motion from the on-board exoskeleton encoder alone.

  • Open Access

    Introducing DANTE: a fully wearable, hybrid-architecture hand exoskeleton for multi-finger grasp assistance

    by Chiara Brogi, Gherardo Liverani, Matilde Gelli, Alessandro Bucci, Alberto Topini, Alessandro Ridolfi, Nicola Secciani

  • Open Access

    A Semantic Seafloor Mapping Methodology for Enhanced Monitoring of Posidonia Oceanica Meadows

    by Alessandro Bucci, Gherardo Liverani, Lorenzo Cecchi, Filippo Parati, Alberto Topini, Nicola Secciani, Alessandro Ridolfi

  • Human-Robot Interaction Module for Gravity Compensation in Robot-Assisted Rehabilitation of the Hand and Upper Limb

    by Andrea Paoli, Lorenzo Maggi, Nicola Secciani, Alessandro Ridolfi, Benedetto Allotta


  • Robot-Assisted Rehabilitation: Mechatronic Redesign of a Finger Exoskeleton to Improve Its Motion Tracking Capabilities

    by Alessia Di Natale, Lorenzo Bartalucci, Nicola Secciani, Gherardo Liverani, Alessandro Ridolfi, Benedetto Allotta


  • Open Access

    External devices increasing bone quality in animals: A systematic review

    by Agostino Igor Mirulla, Chiara Brogi, Giuseppe Barone, Nicola Secciani, William Sansom, Lorenzo Bartalucci, Alessandro Ridolfi, Benedetto Allotta, Laura Bragonzoni

  • Open Access

    A Kinaesthetic Hand Exoskeleton System Toward Robot-augmented Rehabilitation Therapies in the Health 4.0 era

    by Lorenzo Bartalucci, Chiara Brogi, Alessandro Bucci, Alberto Topini, Andrea Della Valle, Nicola Secciani, Alessandro Ridolfi, Benedetto Allotta

    In the new era of Industry 4.0, digitization and automation are the tipping points for addressing rapidly evolving challenges. The momentum of this movement has underscored the critical importance of developing new technologies to collect, understand and use the enormous amount of data created. This revolutionary wave has also taken root in the healthcare sector, giving rise to the so-called Health 4.0, based on smart machines to provide patients with better, more value-added and more efficient healthcare services. This scenario has contributed to making innovative robot-augmented therapies a hot research topic with potentially significant societal impact. In this context, the authors present the implementation of a new prototype of a kinaesthetic exoskeleton to enhance and recover sensorimotor skills to perform grasping and manipulation via force stimuli from serious rehabilitation games. The discussion includes an initial overview of the system's hardware, both from a mechanical and electronic point of view, motivating the choices made in the design phase. It continues by moving on to a description of the system's low-level and high-level software architecture, along with the control strategy applied to implement progressive resistant force therapy. Finally, an example of serious game was developed as an application case for evaluating the system's usability and extrapolating empirical parameters indicative of responsiveness and accuracy. The results showed that the proposed system can reproduce constant forces with an average error of 0.75 N and standard deviation of 0.3 N with an average reaction time of 0.5 s and standard deviation of 0.4 s.


  • Open Access

    Enhancing sEMG-Based Finger Motion Prediction with CNN-LSTM Regressors for Controlling a Hand Exoskeleton

    by Mirco Vangi, Mirco Vangi, Chiara Brogi, Chiara Brogi, Alberto Topini, Alberto Topini, Nicola Secciani, Nicola Secciani, Alessandro Ridolfi, Alessandro Ridolfi

    In recent years, the number of people with disabilities has increased hugely, especially in low- and middle-income countries. At the same time, robotics has made significant advances in the medical field, and many research groups have begun to develop low-cost wearable solutions. The Mechatronics and Dynamic Modelling Lab of the Department of Industrial Engineering at the University of Florence has recently developed a new version of a wearable hand exoskeleton for assistive purposes. In this paper, we will present a new regression method to predict the finger angle position of the first joint from the value of the sEMG of the forearm and the previous position of the finger itself. To acquire the dataset necessary to train the regressor a specific graphical user interface was developed which was able to acquire sEMG data from a Myo armband and the finger position from a Leap Motion Controller. Two long short-term memory (LSTM) models were compared, one in its standard configuration and the other with a convolutional layer, yielding significantly better performance for the second one, with an increase in R2 coefficient from an average value of 0.746 to 0.825, leading to the conclusion that a convolutional layer could increase performance when few sensors are available.


  • Open Access

    Topology Optimization of Static Turbomachinery Components

    by Francesco Buonamici, Enrico Meli, Nicola Secciani, Alessandro Ridolfi, Andrea Rindi, Rocco Furferi

    Additive Manufacturing has enabled the design of complex components in several technical fields. Considering turbomachinery components, additive manufacturing has unlocked the achievement of significant performances for dynamic rotoring components. The application of topology optimization methods is one of the main factors accelerating the technological development of this sector. This paper presents a procedure for the optimization of static turbomachinery components. The framework proposed compares the results obtained by introducing a lattice structure and a solid optimized shape. The procedure is presented with reference to a specific case study. To validate the proposed framework, the complete redesign of a thrust collar of a major Italian-based Oil&Gas company is carried out, demonstrating that the rethinking of the component in terms of Topology Optimization is a straightforward approach to increase the overall performance of the produced part.