Nicola Secciani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nicola Secciani has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Ridolfi
Department of Industrial Engineering, University of Florence, 50139 Florence, Italy
23 shared publications Alessandro Ridolfi
University of Florence
16 shared publications- Benedetto Allotta
Department of Industrial Engineering University of Florence Florence Italy
11 shared publications - Alberto Topini
University of Florence
10 shared publications Benedetto Allotta
University of Florence
9 shared publications- Chiara Brogi
University of Florence
7 shared publications
Latest Publications
- Open Access
- 19 June 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1)
Introduction of robotics into a well-established navigation OR team for TKA does not increase surgical time. A one center evaluation
Robotic-assisted Total Knee Arthroplasty (RA-TKA) enhances precision but is historically associated with increased operative times and workflow disruption. This study evaluates whether integrating a novel open-platform robotic effector into an established, familiar navigation workflow mitigates the learning curve and maintains total operative time compared to standard navigation. A retrospective comparative analysis was performed on 236 primary TKAs (142 NAV-TKA vs. 94 RA-TKA) performed by a single high-volume surgical team. Operative times were segmented into five phases using synchronized system logs. Educational cases were excluded. The learning curve was analyzed using Cumulative Sum (CUSUM) control charts. Multi-way analysis across independent cohorts showed a significant global variation in total skin-to-skin time ( p < 0.001). However, post-hoc pairwise testing demonstrated that while the initial learning phase was significantly longer (Median: 84.00 min), the steady-state proficiency phase (Median: 77.00 min) achieved a comparable time profile to the legacy navigation workflow (Median: 81.00 min; p > 0.017), avoiding an overall sustained time penalty. CUSUM analysis identified a learning curve of 58 cases. In the proficiency phase, the active robotic resection time was significantly faster than manual navigated resection (17.95 vs. 19.08 min; p = 0.009). The open-platform robotic system successfully integrated into the clinical workflow without introducing an overall sustained time penalty. Retaining a familiar interface effectively cushions the initial efficiency loss typical of closed platforms. Once proficiency is attained, active robotic assistance significantly enhances mechanical resection speed, offsetting the mandatory intra-operative planning time investment.
- 19 June 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1)
Open AccessIntroduction of robotics into a well-established navigation OR team for TKA does not increase surgical time. A one center evaluation
Robotic-assisted Total Knee Arthroplasty (RA-TKA) enhances precision but is historically associated with increased operative times and workflow disruption. This study evaluates whether integrating a novel open-platform robotic effector into an established, familiar navigation workflow mitigates the learning curve and maintains total operative time compared to standard navigation. A retrospective comparative analysis was performed on 236 primary TKAs (142 NAV-TKA vs. 94 RA-TKA) performed by a single high-volume surgical team. Operative times were segmented into five phases using synchronized system logs. Educational cases were excluded. The learning curve was analyzed using Cumulative Sum (CUSUM) control charts. Multi-way analysis across independent cohorts showed a significant global variation in total skin-to-skin time ( p < 0.001). However, post-hoc pairwise testing demonstrated that while the initial learning phase was significantly longer (Median: 84.00 min), the steady-state proficiency phase (Median: 77.00 min) achieved a comparable time profile to the legacy navigation workflow (Median: 81.00 min; p > 0.017), avoiding an overall sustained time penalty. CUSUM analysis identified a learning curve of 58 cases. In the proficiency phase, the active robotic resection time was significantly faster than manual navigated resection (17.95 vs. 19.08 min; p = 0.009). The open-platform robotic system successfully integrated into the clinical workflow without introducing an overall sustained time penalty. Retaining a familiar interface effectively cushions the initial efficiency loss typical of closed platforms. Once proficiency is attained, active robotic assistance significantly enhances mechanical resection speed, offsetting the mandatory intra-operative planning time investment.
- Open Access
- 4 February 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (3) , 1575
A Resource-Efficient Method for Real-Time Flexion–Extension Angle Estimation with an Under-Sensorized Finger Exoskeleton
Hand exoskeletons are used in rehabilitation together with serious games to enhance patient experience and, possibly, therapy outcomes. To achieve good engagement, a realistic virtual representation of hand motion is needed; however, the relationship between exoskeleton joint motion and anatomical finger kinematics is rarely obtained using low-cost procedures. This work introduces a mechanical redesign and modeling pipeline that utilizes temporary sensors to identify the exoskeleton–finger mapping, enabling qualitatively realistic virtual hand motion driven solely by the existing on-board sensor. A recently developed hand exoskeleton prototype was redesigned to host two temporary rotary encoders aligned with the MetaCarpoPhalangeal (MCP) and Proximal InterPhalangeal (PIP) joints, in addition to the actuation encoder. Healthy subjects wore the modified device and performed full flexion–extension cycles. Encoder trajectories were processed; then each cycle was approximated by a third-order polynomial in the normalized actuation angle, and a group-level model was obtained by averaging coefficients across valid cycles. Finally, the encoder-based reconstructions of MCP and PIP motion were evaluated against measurements from a gold-standard optical motion capture system. Results indicate that the proposed polynomial model enables joint-angle estimation with sufficient accuracy for interactive rehabilitation scenarios, supporting its use to drive smooth virtual hand motion from the on-board exoskeleton encoder alone.
- 4 February 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (3) , 1575
Open AccessA Resource-Efficient Method for Real-Time Flexion–Extension Angle Estimation with an Under-Sensorized Finger Exoskeleton
Hand exoskeletons are used in rehabilitation together with serious games to enhance patient experience and, possibly, therapy outcomes. To achieve good engagement, a realistic virtual representation of hand motion is needed; however, the relationship between exoskeleton joint motion and anatomical finger kinematics is rarely obtained using low-cost procedures. This work introduces a mechanical redesign and modeling pipeline that utilizes temporary sensors to identify the exoskeleton–finger mapping, enabling qualitatively realistic virtual hand motion driven solely by the existing on-board sensor. A recently developed hand exoskeleton prototype was redesigned to host two temporary rotary encoders aligned with the MetaCarpoPhalangeal (MCP) and Proximal InterPhalangeal (PIP) joints, in addition to the actuation encoder. Healthy subjects wore the modified device and performed full flexion–extension cycles. Encoder trajectories were processed; then each cycle was approximated by a third-order polynomial in the normalized actuation angle, and a group-level model was obtained by averaging coefficients across valid cycles. Finally, the encoder-based reconstructions of MCP and PIP motion were evaluated against measurements from a gold-standard optical motion capture system. Results indicate that the proposed polynomial model enables joint-angle estimation with sufficient accuracy for interactive rehabilitation scenarios, supporting its use to drive smooth virtual hand motion from the on-board exoskeleton encoder alone.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Oceanic Engineering
- p. 1-15
A Semantic Seafloor Mapping Methodology for Enhanced Monitoring of Posidonia Oceanica Meadows
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Oceanic Engineering
- p. 1-15
Open AccessA Semantic Seafloor Mapping Methodology for Enhanced Monitoring of Posidonia Oceanica Meadows
- 27 February 2025
- Published by Springer Nature
- p. 546-550
Human-Robot Interaction Module for Gravity Compensation in Robot-Assisted Rehabilitation of the Hand and Upper Limb
- 27 February 2025
- Published by Springer Nature
- p. 546-550
Human-Robot Interaction Module for Gravity Compensation in Robot-Assisted Rehabilitation of the Hand and Upper Limb
- Open Access
- 22 September 2023
- Published by Association for Computing Machinery (ACM)
- p. 135-142
A Kinaesthetic Hand Exoskeleton System Toward Robot-augmented Rehabilitation Therapies in the Health 4.0 era
In the new era of Industry 4.0, digitization and automation are the tipping points for addressing rapidly evolving challenges. The momentum of this movement has underscored the critical importance of developing new technologies to collect, understand and use the enormous amount of data created. This revolutionary wave has also taken root in the healthcare sector, giving rise to the so-called Health 4.0, based on smart machines to provide patients with better, more value-added and more efficient healthcare services. This scenario has contributed to making innovative robot-augmented therapies a hot research topic with potentially significant societal impact. In this context, the authors present the implementation of a new prototype of a kinaesthetic exoskeleton to enhance and recover sensorimotor skills to perform grasping and manipulation via force stimuli from serious rehabilitation games. The discussion includes an initial overview of the system's hardware, both from a mechanical and electronic point of view, motivating the choices made in the design phase. It continues by moving on to a description of the system's low-level and high-level software architecture, along with the control strategy applied to implement progressive resistant force therapy. Finally, an example of serious game was developed as an application case for evaluating the system's usability and extrapolating empirical parameters indicative of responsiveness and accuracy. The results showed that the proposed system can reproduce constant forces with an average error of 0.75 N and standard deviation of 0.3 N with an average reaction time of 0.5 s and standard deviation of 0.4 s.
- 22 September 2023
- Published by Association for Computing Machinery (ACM)
- p. 135-142
Open AccessA Kinaesthetic Hand Exoskeleton System Toward Robot-augmented Rehabilitation Therapies in the Health 4.0 era
In the new era of Industry 4.0, digitization and automation are the tipping points for addressing rapidly evolving challenges. The momentum of this movement has underscored the critical importance of developing new technologies to collect, understand and use the enormous amount of data created. This revolutionary wave has also taken root in the healthcare sector, giving rise to the so-called Health 4.0, based on smart machines to provide patients with better, more value-added and more efficient healthcare services. This scenario has contributed to making innovative robot-augmented therapies a hot research topic with potentially significant societal impact. In this context, the authors present the implementation of a new prototype of a kinaesthetic exoskeleton to enhance and recover sensorimotor skills to perform grasping and manipulation via force stimuli from serious rehabilitation games. The discussion includes an initial overview of the system's hardware, both from a mechanical and electronic point of view, motivating the choices made in the design phase. It continues by moving on to a description of the system's low-level and high-level software architecture, along with the control strategy applied to implement progressive resistant force therapy. Finally, an example of serious game was developed as an application case for evaluating the system's usability and extrapolating empirical parameters indicative of responsiveness and accuracy. The results showed that the proposed system can reproduce constant forces with an average error of 0.75 N and standard deviation of 0.3 N with an average reaction time of 0.5 s and standard deviation of 0.4 s.
- Open Access
Enhancing sEMG-Based Finger Motion Prediction with CNN-LSTM Regressors for Controlling a Hand Exoskeleton
In recent years, the number of people with disabilities has increased hugely, especially in low- and middle-income countries. At the same time, robotics has made significant advances in the medical field, and many research groups have begun to develop low-cost wearable solutions. The Mechatronics and Dynamic Modelling Lab of the Department of Industrial Engineering at the University of Florence has recently developed a new version of a wearable hand exoskeleton for assistive purposes. In this paper, we will present a new regression method to predict the finger angle position of the first joint from the value of the sEMG of the forearm and the previous position of the finger itself. To acquire the dataset necessary to train the regressor a specific graphical user interface was developed which was able to acquire sEMG data from a Myo armband and the finger position from a Leap Motion Controller. Two long short-term memory (LSTM) models were compared, one in its standard configuration and the other with a convolutional layer, yielding significantly better performance for the second one, with an increase in coefficient from an average value of to , leading to the conclusion that a convolutional layer could increase performance when few sensors are available.Open AccessEnhancing sEMG-Based Finger Motion Prediction with CNN-LSTM Regressors for Controlling a Hand Exoskeleton
In recent years, the number of people with disabilities has increased hugely, especially in low- and middle-income countries. At the same time, robotics has made significant advances in the medical field, and many research groups have begun to develop low-cost wearable solutions. The Mechatronics and Dynamic Modelling Lab of the Department of Industrial Engineering at the University of Florence has recently developed a new version of a wearable hand exoskeleton for assistive purposes. In this paper, we will present a new regression method to predict the finger angle position of the first joint from the value of the sEMG of the forearm and the previous position of the finger itself. To acquire the dataset necessary to train the regressor a specific graphical user interface was developed which was able to acquire sEMG data from a Myo armband and the finger position from a Leap Motion Controller. Two long short-term memory (LSTM) models were compared, one in its standard configuration and the other with a convolutional layer, yielding significantly better performance for the second one, with an increase in coefficient from an average value of to , leading to the conclusion that a convolutional layer could increase performance when few sensors are available. - Open Access
- 3 May 2023
- Published by Jan Evangelista Purkyne University in Usti nad Labem in Manufacturing Technology
- Vol. 23 (1) , 11-24
Topology Optimization of Static Turbomachinery Components
Additive Manufacturing has enabled the design of complex components in several technical fields. Considering turbomachinery components, additive manufacturing has unlocked the achievement of significant performances for dynamic rotoring components. The application of topology optimization methods is one of the main factors accelerating the technological development of this sector. This paper presents a procedure for the optimization of static turbomachinery components. The framework proposed compares the results obtained by introducing a lattice structure and a solid optimized shape. The procedure is presented with reference to a specific case study. To validate the proposed framework, the complete redesign of a thrust collar of a major Italian-based Oil&Gas company is carried out, demonstrating that the rethinking of the component in terms of Topology Optimization is a straightforward approach to increase the overall performance of the produced part.
- 3 May 2023
- Published by Jan Evangelista Purkyne University in Usti nad Labem in Manufacturing Technology
- Vol. 23 (1) , 11-24
Open AccessTopology Optimization of Static Turbomachinery Components
Additive Manufacturing has enabled the design of complex components in several technical fields. Considering turbomachinery components, additive manufacturing has unlocked the achievement of significant performances for dynamic rotoring components. The application of topology optimization methods is one of the main factors accelerating the technological development of this sector. This paper presents a procedure for the optimization of static turbomachinery components. The framework proposed compares the results obtained by introducing a lattice structure and a solid optimized shape. The procedure is presented with reference to a specific case study. To validate the proposed framework, the complete redesign of a thrust collar of a major Italian-based Oil&Gas company is carried out, demonstrating that the rethinking of the component in terms of Topology Optimization is a straightforward approach to increase the overall performance of the produced part.