René Stübi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
René Stübi has a total of 143 co-authors. Here are the top co-authors by number of shared publications:
Herbert Schill
Physikalisch-Meteorologisches Observatorium Davos, World Radiation Center, Davos, Switzerland
7 shared publications- Jörg Klausen
Federal Office of Meteorology and Climatology MeteoSwiss, Zurich, Switzerland
7 shared publications - Alexander Haefele
Federal Office of Meteorology and Climatology, MeteoSwiss, Payerne, Switzerland
5 shared publications - Eliane Maillard Barras
Federal Meteorology and Climatology, Payerne, Switzerland
5 shared publications - Roeland Van Malderen
Royal Meteorological Institute of Belgium, Brussels, Belgium
5 shared publications - Anne Mee Thompson
Earth Sciences Division, NASA Goddard Space Flight Center, Greenbelt, Maryland, USA
4 shared publications
Latest Publications
- Open Access
- 30 January 2023
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 128 (3)
An Unprecedented Arctic Ozone Depletion Event During Spring 2020 and Its Impacts Across Europe
The response of the ozone column across Europe to the extreme 2020 Arctic ozone depletion was examined by analyzing ground‐based observations at 38 European stations. The ozone decrease at the northernmost site, Ny‐Ålesund (79°N) was about 43% with respect to a climatology of more than 30 years. The magnitude of the decrease declined by about 0.7% deg−1 moving south to reach nearly 15% at 40°N. In addition, it was found that the variations of the ozone column at each of the selected stations in March‐May were similar to those observed at Ny‐Ålesund but with a delay increasing to about 20 days at mid‐latitudes with a gradient of approximately 0.5 days deg−1. The distributions of reconstructed ozone column anomalies over a sector covering a large European area show decreasing ozone that started from the north at the beginning of April 2020 and spread south. Such behavior was shown to be similar to that observed after the Arctic ozone depletion in 2011. Stratospheric dynamical patterns in March–May 2011 and during 2020 suggested that the migration of ozone‐poor air masses from polar areas to the south after the vortex breakup caused the observed ozone responses. A brief survey of the ozone mass mixing ratios at three stratospheric levels showed the exceptional strength of the 2020 episode. Despite the stronger and longer‐lasting Arctic ozone loss in 2020, the analysis in this work indicates a similar ozone response at latitudes below 50°N to both 2011 and 2020 phenomena.
- 30 January 2023
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 128 (3)
Open AccessAn Unprecedented Arctic Ozone Depletion Event During Spring 2020 and Its Impacts Across Europe
The response of the ozone column across Europe to the extreme 2020 Arctic ozone depletion was examined by analyzing ground‐based observations at 38 European stations. The ozone decrease at the northernmost site, Ny‐Ålesund (79°N) was about 43% with respect to a climatology of more than 30 years. The magnitude of the decrease declined by about 0.7% deg−1 moving south to reach nearly 15% at 40°N. In addition, it was found that the variations of the ozone column at each of the selected stations in March‐May were similar to those observed at Ny‐Ålesund but with a delay increasing to about 20 days at mid‐latitudes with a gradient of approximately 0.5 days deg−1. The distributions of reconstructed ozone column anomalies over a sector covering a large European area show decreasing ozone that started from the north at the beginning of April 2020 and spread south. Such behavior was shown to be similar to that observed after the Arctic ozone depletion in 2011. Stratospheric dynamical patterns in March–May 2011 and during 2020 suggested that the migration of ozone‐poor air masses from polar areas to the south after the vortex breakup caused the observed ozone responses. A brief survey of the ozone mass mixing ratios at three stratospheric levels showed the exceptional strength of the 2020 episode. Despite the stronger and longer‐lasting Arctic ozone loss in 2020, the analysis in this work indicates a similar ozone response at latitudes below 50°N to both 2011 and 2020 phenomena.
- Open Access
- 8 November 2022
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 22 (21) , 14283-14302
Dynamical linear modeling estimates of long-term ozone trends from homogenized Dobson Umkehr profiles at Arosa/Davos, Switzerland
Six collocated spectrophotometers based in Arosa/Davos, Switzerland, have been measuring ozone profiles continuously since 1956 for the oldest Dobson instrument and since 2005 for the Brewer instruments. The datasets of these two ground-based triads (three Dobsons and three Brewers) allow for continuous intercomparisons and derivation of long-term trend estimates. Mainly, two periods in the post-2000 Dobson D051 dataset show anomalies when compared to the Brewer triad time series: in 2011–2013, an offset has been attributed to technical interventions during the renewal of the spectrophotometer acquisition system, and in 2018, an offset with respect to the Brewer triad has been detected following an instrumental change on the spectrophotometer wedge. In this study, the worldwide longest Umkehr dataset (1956–2020) is carefully homogenized using collocated and simultaneous Dobson and Brewer measurements. A recently published report (Garane et al., 2022) described results of an independent homogenization of the same dataset performed by comparison to the Modern-Era Retrospective analysis for Research and Applications version 2 (MERRA-2) Global Modeling Initiative (M2GMI) model simulations. In this paper, the two versions of homogenized Dobson D051 records are intercompared to analyze residual differences found during the correction periods. The Aura Microwave Limb Sounder (MLS) station overpass record (2005–2020) is used as an independent reference for the comparisons. The two homogenized data records show common correction periods, except for the 2017–2018 period, and the corrections are similar in magnitude. In addition, the post-2000 ozone profile trends are estimated from the two homogenized Dobson D051 time series by dynamical linear modeling (DLM), and results are compared with the DLM trends derived from the collocated Brewer Umkehr time series. By first investigating the long-term Dobson ozone record for trends using the well-established multilinear regression (MLR) method, we find that the trends obtained by both MLR and DLM techniques are similar within their uncertainty ranges in the upper and middle stratosphere but that the trend's significances differ in the lower stratosphere. Post-2000 DLM trend estimates show a positive trend of 0.2 to 0.5 % yr−1 above 35 km, significant for Dobson D051 but lower and therefore nonsignificantly different from zero at the 95 % level of confidence for Brewer B040. As shown for the Dobson D051 data record, the trend only seems to become significantly positive in 2004. Moreover, a persistent negative trend is estimated in the middle stratosphere between 25 and 30 km. In the lower stratosphere, the trend is negative at 20 km, with different levels of significance depending on the period and on the dataset.
- 8 November 2022
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 22 (21) , 14283-14302
Open AccessDynamical linear modeling estimates of long-term ozone trends from homogenized Dobson Umkehr profiles at Arosa/Davos, Switzerland
Six collocated spectrophotometers based in Arosa/Davos, Switzerland, have been measuring ozone profiles continuously since 1956 for the oldest Dobson instrument and since 2005 for the Brewer instruments. The datasets of these two ground-based triads (three Dobsons and three Brewers) allow for continuous intercomparisons and derivation of long-term trend estimates. Mainly, two periods in the post-2000 Dobson D051 dataset show anomalies when compared to the Brewer triad time series: in 2011–2013, an offset has been attributed to technical interventions during the renewal of the spectrophotometer acquisition system, and in 2018, an offset with respect to the Brewer triad has been detected following an instrumental change on the spectrophotometer wedge. In this study, the worldwide longest Umkehr dataset (1956–2020) is carefully homogenized using collocated and simultaneous Dobson and Brewer measurements. A recently published report (Garane et al., 2022) described results of an independent homogenization of the same dataset performed by comparison to the Modern-Era Retrospective analysis for Research and Applications version 2 (MERRA-2) Global Modeling Initiative (M2GMI) model simulations. In this paper, the two versions of homogenized Dobson D051 records are intercompared to analyze residual differences found during the correction periods. The Aura Microwave Limb Sounder (MLS) station overpass record (2005–2020) is used as an independent reference for the comparisons. The two homogenized data records show common correction periods, except for the 2017–2018 period, and the corrections are similar in magnitude. In addition, the post-2000 ozone profile trends are estimated from the two homogenized Dobson D051 time series by dynamical linear modeling (DLM), and results are compared with the DLM trends derived from the collocated Brewer Umkehr time series. By first investigating the long-term Dobson ozone record for trends using the well-established multilinear regression (MLR) method, we find that the trends obtained by both MLR and DLM techniques are similar within their uncertainty ranges in the upper and middle stratosphere but that the trend's significances differ in the lower stratosphere. Post-2000 DLM trend estimates show a positive trend of 0.2 to 0.5 % yr−1 above 35 km, significant for Dobson D051 but lower and therefore nonsignificantly different from zero at the 95 % level of confidence for Brewer B040. As shown for the Dobson D051 data record, the trend only seems to become significantly positive in 2004. Moreover, a persistent negative trend is estimated in the middle stratosphere between 25 and 30 km. In the lower stratosphere, the trend is negative at 20 km, with different levels of significance depending on the period and on the dataset.
- Top Cited PapersOpen Access
- 21 October 2022
- Published by American Geophysical Union (AGU) in Earth and Space Science
- Vol. 9 (10)
An Examination of the Recent Stability of Ozonesonde Global Network Data
The recent Assessment of Standard Operating Procedures for Ozonesondes 2.0 (WMO/GAW Report #268) addressed questions of homogeneity and long‐term stability in global electrochemical concentration cell (ECC) ozone sounding network time series. Among its recommendations was adoption of a standard for evaluating data quality in ozonesonde time series. Total column ozone (TCO) derived from the sondes compared to TCO from Aura's Ozone Monitoring Instrument (OMI) is a primary quality indicator. Comparisons of sonde ozone with Aura's Microwave Limb Sounder (MLS) are used to assess the stability of stratospheric ozone. This paper provides a comprehensive examination of global ozonesonde network data stability and accuracy since 2004 in light of the sudden post‐2013 TCO “dropoff” of ∼3%–4% that was reported previously at select stations (Stauffer et al., 2020, https://doi.org/10.1029/2019GL086791). Comparisons with Aura OMI TCO averaged across the network of 60 stations are stable within about ±2% over the past 18 years. Sonde TCO has similar stability compared to three other TCO satellite instruments, and the stratospheric ozone measurements average to within ±5% of MLS from 50 to 10 hPa. Thus, sonde data are reliable for trends, but with a caveat applied for a subset of dropoff stations in the tropics and subtropics. The dropoff is associated with only one of two major ECC instrument types. A detailed examination of ECC serial numbers pinpoints the timing of the dropoff. However, we find that overall, ozonesonde data are stable and accurate compared to independent measurements over the past two decades.
- 21 October 2022
- Published by American Geophysical Union (AGU) in Earth and Space Science
- Vol. 9 (10)
Top Cited PapersOpen AccessAn Examination of the Recent Stability of Ozonesonde Global Network Data
The recent Assessment of Standard Operating Procedures for Ozonesondes 2.0 (WMO/GAW Report #268) addressed questions of homogeneity and long‐term stability in global electrochemical concentration cell (ECC) ozone sounding network time series. Among its recommendations was adoption of a standard for evaluating data quality in ozonesonde time series. Total column ozone (TCO) derived from the sondes compared to TCO from Aura's Ozone Monitoring Instrument (OMI) is a primary quality indicator. Comparisons of sonde ozone with Aura's Microwave Limb Sounder (MLS) are used to assess the stability of stratospheric ozone. This paper provides a comprehensive examination of global ozonesonde network data stability and accuracy since 2004 in light of the sudden post‐2013 TCO “dropoff” of ∼3%–4% that was reported previously at select stations (Stauffer et al., 2020, https://doi.org/10.1029/2019GL086791). Comparisons with Aura OMI TCO averaged across the network of 60 stations are stable within about ±2% over the past 18 years. Sonde TCO has similar stability compared to three other TCO satellite instruments, and the stratospheric ozone measurements average to within ±5% of MLS from 50 to 10 hPa. Thus, sonde data are reliable for trends, but with a caveat applied for a subset of dropoff stations in the tropics and subtropics. The dropoff is associated with only one of two major ECC instrument types. A detailed examination of ECC serial numbers pinpoints the timing of the dropoff. However, we find that overall, ozonesonde data are stable and accurate compared to independent measurements over the past two decades.
- Open Access
- 10 June 2022
- Published by Wiley in ESS Open Archive
An Examination of the Recent Stability of Ozonesonde Global Network Data
The recent Assessment of Standard Operating Procedures for OzoneSondes (ASOPOS 2.0; WMO/GAW Report #268) addressed questions of homogeneity and long-term stability in global electrochemical concentration cell (ECC) ozone sounding network time series. Among its recommendations was adoption of a standard for evaluating data quality in ozonesonde time-series. Total column ozone (TCO) derived from the sondes compared to TCO from Aura’s Ozone Monitoring Instrument (OMI) is a primary quality indicator. Comparisons of sonde ozone with Aura’s Microwave Limb Sounder (MLS) are used to assess the stability of stratospheric ozone. This paper provides a comprehensive examination of global ozonesonde network data stability and accuracy since 2004. Comparisons with Aura OMI TCO averaged across the network of 60 stations are stable within about +/-2% over the past 18 years. Sonde TCO has similar stability compared to three other TCO satellite instruments, and the stratospheric ozone measurements average to within +/-5% of MLS from 50 to 10 hPa. Thus, sonde data are reliable for trends, but with a caveat applied for a subset of stations in the tropics and subtropics for which a sudden post-2013 TCO “dropoff” of ~3-4% was reported previously (Stauffer et al., 2020). The dropoff is associated with only one of two major ECC instrument types. A detailed examination of ECC serial numbers pinpoints the timing of the dropoff. However, we find that overall, ozonesonde data are stable and accurate compared to independent measurements over the past two decades.
- 10 June 2022
- Published by Wiley in ESS Open Archive
Open AccessAn Examination of the Recent Stability of Ozonesonde Global Network Data
The recent Assessment of Standard Operating Procedures for OzoneSondes (ASOPOS 2.0; WMO/GAW Report #268) addressed questions of homogeneity and long-term stability in global electrochemical concentration cell (ECC) ozone sounding network time series. Among its recommendations was adoption of a standard for evaluating data quality in ozonesonde time-series. Total column ozone (TCO) derived from the sondes compared to TCO from Aura’s Ozone Monitoring Instrument (OMI) is a primary quality indicator. Comparisons of sonde ozone with Aura’s Microwave Limb Sounder (MLS) are used to assess the stability of stratospheric ozone. This paper provides a comprehensive examination of global ozonesonde network data stability and accuracy since 2004. Comparisons with Aura OMI TCO averaged across the network of 60 stations are stable within about +/-2% over the past 18 years. Sonde TCO has similar stability compared to three other TCO satellite instruments, and the stratospheric ozone measurements average to within +/-5% of MLS from 50 to 10 hPa. Thus, sonde data are reliable for trends, but with a caveat applied for a subset of stations in the tropics and subtropics for which a sudden post-2013 TCO “dropoff” of ~3-4% was reported previously (Stauffer et al., 2020). The dropoff is associated with only one of two major ECC instrument types. A detailed examination of ECC serial numbers pinpoints the timing of the dropoff. However, we find that overall, ozonesonde data are stable and accurate compared to independent measurements over the past two decades.
- Open Access
- 4 March 2022
- Published by American Geophysical Union (AGU) in AGU Advances
- Vol. 3 (2)
Impact of the COVID‐19 Economic Downturn on Tropospheric Ozone Trends: An Uncertainty Weighted Data Synthesis for Quantifying Regional Anomalies Above Western North America and Europe
This study quantifies the association between the COVID‐19 economic downturn and 2020 tropospheric ozone anomalies above Europe and western North America, and their impact on long‐term trends. Anomaly detection for an atmospheric time series is usually carried out by identifying potentially aberrant data points relative to climatological values. However, detecting ozone anomalies from sparsely sampled ozonesonde profiles (once per week at most sites) is challenging due to ozone's high temporal variability. We first demonstrate the challenges for summarizing regional trends based on independent time series from multiple nearby ozone profiling stations. We then propose a novel regional‐scale anomaly detection framework based on generalized additive mixed models, which accounts for the sampling frequency and inherent data uncertainty associated with each vertical profile data set, measured by ozonesondes, lidar or commercial aircraft. This method produces a long‐term monthly time series with high vertical resolution that reports ozone anomalies from the surface to the middle‐stratosphere under a unified framework, which can be used to quantify the regional‐scale ozone anomalies during the COVID‐19 economic downturn. By incorporating extensive commercial aircraft data and frequently sampled ozonesonde profiles above Europe, we show that the complex interannual variability of ozone can be adequately captured by our modeling approach. The results show that free tropospheric ozone negative anomalies in 2020 are the most profound since the benchmark year of 1994 for both Europe and western North America, and positive trends over 1994–2019 are diminished in both regions by the 2020 anomalies.
- 4 March 2022
- Published by American Geophysical Union (AGU) in AGU Advances
- Vol. 3 (2)
Open AccessImpact of the COVID‐19 Economic Downturn on Tropospheric Ozone Trends: An Uncertainty Weighted Data Synthesis for Quantifying Regional Anomalies Above Western North America and Europe
This study quantifies the association between the COVID‐19 economic downturn and 2020 tropospheric ozone anomalies above Europe and western North America, and their impact on long‐term trends. Anomaly detection for an atmospheric time series is usually carried out by identifying potentially aberrant data points relative to climatological values. However, detecting ozone anomalies from sparsely sampled ozonesonde profiles (once per week at most sites) is challenging due to ozone's high temporal variability. We first demonstrate the challenges for summarizing regional trends based on independent time series from multiple nearby ozone profiling stations. We then propose a novel regional‐scale anomaly detection framework based on generalized additive mixed models, which accounts for the sampling frequency and inherent data uncertainty associated with each vertical profile data set, measured by ozonesondes, lidar or commercial aircraft. This method produces a long‐term monthly time series with high vertical resolution that reports ozone anomalies from the surface to the middle‐stratosphere under a unified framework, which can be used to quantify the regional‐scale ozone anomalies during the COVID‐19 economic downturn. By incorporating extensive commercial aircraft data and frequently sampled ozonesonde profiles above Europe, we show that the complex interannual variability of ozone can be adequately captured by our modeling approach. The results show that free tropospheric ozone negative anomalies in 2020 are the most profound since the benchmark year of 1994 for both Europe and western North America, and positive trends over 1994–2019 are diminished in both regions by the 2020 anomalies.
- Open Access
- 23 August 2021
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 14 (8) , 5757-5769
A fully automated Dobson sun spectrophotometer for total column ozone and Umkehr measurements
The longest ozone column measurement series are based on the Dobson sun spectrophotometers developed in the 1920s by Prof. G. B. W. Dobson. These ingenious and robustly designed instruments still constitute an important part of the global network presently. However, the Dobson sun spectrophotometer requires manual operation, which has led to the discontinuation of its use at many stations, thus disrupting long-term records of observation. To overcome this problem, MeteoSwiss developed a fully automated version of the Dobson spectrophotometer. The description of the data acquisition and automated control of the instrument is presented here with some technical details. The results of different tests performed regularly to assess the instrument's good working conditions are illustrated and discussed. Compared to manual operation, automation results in a higher number of daily measurements with lower random error and additional housekeeping information to characterize the measuring conditions. The automated Dobson instrument allows for continuous observation of the ozone column with a resolution of ∼ 1 DU under clear-sky conditions.
- 23 August 2021
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 14 (8) , 5757-5769
Open AccessA fully automated Dobson sun spectrophotometer for total column ozone and Umkehr measurements
The longest ozone column measurement series are based on the Dobson sun spectrophotometers developed in the 1920s by Prof. G. B. W. Dobson. These ingenious and robustly designed instruments still constitute an important part of the global network presently. However, the Dobson sun spectrophotometer requires manual operation, which has led to the discontinuation of its use at many stations, thus disrupting long-term records of observation. To overcome this problem, MeteoSwiss developed a fully automated version of the Dobson spectrophotometer. The description of the data acquisition and automated control of the instrument is presented here with some technical details. The results of different tests performed regularly to assess the instrument's good working conditions are illustrated and discussed. Compared to manual operation, automation results in a higher number of daily measurements with lower random error and additional housekeeping information to characterize the measuring conditions. The automated Dobson instrument allows for continuous observation of the ozone column with a resolution of ∼ 1 DU under clear-sky conditions.
- Open Access
- 7 June 2021
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 14 (6) , 4203-4217
Quality assessment of Dobson spectrophotometers for ozone column measurements before and after automation at Arosa and Davos
The longest ozone column measurement series are based on the Dobson sun spectrophotometers developed in the 1920s by Gordon B. W. Dobson. These instruments still constitute an important part of the World Meteorological Organization's global network due to their optical qualities and ruggedness. The primary drawback of this instrument is the effort needed for its manual operation. In industrialized and some less developed countries, most stations have made the choice to replace the Dobson by the automated Brewer sun spectrophotometers, but some are still relying on the Dobson instrument. One of them is the Arosa station where both instrument types are run in parallel. Here, an automated version of the Dobson instrument was developed and implemented recently. In the present paper, the results of the analysis of simultaneous measurements from pairs of Dobson instruments that were either collocated at Arosa or Davos or operated one at each location are presented for four distinct time periods: 1992–2012 – manual vs. manual operation of collocated Dobson instruments (MMC); 2012–2013 – manual vs. automated operation of collocated Dobson instruments (MAC); 2012–2019 – automated vs. automated operation of collocated Dobson instruments (AAC); 2016–2019 – automated vs. automated operation of distant Dobson instruments (AAD). The direct comparison of two instruments using the standard operation procedure during the MMC period gives a metric necessary to validate the automated version of Dobson instruments. The direct comparison of two collocated instruments using the standard manual operation procedure reveals random differences of coincident observations with a standard deviation of ∼ 0.45 % and monthly mean differences between −1.0 % and +0.8 %. In most cases the observed biases are not statistically significant. The same analysis of two automated Dobson instruments yields significantly smaller standard deviation of ∼ 0.25 % and biases of between −0.7 % and 0.8 %. This demonstrates that the repeatability has improved with the automation, while the systematic differences are only marginally smaller. The analysis of the AAD period of coincident measurements from the distant sites Arosa and Davos reveals a small positive bias (not significant) compatible with the 250 m altitude difference. The description of the automated data acquisition and control of the Dobson instrument is presented in a separate paper (Stübi et al., 2020).
- 7 June 2021
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 14 (6) , 4203-4217
Open AccessQuality assessment of Dobson spectrophotometers for ozone column measurements before and after automation at Arosa and Davos
The longest ozone column measurement series are based on the Dobson sun spectrophotometers developed in the 1920s by Gordon B. W. Dobson. These instruments still constitute an important part of the World Meteorological Organization's global network due to their optical qualities and ruggedness. The primary drawback of this instrument is the effort needed for its manual operation. In industrialized and some less developed countries, most stations have made the choice to replace the Dobson by the automated Brewer sun spectrophotometers, but some are still relying on the Dobson instrument. One of them is the Arosa station where both instrument types are run in parallel. Here, an automated version of the Dobson instrument was developed and implemented recently. In the present paper, the results of the analysis of simultaneous measurements from pairs of Dobson instruments that were either collocated at Arosa or Davos or operated one at each location are presented for four distinct time periods: 1992–2012 – manual vs. manual operation of collocated Dobson instruments (MMC); 2012–2013 – manual vs. automated operation of collocated Dobson instruments (MAC); 2012–2019 – automated vs. automated operation of collocated Dobson instruments (AAC); 2016–2019 – automated vs. automated operation of distant Dobson instruments (AAD). The direct comparison of two instruments using the standard operation procedure during the MMC period gives a metric necessary to validate the automated version of Dobson instruments. The direct comparison of two collocated instruments using the standard manual operation procedure reveals random differences of coincident observations with a standard deviation of ∼ 0.45 % and monthly mean differences between −1.0 % and +0.8 %. In most cases the observed biases are not statistically significant. The same analysis of two automated Dobson instruments yields significantly smaller standard deviation of ∼ 0.25 % and biases of between −0.7 % and 0.8 %. This demonstrates that the repeatability has improved with the automation, while the systematic differences are only marginally smaller. The analysis of the AAD period of coincident measurements from the distant sites Arosa and Davos reveals a small positive bias (not significant) compatible with the 250 m altitude difference. The description of the automated data acquisition and control of the Dobson instrument is presented in a separate paper (Stübi et al., 2020).
- Open Access
- 26 February 2021
- Published by American Geophysical Union (AGU) in Geophysical Research Letters
- Vol. 48 (5)
COVID‐19 Crisis Reduces Free Tropospheric Ozone Across the Northern Hemisphere
Throughout spring and summer 2020, ozone stations in the northern extratropics recorded unusually low ozone in the free troposphere. From April to August, and from 1 to 8 kilometers altitude, ozone was on average 7% (≈4 nmol/mol) below the 2000–2020 climatological mean. Such low ozone, over several months, and at so many stations, has not been observed in any previous year since at least 2000. Atmospheric composition analyses from the Copernicus Atmosphere Monitoring Service and simulations from the NASA GMI model indicate that the large 2020 springtime ozone depletion in the Arctic stratosphere contributed less than one‐quarter of the observed tropospheric anomaly. The observed anomaly is consistent with recent chemistry‐climate model simulations, which assume emissions reductions similar to those caused by the COVID‐19 crisis. COVID‐19 related emissions reductions appear to be the major cause for the observed reduced free tropospheric ozone in 2020.
- 26 February 2021
- Published by American Geophysical Union (AGU) in Geophysical Research Letters
- Vol. 48 (5)
Open AccessCOVID‐19 Crisis Reduces Free Tropospheric Ozone Across the Northern Hemisphere
Throughout spring and summer 2020, ozone stations in the northern extratropics recorded unusually low ozone in the free troposphere. From April to August, and from 1 to 8 kilometers altitude, ozone was on average 7% (≈4 nmol/mol) below the 2000–2020 climatological mean. Such low ozone, over several months, and at so many stations, has not been observed in any previous year since at least 2000. Atmospheric composition analyses from the Copernicus Atmosphere Monitoring Service and simulations from the NASA GMI model indicate that the large 2020 springtime ozone depletion in the Arctic stratosphere contributed less than one‐quarter of the observed tropospheric anomaly. The observed anomaly is consistent with recent chemistry‐climate model simulations, which assume emissions reductions similar to those caused by the COVID‐19 crisis. COVID‐19 related emissions reductions appear to be the major cause for the observed reduced free tropospheric ozone in 2020.
- Open Access
- 10 December 2020
- Published by Copernicus GmbH in EGUsphere
- Vol. 2020, 1-22
A fully Automated Dobson Sun Spectrophotometer for total column ozone and Umkehr measurements
The longest ozone column measurements series are based on the Dobson sun spectrophotometers developed in the 1920s by Prof. G. B. W. Dobson. These ingenious and robustly designed instruments still constitute an important part of the global network presently. However, the Dobson sun spectrophotometer needs manual operation which leads to the discontinuation of its use at many stations. To overcome this problem, MeteoSwiss developed a fully automated version of the Dobson spectrophotometer. The description of the data acquisition and automated control of the instrument is presented here with some technical details. The results of different tests performed regularly to control the instrument good working operation are illustrated and discussed. Compared to manual operation, the automation results in higher frequency measurements with lower random error and additional housekeeping information to characterise the measuring conditions. The automated Dobson instrument allows a continuous observation of the ozone column with a resolution of ~1 DU unit under clear sky conditions.
- 10 December 2020
- Published by Copernicus GmbH in EGUsphere
- Vol. 2020, 1-22
Open AccessA fully Automated Dobson Sun Spectrophotometer for total column ozone and Umkehr measurements
The longest ozone column measurements series are based on the Dobson sun spectrophotometers developed in the 1920s by Prof. G. B. W. Dobson. These ingenious and robustly designed instruments still constitute an important part of the global network presently. However, the Dobson sun spectrophotometer needs manual operation which leads to the discontinuation of its use at many stations. To overcome this problem, MeteoSwiss developed a fully automated version of the Dobson spectrophotometer. The description of the data acquisition and automated control of the instrument is presented here with some technical details. The results of different tests performed regularly to control the instrument good working operation are illustrated and discussed. Compared to manual operation, the automation results in higher frequency measurements with lower random error and additional housekeeping information to characterise the measuring conditions. The automated Dobson instrument allows a continuous observation of the ozone column with a resolution of ~1 DU unit under clear sky conditions.
- Open Access
- 8 December 2020
- Published by Wiley in ESS Open Archive
Did the COVID-19 Crisis Reduce Free Tropospheric Ozone across the Northern Hemisphere?
Throughout spring and summer 2020, ozone stations in the northern extratropics recorded unusually low ozone in the free troposphere. From April to August, and from 1 to 8 kilometers altitude, ozone was on average 7% (~4 ppbv) below the 2000 to 2020 climatological mean. Such low ozone, over several months, and at so many stations, has not been observed in any previous year since at least 2000. Atmospheric composition re-analyses from the Copernicus Atmosphere Monitoring Service and simulations from the NASA GMI model indicate that the large 2020 springtime ozone depletion in the Arctic stratosphere has contributed less than one quarter to the observed tropospheric anomaly. The observed anomaly is consistent with two recent model simulations, which assume emission reductions similar to those caused by the COVID-19 crisis. COVID-19 related emission reductions appear to be the major cause for the observed low free tropospheric ozone in 2020.
- 8 December 2020
- Published by Wiley in ESS Open Archive
Open AccessDid the COVID-19 Crisis Reduce Free Tropospheric Ozone across the Northern Hemisphere?
Throughout spring and summer 2020, ozone stations in the northern extratropics recorded unusually low ozone in the free troposphere. From April to August, and from 1 to 8 kilometers altitude, ozone was on average 7% (~4 ppbv) below the 2000 to 2020 climatological mean. Such low ozone, over several months, and at so many stations, has not been observed in any previous year since at least 2000. Atmospheric composition re-analyses from the Copernicus Atmosphere Monitoring Service and simulations from the NASA GMI model indicate that the large 2020 springtime ozone depletion in the Arctic stratosphere has contributed less than one quarter to the observed tropospheric anomaly. The observed anomaly is consistent with two recent model simulations, which assume emission reductions similar to those caused by the COVID-19 crisis. COVID-19 related emission reductions appear to be the major cause for the observed low free tropospheric ozone in 2020.