RTRalf J. O. Torgrip

Ralf J. O. Torgrip

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ralf J. O. Torgrip has a total of 36 co-authors. Here are the top co-authors by number of shared publications:

  • Erik Alm

    Stockholm University

    6 shared publications
  • Johan Lindberg

    AstraZeneca R&D Södertälje, Safety Assessment, Molecular Toxicology, Södertälje, Sweden

    6 shared publications
  • K. Magnus Åberg

    Stockholm University

    6 shared publications
  • Ina Schuppe-Koistinen

    AstraZeneca R&D Södertälje, Safety Assessment, Molecular Toxicology, Södertälje, Sweden

    5 shared publications
  • Bo Karlberg

    Department of Analytical Chemistry, BioSysteMetrics Group, Stockholm University, Stockholm, Sweden

    3 shared publications
  • Sven P. Jacobsson

    Department of Analytical Chemistry, BioSysteMetrics Group, Stockholm University, SE-106 91, Stockholm, Sweden, and Safety Assessment, Molecular Toxicology, and PAR&D, AstraZeneca R&D Södertälje, SE-151 85, Södertälje, Sweden

    3 shared publications

Latest Publications

  • Massifquant: open-source Kalman filter-based XC-MS isotope trace feature detection

    by Christopher J. Conley, Rob Smith, Ralf J. O. Torgrip, Ryan M. Taylor, Ralf Tautenhahn, John T. Prince

    Motivation: Isotope trace (IT) detection is a fundamental step for liquid or gas chromatography mass spectrometry (XC-MS) data analysis that faces a multitude of technical challenges on complex samples. The Kalman filter (KF) application to IT detection addresses some of these challenges; it discriminates closely eluting ITs in the m/z dimension, flexibly handles heteroscedastic m/z variances and does not bin the m/z axis. Yet, the behavior of this KF application has not been fully characterized, as no cost-free open-source implementation exists and incomplete evaluation standards for IT detection persist.


  • Organophosphate and phthalate esters in air and settled dust - a multi-location indoor study

    by C. Bergh, R. Torgrip, G. Emenius, C. Östman

    This paper reports the abundance in indoor air and dust of eleven organophosphate esters and six phthalate esters. Both groups of these semi-volatile compounds are widely incorporated as additives into plastic materials used in the indoor environment, thus contributing to indoor exposure to industrial chemicals. Thirty sampling sites representing three different indoor environments (private homes, day care centers, and workplaces) in the Stockholm area, Sweden, were selected to obtain representative concentration profiles in both ambient air and settled dust. Eight of the target organophosphate esters and all six phthalate esters were found in both air and dust samples at all locations. The phthalate esters were more abundant than the organophosphate esters, typically ten times higher total concentrations. Especially interesting were the high levels of tributoxyethyl phosphate in the day care centers, the relatively high levels of chlorinated organophosphate esters in the air of workplaces and the overall high levels of diethylhexyl phthalate in dust. The air concentration profiles of the phosphate esters differed significantly between the three indoor environments, whereas the concentration profiles of the phthalate esters as well as their total concentrations were similar. The correlation between concentrations found in air and in dust was found to be weak. Organophosphate esters and phthalate esters are commonly used as additives in numerous building materials and consumer products. The use of these compounds is increasing, and phosphate and phthalate esters are to be regarded as ubiquitous contaminants in the indoor environment. These compounds comprise a number of different compounds that have been associated with biologic effects in animal studies as well as in humans. Thus, it is of concern to increase the knowledge about human exposure of these compounds because of their presence in indoor air. In this paper, thirty indoor environments have been surveyed with respect to seventeen of the most abundant of these compounds.


  • Simultaneous selective detection of organophosphate and phthalate esters using gas chromatography with positive ion chemical ionization tandem mass spectrometry and its application to indoor air and dust

    by Caroline Bergh, Ralf Torgrip, Conny Östman

    A selective and sensitive method for the simultaneous determination of 14 organophosphate and six phthalate esters using gas chromatography (GC) and mass spectrometry (MS) is presented. Both of these compound classes are frequently found in the indoor environment due to their use as bulk additives in numerous polymers, consumer products and building materials. GC/MS utilizing positive ion chemical ionisation (PICI) in selected reaction monitoring (SRM) mode with isobutane as the reagent gas was found to be the best of the tested methods; it proved superior to electron ionisation (EI) in selected ion monitoring (SIM) mode and to PICI using methane as the reagent gas. The method was applied to indoor air samples collected by active air sampling using solid‐phase extraction (SPE) cartridges. Organophosphates and phthalates were simultaneously determined with method detection limits (MDLs) in the range of 0.1–47 ng m −3 . For most compounds the MDLs were ≤0.2 ng m −3 , but due to the presence of some of these ubiquitous indoor air pollutants in the blanks, significantly higher MDLs were observed for a few compounds. Finally, the method was also applied in the screening of a much more complex sample matrix, indoor dust. Copyright © 2010 John Wiley & Sons, Ltd.


  • Time-resolved biomarker discovery in 1H-NMR data using generalized fuzzy Hough transform alignment and parallel factor analysis

    by Erik Alm, Ralf J. O. Torgrip, K. Magnus Åberg, Ina Schuppe-Koistinen, Johan Lindberg

    This work addresses the subject of time-series analysis of comprehensive 1H-NMR data of biological origin. One of the problems with toxicological and efficacy studies is the confounding of correlation between the administered drug, its metabolites and the systemic changes in molecular dynamics, i.e., the flux of drug-related molecules correlates with the molecules of system regulation. This correlation poses a problem for biomarker mining since this confounding must be untangled in order to separate true biomarker molecules from dose-related molecules. One way of achieving this goal is to perform pharmacokinetic analysis. The difference in pharmacokinetic time profiles of different molecules can aid in the elucidation of the origin of the dynamics, this can even be achieved regardless of whether the identity of the molecule is known or not. This mode of analysis is the basis for metabonomic studies of toxicology and efficacy. One major problem concerning the analysis of 1H-NMR data generated from metabonomic studies is that of the peak positional variation and of peak overlap. These phenomena induce variance in the data, obscuring the true information content and are hence unwanted but hard to avoid. Here, we show that by using the generalized fuzzy Hough transform spectral alignment, variable selection, and parallel factor analysis, we can solve both the alignment and the confounding problem stated above. Using the outlined method, several different temporal concentration profiles can be resolved and the majority of the studied molecules and their respective fluxes can be attributed to these resolved kinetic profiles. The resolved time profiles hereby simplifies finding true biomarkers and bio-patterns for early detection of biological conditions as well as providing more detailed information about the studied biological system. The presented method represents a significant step forward in time-series analysis of biological 1H-NMR data as it provides almost full automation of the whole data analysis process and is able to analyze over 800 unique features per sample. The method is demonstrated using a 1H-NMR rat urine dataset from a toxicology study and is compared with a classical approach: COW alignment followed by bucketing.


  • A solution to the 1D NMR alignment problem using an extended generalized fuzzy Hough transform and mode support

    by Erik Alm, Ralf J. O. Torgrip, K. Magnus Åberg, Ina Schuppe-Koistinen, Johan Lindberg

    This paper approaches the problem of intersample peak correspondence in the context of later applying statistical data analysis techniques to 1D 1H-nuclear magnetic resonance (NMR) data. Any data analysis methodology will fail to produce meaningful results if the analyzed data table is not synchronized, i.e., each analyzed variable frequency (Hz) does not originate from the same chemical source throughout the entire dataset. This is typically the case when dealing with NMR data from biological samples. In this paper, we present a new state of the art for solving this problem using the generalized fuzzy Hough transform (GFHT). This paper describes significant improvements since the method was introduced for NMR datasets of plasma in Csenki et al. (Anal Bioanal Chem 389:875-885, 15) and is now capable of synchronizing peaks from more complex datasets such as urine as well as plasma data. We present a novel way of globally modeling peak shifts using principal component analysis, a new algorithm for calculating the transform and an effective peak detection algorithm. The algorithm is applied to two real metabonomic 1H-NMR datasets and the properties of the method are compared to bucketing. We implicitly prove that GFHT establishes the objectively true correspondence. Desirable features of the GFHT are: (1) intersample peak correspondence even if peaks change order on the frequency axis and (2) the method is symmetric with respect to the samples. From chaos to order: heatmaps of a H-NMR spectral segment prior and post sorting on one peak position. Post sorting sample order reveals that peak positions exhibits distinctive patterns which are modeled by the GFHT to establish correspondence.


  • The correspondence problem for metabonomics datasets

    by K. Magnus Åberg, Erik Alm, Ralf J. O. Torgrip

    In metabonomics it is difficult to tell which peak is which in datasets with many samples. This is known as the correspondence problem. Data from different samples are not synchronised, i.e., the peak from one metabolite does not appear in exactly the same place in all samples. For datasets with many samples, this problem is nontrivial, because each sample contains hundreds to thousands of peaks that shift and are identified ambiguously. Statistical analysis of the data assumes that peaks from one metabolite are found in one column of a data table. For every error in the data table, the statistical analysis loses power and the risk of missing a biomarker increases. It is therefore important to solve the correspondence problem by synchronising samples and there is no method that solves it once and for all. In this review, we analyse the correspondence problem, discuss current state-of-the-art methods for synchronising samples, and predict the properties of future methods.


  • Feature detection and alignment of hyphenated chromatographic–mass spectrometric data

    by K. Magnus Åberg, Ralf J.O. Torgrip, Johan Kolmert, Ina Schuppe-Koistinen, Johan Lindberg


  • A note on normalization of biofluid 1D 1H-NMR data

    by R. J. O. Torgrip, K. M. Åberg, E. Alm, I. Schuppe-Koistinen, J. Lindberg