Alessandro Gherardi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alessandro Gherardi has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Bevilacqua
Department of Computer Science and Engineering (DISI), University of Bologna, 40126 Bologna, Italy
26 shared publications Ludovico Carozza
ARCES - Advanced Research Centre on Electronic Systems - University of Bologna, via Toffano 2/2 - 40125, Italy
7 shared publications- Filippo Piccinini
IRCCS Istituto Romagnolo per lo Studio dei Tumori (IRST) “Dino Amadori”, Meldola, Italy
4 shared publications - Ludovico Carozza
ARCES, Advanced Research Center on Electronic Systems - University of Bologna, via Toffano 2/2 - 40125 Bologna, ITALY
3 shared publications Roberto Guerrieri
ARCES (Advanced Research Center on Electronic Systems) – University of Bologna, via Toffano 2/2, 40125 Bologna, Italy
3 shared publications- Enrico Lucarelli
Osteoncology, Bone and Soft Tissue Sarcomas and Innovative Therapies Unit, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy
2 shared publications
Latest Publications
- Open Access
- 19 April 2025
- Published by Elsevier in Laboratory Investigation
- Vol. 105 (8) , 104178
Computer-Based Detection of Colorectal Serrated Lesions: Digital Flatness, a Novel Metric Designed for Whole-Slide Images
- 19 April 2025
- Published by Elsevier in Laboratory Investigation
- Vol. 105 (8) , 104178
Open AccessComputer-Based Detection of Colorectal Serrated Lesions: Digital Flatness, a Novel Metric Designed for Whole-Slide Images
- 6 January 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 18 (4) , 1413-1422
Manual Stage Acquisition and Interactive Display of Digital Slides in Histopathology
More powerful PC architectures, high-resolution cameras working at increasing frame rates, and more and more accurate motorized microscopes have boosted new applications in the field of biomedicine and medical imaging. In histopathology, the use of digital slides (DSs) imaging through dedicated hardware for digital pathology is increasing for several reasons: digital annotation of suspicious lesions, recorded clinical history, and telepathology as a collaborative environment. In this paper, we propose the first method known in the literature for real-time whole slide acquisition and displaying conceived for conventional nonautomated microscopes. Differently from DS scanner, our software enables biologists and histopathologists to build and view the DS in real time while inspecting the sample, as they are accustomed to. In addition, since our approach is compliant with existing common microscope positions, provided with camera and PC, this could contribute to disseminate the whole slide technology in the majority of small labs not endowed with DS hardware facilities. Experiments performed with different histologic specimens (referring to tumor tissues of different body parts as well as to tumor cells), acquired under different setup conditions and devices, prove the effectiveness of our approach both in terms of quality and speed performances.
- 6 January 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 18 (4) , 1413-1422
Manual Stage Acquisition and Interactive Display of Digital Slides in Histopathology
More powerful PC architectures, high-resolution cameras working at increasing frame rates, and more and more accurate motorized microscopes have boosted new applications in the field of biomedicine and medical imaging. In histopathology, the use of digital slides (DSs) imaging through dedicated hardware for digital pathology is increasing for several reasons: digital annotation of suspicious lesions, recorded clinical history, and telepathology as a collaborative environment. In this paper, we propose the first method known in the literature for real-time whole slide acquisition and displaying conceived for conventional nonautomated microscopes. Differently from DS scanner, our software enables biologists and histopathologists to build and view the DS in real time while inspecting the sample, as they are accustomed to. In addition, since our approach is compliant with existing common microscope positions, provided with camera and PC, this could contribute to disseminate the whole slide technology in the majority of small labs not endowed with DS hardware facilities. Experiments performed with different histologic specimens (referring to tumor tissues of different body parts as well as to tumor cells), acquired under different setup conditions and devices, prove the effectiveness of our approach both in terms of quality and speed performances.
- 29 March 2013
- Published by SPIE-Intl Soc Optical Eng
- p. 86760W-86760W-8
Computer assisted detection of regions of interest in histopathology using a hybrid supervised and unsupervised approach
- 29 March 2013
- Published by SPIE-Intl Soc Optical Eng
- p. 86760W-86760W-8
Computer assisted detection of regions of interest in histopathology using a hybrid supervised and unsupervised approach
- Open Access
- 1 March 2013
- Published by Elsevier in Journal of Pathology Informatics
- Vol. 4 (2) , 9
Real-time whole slide mosaicing for non-automated microscopes in histopathology analysis
- 1 March 2013
- Published by Elsevier in Journal of Pathology Informatics
- Vol. 4 (2) , 9
Open AccessReal-time whole slide mosaicing for non-automated microscopes in histopathology analysis
- Open Access
- 15 November 2012
- Published by Spandidos Publications in International Journal of Oncology
- Vol. 42 (1) , 118-126
Protein kinase B/AKT isoform 2 drives migration of human mesenchymal stem cells
This study was designed to investigate the migratory behavior of adult human mesenchymal stem cells (MSC) and the underlying mechanism. Cell migration was assessed by transwell, wound healing and time-lapse in vivo motility assays. Pharmacological inhibitors were used to determine the potential mechanism responsible for cell migration and invasion. The tests that were implemented revealed that MSC were fairly migratory. Protein kinase B (AKT) was strongly activated at the basal level. Through our analyses we demonstrated that pharmacological inactivation of AKT2 but not AKT1 significantly decreased cell migration and invasion. Although preliminary, collectively our results indicate that AKT2 activation plays a critical role in enabling MSC migration.
- 15 November 2012
- Published by Spandidos Publications in International Journal of Oncology
- Vol. 42 (1) , 118-126
Open AccessProtein kinase B/AKT isoform 2 drives migration of human mesenchymal stem cells
This study was designed to investigate the migratory behavior of adult human mesenchymal stem cells (MSC) and the underlying mechanism. Cell migration was assessed by transwell, wound healing and time-lapse in vivo motility assays. Pharmacological inhibitors were used to determine the potential mechanism responsible for cell migration and invasion. The tests that were implemented revealed that MSC were fairly migratory. Protein kinase B (AKT) was strongly activated at the basal level. Through our analyses we demonstrated that pharmacological inactivation of AKT2 but not AKT1 significantly decreased cell migration and invasion. Although preliminary, collectively our results indicate that AKT2 activation plays a critical role in enabling MSC migration.
- 17 August 2012
- Published by Wiley in Journal of Microscopy
- Vol. 248 (1) , 6-22
Multi‐image based method to correct vignetting effect in light microscopy images
Summary: Vignetting is the radial attenuation effect of the image's brightness intensity from the center of the optical axis to the edges. To perform quantitative image analyses it is mandatory to take into account this effect, intrinsic of the acquisition system. Many image processing steps, such as segmentation and object tracking, are strongly affected by vignetting and the effect becomes particularly evident in mosaicing. The most common approach to compensate the attenuation of the image's brightness intensity is to estimate the vignetting function from a homogeneous reference object, typically an empty field, and to use it to normalize the images acquired under the same microscope set‐up conditions. However, several reasons lead to the use of image‐based methods to estimate the vignetting function from the images themselves. In this work, we propose an effective multi‐image based method suitable for real‐time applications. It is designed to correct vignetting in wide field light microscopy images. The vignetting function is computed stemming from a background built incrementally from the proposed background segmentation algorithm, validated on several manually segmented images. The extensive experiments carried out using cell cultures, histological samples and synthetic images prove that our method almost always yields the best results and in worst cases are comparable to those achieved by using homogeneous reference objects.
- 17 August 2012
- Published by Wiley in Journal of Microscopy
- Vol. 248 (1) , 6-22
Multi‐image based method to correct vignetting effect in light microscopy images
Summary: Vignetting is the radial attenuation effect of the image's brightness intensity from the center of the optical axis to the edges. To perform quantitative image analyses it is mandatory to take into account this effect, intrinsic of the acquisition system. Many image processing steps, such as segmentation and object tracking, are strongly affected by vignetting and the effect becomes particularly evident in mosaicing. The most common approach to compensate the attenuation of the image's brightness intensity is to estimate the vignetting function from a homogeneous reference object, typically an empty field, and to use it to normalize the images acquired under the same microscope set‐up conditions. However, several reasons lead to the use of image‐based methods to estimate the vignetting function from the images themselves. In this work, we propose an effective multi‐image based method suitable for real‐time applications. It is designed to correct vignetting in wide field light microscopy images. The vignetting function is computed stemming from a background built incrementally from the proposed background segmentation algorithm, validated on several manually segmented images. The extensive experiments carried out using cell cultures, histological samples and synthetic images prove that our method almost always yields the best results and in worst cases are comparable to those achieved by using homogeneous reference objects.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4633 (1094687X) , 6166-6169
Vignetting correction by exploiting an optical microscopy image sequence
Vignetting is one of the most common problem that may affect digital imaging. The effect becomes particularly evident when images are stitched together to increase the camera's field of view (e.g., when building a mosaic), where it can lead to errors in automatic analyses. To correct the effect, the most common approach is to acquire an empty field image in advance that is used later to perform a flat field correction on every subsequently acquired image. However, in several cases, such as when dealing with off-line images or with real time acquisitions, this is not a viable option. The method we propose relies on a non parametric model to characterize in real time the vignetting function from the specimen itself, by using our foreground/background segmentation algorithm. The function is computed over a background built incrementally, detecting regions free of objects of interest. The experiments carried out using cell cultures and histological samples prove that our method yields results at least comparable to those achieved by using empty field.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4633 (1094687X) , 6166-6169
Vignetting correction by exploiting an optical microscopy image sequence
Vignetting is one of the most common problem that may affect digital imaging. The effect becomes particularly evident when images are stitched together to increase the camera's field of view (e.g., when building a mosaic), where it can lead to errors in automatic analyses. To correct the effect, the most common approach is to acquire an empty field image in advance that is used later to perform a flat field correction on every subsequently acquired image. However, in several cases, such as when dealing with off-line images or with real time acquisitions, this is not a viable option. The method we propose relies on a non parametric model to characterize in real time the vignetting function from the specimen itself, by using our foreground/background segmentation algorithm. The function is computed over a background built incrementally, detecting regions free of objects of interest. The experiments carried out using cell cultures and histological samples prove that our method yields results at least comparable to those achieved by using empty field.
- 1 April 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Illumination field estimation through background detection in optical microscopy
Automated microscopic image analysis techniques are increasingly gaining attention in the field of biological imaging. The success of these applications mostly depends on the earlier image processing steps applied to the acquired images, aiming at enhancing image content while performing noise and artifacts removal. One such artifact is the vignetting effect that in general occurs in most imaging sensors due to an uneven illumination of the scene being imaged. As a consequence, images are usually lighter near the optical center and darker at image borders. This effect is particularly evident when stitching images into a mosaic in order to increase the field of view of the microscope. The existing approaches deal with either the parametric model of the known light distribution or the estimation of the illumination field based on just one image or a sequence of empty-field images. These approaches are only feasible when the acquisition apparatus is at one's disposal. We propose a non parametric and general purpose approach, without using prior information about the light distribution, where the illumination field is estimated from the background, that is built automatically stemming from a sequence of images containing even the objects of interest.
- 1 April 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Illumination field estimation through background detection in optical microscopy
Automated microscopic image analysis techniques are increasingly gaining attention in the field of biological imaging. The success of these applications mostly depends on the earlier image processing steps applied to the acquired images, aiming at enhancing image content while performing noise and artifacts removal. One such artifact is the vignetting effect that in general occurs in most imaging sensors due to an uneven illumination of the scene being imaged. As a consequence, images are usually lighter near the optical center and darker at image borders. This effect is particularly evident when stitching images into a mosaic in order to increase the field of view of the microscope. The existing approaches deal with either the parametric model of the known light distribution or the estimation of the illumination field based on just one image or a sequence of empty-field images. These approaches are only feasible when the acquisition apparatus is at one's disposal. We propose a non parametric and general purpose approach, without using prior information about the light distribution, where the illumination field is estimated from the background, that is built automatically stemming from a sequence of images containing even the objects of interest.
- 1 January 2011
- Published by Springer Nature
- p. 404-413
A Simulation Framework to Assess Pattern Matching Algorithms in a Space Mission
- 1 January 2011
- Published by Springer Nature
- p. 404-413
A Simulation Framework to Assess Pattern Matching Algorithms in a Space Mission
- 29 March 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 59 (10) , 2630-2638
An Automatic System for the Real-Time Characterization of Vehicle Headlamp Beams Exploiting Image Analysis
A vehicle's headlamp orientation and luminous and geometrical beam properties are a matter that is strictly ruled by the European Commission for transportation. To test the headlamps, a test system is usually manually aligned to the vehicle, and the human being has the definite opinion even on the beam-related measures. This paper presents a fully automatic system that exploits vision-based technology to extract the geometric parameters of the light profiles that are projected by vehicle headlamps in real time. The 3-D orientation of the longitudinal axis of the vehicle is recovered using stereoscopy. Furthermore, image analysis is used to automatically characterize the shadow-light border of a beam profile, as it would be perceived by an experienced human operator. A locally adaptive thresholding algorithm allows our system to automatically adjust to a wide range of light sources of different power. The alignment procedure and the beam characterization algorithm have been assessed through proper measuring apparatus that is capable of yielding accurate ground-truth data. In particular, the headlamp has been mounted on a special three-axis numerical control unit whose accuracy has been previously assessed, again using image analysis. Experimental results, which are carried out on a large number of different headlamps, show that our method is able to achieve accurate measurements in compliance with current regulations. Finally, it is worth remarking that our solution is fully automatic, and it just requires a simple setup procedure.
- 29 March 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 59 (10) , 2630-2638
An Automatic System for the Real-Time Characterization of Vehicle Headlamp Beams Exploiting Image Analysis
A vehicle's headlamp orientation and luminous and geometrical beam properties are a matter that is strictly ruled by the European Commission for transportation. To test the headlamps, a test system is usually manually aligned to the vehicle, and the human being has the definite opinion even on the beam-related measures. This paper presents a fully automatic system that exploits vision-based technology to extract the geometric parameters of the light profiles that are projected by vehicle headlamps in real time. The 3-D orientation of the longitudinal axis of the vehicle is recovered using stereoscopy. Furthermore, image analysis is used to automatically characterize the shadow-light border of a beam profile, as it would be perceived by an experienced human operator. A locally adaptive thresholding algorithm allows our system to automatically adjust to a wide range of light sources of different power. The alignment procedure and the beam characterization algorithm have been assessed through proper measuring apparatus that is capable of yielding accurate ground-truth data. In particular, the headlamp has been mounted on a special three-axis numerical control unit whose accuracy has been previously assessed, again using image analysis. Experimental results, which are carried out on a large number of different headlamps, show that our method is able to achieve accurate measurements in compliance with current regulations. Finally, it is worth remarking that our solution is fully automatic, and it just requires a simple setup procedure.