Shunsaku Goto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shunsaku Goto has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Tomotaka Ohshima
Neuroendovascular Therapy Center, Aichi Medical University, Aichi, Japan
6 shared publications Masahiro Nishihori
Department of Neurosurgery, Nagoya University Graduate School of Medicine, Aichi, Japan
4 shared publications- Taiki Yamamoto
Department of Neurosurgery, Kariya Toyota General Hospital, Kariya, Japan
4 shared publications Kojiro Ishikawa
Department of Neurosurgery, Kariya Toyota General Hospital, Kariya, Japan
3 shared publicationsKyozo Kato
Department of Neurosurgery, Kariya Toyota General Hospital, Kariya, Japan
3 shared publications- Takashi Izumi
Department of Neurosurgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
3 shared publications
Latest Publications
- 21 August 2025
- Published by SAGE Publications in Interventional Neuroradiology
Outcomes of stent-assisted coil embolization of intracranial aneurysms with a small parental vessel diameter
Background: Stent-assisted coil embolization (SACE) is widely used for treating cerebral aneurysms, particularly bifurcation aneurysms. Although stents are typically indicated for parent vessels larger than 2 mm, their use in small-diameter vessels ( 5.5 mm was identified as a risk factor for perioperative ischemic complications. Conclusion: SACE can be safely performed in patients with SD parent vessels without increasing ischemic complications. However, there was only a trend toward higher frequency of intraoperative thrombi in the SD group, highlighting the need for preventive measures and prompt intervention. Having a wide neck diameter > 5.5 mm was identified a risk factor for periprocedural ischemic complications in the SD group.
- 21 August 2025
- Published by SAGE Publications in Interventional Neuroradiology
Outcomes of stent-assisted coil embolization of intracranial aneurysms with a small parental vessel diameter
Background: Stent-assisted coil embolization (SACE) is widely used for treating cerebral aneurysms, particularly bifurcation aneurysms. Although stents are typically indicated for parent vessels larger than 2 mm, their use in small-diameter vessels ( 5.5 mm was identified as a risk factor for perioperative ischemic complications. Conclusion: SACE can be safely performed in patients with SD parent vessels without increasing ischemic complications. However, there was only a trend toward higher frequency of intraoperative thrombi in the SD group, highlighting the need for preventive measures and prompt intervention. Having a wide neck diameter > 5.5 mm was identified a risk factor for periprocedural ischemic complications in the SD group.
- 13 September 2021
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 28 (3) , 323-331
Evaluation of the differences in pressure applied to the vessel wall by different types of balloon remodeling microcatheters in an experimental model
Background: We examined compliance differences among balloon remodeling microcatheters, which have not been established previously. Methods: Straight and 120° angulated vascular models were created in a 3 mm diameter tube with 3 mm hole (vascular model A), a tube with a 4 mm hole (vascular model B), and a 4 mm diameter tube (vascular model C). We compared the pressure exerted when each balloon was herniated 1 or 2 mm between three compliant balloons (SHOURYU SR, TransForm C, and Scepter C) and four super-compliant balloons (HyperForm, SHOURYU HR, TransForm SC, and Scepter XC). Results: In vascular model A, there was a significant difference in the pressure exerted by compliant balloons and super-compliant balloons in both the straight and angulated models. In the straight model (1 and 2 mm), the lowest pressure was exerted by HyperForm (super-compliant balloons group) and SHOURYU SR (compliant balloons group). The lowest pressure was exerted in the angulated model by HyperForm (super-compliant balloons group) and Scepter C (compliant balloons group). The Scepter balloon exerted higher pressure in the straight model than other balloon remodeling microcatheters but less in the angulated model. In vascular model B, the pressure decreased in all balloons compared with model A. In vascular model C, the pressure increased in all balloons compared with model A. Conclusions: Pressure differed across balloon remodeling microcatheters. In addition, vessel shape and diameter, and hole size, affected the results. Our findings can help select balloon remodeling microcatheters.
- 13 September 2021
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 28 (3) , 323-331
Evaluation of the differences in pressure applied to the vessel wall by different types of balloon remodeling microcatheters in an experimental model
Background: We examined compliance differences among balloon remodeling microcatheters, which have not been established previously. Methods: Straight and 120° angulated vascular models were created in a 3 mm diameter tube with 3 mm hole (vascular model A), a tube with a 4 mm hole (vascular model B), and a 4 mm diameter tube (vascular model C). We compared the pressure exerted when each balloon was herniated 1 or 2 mm between three compliant balloons (SHOURYU SR, TransForm C, and Scepter C) and four super-compliant balloons (HyperForm, SHOURYU HR, TransForm SC, and Scepter XC). Results: In vascular model A, there was a significant difference in the pressure exerted by compliant balloons and super-compliant balloons in both the straight and angulated models. In the straight model (1 and 2 mm), the lowest pressure was exerted by HyperForm (super-compliant balloons group) and SHOURYU SR (compliant balloons group). The lowest pressure was exerted in the angulated model by HyperForm (super-compliant balloons group) and Scepter C (compliant balloons group). The Scepter balloon exerted higher pressure in the straight model than other balloon remodeling microcatheters but less in the angulated model. In vascular model B, the pressure decreased in all balloons compared with model A. In vascular model C, the pressure increased in all balloons compared with model A. Conclusions: Pressure differed across balloon remodeling microcatheters. In addition, vessel shape and diameter, and hole size, affected the results. Our findings can help select balloon remodeling microcatheters.
- 1 April 2019
- Published by Elsevier in World Neurosurgery
- Vol. 124, 22-24
Cardiac Arrest Induced by Carotid Sinus Reflex Activation During Flow-Diverter Stent Deployment
- 1 April 2019
- Published by Elsevier in World Neurosurgery
- Vol. 124, 22-24
Cardiac Arrest Induced by Carotid Sinus Reflex Activation During Flow-Diverter Stent Deployment
- 1 August 2018
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 27 (8) , 2187-2191
Efficacy of Carotid Artery Stenting by the Universal Protection Method
- 1 August 2018
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 27 (8) , 2187-2191
Efficacy of Carotid Artery Stenting by the Universal Protection Method
- 1 January 2018
- Published by Elsevier in World Neurosurgery
- Vol. 109, e468-e475
A Stent-Retrieving into an Aspiration Catheter with Proximal Balloon (ASAP) Technique: A Technique of Mechanical Thrombectomy
- 1 January 2018
- Published by Elsevier in World Neurosurgery
- Vol. 109, e468-e475
A Stent-Retrieving into an Aspiration Catheter with Proximal Balloon (ASAP) Technique: A Technique of Mechanical Thrombectomy
- 1 December 2017
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 26 (12) , 2788-2792
Midterm Follow-Up of 20 Consecutive Patients with Nonaneurysmal Subarachnoid Hemorrhage of Unknown Origin in a Single-Center: Two Cases of De Novo Development of Dural Arteriovenous Fistula
- 1 December 2017
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 26 (12) , 2788-2792
Midterm Follow-Up of 20 Consecutive Patients with Nonaneurysmal Subarachnoid Hemorrhage of Unknown Origin in a Single-Center: Two Cases of De Novo Development of Dural Arteriovenous Fistula
- Open Access
- 1 August 2017
- Vol. 79 (3) , 401-406
Experimental evaluation and training of stent clot retrieval: the confront clot scrambling method.
The introduction of stent retrievers has changed the methods used for acute intracranial thrombectomy, but the training approach has not been discussed enough. We, therefore, aimed to establish a simple skill up method which can be used to train anytime and anywhere with low costs. Also, we introduce our experimental confront clot scrambling method (CCSM) which makes a profitable visualization in how the stent retriever works. The CCSM involved a sham clot set in the middle of a polyvinyl chloride tube, after which two stent retrievers were navigated from each side before being simultaneously withdrawn with the same force. The stent that removes the sham clot is determined to have stronger clot retrieval ability. Several adjunctive techniques were also compared. The push and fluff adjunctive technique was the most effective among all the stents. Generally, the former deployed stent was stronger than later one. Therefore, the later deployed stent with the push and fluff technique lets us know whether the physician's maneuver worked well or not. CCSM could directly evaluate the ability of adjunctive techniques with each stent retriever and demonstrate the physicians' skills. Because the actual endovascular clot retrieval requires extreme fine maneuvers against invisible vessels, repeat training is very important especially in beginners.
- 1 August 2017
- Vol. 79 (3) , 401-406
Open AccessExperimental evaluation and training of stent clot retrieval: the confront clot scrambling method.
The introduction of stent retrievers has changed the methods used for acute intracranial thrombectomy, but the training approach has not been discussed enough. We, therefore, aimed to establish a simple skill up method which can be used to train anytime and anywhere with low costs. Also, we introduce our experimental confront clot scrambling method (CCSM) which makes a profitable visualization in how the stent retriever works. The CCSM involved a sham clot set in the middle of a polyvinyl chloride tube, after which two stent retrievers were navigated from each side before being simultaneously withdrawn with the same force. The stent that removes the sham clot is determined to have stronger clot retrieval ability. Several adjunctive techniques were also compared. The push and fluff adjunctive technique was the most effective among all the stents. Generally, the former deployed stent was stronger than later one. Therefore, the later deployed stent with the push and fluff technique lets us know whether the physician's maneuver worked well or not. CCSM could directly evaluate the ability of adjunctive techniques with each stent retriever and demonstrate the physicians' skills. Because the actual endovascular clot retrieval requires extreme fine maneuvers against invisible vessels, repeat training is very important especially in beginners.
- 1 January 2016
- Published by The Japanese Society for Neuroendovascular Therapy in Journal of Neuroendovascular Therapy
- Vol. 10 (4) , 196-200
Comparison of Clinical Outcomes Using 10 Coil Versus 14 Coil in Endovascular Coil Embolization for Small and Medium-sized Intracranial Aneurysms: Efficacy of 14 Coil
- 1 January 2016
- Published by The Japanese Society for Neuroendovascular Therapy in Journal of Neuroendovascular Therapy
- Vol. 10 (4) , 196-200
Comparison of Clinical Outcomes Using 10 Coil Versus 14 Coil in Endovascular Coil Embolization for Small and Medium-sized Intracranial Aneurysms: Efficacy of 14 Coil
- 1 August 2015
- Vol. 43 (8)
[A Case of Cavernous Sinus Dural Arteriovenous Fistula after Transverse-Sigmoid Sinus Dural Arteriovenous Fistula Treatment with Radical Transvenous Coil Embolization].
We report a case of cavernous sinus dural arteriovenous fistula (dAVF) that developed after the treatment of a transverse-sigmoid sinus dAVF using transvenous embolization (TVE).
- 1 August 2015
- Vol. 43 (8)
[A Case of Cavernous Sinus Dural Arteriovenous Fistula after Transverse-Sigmoid Sinus Dural Arteriovenous Fistula Treatment with Radical Transvenous Coil Embolization].
We report a case of cavernous sinus dural arteriovenous fistula (dAVF) that developed after the treatment of a transverse-sigmoid sinus dAVF using transvenous embolization (TVE).