Michael Georg Hansen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michael Georg Hansen has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Stephan Schiller
Heinrich-Heine-Universität Düsseldorf
6 shared publications Ingo Ernsting
Institut für Experimentalphysik, Heinrich-Heine-Universität Düsseldorf, 40225 Düsseldorf, Germany
3 shared publications- S. Alighanbari
Heinrich-Heine-Universität Düsseldorf
3 shared publications Stephan Schiller
Institut für Experimentalphysik, Heinrich-Heine-Universität Düsseldorf, 40225 Düsseldorf, Germany
3 shared publications- Vladimir I. Korobov
Joint Institute for Nuclear Research
3 shared publications A. Borodin
Institut für Experimentalphysik, Heinrich-Heine-Universität Düsseldorf, Universitätsstr. 1, 40225 Düsseldorf, Germany
2 shared publications
Latest Publications
- Open Access
- 30 May 2024
- Published by Springer Nature in Nature Physics
- Vol. 20 (6) , 1034
Author Correction: Proton–electron mass ratio by high-resolution optical spectroscopy of ion ensembles in the resolved-carrier regime
- 30 May 2024
- Published by Springer Nature in Nature Physics
- Vol. 20 (6) , 1034
Open AccessAuthor Correction: Proton–electron mass ratio by high-resolution optical spectroscopy of ion ensembles in the resolved-carrier regime
- Top Cited Papers
- 18 February 2021
- Published by Springer Nature in Nature Physics
- Vol. 17 (5) , 569-573
Proton–electron mass ratio by high-resolution optical spectroscopy of ion ensembles in the resolved-carrier regime
- 18 February 2021
- Published by Springer Nature in Nature Physics
- Vol. 17 (5) , 569-573
Top Cited PapersProton–electron mass ratio by high-resolution optical spectroscopy of ion ensembles in the resolved-carrier regime
- 21 December 2018
- Published by American Physical Society (APS) in Physical Review A
- Vol. 98 (6) , 062516
Characteristics of long-lived persistent spectral holes in : at 1.2 KProperties of persistent spectral holes (SHs) relevant for frequency metrology have been investigated in the system at crystallographic site 1 and a temperature of 1.2 K. Hole linewidths as small as 0.6 kHz have been reliably achieved. The theoretically predicted dependence of the frequency shift with temperature has been confirmed with high precision. The thermal hysteresis of the SH frequency between 1.15 and 4.1 K was measured to be less than fractionally. After initially burning a large ensemble of SHs, their properties were studied on long time scales by probing different subsets at different times. SHs could still be observed 49 days after burning if not interrogated in the meantime. During this time, the SH linewidth increased by 1.5 kHz, and the absorption contrast decreased from 35% to 15%. During a 14-day interval the absolute optical frequencies of previously unperturbed spectral holes were measured with respect to a Global-Positioning-System-monitored active H maser, using a femtosecond frequency comb. The fractional frequency drift rate exhibited an upper limit of , 65 times smaller than the most stringent previous limit.- 21 December 2018
- Published by American Physical Society (APS) in Physical Review A
- Vol. 98 (6) , 062516
Characteristics of long-lived persistent spectral holes in : at 1.2 KProperties of persistent spectral holes (SHs) relevant for frequency metrology have been investigated in the system at crystallographic site 1 and a temperature of 1.2 K. Hole linewidths as small as 0.6 kHz have been reliably achieved. The theoretically predicted dependence of the frequency shift with temperature has been confirmed with high precision. The thermal hysteresis of the SH frequency between 1.15 and 4.1 K was measured to be less than fractionally. After initially burning a large ensemble of SHs, their properties were studied on long time scales by probing different subsets at different times. SHs could still be observed 49 days after burning if not interrogated in the meantime. During this time, the SH linewidth increased by 1.5 kHz, and the absorption contrast decreased from 35% to 15%. During a 14-day interval the absolute optical frequencies of previously unperturbed spectral holes were measured with respect to a Global-Positioning-System-monitored active H maser, using a femtosecond frequency comb. The fractional frequency drift rate exhibited an upper limit of , 65 times smaller than the most stringent previous limit.- 4 June 2018
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (7) , 075011
Characterization of the long-term dimensional stability of a NEXCERA block using the optical resonator technique
NEXCERA is a machinable and highly polishable ceramic with attractive properties for use in precision instruments, in particular because its coefficient of thermal expansion exhibits a zero crossing at room temperature. We performed an accurate measurement of the long-term drift of the length of a 12 cm long NEXCERA block by using it as a spacer of a high-finesse optical cavity. At room temperature, we found a fractional length drift rate .
- 4 June 2018
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (7) , 075011
Characterization of the long-term dimensional stability of a NEXCERA block using the optical resonator technique
NEXCERA is a machinable and highly polishable ceramic with attractive properties for use in precision instruments, in particular because its coefficient of thermal expansion exhibits a zero crossing at room temperature. We performed an accurate measurement of the long-term drift of the length of a 12 cm long NEXCERA block by using it as a spacer of a high-finesse optical cavity. At room temperature, we found a fractional length drift rate .
- Open Access
Characterization of the long-term dimensional stability of a NEXCERA block using the optical resonator technique
NEXCERA is a machinable and highly polishable ceramic with attractive properties for use in precision instruments, in particular because its coefficient of thermal expansion exhibits a zero crossing at room temperature. We performed an accurate measurement of the long-term drift of the length of a 12~cm long NEXCERA block by using it as a spacer of a high-finesse optical cavity. At room temperature, we found a fractional length drift rate $L^{-1}d\Delta L/dt=-1.74\times10^{-8}~\mathrm{yr}^{-1}$.Open AccessCharacterization of the long-term dimensional stability of a NEXCERA block using the optical resonator technique
NEXCERA is a machinable and highly polishable ceramic with attractive properties for use in precision instruments, in particular because its coefficient of thermal expansion exhibits a zero crossing at room temperature. We performed an accurate measurement of the long-term drift of the length of a 12~cm long NEXCERA block by using it as a spacer of a high-finesse optical cavity. At room temperature, we found a fractional length drift rate $L^{-1}d\Delta L/dt=-1.74\times10^{-8}~\mathrm{yr}^{-1}$. - 26 March 2018
- Published by Springer Nature in Nature Physics
- Vol. 14 (6) , 555-559
Rotational spectroscopy of cold and trapped molecular ions in the Lamb–Dicke regime
- 26 March 2018
- Published by Springer Nature in Nature Physics
- Vol. 14 (6) , 555-559
Rotational spectroscopy of cold and trapped molecular ions in the Lamb–Dicke regime
- 8 May 2015
- Published by Optica Publishing Group in Optics Letters
- Vol. 40 (10) , 2289-2292
Quantum cascade laser-based mid-IR frequency metrology system with ultra-narrow linewidth and 1 × 10^−13-level frequency instability
We demonstrate a powerful tool for high-resolution mid-IR spectroscopy and frequency metrology with quantum cascade lasers (QCLs). We have implemented frequency stabilization of a QCL to an ultra-low expansion (ULE) reference cavity, via upconversion to the near-IR spectral range, at a level of . The absolute frequency of the QCL is measured relative to a hydrogen maser, with instability and inaccuracy , using a frequency comb phase stabilized to an independent ultra-stable laser. The QCL linewidth is determined to be 60 Hz, dominated by fiber noise. Active suppression of fiber noise could result in sub-10 Hz linewidth.- 8 May 2015
- Published by Optica Publishing Group in Optics Letters
- Vol. 40 (10) , 2289-2292
Quantum cascade laser-based mid-IR frequency metrology system with ultra-narrow linewidth and 1 × 10^−13-level frequency instability
We demonstrate a powerful tool for high-resolution mid-IR spectroscopy and frequency metrology with quantum cascade lasers (QCLs). We have implemented frequency stabilization of a QCL to an ultra-low expansion (ULE) reference cavity, via upconversion to the near-IR spectral range, at a level of . The absolute frequency of the QCL is measured relative to a hydrogen maser, with instability and inaccuracy , using a frequency comb phase stabilized to an independent ultra-stable laser. The QCL linewidth is determined to be 60 Hz, dominated by fiber noise. Active suppression of fiber noise could result in sub-10 Hz linewidth.- Open Access
- 31 October 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (22) , 27043-27056
Robust, frequency-stable and accurate mid-IR laser spectrometer based on frequency comb metrology of quantum cascade lasers up-converted in orientation-patterned GaAs
We demonstrate a robust and simple method for measurement, stabilization and tuning of the frequency of cw mid-infrared (MIR) lasers, in particular of quantum cascade lasers. The proof of principle is performed with a quantum cascade laser at 5.4 µm, which is upconverted to 1.2 µm by sum-frequency generation in orientation-patterned GaAs with the output of a standard high-power cw 1.5 µm fiber laser. Both the 1.2 µm and the 1.5 µm waves are measured by a standard Er:fiber frequency comb. Frequency measurement at the 100 kHz-level, stabilization to sub-10 kHz level, controlled frequency tuning and long-term stability are demonstrated.
- 31 October 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (22) , 27043-27056
Open AccessRobust, frequency-stable and accurate mid-IR laser spectrometer based on frequency comb metrology of quantum cascade lasers up-converted in orientation-patterned GaAs
We demonstrate a robust and simple method for measurement, stabilization and tuning of the frequency of cw mid-infrared (MIR) lasers, in particular of quantum cascade lasers. The proof of principle is performed with a quantum cascade laser at 5.4 µm, which is upconverted to 1.2 µm by sum-frequency generation in orientation-patterned GaAs with the output of a standard high-power cw 1.5 µm fiber laser. Both the 1.2 µm and the 1.5 µm waves are measured by a standard Er:fiber frequency comb. Frequency measurement at the 100 kHz-level, stabilization to sub-10 kHz level, controlled frequency tuning and long-term stability are demonstrated.
- 3 May 2012
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 108 (18) , 183003
Manipulation of Individual Hyperfine States in Cold Trapped Molecular Ions and Application toFrequency MetrologyAdvanced techniques for manipulation of internal states, standard in atomic physics, are demonstrated for a charged molecular species for the first time. We address individual hyperfine states of rovibrational levels of a diatomic ion by optical excitation of individual hyperfine transitions, and achieve controlled transfer of population into a selected hyperfine state. We use molecular hydrogen ions () as a model system and employ a novel frequency-comb-based, continuous-wave laser spectrometer. The achieved spectral resolution is the highest obtained so far in the optical domain on a molecular ion species. As a consequence, we are also able to perform the most precise test yet of the ab initio theory of a molecule.- 3 May 2012
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 108 (18) , 183003
Manipulation of Individual Hyperfine States in Cold Trapped Molecular Ions and Application toFrequency MetrologyAdvanced techniques for manipulation of internal states, standard in atomic physics, are demonstrated for a charged molecular species for the first time. We address individual hyperfine states of rovibrational levels of a diatomic ion by optical excitation of individual hyperfine transitions, and achieve controlled transfer of population into a selected hyperfine state. We use molecular hydrogen ions () as a model system and employ a novel frequency-comb-based, continuous-wave laser spectrometer. The achieved spectral resolution is the highest obtained so far in the optical domain on a molecular ion species. As a consequence, we are also able to perform the most precise test yet of the ab initio theory of a molecule.- 29 March 2012
- Published by American Physical Society (APS) in Physical Review A
- Vol. 85 (3) , 032519
Observation of a rotational transition of trapped and sympathetically cooled molecular ions
We demonstrate rotational excitation of molecular ions that are sympathetically cooled by laser-cooled atomic ions to a temperature as low as approximately 10 mK. The molecular hydrogen ions HD and the fundamental rotational transition at 1.3 THz, the most fundamental dipole-allowed rotational transition of any molecule, are used as a test case. This transition has not been observed before. Rotational laser cooling was employed in order to increase the signal, and resonance-enhanced multiphoton dissociation was used as detection method. The black-body-radiation-induced rotational excitation is also observed. The extension of the method to other molecular species is briefly discussed.- 29 March 2012
- Published by American Physical Society (APS) in Physical Review A
- Vol. 85 (3) , 032519
Observation of a rotational transition of trapped and sympathetically cooled molecular ions
We demonstrate rotational excitation of molecular ions that are sympathetically cooled by laser-cooled atomic ions to a temperature as low as approximately 10 mK. The molecular hydrogen ions HD and the fundamental rotational transition at 1.3 THz, the most fundamental dipole-allowed rotational transition of any molecule, are used as a test case. This transition has not been observed before. Rotational laser cooling was employed in order to increase the signal, and resonance-enhanced multiphoton dissociation was used as detection method. The black-body-radiation-induced rotational excitation is also observed. The extension of the method to other molecular species is briefly discussed.