Riaz Ahmad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Riaz Ahmad has a total of 109 co-authors. Here are the top co-authors by number of shared publications:
- Tousif Hussain
Centre for Advanced Studies in Physics (CASP), Government College University, Lahore, Pakistan
6 shared publications - Mohsin Rafique
Centre for Advanced Studies in Physics, Government College University, Lahore, Pakistan
5 shared publications - Naveed Afzal
Centre for Advanced Studies in Physics, GC University, Lahore, Pakistan
5 shared publications Uzma Ikhlaq
Department of Physics, Government College University Lahore, Lahore, Pakistan
3 shared publications- Ameeq Farooq
Corrosion Control Research Cell, Institute of Metallurgy and Materials Engineering, Faculty of Chemical and Materials Engineering, University of the Punjab, Lahore, 54590, Pakistan
2 shared publications - Fozia Shaheen
Department of Physics, Government College University Lahore, Punjab, Pakistan
2 shared publications
Latest Publications
- 21 March 2026
- Published by Springer Nature in Journal of Materials Science
- Vol. 61 (18) , 12572-12588
Multifunctional 3D FeMoO4/rGO/PANI nanocomposites: a dual-platform for uric acid detection and advanced supercapacitor performance
- 21 March 2026
- Published by Springer Nature in Journal of Materials Science
- Vol. 61 (18) , 12572-12588
Multifunctional 3D FeMoO4/rGO/PANI nanocomposites: a dual-platform for uric acid detection and advanced supercapacitor performance
- 16 October 2023
- Published by IOP Publishing in Physica Scripta
- Vol. 98 (11) , 115023
Excellent photocatalytic and antibacterial performance of silver and cobalt doped MnO nanoparticles
Metals (Ag, Fe, Co and Ag+Co)-doped MnO nanoparticles are synthesized by sol–gel method and are investigated for photocatalytic and antibacterial activities. The synthesized nanoparticles are characterized by x-ray diffraction (XRD) and scanning electron microscopic (SEM) techniques to determine the structural and morphological properties. The XRD results indicate the successful incorporation of the doped-metal elements into the lattice and changes in the crystallite sizes. The SEM micrographs indicate nano-porous and agglomerated grains after the doping and maximum nano-porosity is estimated for Co and Ag+Co doped nanoparticles. Methylene-blue (MB) dye is used to measure the photocatalytic activity which indicates the degradation of 94% for Ag+Co doped nanoparticles in only 30 min. The antibacterial activities of the nanoparticles are investigated against pathogenic bacteria by using the cultures of Bacillus, Escherichia Coli , Streptococcus and Cocci. The dose quantities are varied and compared with the standard Amikacin medicine that is commercially used for antifungal treatment. It is found that inhibition zones increase up to five times than the standard against Bacillus, Escherichia Coli and Cocci and doubles for Streptococcus at the dose level higher than 20 μ l. These results indicate that Ag+Co doped MnO nanoparticles show the excellent photocatalytic performance and the best antibacterial results against the Bacillus bacteria.
- 16 October 2023
- Published by IOP Publishing in Physica Scripta
- Vol. 98 (11) , 115023
Excellent photocatalytic and antibacterial performance of silver and cobalt doped MnO nanoparticles
Metals (Ag, Fe, Co and Ag+Co)-doped MnO nanoparticles are synthesized by sol–gel method and are investigated for photocatalytic and antibacterial activities. The synthesized nanoparticles are characterized by x-ray diffraction (XRD) and scanning electron microscopic (SEM) techniques to determine the structural and morphological properties. The XRD results indicate the successful incorporation of the doped-metal elements into the lattice and changes in the crystallite sizes. The SEM micrographs indicate nano-porous and agglomerated grains after the doping and maximum nano-porosity is estimated for Co and Ag+Co doped nanoparticles. Methylene-blue (MB) dye is used to measure the photocatalytic activity which indicates the degradation of 94% for Ag+Co doped nanoparticles in only 30 min. The antibacterial activities of the nanoparticles are investigated against pathogenic bacteria by using the cultures of Bacillus, Escherichia Coli , Streptococcus and Cocci. The dose quantities are varied and compared with the standard Amikacin medicine that is commercially used for antifungal treatment. It is found that inhibition zones increase up to five times than the standard against Bacillus, Escherichia Coli and Cocci and doubles for Streptococcus at the dose level higher than 20 μ l. These results indicate that Ag+Co doped MnO nanoparticles show the excellent photocatalytic performance and the best antibacterial results against the Bacillus bacteria.
- 27 July 2022
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 177 (9-10) , 892-902
Deposition of molybdenum carbide thin films by dense plasma focus device
This work was motivated by the promising physiochemical properties and catalytic activity of molybdenum carbide. Thin films of molybdenum carbide were deposited on the mono-crystalline cubic Si (400) substrate by utilizing a 3.6 kJ dense plasma focus device (Mather-type) with multiple shots. The structure of the films was examined by X-ray diffraction (XRD). XRD results indicated the absence of crystalline film for 5 focus shots, while for increased numbers of focus shots, the emergence of Mo-C peaks in the orientations (120), (014) and (232) confirmed the formation of orthorhombic β-Mo2C polycrystalline films. Moreover, a small variation in the crystallite size was observed by increasing the number of focus shots. The presence of molybdenum and carbon was confirmed by energy-dispersive X-ray (EDX) analysis. Surface morphology was studied under scanning electron microscope (SEM). SEM micrographs revealed non-uniform films with some surface defects such as cracks and craters of micron size, and rough surface. Revealed by the ellipsometry technique, the film thickness increased by increasing the number of focus shots. The electric conductivity, measured by the four-point probe technique, was the highest for 10 focus shots. However, the films have some structural defects, low conductivity and impurities like silicon and silicon carbide, but it was the first ever successful attempt to deposit molybdenum-carbide (Mo2C) thin films using the dense plasma focus device.
- 27 July 2022
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 177 (9-10) , 892-902
Deposition of molybdenum carbide thin films by dense plasma focus device
This work was motivated by the promising physiochemical properties and catalytic activity of molybdenum carbide. Thin films of molybdenum carbide were deposited on the mono-crystalline cubic Si (400) substrate by utilizing a 3.6 kJ dense plasma focus device (Mather-type) with multiple shots. The structure of the films was examined by X-ray diffraction (XRD). XRD results indicated the absence of crystalline film for 5 focus shots, while for increased numbers of focus shots, the emergence of Mo-C peaks in the orientations (120), (014) and (232) confirmed the formation of orthorhombic β-Mo2C polycrystalline films. Moreover, a small variation in the crystallite size was observed by increasing the number of focus shots. The presence of molybdenum and carbon was confirmed by energy-dispersive X-ray (EDX) analysis. Surface morphology was studied under scanning electron microscope (SEM). SEM micrographs revealed non-uniform films with some surface defects such as cracks and craters of micron size, and rough surface. Revealed by the ellipsometry technique, the film thickness increased by increasing the number of focus shots. The electric conductivity, measured by the four-point probe technique, was the highest for 10 focus shots. However, the films have some structural defects, low conductivity and impurities like silicon and silicon carbide, but it was the first ever successful attempt to deposit molybdenum-carbide (Mo2C) thin films using the dense plasma focus device.
- Open Access
- 1 November 2021
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 15, 623-632
Hierarchical porous spinel nickel cobaltite nanoflakes anchored reduced graphene oxide nano-photocatalyst for efficient degradation of organic pollutants under natural sunlight
- 1 November 2021
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 15, 623-632
Open AccessHierarchical porous spinel nickel cobaltite nanoflakes anchored reduced graphene oxide nano-photocatalyst for efficient degradation of organic pollutants under natural sunlight
- 22 September 2021
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 136 (9) , 1-15
Study the effect of silver ion implantation on the structural, optical, and electrical properties of copper oxide thin films: an experimental and theoretical approach
- 22 September 2021
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 136 (9) , 1-15
Study the effect of silver ion implantation on the structural, optical, and electrical properties of copper oxide thin films: an experimental and theoretical approach
- Open Access
- 1 December 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (12) , 126428
Modification in ZnO film properties by 250 keV cobalt implantation
Direct current magnetron sputtering technique was used to synthesize ZnO films on PET (Polyethylene terephthalate) substrate. The as-synthesized films were exposed to 250 keV cobalt (Co) ions by Pelletron Accelerator at different ion fluences (in range of 1011 to 1014 ions/cm2). The lattice constant, crystallite structure, size and strain of pristine and Co-implanted films were studied through x-ray diffraction (XRD) method. The study showed that the ZnO film became partially amorphous after Co implantation up to the fluence of 1013 ions/cm2. However, Co implantation at 1014 ions/cm2 slightly restored the film's crystallinity due to ion-induced localized heating. Tauc equation was used to estimate the band gap of pristine and Co implanted films. The band gap of Co implanted ZnO was decreased by increasing the ion fluence that was ascribed to a decrease in the conduction band tail due to overlapping of donor defect levels. Electrical measurements showed that the ZnO film became more conductive with increasing the Co fluence.
- 1 December 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (12) , 126428
Open AccessModification in ZnO film properties by 250 keV cobalt implantation
Direct current magnetron sputtering technique was used to synthesize ZnO films on PET (Polyethylene terephthalate) substrate. The as-synthesized films were exposed to 250 keV cobalt (Co) ions by Pelletron Accelerator at different ion fluences (in range of 1011 to 1014 ions/cm2). The lattice constant, crystallite structure, size and strain of pristine and Co-implanted films were studied through x-ray diffraction (XRD) method. The study showed that the ZnO film became partially amorphous after Co implantation up to the fluence of 1013 ions/cm2. However, Co implantation at 1014 ions/cm2 slightly restored the film's crystallinity due to ion-induced localized heating. Tauc equation was used to estimate the band gap of pristine and Co implanted films. The band gap of Co implanted ZnO was decreased by increasing the ion fluence that was ascribed to a decrease in the conduction band tail due to overlapping of donor defect levels. Electrical measurements showed that the ZnO film became more conductive with increasing the Co fluence.
- Open Access
- 1 December 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (12) , 126452
Improvement in electrochemical corrosion resistance of Mg–Al–Zn alloy by 250 keV carbon ions irradiation
- 1 December 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (12) , 126452
Open AccessImprovement in electrochemical corrosion resistance of Mg–Al–Zn alloy by 250 keV carbon ions irradiation
- 1 September 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (11) , 116418
Influence of plasma excitation power on mechanical property and biocompatibility of titania/alumina composite thin films for medical implant prepared by magnetron sputtering
In present study, titania-alumina composite films were deposited using pulsed DC magnetron sputtering system for various plasma excitation powers (100 W to 200 W). The composition of films was examined through X-ray diffractometer (XRD), whereas Scanning electron microscope (SEM) and Atomic force microscope (AFM) were carried out to investigate the surface morphology. The mechanical properties such as strength and hardness of deposited films were determined by using Universal testing machine and Vickers hardness tester. It was observed that the yield strength (YS), ultimate tensile strength (UTS) and hardness of treated samples were increased. The biocompatibility of deposited films was studied by culturing the MC3T3-E1 cells for three days. The micrographs of cells culture showed better cells growth/proliferation (elongated morphology) on film prepared at 150 W. Our results exhibit that titania-alumina composite films enhance the surface roughness, mechanical properties and biocompatibility of titanium. Therefore, Ti is also a better choice for load barring applications as compared to Ti6Al4V which contain the toxic element.In present study, titania-alumina composite films were deposited using pulsed DC magnetron sputtering system for various plasma excitation powers (100 W to 200 W). The composition of films was examined through X-ray diffractometer (XRD), whereas Scanning electron microscope (SEM) and Atomic force microscope (AFM) were carried out to investigate the surface morphology. The mechanical properties such as strength and hardness of deposited films were determined by using Universal testing machine and Vickers hardness tester. It was observed that the yield strength (YS), ultimate tensile strength (UTS) and hardness of treated samples were increased. The stability of deposited films was investigated using scratch test. The biocompatibility of deposited films was studied by culturing the MC3T3-E1 cells for three days. The micrographs of cells culture showed better cells growth/proliferation (elongated morphology) on film prepared at 150 W. Our results exhibit that titania-alumina composite films enhance the surface roughness, mechanical properties and biocompatibility of titanium. Therefore, Ti is also a better choice for load barring applications as compared to Ti6Al4V which contain the toxic element.
- 1 September 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (11) , 116418
Influence of plasma excitation power on mechanical property and biocompatibility of titania/alumina composite thin films for medical implant prepared by magnetron sputtering
In present study, titania-alumina composite films were deposited using pulsed DC magnetron sputtering system for various plasma excitation powers (100 W to 200 W). The composition of films was examined through X-ray diffractometer (XRD), whereas Scanning electron microscope (SEM) and Atomic force microscope (AFM) were carried out to investigate the surface morphology. The mechanical properties such as strength and hardness of deposited films were determined by using Universal testing machine and Vickers hardness tester. It was observed that the yield strength (YS), ultimate tensile strength (UTS) and hardness of treated samples were increased. The biocompatibility of deposited films was studied by culturing the MC3T3-E1 cells for three days. The micrographs of cells culture showed better cells growth/proliferation (elongated morphology) on film prepared at 150 W. Our results exhibit that titania-alumina composite films enhance the surface roughness, mechanical properties and biocompatibility of titanium. Therefore, Ti is also a better choice for load barring applications as compared to Ti6Al4V which contain the toxic element.In present study, titania-alumina composite films were deposited using pulsed DC magnetron sputtering system for various plasma excitation powers (100 W to 200 W). The composition of films was examined through X-ray diffractometer (XRD), whereas Scanning electron microscope (SEM) and Atomic force microscope (AFM) were carried out to investigate the surface morphology. The mechanical properties such as strength and hardness of deposited films were determined by using Universal testing machine and Vickers hardness tester. It was observed that the yield strength (YS), ultimate tensile strength (UTS) and hardness of treated samples were increased. The stability of deposited films was investigated using scratch test. The biocompatibility of deposited films was studied by culturing the MC3T3-E1 cells for three days. The micrographs of cells culture showed better cells growth/proliferation (elongated morphology) on film prepared at 150 W. Our results exhibit that titania-alumina composite films enhance the surface roughness, mechanical properties and biocompatibility of titanium. Therefore, Ti is also a better choice for load barring applications as compared to Ti6Al4V which contain the toxic element.
- 9 October 2018
- Published by IOP Publishing in Physica Scripta
- Vol. 93 (11) , 115303
Impact of variable energy hydrogen ions on structural and mechanical properties of Zircaloy-4
This paper demonstrates hydrogen ion (H + ) induced structural and mechanical changes in Zircaloy-4 correlated with its surface morphology. The specimens of Zircaloy-4 were irradiated with H + at room temperature using a pelletron accelerator. The ion energy was varied from 1 to 4 MeV in four equal steps while keeping the dose fixed at 1 × 10 14 H + cm −2 . The range of H + inside Zircaloy-4, investigated through SRIM software, was 10.4 μ m, 29.1 μ m, 54.1 μ m and 85 μ m for 1 MeV, 2 MeV, 3 MeV and 4 MeV irradiated specimens, respectively. X-ray diffraction patterns of irradiated Zircaloy-4 exhibited variations in the width and position of Zr diffraction peaks. The Williamson–Hall analysis of these peaks depicted inconsistent changes in crystallite size and strain with increase of H + energy. The surface morphology revealed the formation of bubbles and cavities in specimens irradiated with 1 MeV ions. With increasing ion energy above 1 MeV, small cavities and particles clusters were observed. The mechanical testing results indicated an increase in the micro-hardness of the sample irradiated with 1 MeV H + , however, the micro-hardness decreased with increase of ion energy greater than 1 MeV. The obtained results were elucidated on the basis of variable energy H + interaction with Zircaloy-4 and annihilation of ions induced defects at higher energies.
- 9 October 2018
- Published by IOP Publishing in Physica Scripta
- Vol. 93 (11) , 115303
Impact of variable energy hydrogen ions on structural and mechanical properties of Zircaloy-4
This paper demonstrates hydrogen ion (H + ) induced structural and mechanical changes in Zircaloy-4 correlated with its surface morphology. The specimens of Zircaloy-4 were irradiated with H + at room temperature using a pelletron accelerator. The ion energy was varied from 1 to 4 MeV in four equal steps while keeping the dose fixed at 1 × 10 14 H + cm −2 . The range of H + inside Zircaloy-4, investigated through SRIM software, was 10.4 μ m, 29.1 μ m, 54.1 μ m and 85 μ m for 1 MeV, 2 MeV, 3 MeV and 4 MeV irradiated specimens, respectively. X-ray diffraction patterns of irradiated Zircaloy-4 exhibited variations in the width and position of Zr diffraction peaks. The Williamson–Hall analysis of these peaks depicted inconsistent changes in crystallite size and strain with increase of H + energy. The surface morphology revealed the formation of bubbles and cavities in specimens irradiated with 1 MeV ions. With increasing ion energy above 1 MeV, small cavities and particles clusters were observed. The mechanical testing results indicated an increase in the micro-hardness of the sample irradiated with 1 MeV H + , however, the micro-hardness decreased with increase of ion energy greater than 1 MeV. The obtained results were elucidated on the basis of variable energy H + interaction with Zircaloy-4 and annihilation of ions induced defects at higher energies.
- 22 August 2018
- Published by IOP Publishing in Materials Research Express
- Vol. 5 (10) , 106501
Effects of carbon ions irradiation on the electrochemical response of AISI 304 stainless steel
- 22 August 2018
- Published by IOP Publishing in Materials Research Express
- Vol. 5 (10) , 106501
Effects of carbon ions irradiation on the electrochemical response of AISI 304 stainless steel