Kang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kang Wang has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Claude B. Sirlin
Liver Imaging Group, Department of Radiology, University of California San Diego, La Jolla, CA, USA
4 shared publications - Aiguo Han
Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA
2 shared publications - Albert Hsiao
Department of Radiology, University of California San Diego, La Jolla, Calif
2 shared publications - Cheng William Hong
Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA
2 shared publications - Jake T. Weeks
Liver Imaging Group, University of California San Diego, San Diego, CA, USA
2 shared publications - Kathleen Marsh
Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA
2 shared publications
Latest Publications
- 1 July 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Artificial Intelligence
- Vol. 8 (4) , e260501
When One Sequence Is Enough—And When It Isn’t
- 1 July 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Artificial Intelligence
- Vol. 8 (4) , e260501
When One Sequence Is Enough—And When It Isn’t
- 17 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Conception de la mémoire magnétique par couple de transfert de spin et sa recherche de fiabilité
Conception de la mémoire magnétique par couple de transfert de spin et sa recherche de fiabilité: Cette thèse vise principalement à faire face à la fiabilité de stockage de STT-MRAM au niveau dispositif, au niveau circuit et au niveau système. Les majeures contributions de cette thèse peuvent être résumées comme il suit: a) La modélisation de la jonction tunnel magnétique par courant polarisé en spin (STT-MTJ), pour développer un compact modèle SPICE de STT-MTJ. b) Le design de fiabilité de STT-MRAM au niveau dispositif, pour étudier les structures de base de cellule de mémoire et de cellules de référence. Dans cette partie, nous avons proposé une cellule de mémoire configurable (CMC), une cellule dynamique de référence (RDC) et un loquet magnétique de rayonnement durci (RHM-Latch). c) Le design de fiabilité de STT-MRAM au niveau circuit, pour étudier les modules de circuits périphériques. Dans cette partie, nous avons proposé un circuit de lecture séparé et précharge (SPCRC), un circuit de lecture offset-Tolérant sans perturbation (OTDFRC) et un circuit de correction d'erreur intégré. d) Le design de fiabilité de STT-MRAM au niveau système, vise principalement à étudier l'architecture de la puce. Dans cette partie, nous avons proposé une architecture reconfigurable (nommé Re-STT-MRAM) et une architecture de correction d'erreur hybride (nommé cRR-SECC).
- 17 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Conception de la mémoire magnétique par couple de transfert de spin et sa recherche de fiabilité
Conception de la mémoire magnétique par couple de transfert de spin et sa recherche de fiabilité: Cette thèse vise principalement à faire face à la fiabilité de stockage de STT-MRAM au niveau dispositif, au niveau circuit et au niveau système. Les majeures contributions de cette thèse peuvent être résumées comme il suit: a) La modélisation de la jonction tunnel magnétique par courant polarisé en spin (STT-MTJ), pour développer un compact modèle SPICE de STT-MTJ. b) Le design de fiabilité de STT-MRAM au niveau dispositif, pour étudier les structures de base de cellule de mémoire et de cellules de référence. Dans cette partie, nous avons proposé une cellule de mémoire configurable (CMC), une cellule dynamique de référence (RDC) et un loquet magnétique de rayonnement durci (RHM-Latch). c) Le design de fiabilité de STT-MRAM au niveau circuit, pour étudier les modules de circuits périphériques. Dans cette partie, nous avons proposé un circuit de lecture séparé et précharge (SPCRC), un circuit de lecture offset-Tolérant sans perturbation (OTDFRC) et un circuit de correction d'erreur intégré. d) Le design de fiabilité de STT-MRAM au niveau système, vise principalement à étudier l'architecture de la puce. Dans cette partie, nous avons proposé une architecture reconfigurable (nommé Re-STT-MRAM) et une architecture de correction d'erreur hybride (nommé cRR-SECC).
- Open Access
- 1 January 2026
- Published by XMLink in Korean Journal of Radiology
- Vol. 27 (6) , 591-594
Response to “Considerations in Imaging-Based Assessment of Steatotic Liver Disease to Enhance Harmonization, Longitudinal Interpretation, and Clinical Implementation”
Chan SM, et al. Korean J Radiol. 2026 ;27:e41. https://doi.org/10.3348/kjr.2026.0358
- 1 January 2026
- Published by XMLink in Korean Journal of Radiology
- Vol. 27 (6) , 591-594
Open AccessResponse to “Considerations in Imaging-Based Assessment of Steatotic Liver Disease to Enhance Harmonization, Longitudinal Interpretation, and Clinical Implementation”
Chan SM, et al. Korean J Radiol. 2026 ;27:e41. https://doi.org/10.3348/kjr.2026.0358
- Open Access
- 1 January 2026
- Published by XMLink in Korean Journal of Radiology
- Vol. 27 (2) , 137-151
Imaging Evaluation for Steatotic Liver Disease
Chan SM, et al. Korean J Radiol. 2026 Jan;27:e2. https://doi.org/10.3348/kjr.2025.0966
- 1 January 2026
- Published by XMLink in Korean Journal of Radiology
- Vol. 27 (2) , 137-151
Open AccessImaging Evaluation for Steatotic Liver Disease
Chan SM, et al. Korean J Radiol. 2026 Jan;27:e2. https://doi.org/10.3348/kjr.2025.0966
- 5 June 2024
- Published by Elsevier in Medical Image Analysis
- Vol. 97, 103226
Universal and extensible language-vision models for organ segmentation and tumor detection from abdominal computed tomography
- 5 June 2024
- Published by Elsevier in Medical Image Analysis
- Vol. 97, 103226
Universal and extensible language-vision models for organ segmentation and tumor detection from abdominal computed tomography
- 29 May 2019
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 32 (5) , 855-864
Image Annotation by Eye Tracking: Accuracy and Precision of Centerlines of Obstructed Small-Bowel Segments Placed Using Eye Trackers
Small-bowel obstruction (SBO) is a common and important disease, for which machine learning tools have yet to be developed. Image annotation is a critical first step for development of such tools. This study assesses whether image annotation by eye tracking is sufficiently accurate and precise to serve as a first step in the development of machine learning tools for detection of SBO on CT. Seven subjects diagnosed with SBO by CT were included in the study. For each subject, an obstructed segment of bowel was chosen. Three observers annotated the centerline of the segment by manual fiducial placement and by visual fiducial placement using a Tobii 4c eye tracker. Each annotation was repeated three times. The distance between centerlines was calculated after alignment using dynamic time warping (DTW) and statistically compared to clinical thresholds for diagnosis of SBO. Intra-observer DTW distance between manual and visual centerlines was calculated as a measure of accuracy. These distances were 1.1 ± 0.2, 1.3 ± 0.4, and 1.8 ± 0.2 cm for the three observers and were less than 1.5 cm for two of three observers (P < 0.01). Intra- and inter-observer DTW distances between centerlines placed with each method were calculated as measures of precision. These distances were 0.6 ± 0.1 and 0.8 ± 0.2 cm for manual centerlines, 1.1 ± 0.4 and 1.9 ± 0.6 cm for visual centerlines, and were less than 3.0 cm in all cases (P < 0.01). Results suggest that eye tracking–based annotation is sufficiently accurate and precise for small-bowel centerline annotation for use in machine learning–based applications.
- 29 May 2019
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 32 (5) , 855-864
Image Annotation by Eye Tracking: Accuracy and Precision of Centerlines of Obstructed Small-Bowel Segments Placed Using Eye Trackers
Small-bowel obstruction (SBO) is a common and important disease, for which machine learning tools have yet to be developed. Image annotation is a critical first step for development of such tools. This study assesses whether image annotation by eye tracking is sufficiently accurate and precise to serve as a first step in the development of machine learning tools for detection of SBO on CT. Seven subjects diagnosed with SBO by CT were included in the study. For each subject, an obstructed segment of bowel was chosen. Three observers annotated the centerline of the segment by manual fiducial placement and by visual fiducial placement using a Tobii 4c eye tracker. Each annotation was repeated three times. The distance between centerlines was calculated after alignment using dynamic time warping (DTW) and statistically compared to clinical thresholds for diagnosis of SBO. Intra-observer DTW distance between manual and visual centerlines was calculated as a measure of accuracy. These distances were 1.1 ± 0.2, 1.3 ± 0.4, and 1.8 ± 0.2 cm for the three observers and were less than 1.5 cm for two of three observers (P < 0.01). Intra- and inter-observer DTW distances between centerlines placed with each method were calculated as measures of precision. These distances were 0.6 ± 0.1 and 0.8 ± 0.2 cm for manual centerlines, 1.1 ± 0.4 and 1.9 ± 0.6 cm for visual centerlines, and were less than 3.0 cm in all cases (P < 0.01). Results suggest that eye tracking–based annotation is sufficiently accurate and precise for small-bowel centerline annotation for use in machine learning–based applications.
- 1 March 2019
- Published by Radiological Society of North America (RSNA) in Radiology: Artificial Intelligence
- Vol. 1 (2)
Automated CT and MRI Liver Segmentation and Biometry Using a Generalized Convolutional Neural Network
Automated liver segmentation from CT and MRI data is feasible with a convolutional neural network, requiring relatively few image datasets for generalization to multiple imaging modalities and tech... Purpose To assess feasibility of training a convolutional neural network (CNN) to automate liver segmentation across different imaging modalities and techniques used in clinical practice and to app...
- 1 March 2019
- Published by Radiological Society of North America (RSNA) in Radiology: Artificial Intelligence
- Vol. 1 (2)
Automated CT and MRI Liver Segmentation and Biometry Using a Generalized Convolutional Neural Network
Automated liver segmentation from CT and MRI data is feasible with a convolutional neural network, requiring relatively few image datasets for generalization to multiple imaging modalities and tech... Purpose To assess feasibility of training a convolutional neural network (CNN) to automate liver segmentation across different imaging modalities and techniques used in clinical practice and to app...
- 13 June 2017
- Published by Springer Nature in Abdominal Radiology
- Vol. 42 (12) , 2843-2854
Repeatability and reproducibility of 2D and 3D hepatic MR elastography with rigid and flexible drivers at end-expiration and end-inspiration in healthy volunteers
Purpose To evaluate the repeatability and reproducibility of 2D and 3D hepatic MRE with rigid and flexible drivers at end-expiration and end-inspiration in healthy volunteers. Materials and methods Nine healthy volunteers underwent two same-day MRE exams separated by a 5- to 10-min break. In each exam, 2D and 3D MRE scans were performed, each under four conditions (2 driver types [rigid, flexible] × 2 breath-hold phases [end-expiration, end-inspiration]). Repeatability (measurements under identical conditions) and reproducibility (measurements under different conditions) were analyzed by calculating bias, limit of agreement, repeatability coefficient (RC), reproducibility coefficient (RDC), intraclass correlation coefficient (ICC), and concordance correlation coefficient (CCC), as appropriate. Results For 2D MRE, RCs and ICCs range between 0.29–0.49 and 0.71–0.91, respectively. For 3D MRE, RCs and ICCs range between 0.16–0.26 and 0.84–0.96, respectively. Stiffness values were biased by breath-hold phase, being higher at end-inspiration than end-expiration, and the differences were significant for 3D MRE (p < 0.01). No bias was found between driver types. Inspiration vs. expiration RDCs and CCCs ranged between 0.30–0.54 and 0.61–0.72, respectively. Rigid vs. flexible driver RDCs and CCCs ranged between 0.10–0.44 and 0.79–0.94, respectively. Conclusion This preliminary study suggests that 2D MRE and 3D MRE under most conditions potentially have good repeatability. Our result also points to the possibility that stiffness measured with the rigid and flexible drivers is reproducible. Reproducibility between breath-hold phases was modest, suggesting breath-hold phase might be a confounding factor in MRE-based stiffness measurement. However, larger studies are required to validate these preliminary results.
- 13 June 2017
- Published by Springer Nature in Abdominal Radiology
- Vol. 42 (12) , 2843-2854
Repeatability and reproducibility of 2D and 3D hepatic MR elastography with rigid and flexible drivers at end-expiration and end-inspiration in healthy volunteers
Purpose To evaluate the repeatability and reproducibility of 2D and 3D hepatic MRE with rigid and flexible drivers at end-expiration and end-inspiration in healthy volunteers. Materials and methods Nine healthy volunteers underwent two same-day MRE exams separated by a 5- to 10-min break. In each exam, 2D and 3D MRE scans were performed, each under four conditions (2 driver types [rigid, flexible] × 2 breath-hold phases [end-expiration, end-inspiration]). Repeatability (measurements under identical conditions) and reproducibility (measurements under different conditions) were analyzed by calculating bias, limit of agreement, repeatability coefficient (RC), reproducibility coefficient (RDC), intraclass correlation coefficient (ICC), and concordance correlation coefficient (CCC), as appropriate. Results For 2D MRE, RCs and ICCs range between 0.29–0.49 and 0.71–0.91, respectively. For 3D MRE, RCs and ICCs range between 0.16–0.26 and 0.84–0.96, respectively. Stiffness values were biased by breath-hold phase, being higher at end-inspiration than end-expiration, and the differences were significant for 3D MRE (p < 0.01). No bias was found between driver types. Inspiration vs. expiration RDCs and CCCs ranged between 0.30–0.54 and 0.61–0.72, respectively. Rigid vs. flexible driver RDCs and CCCs ranged between 0.10–0.44 and 0.79–0.94, respectively. Conclusion This preliminary study suggests that 2D MRE and 3D MRE under most conditions potentially have good repeatability. Our result also points to the possibility that stiffness measured with the rigid and flexible drivers is reproducible. Reproducibility between breath-hold phases was modest, suggesting breath-hold phase might be a confounding factor in MRE-based stiffness measurement. However, larger studies are required to validate these preliminary results.