Faezeh Marzbanrad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Faezeh Marzbanrad has a total of 135 co-authors. Here are the top co-authors by number of shared publications:
- Chiranjibi Sitaula
Earth Observation and AI Research Group, Department of Infrastructure Engineering, The University of Melbourne, Carlton, Australia
11 shared publications - Gari D. Clifford
Emory University
7 shared publications - Atul Malhotra
Monash Newborn, Monash Children’s Hospital, Melbourne, Australia
6 shared publications - Ethan Grooby
Department of Electrical and Computer Systems Engineering, Monash University, Melbourne, Clayton, VIC, Australia
6 shared publications - Ahsan Habib Khandoker
Department of Biomedical Engineering and Biotechnology Khalifa University Abu Dhabi United Arab Emirates
5 shared publications Arrabella King
Monash Newborn, Monash Childrens Hospital and Department of Paediatrics, Monash University, Melbourne, Clayton, VIC, Australia
4 shared publications
Latest Publications
- Open Access
- 18 September 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 29088
Congenital heart disease classification using phonocardiograms: a scalable screening tool for diverse environments
- 18 September 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 29088
Open AccessCongenital heart disease classification using phonocardiograms: a scalable screening tool for diverse environments
- 31 March 2026
- Published by SAGE Publications in The International Journal of Robotics Research
Can familiarization with a supernumerary robotic finger restore task-dependent cortico-autonomic coupling in first-time healthy users?
Supernumerary Robotic Fingers (SRFs) have proven their capabilities in enhancing manipulation and dexterity in precision tasks enabling multitasking in healthy individuals, while also playing a compensatory role for those with motor impairments. However, the literature on SRF adaptation and embodiment remains scarce, particularly in terms of the neurophysiological basis underlying their introduction, use, and assimilation. This study employed a controlled-time-delay-stability (CTDS) framework to investigate physiological embodiment by capturing multimodal signals (encephalography (EEG), electrodermal-activity (EDA), photoplethysmography (PPG), and respiratory) in 30 adults performing three activities-of-daily-living. Tasks were completed across three phases: without SRF, with SRF immediately after attachment, and with SRF following individualized training. CTDS quantified pairwise strength and directionality of dynamic interactions while controlling for indirect effects. Network visualization provided a holistic view of brain–body reconfiguration with SRF use. Resting baselines showed no significant differences across phases, suggesting SRF attachment alone did not introduce sufficient stress to alter brain–body interactions. During tasks, brain–body interactions exhibited task-dependent modulation. This modulation was suppressed with initial SRF attachment but reappeared after training/familiarization, with post-training patterns becoming statistically indistinguishable from those without the SRF. These results indicate that SRFs can be effectively embodied into the body schema after targeted training. The transient plasticity observed in first-time users may serve as a biomarker for customizing SRF training and tracking neurorehabilitation progress. Extending prior findings of rapid cortical adaptation, this study shows that brain–body networks reconfigure in a task-specific manner toward assimilation following brief familiarization. Future work warrants clinical validation and translation.
- 31 March 2026
- Published by SAGE Publications in The International Journal of Robotics Research
Can familiarization with a supernumerary robotic finger restore task-dependent cortico-autonomic coupling in first-time healthy users?
Supernumerary Robotic Fingers (SRFs) have proven their capabilities in enhancing manipulation and dexterity in precision tasks enabling multitasking in healthy individuals, while also playing a compensatory role for those with motor impairments. However, the literature on SRF adaptation and embodiment remains scarce, particularly in terms of the neurophysiological basis underlying their introduction, use, and assimilation. This study employed a controlled-time-delay-stability (CTDS) framework to investigate physiological embodiment by capturing multimodal signals (encephalography (EEG), electrodermal-activity (EDA), photoplethysmography (PPG), and respiratory) in 30 adults performing three activities-of-daily-living. Tasks were completed across three phases: without SRF, with SRF immediately after attachment, and with SRF following individualized training. CTDS quantified pairwise strength and directionality of dynamic interactions while controlling for indirect effects. Network visualization provided a holistic view of brain–body reconfiguration with SRF use. Resting baselines showed no significant differences across phases, suggesting SRF attachment alone did not introduce sufficient stress to alter brain–body interactions. During tasks, brain–body interactions exhibited task-dependent modulation. This modulation was suppressed with initial SRF attachment but reappeared after training/familiarization, with post-training patterns becoming statistically indistinguishable from those without the SRF. These results indicate that SRFs can be effectively embodied into the body schema after targeted training. The transient plasticity observed in first-time users may serve as a biomarker for customizing SRF training and tracking neurorehabilitation progress. Extending prior findings of rapid cortical adaptation, this study shows that brain–body networks reconfigure in a task-specific manner toward assimilation following brief familiarization. Future work warrants clinical validation and translation.
- 24 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. PP (21682194) , 1-14
Towards Objective Obstetric Ultrasound Assessment: Contrastive Representation Learning for Fetal Movement Detection
Accurate fetal movement (FM) detection is essential for assessing prenatal health, as abnormal movement patterns can indicate underlying complications such as placental dysfunction or fetal distress. Traditional methods, including maternal perception and cardiotocography (CTG), suffer from subjectivity and limited accuracy. To address these challenges, we propose Contrastive Ultrasound Video Representation Learning (CURL), a novel self-supervised learning framework for FM detection from extended fetal ultrasound video recordings. Our approach leverages a dual-contrastive loss, incorporating both spatial and temporal contrastive learning, to learn robust motion representations. Additionally, we introduce a task-specific sampling strategy, ensuring the effective separation of movement and non-movement segments during self-supervised training, while enabling flexible inference on arbitrarily long ultrasound recordings through a probabilistic fine-tuning approach. Evaluated on an in-house dataset of 92 subjects, each with 30-minute ultrasound sessions, CURL achieves a sensitivity of 78.01% and an AUROC of 81.60%, demonstrating its potential for reliable and objective FM analysis. These results highlight the potential of self-supervised contrastive learning for fetal movement analysis, paving the way for improved prenatal monitoring and clinical decision-making. Our code is available at: https://github.com/Mr-TalhaIlyas/CURL/.
- 24 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. PP (21682194) , 1-14
Towards Objective Obstetric Ultrasound Assessment: Contrastive Representation Learning for Fetal Movement Detection
Accurate fetal movement (FM) detection is essential for assessing prenatal health, as abnormal movement patterns can indicate underlying complications such as placental dysfunction or fetal distress. Traditional methods, including maternal perception and cardiotocography (CTG), suffer from subjectivity and limited accuracy. To address these challenges, we propose Contrastive Ultrasound Video Representation Learning (CURL), a novel self-supervised learning framework for FM detection from extended fetal ultrasound video recordings. Our approach leverages a dual-contrastive loss, incorporating both spatial and temporal contrastive learning, to learn robust motion representations. Additionally, we introduce a task-specific sampling strategy, ensuring the effective separation of movement and non-movement segments during self-supervised training, while enabling flexible inference on arbitrarily long ultrasound recordings through a probabilistic fine-tuning approach. Evaluated on an in-house dataset of 92 subjects, each with 30-minute ultrasound sessions, CURL achieves a sensitivity of 78.01% and an AUROC of 81.60%, demonstrating its potential for reliable and objective FM analysis. These results highlight the potential of self-supervised contrastive learning for fetal movement analysis, paving the way for improved prenatal monitoring and clinical decision-making. Our code is available at: https://github.com/Mr-TalhaIlyas/CURL/.
- Open Access
- 14 January 2026
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 49 (4)
Fetal sleep: a cross-species review of physiology, measurement, and classification
Study Objectives: Fetal sleep is a vital yet underexplored aspect of prenatal neurodevelopment. Its cyclic organization reflects the maturation of central neural circuits, and disturbances in these patterns may offer some of the earliest detectable signs of neurological compromise. This is the first review to integrate more than seven decades of research into a unified, cross-species synthesis of fetal sleep. We examine: (1) Physiology and Ontogeny—comparing human fetuses with animal models; and (2) Methodological Evolution—transitioning from invasive neurophysiology to non-invasive monitoring and deep learning frameworks. Methods: A structured narrative synthesis was guided by a systematic literature search across four databases (PubMed, Scopus, IEEE Xplore, and Google Scholar). From 2925 identified records, 169 studies involving fetal sleep-related physiology, sleep-state classification, or signal-based monitoring were included in this review. Results: Across the 169 studies, fetal sleep states become clearly observable as the brain matures. In fetal sheep and baboons, organized cycling between active and quiet sleep emerges at approximately 80%–90% gestation. In humans, this differentiation occurs later, around 95% gestation, with full maturation reached near term. Despite extensive animal research, no unified, clinically validated framework exists for defining fetal sleep states, limiting translation into routine obstetric practice. Conclusions: By integrating evidence across species, methodologies, and clinical contexts, this review provides the scientific foundation for developing objective, multimodal, and non-invasive fetal sleep monitoring technologies—tools that may ultimately support earlier detection of neurological compromise and guide timely prenatal intervention.
- 14 January 2026
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 49 (4)
Open AccessFetal sleep: a cross-species review of physiology, measurement, and classification
Study Objectives: Fetal sleep is a vital yet underexplored aspect of prenatal neurodevelopment. Its cyclic organization reflects the maturation of central neural circuits, and disturbances in these patterns may offer some of the earliest detectable signs of neurological compromise. This is the first review to integrate more than seven decades of research into a unified, cross-species synthesis of fetal sleep. We examine: (1) Physiology and Ontogeny—comparing human fetuses with animal models; and (2) Methodological Evolution—transitioning from invasive neurophysiology to non-invasive monitoring and deep learning frameworks. Methods: A structured narrative synthesis was guided by a systematic literature search across four databases (PubMed, Scopus, IEEE Xplore, and Google Scholar). From 2925 identified records, 169 studies involving fetal sleep-related physiology, sleep-state classification, or signal-based monitoring were included in this review. Results: Across the 169 studies, fetal sleep states become clearly observable as the brain matures. In fetal sheep and baboons, organized cycling between active and quiet sleep emerges at approximately 80%–90% gestation. In humans, this differentiation occurs later, around 95% gestation, with full maturation reached near term. Despite extensive animal research, no unified, clinically validated framework exists for defining fetal sleep states, limiting translation into routine obstetric practice. Conclusions: By integrating evidence across species, methodologies, and clinical contexts, this review provides the scientific foundation for developing objective, multimodal, and non-invasive fetal sleep monitoring technologies—tools that may ultimately support earlier detection of neurological compromise and guide timely prenatal intervention.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. PP, 1-12
MMMuLNet: Multimodal Mutual Deep learning Framework for the Pediatric Congenital Heart Disease Detection
Congenital heart disease (CHD) is the most common birth defect and a major cause of infant morbidity and mortality worldwide. While echocardiography remains the diagnostic gold standard, its cost and reliance on expert interpretation limit availability in low- and middle-income countries (LMICs). This underscores the need for scalable, affordable, and robust approaches that can operate reliably under real-world signal degradation and low-quality recording conditions. In this study, we present a multimodal framework for pediatric CHD detection that integrates phonocardiograms (PCG), electrocardiograms (ECG), and clinical symptoms. Features from PCG and ECG were extracted using a pretrained foundation audio model, while key symptoms were selected using SHAP (SHapley Additive exPlanations) and encoded as structured embeddings. These modalities were combined in a fusion network with modality dropout to handle missing inputs, and mutual learning was applied to promote knowledge sharing across unimodal and multimodal branches. The framework was validated on a dataset of 751 pediatric patients in Bangladesh, comprising 3,435 synchronized PCG-ECG recordings with expert-confirmed labels. In 10-fold patient-wise cross validation, PCG alone achieved 90% accuracy, ECG alone 79%, and symptoms alone 73%. Combining PCG and ECG improved accuracy to 94%, while the full multimodal system reached 94.5% accuracy, 94.2% sensitivity, 95.6% specificity, and an AUROC of 96%. Importantly, even under degraded signal conditions when both PCG and ECG were of low quality, the multimodal framework maintained an accuracy of 88% and an AUROC of 87%, demonstrating superior performance compared to the unimodal models. These findings demonstrate that integrating PCG, ECG, and symptoms enables accurate, resilient CHD screening, offering a practical pathway for scalable early detection in LMICs.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. PP, 1-12
MMMuLNet: Multimodal Mutual Deep learning Framework for the Pediatric Congenital Heart Disease Detection
Congenital heart disease (CHD) is the most common birth defect and a major cause of infant morbidity and mortality worldwide. While echocardiography remains the diagnostic gold standard, its cost and reliance on expert interpretation limit availability in low- and middle-income countries (LMICs). This underscores the need for scalable, affordable, and robust approaches that can operate reliably under real-world signal degradation and low-quality recording conditions. In this study, we present a multimodal framework for pediatric CHD detection that integrates phonocardiograms (PCG), electrocardiograms (ECG), and clinical symptoms. Features from PCG and ECG were extracted using a pretrained foundation audio model, while key symptoms were selected using SHAP (SHapley Additive exPlanations) and encoded as structured embeddings. These modalities were combined in a fusion network with modality dropout to handle missing inputs, and mutual learning was applied to promote knowledge sharing across unimodal and multimodal branches. The framework was validated on a dataset of 751 pediatric patients in Bangladesh, comprising 3,435 synchronized PCG-ECG recordings with expert-confirmed labels. In 10-fold patient-wise cross validation, PCG alone achieved 90% accuracy, ECG alone 79%, and symptoms alone 73%. Combining PCG and ECG improved accuracy to 94%, while the full multimodal system reached 94.5% accuracy, 94.2% sensitivity, 95.6% specificity, and an AUROC of 96%. Importantly, even under degraded signal conditions when both PCG and ECG were of low quality, the multimodal framework maintained an accuracy of 88% and an AUROC of 87%, demonstrating superior performance compared to the unimodal models. These findings demonstrate that integrating PCG, ECG, and symptoms enables accurate, resilient CHD screening, offering a practical pathway for scalable early detection in LMICs.
- Open Access
- 28 November 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (48) , eady2661
An intelligent, compact wearable pressure-strain combo sensor system for continuous fetal movement monitoring
Continuous fetal movement monitoring in late pregnancy may improve fetal wellbeing and pregnancy outcomes. While fetal movements can be visualized with ultrasound, it is intermittent and limited to clinical settings. Inertial measurement units may enable at-home fetal monitoring but usually require a large-footprint, multisensor design. Here, we report smart, compact wearable pressure-strain combo sensors continuously monitoring fetal movements through maternal abdominal skin motions. In the 2D and 3D artificial abdomen systems, our octagonal-shaped gold nanowire–based strain sensor served as an isotropic sensor, enabling omnidirectional simulated “kicking load” detection within an area of ~77 (2D) and ~217 cm 2 (3D), while an interdigitated electrode–based pressure sensor showed highly sensitive localized load detection. Building upon these findings, we designed compact pressure- and strain-sensing integrated Band-Aids and tested on 59 pregnant women. We developed machine learning models to distinguish fetal from nonfetal movements with >90% accuracy in ultrasound-based validation studies. This AI-powered, Band-Aid–like sensing system offers potential as a compact, comfortable, and accurate continuous out-of-hospital fetal movement monitoring technology.
- 28 November 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (48) , eady2661
Open AccessAn intelligent, compact wearable pressure-strain combo sensor system for continuous fetal movement monitoring
Continuous fetal movement monitoring in late pregnancy may improve fetal wellbeing and pregnancy outcomes. While fetal movements can be visualized with ultrasound, it is intermittent and limited to clinical settings. Inertial measurement units may enable at-home fetal monitoring but usually require a large-footprint, multisensor design. Here, we report smart, compact wearable pressure-strain combo sensors continuously monitoring fetal movements through maternal abdominal skin motions. In the 2D and 3D artificial abdomen systems, our octagonal-shaped gold nanowire–based strain sensor served as an isotropic sensor, enabling omnidirectional simulated “kicking load” detection within an area of ~77 (2D) and ~217 cm 2 (3D), while an interdigitated electrode–based pressure sensor showed highly sensitive localized load detection. Building upon these findings, we designed compact pressure- and strain-sensing integrated Band-Aids and tested on 59 pregnant women. We developed machine learning models to distinguish fetal from nonfetal movements with >90% accuracy in ultrasound-based validation studies. This AI-powered, Band-Aid–like sensing system offers potential as a compact, comfortable, and accurate continuous out-of-hospital fetal movement monitoring technology.
- Open Access
- 9 September 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 197 (Pt A) , 110993
Automated detection of pediatric congenital heart disease from phonocardiograms using deep and handcrafted feature fusion
- 9 September 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 197 (Pt A) , 110993
Open AccessAutomated detection of pediatric congenital heart disease from phonocardiograms using deep and handcrafted feature fusion
- Open Access
Congenital Heart Disease Classification Using Phonocardiograms: A Scalable Screening Tool for Diverse Environments
Congenital heart disease (CHD) is a critical condition that demands early detection, particularly in infancy and childhood. This study presents a deep learning model designed to detect CHD using phonocardiogram (PCG) signals, with a focus on its application in global health. We evaluated our model on several datasets, including the primary dataset from Bangladesh, achieving a high accuracy of 94.1%, sensitivity of 92.7%, specificity of 96.3%. The model also demonstrated robust performance on the public PhysioNet Challenge 2022 and 2016 datasets, underscoring its generalizability to diverse populations and data sources. We assessed the performance of the algorithm for single and multiple auscultation sites on the chest, demonstrating that the model maintains over 85% accuracy even when using a single location. Furthermore, our algorithm was able to achieve an accuracy of 80% on low-quality recordings, which cardiologists deemed non-diagnostic. This research suggests that an AI- driven digital stethoscope could serve as a cost-effective screening tool for CHD in resource-limited settings, enhancing clinical decision support and ultimately improving patient outcomes.
Open AccessCongenital Heart Disease Classification Using Phonocardiograms: A Scalable Screening Tool for Diverse Environments
Congenital heart disease (CHD) is a critical condition that demands early detection, particularly in infancy and childhood. This study presents a deep learning model designed to detect CHD using phonocardiogram (PCG) signals, with a focus on its application in global health. We evaluated our model on several datasets, including the primary dataset from Bangladesh, achieving a high accuracy of 94.1%, sensitivity of 92.7%, specificity of 96.3%. The model also demonstrated robust performance on the public PhysioNet Challenge 2022 and 2016 datasets, underscoring its generalizability to diverse populations and data sources. We assessed the performance of the algorithm for single and multiple auscultation sites on the chest, demonstrating that the model maintains over 85% accuracy even when using a single location. Furthermore, our algorithm was able to achieve an accuracy of 80% on low-quality recordings, which cardiologists deemed non-diagnostic. This research suggests that an AI- driven digital stethoscope could serve as a cost-effective screening tool for CHD in resource-limited settings, enhancing clinical decision support and ultimately improving patient outcomes.
- Open Access
- 15 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 5, 345-352
NeoSSNet: Real-Time Neonatal Chest Sound Separation Using Deep Learning
Goal: Auscultation for neonates is a simple and non-invasive method of diagnosing cardiovascular and respiratory disease. However, obtaining high-quality chest sounds containing only heart or lung sounds is non-trivial. Hence, this study introduces a new deep-learning model named NeoSSNet and evaluates its performance in neonatal chest sound separation with previous methods. Methods: We propose a masked-based architecture similar to Conv-TasNet. The encoder and decoder consist of 1D convolution and 1D transposed convolution, while the mask generator consists of a convolution and transformer architecture. The input chest sounds were first encoded as a sequence of tokens using 1D convolution. The tokens were then passed to the mask generator to generate two masks, one for heart sounds and one for lung sounds. Each mask is then applied to the input token sequence. Lastly, the tokens are converted back to waveforms using 1D transposed convolution. Results: Our proposed model showed superior results compared to the previous methods based on objective distortion measures, ranging from a 2.01 dB improvement to a 5.06 dB improvement. The proposed model is also significantly faster than the previous methods, with at least a 17-time improvement. Conclusions: The proposed model could be a suitable preprocessing step for any health monitoring system where only the heart sound or lung sound is desired.
- 15 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 5, 345-352
Open AccessNeoSSNet: Real-Time Neonatal Chest Sound Separation Using Deep Learning
Goal: Auscultation for neonates is a simple and non-invasive method of diagnosing cardiovascular and respiratory disease. However, obtaining high-quality chest sounds containing only heart or lung sounds is non-trivial. Hence, this study introduces a new deep-learning model named NeoSSNet and evaluates its performance in neonatal chest sound separation with previous methods. Methods: We propose a masked-based architecture similar to Conv-TasNet. The encoder and decoder consist of 1D convolution and 1D transposed convolution, while the mask generator consists of a convolution and transformer architecture. The input chest sounds were first encoded as a sequence of tokens using 1D convolution. The tokens were then passed to the mask generator to generate two masks, one for heart sounds and one for lung sounds. Each mask is then applied to the input token sequence. Lastly, the tokens are converted back to waveforms using 1D transposed convolution. Results: Our proposed model showed superior results compared to the previous methods based on objective distortion measures, ranging from a 2.01 dB improvement to a 5.06 dB improvement. The proposed model is also significantly faster than the previous methods, with at least a 17-time improvement. Conclusions: The proposed model could be a suitable preprocessing step for any health monitoring system where only the heart sound or lung sound is desired.
- 26 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (23) , 29513-29524
Investigating Physiological and Behavioral Sensing Modalities Toward Drowsiness Detection
Monitoring driver drowsiness is a crucial aspect of ensuring road safety. Many studies have explored a variety of physiological signals and behavioural monitoring of drivers using video, or a combination of these approaches. In this paper, we investigate and optimise the effectiveness of various modalities to monitor drowsiness. We developed a physiological model using Electrocenography, Electromyography, Electrooculography and Electrocardiography recordings. A video-based behavioural model was then developed, utilising a pre-trained ResNet-101, face landmarks and handcrafted features for feature extraction, followed by classification with two Long-Short-Term memory blocks. We also investigated a combination of these models using decision fusion to form a hybrid model. The proposed method was trained and evaluated on the publicly available database (DROZY) and compared to other methods on the same database. Our proposed physiological and behavioural models were separately compared with previous approaches where we demonstrated their superior performance when appropriately validated. We further improved the results by combining the physiological and behavioural models which detected drowsiness in 93.10% of trials through leave-one-subject-out cross-validation.
- 26 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (23) , 29513-29524
Investigating Physiological and Behavioral Sensing Modalities Toward Drowsiness Detection
Monitoring driver drowsiness is a crucial aspect of ensuring road safety. Many studies have explored a variety of physiological signals and behavioural monitoring of drivers using video, or a combination of these approaches. In this paper, we investigate and optimise the effectiveness of various modalities to monitor drowsiness. We developed a physiological model using Electrocenography, Electromyography, Electrooculography and Electrocardiography recordings. A video-based behavioural model was then developed, utilising a pre-trained ResNet-101, face landmarks and handcrafted features for feature extraction, followed by classification with two Long-Short-Term memory blocks. We also investigated a combination of these models using decision fusion to form a hybrid model. The proposed method was trained and evaluated on the publicly available database (DROZY) and compared to other methods on the same database. Our proposed physiological and behavioural models were separately compared with previous approaches where we demonstrated their superior performance when appropriately validated. We further improved the results by combining the physiological and behavioural models which detected drowsiness in 93.10% of trials through leave-one-subject-out cross-validation.