SMSurendra Maharjan

Surendra Maharjan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Surendra Maharjan has a total of 69 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Brainstem subfield volume alterations in COVID-19 patients: Implications for respiratory and arousal circuits

    by Md Mamun Al-Amin, Mst Shahnaj Pervin, Syed Zaheed Kamal, Md Iqbal Shahid, Surendra Maharjan, Ahm Ruhul Quddus

  • Open Access

    Worse visibility of deep medullary veins is associated with larger lateral ventricles but not with cortical thickness

    by Sushruth Manchineella, Henry Rusinek, Yuan Ma, Xiuyuan Hugh Wang, Surendra Maharjan, Liangdong Zhou, Tracy Butler, Yi Li, Alexus Jones, Emily Tanzi, et al.


  • Open Access

    Diffusion tractography of kidney by high angular resolution diffusion imaging

    by Surendra Maharjan, Jie Chen, Adrienne Gaughan, Neal X. Chen, Nian Wang

    Diffusion magnetic resonance imaging (MRI) has been utilized to probe the renal microstructures but investigating the three-dimensional (3D) tubular network still presents significant challenges due to the complicated architecture of kidney. This study aims to assess whether high angular resolution diffusion imaging (HARDI) could improve the reconstruction of 3D tubular architectures. Kidneys from both mice and rats were imaged using 3D diffusion-weighted pulse sequences at 9.4 T. Five healthy mouse kidneys were scanned at an isotropic spatial resolution of 40 μm, with a b value of 1500 s/mm2 across 46 diffusion encoding directions. The study employed diffusion tensor imaging (DTI) and generalized Q-sampling imaging (GQI) to examine the tubular orientation distributions and tractography, validated by conventional histology. Fractional anisotropy (FA) and mean diffusivity (MD) were quantified and compared among the inner medullar (IM), outer medullar (OM), and cortex (CO) at different angular resolutions. FA values, estimated with 6 diffusion-weighted images (DWIs), were significantly overestimated by 49.9% (p < 0.001) in IM, 179.4% (p < 0.001) in OM, and 225.5% (p < 0.001) in CO, compared to using 46 DWIs. In contrast, MD exhibited less variations to angular resolution variations (3.4% in IM, 4.2% in OM, and 4.6% in CO). Both DTI and GQI at high angular resolution successfully traced renal tubular structures throughout the kidney, with GQI demonstrating superior performance in generating more continuous tracts. Furthermore, disrupted renal tubule structures were observed in a chronic kidney disease (CKD) rat model. HARDI, especially when combined with the GQI approach, holds promise in tracking complicated 3D tubule architectures and may serve as a potent tool for kidney disease research.


  • Open Access

    Scan With Me: A Train-the-Trainer Program to Upskill MRI Personnel in Low- and Middle-Income Countries

    by Abdul Nashirudeen Mumuni, Katerina Eyre, Cristian Montalba, Aduluwa Harrison, Surendra Maharjan, Francis Botwe, Marina Fernandez Garcia, Abderrazek Zeraii, Matthias G. Friedrich, Abiodun Fatade, et al.


  • Open Access

    Comparison of Size specific dose estimates (SSDE) and CTDIvol values in patients undergoing CT examinations of abdomen and pelvis

    by Sweta Joshi, Sharma Paudel, Shanta Lall Shrestha, Surendra Maharjan

    Introduction: Computed Tomography Dose Index volume (CTDIvol) is a measure of radiation output of the CT scanner and does not represent patient dose. It often underestimates the radiation dose being given to small children and smaller adults and overestimates the dose to larger patients. The use of Size Specific Dose Index (SSDE) helps convert CTDIvol into more patient size specific radiation dose and is a better measure of estimated patient dose than CTDIvol. Methods: This cross-sectional study was conducted in the Department of Radiology and Imaging of Tribhuvan University Teaching Hospital (TUTH), Maharajgunj, Nepal. CT scans were performed on the Siemens Somaton Definition AS+ 128 slice scanner. During 96 CT examinations of the abdomen and pelvis collected over a period of 4 months, effective diameters were calculated from the AP and Lateral diameters at the mid-liver region. These were used to determine the conversion factors which were then used to convert the CTDIvol values to SSDE. Obtained SSDE values were compared with the displayed CTDIvol values. Results: The average CTDIvol was found to be 9.42 ± 3.26 mGy and the average SSDE was found to be 13.48 ± 3.53 mGy. Moderate positive correlation (r=+0.52, p<0.001) was found between CTDIvol and patient weight and low positive correlation (r=+0.17, p=0.08) was found between SSDE and patient weight. Similarly, moderate positive correlation (r=+0.5, p<0.001) was found between CTDIvol and patient BMI and low positive correlation (r=+0.14, p=0.15) was found between SSDE and patient BMI. Conclusion: In comparison with SSDE, CTDIvol seemed to underestimate the patient dose estimate by 30.11%. CTDIvol values showed dependency with patient weight and BMI, this dependency was significantly reduced when those values were converted into SSDE (i.e. r=+0.52, p<0.001 (CTDIvol and Patient weight) vs. r=+0.17, p=0.08 (SSDE and Patient weight) and r=+0.5, p<0.001 (CTDIvol and BMI) vs. r=+0.14, p=0.15 (SSDE and BMI). Thus, providing more concrete evidence to the fact that SSDE values are a more reliable patient dose estimate since it addresses the patient’s size.


  • Super-Resolution MRH Reconstruction for Mouse Models

    by Juhyung Ha, Nian Wang, Surendra Maharjan, Xuhong Zhang

  • Open Access

    Knowledge of radiation protection among dental students in a medical college, Nepal

    by Karuna Raya Chhetri, Sushma Singh, Icchya Tamrakar, Usha Poudel Lamgade, Susmita Shrestha, Nian Wang, Surendra Maharjan

    Introduction: Radiation protection is a core component of radiographic practice and provides optimal patient safety and control of radiation hazards. In this study, we aim to determine the knowledge of radiation protection among dental students in a medical college, in Nepal.Materials and methods: Bachelor’s degree dental final year students studying at Gandaki Medical College (GMC), Pokhara, Nepal were included in this study. A questionnaire survey tool was developed by consulting with two lecturers of medical imaging technology who have more than 10 years of experience. 10 multiple-choice questions (MCQs) were handed to each participant. Each correct answer was given a “1” score and each incorrect answer was given a “0” score. There were no negative markings. The knowledge score was categorized as <60 % inadequate, 60–80 % adequate, and 80–100% excellent. Data were coded and analyzed in IBM SPSS statistics, version 28, Chicago, United States. The normality of the data was checked by using the Shapiro-Wilk test. The equality of variance was assessed by Levene’s test. The p-value was set at a 5% level of significance. Two sample ttest was applied since the data followed a normal distribution. Results: A total of 16 dental students, 5 males, and 11 females, 22.06±0.77 mean age, 20-23 age range were included in this study. Participants did not have prior training in radiation protection. The mean knowledge of radiation protection score was 52.5%, 5.25±1.52, with a maximum score of 8 and a minimum 3 of which was inadequate. There was a statistically significant difference in knowledge according to gender, p=0.01, t(14)=2.92. The mean response was 60% (adequate) for 21-year-old participants and was inadequate at other ages. Conclusion: The knowledge of radiation protection should be improved among dental students. Adequate course materials and training should be included in their curriculum. Radiation protection national regulations should be implemented as soon as possible.

  • Open Access

    Clinical audit of computed tomography requisition form in a himalayan country, Nepal

    by Anjan Dangal, Surendra Maharjan

    Introduction: Medical imaging requisition form is a vital document in the radiology department. Adequate filling ensures justification and effective communication which impacts patient care. This study aims to audit computed tomography (CT) requisition forms to determine their adequate filling and legibility in the Himalayan country, Nepal. Methods: A total of 239 CT requisition forms were collected from the Department of Radiology and Imaging, Bir Hospital, Kathmandu, Nepal through random sampling from June to August 2020. The availability of information such as demographic characteristics, clinical history, clinical diagnosis, differential diagnosis, and proper name of CT procedures was audited. The legibility of the provided information was categorized with the help of a senior radiographer having 10 years of experience. Results: Clinical history was present in 28 percent and clinical diagnosis in 64 percent of forms. Furthermore, 44 percent of contrast-enhanced procedures requiring IV contrast agents did not have a report of renal function test. Surprisingly, details on the last menstrual period for women of the reproductive age group were missing in all requisition forms. Conclusion: Available information is not sufficient for justification of patient dose. Clinicians need to fill up the requisition form properly for quality patient care in the radiology department.


  • Open Access

    Pregnancy intentions and its associated factors among married women in resunga, Gulmi, Nepal

    by Rita Karki, Surendra Maharjan, Ganesh Khatiwada, Junu Shrestha

    En’s health outcomes. Unintended pregnancy is a contributing factor for maternal and infant mortality, which is still high in Nepal. Reproductive and family planning program should incorporate pregnancy intention domains in health education and counseling with priority to design program to address and reduce unintended pregnancy. This brief research examines the pregnancy intentions and its associated factors among married women so that it could identify the intentions of pregnancy and factors influencing unintended pregnancy and could be useful to improve and maintain the health and well-being of women, family, community, and nation....