Kristopher Pataky
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kristopher Pataky has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
Juergen Brugger
Microsystems Laboratory, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
5 shared publicationsAna Valero
LMIS4, EPFL, 1015 Lausanne, Switzerland
2 shared publications- Christopher Cao
Department of Cardiothoracic Surgery, Royal Prince Alfred Hospital, Sydney University, Sydney, NSW 2050, Australia
2 shared publications J. Brugger
2 shared publicationsJürgen Brugger
LMIS1, EPFL, 1015 Lausanne, Switzerland
2 shared publicationsLudovica Colella
LMIS4, EPFL, 1015 Lausanne, Switzerland
2 shared publications
Latest Publications
- Top Cited Papers
- 1 February 2014
- Published by Elsevier in Lung Cancer
- Vol. 83 (2) , 240-245
A systematic review and meta-analysis of surgical treatments for malignant pleural mesothelioma
- 1 February 2014
- Published by Elsevier in Lung Cancer
- Vol. 83 (2) , 240-245
Top Cited PapersA systematic review and meta-analysis of surgical treatments for malignant pleural mesothelioma
- 1 January 2014
- Published by Elsevier
- p. 75-96
Rapid prototyping techniques for the fabrication of biosensors
- 1 January 2014
- Published by Elsevier
- p. 75-96
Rapid prototyping techniques for the fabrication of biosensors
- 1 September 2013
- Published by Elsevier in Lung Cancer
- Vol. 81 (3) , 319-327
Systematic review of pleurectomy in the treatment of malignant pleural mesothelioma
- 1 September 2013
- Published by Elsevier in Lung Cancer
- Vol. 81 (3) , 319-327
Systematic review of pleurectomy in the treatment of malignant pleural mesothelioma
- 12 June 2012
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry
- Vol. 22 (28) , 14030-14034
Carbon nanotubes–SU8 composite for flexible conductive inkjet printable applications
We have developed a conducting composite based on multi-walled carbon nanotubes and bisphenol A novolak epoxy resin (SU8) for inkjet printing purposes. We could deposit regular conducting stripes and arrays of 150 μm spots on glass and on flexible polyethylene terephthalate (PET) films. The UV and temperature processed structures show very good adhesion and reasonably good resistivity with a low concentration of carbon nanotubes. Our composite material for inkjet deposition is completely compatible with current MEMS fabrication processes.
- 12 June 2012
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry
- Vol. 22 (28) , 14030-14034
Carbon nanotubes–SU8 composite for flexible conductive inkjet printable applications
We have developed a conducting composite based on multi-walled carbon nanotubes and bisphenol A novolak epoxy resin (SU8) for inkjet printing purposes. We could deposit regular conducting stripes and arrays of 150 μm spots on glass and on flexible polyethylene terephthalate (PET) films. The UV and temperature processed structures show very good adhesion and reasonably good resistivity with a low concentration of carbon nanotubes. Our composite material for inkjet deposition is completely compatible with current MEMS fabrication processes.
- Open Access
- 26 May 2012
- Published by Springer Nature in Biomedical Microdevices
- Vol. 14 (5) , 819-828
Polyimide/SU-8 catheter-tip MEMS gauge pressure sensor
This paper describes the development of a polyimide/SU-8 catheter-tip MEMS gauge pressure sensor. Finite element analysis was used to investigate critical parameters, impacting on the device design and sensing characteristics. The sensing element of the device was fabricated by polyimide-based micromachining on a flexible membrane, using embedded thin-film metallic wires as piezoresistive elements. A chamber containing this flexible membrane was sealed using an adapted SU-8 bonding technique. The device was evaluated experimentally and its overall performance compared with a commercial silicon-based pressure sensor. Furthermore, the device use was demonstrated by measuring blood pressure and heart rate in vivo.
- 26 May 2012
- Published by Springer Nature in Biomedical Microdevices
- Vol. 14 (5) , 819-828
Open AccessPolyimide/SU-8 catheter-tip MEMS gauge pressure sensor
This paper describes the development of a polyimide/SU-8 catheter-tip MEMS gauge pressure sensor. Finite element analysis was used to investigate critical parameters, impacting on the device design and sensing characteristics. The sensing element of the device was fabricated by polyimide-based micromachining on a flexible membrane, using embedded thin-film metallic wires as piezoresistive elements. A chamber containing this flexible membrane was sealed using an adapted SU-8 bonding technique. The device was evaluated experimentally and its overall performance compared with a commercial silicon-based pressure sensor. Furthermore, the device use was demonstrated by measuring blood pressure and heart rate in vivo.
- 20 January 2012
- Published by IOP Publishing in Nanotechnology
- Vol. 23 (7) , 075701
Nanocomposites based on highly luminescent nanocrystals and semiconducting conjugated polymer for inkjet printing
In this work nanocomposites based on organic-capped semiconductor nanocrystals formed of a core of CdSe coated with a shell of ZnS (CdSe@ZnS), with different sizes, and a semiconducting conjugated polymer, namely poly[(9,9-dihexylfluoren-2,7-diyl)-alt- (2,5-dimethyl-1,4-phenylene)] (PF-DMB) have been investigated. The nanocomposites are prepared by mixing the pre-synthesized components in organic solvents, thereby assisting the dispersion of the organic-coated nano-objects in the polymer host. UV-vis steady state and time-resolved spectroscopy along with (photo)electrochemical techniques have been performed to characterize the obtained materials. The study shows that the embedded nanocrystals increase the PF-DMB stability against oxidation and, at the same time, extend the light harvesting capability to the visible spectral region, thus resulting in detectable photocurrent signals. The nanocomposites have been dispensed by means of a piezo-actuated inkjet system. Such inks present viscosity and surface tension properties well suited for stable and reliable drop-on-demand printing using an inkjet printer. The fabrication of arrays of single-color pixels made of the nanocomposites and micrometers in size has been performed. Confocal and atomic force microscopy have confirmed that inkjet-printed microstructures present the intrinsic emission properties of both the embedded nanocrystals and PF-DMB, resulting in a combined luminescence. Finally, the morphology of the printed pixels is influenced by the embedded nanofillers.
- 20 January 2012
- Published by IOP Publishing in Nanotechnology
- Vol. 23 (7) , 075701
Nanocomposites based on highly luminescent nanocrystals and semiconducting conjugated polymer for inkjet printing
In this work nanocomposites based on organic-capped semiconductor nanocrystals formed of a core of CdSe coated with a shell of ZnS (CdSe@ZnS), with different sizes, and a semiconducting conjugated polymer, namely poly[(9,9-dihexylfluoren-2,7-diyl)-alt- (2,5-dimethyl-1,4-phenylene)] (PF-DMB) have been investigated. The nanocomposites are prepared by mixing the pre-synthesized components in organic solvents, thereby assisting the dispersion of the organic-coated nano-objects in the polymer host. UV-vis steady state and time-resolved spectroscopy along with (photo)electrochemical techniques have been performed to characterize the obtained materials. The study shows that the embedded nanocrystals increase the PF-DMB stability against oxidation and, at the same time, extend the light harvesting capability to the visible spectral region, thus resulting in detectable photocurrent signals. The nanocomposites have been dispensed by means of a piezo-actuated inkjet system. Such inks present viscosity and surface tension properties well suited for stable and reliable drop-on-demand printing using an inkjet printer. The fabrication of arrays of single-color pixels made of the nanocomposites and micrometers in size has been performed. Confocal and atomic force microscopy have confirmed that inkjet-printed microstructures present the intrinsic emission properties of both the embedded nanocrystals and PF-DMB, resulting in a combined luminescence. Finally, the morphology of the printed pixels is influenced by the embedded nanofillers.
- Open Access
- 27 September 2011
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 6 (9) , e25459
Nano-Stenciled RGD-Gold Patterns That Inhibit Focal Contact Maturation Induce Lamellipodia Formation in Fibroblasts
Cultured fibroblasts adhere to extracellular substrates by means of cell-matrix adhesions that are assembled in a hierarchical way, thereby gaining in protein complexity and size. Here we asked how restricting the size of cell-matrix adhesions affects cell morphology and behavior. Using a nanostencil technique, culture substrates were patterned with gold squares of a width and spacing between 250 nm and 2 µm. The gold was functionalized with RGD peptide as ligand for cellular integrins, and mouse embryo fibroblasts were plated. Limiting the length of cell-matrix adhesions to 500 nm or less disturbed the maturation of vinculin-positive focal complexes into focal contacts and fibrillar adhesions, as indicated by poor recruitment of α5-integrin. We found that on sub-micrometer patterns, fibroblasts spread extensively, but did not polarize. Instead, they formed excessive numbers of lamellipodia and a fine actin meshwork without stress fibers. Moreover, these cells showed aberrant fibronectin fibrillogenesis, and their speed of directed migration was reduced significantly compared to fibroblasts on 2 µm square patterns. Interference with RhoA/ROCK signaling eliminated the pattern-dependent differences in cell morphology. Our results indicate that manipulating the maturation of cell-matrix adhesions by nanopatterned surfaces allows to influence morphology, actin dynamics, migration and ECM assembly of adhering fibroblasts.
- 27 September 2011
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 6 (9) , e25459
Open AccessNano-Stenciled RGD-Gold Patterns That Inhibit Focal Contact Maturation Induce Lamellipodia Formation in Fibroblasts
Cultured fibroblasts adhere to extracellular substrates by means of cell-matrix adhesions that are assembled in a hierarchical way, thereby gaining in protein complexity and size. Here we asked how restricting the size of cell-matrix adhesions affects cell morphology and behavior. Using a nanostencil technique, culture substrates were patterned with gold squares of a width and spacing between 250 nm and 2 µm. The gold was functionalized with RGD peptide as ligand for cellular integrins, and mouse embryo fibroblasts were plated. Limiting the length of cell-matrix adhesions to 500 nm or less disturbed the maturation of vinculin-positive focal complexes into focal contacts and fibrillar adhesions, as indicated by poor recruitment of α5-integrin. We found that on sub-micrometer patterns, fibroblasts spread extensively, but did not polarize. Instead, they formed excessive numbers of lamellipodia and a fine actin meshwork without stress fibers. Moreover, these cells showed aberrant fibronectin fibrillogenesis, and their speed of directed migration was reduced significantly compared to fibroblasts on 2 µm square patterns. Interference with RhoA/ROCK signaling eliminated the pattern-dependent differences in cell morphology. Our results indicate that manipulating the maturation of cell-matrix adhesions by nanopatterned surfaces allows to influence morphology, actin dynamics, migration and ECM assembly of adhering fibroblasts.
- 25 February 2011
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (6) , 2234-2242
Link between Alginate Reaction Front Propagation and General Reaction Diffusion Theory
We provide a common theoretical framework reuniting specific models for the Ca2+-alginate system and general reaction diffusion theory along with experimental validation on a microfluidic chip. As a starting point, we use a set of nonlinear, partial differential equations that are traditionally solved numerically: the Mikkelsen−Elgsaeter model. Applying the traveling-wave hypothesis as a major simplification, we obtain an analytical solution. The solution indicates that the fundamental properties of the alginate reaction front are governed by a single dimensionless parameter λ. For small λ values, a large depletion zone accompanies the reaction front. For large λ values, the alginate reacts before having the time to diffuse significantly. We show that the λ parameter is of general importance beyond the alginate model system, as it can be used to classify known solutions for second-order reaction diffusion schemes, along with the novel solution presented here. For experimental validation, we develop a microchip model system, in which the alginate gel formation can be carried out in a highly controlled, essentially 1D environment. The use of a filter barrier enables us to rapidly renew the CaCl2 solution, while maintaining flow speeds lower than 1 μm/s for the alginate compartment. This allows one to impose an exactly known bulk CaCl2 concentration and diffusion resistance. This experimental model system, taken together with the theoretical development, enables the determination of the entire set of physicochemical parameters governing the alginate reaction front in a single experiment.
- 25 February 2011
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (6) , 2234-2242
Link between Alginate Reaction Front Propagation and General Reaction Diffusion Theory
We provide a common theoretical framework reuniting specific models for the Ca2+-alginate system and general reaction diffusion theory along with experimental validation on a microfluidic chip. As a starting point, we use a set of nonlinear, partial differential equations that are traditionally solved numerically: the Mikkelsen−Elgsaeter model. Applying the traveling-wave hypothesis as a major simplification, we obtain an analytical solution. The solution indicates that the fundamental properties of the alginate reaction front are governed by a single dimensionless parameter λ. For small λ values, a large depletion zone accompanies the reaction front. For large λ values, the alginate reacts before having the time to diffuse significantly. We show that the λ parameter is of general importance beyond the alginate model system, as it can be used to classify known solutions for second-order reaction diffusion schemes, along with the novel solution presented here. For experimental validation, we develop a microchip model system, in which the alginate gel formation can be carried out in a highly controlled, essentially 1D environment. The use of a filter barrier enables us to rapidly renew the CaCl2 solution, while maintaining flow speeds lower than 1 μm/s for the alginate compartment. This allows one to impose an exactly known bulk CaCl2 concentration and diffusion resistance. This experimental model system, taken together with the theoretical development, enables the determination of the entire set of physicochemical parameters governing the alginate reaction front in a single experiment.
- 6 September 2010
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 10 (20) , 2771-2777
Fluidic microstructuring of alginate hydrogels for the single cell niche
Controlling alginate gel formation by diffusion of Ca2+ ions through a filter barrier, a layer-by-layer deposition technique with resolution on the size scale of a single cell is presented. It offers the possibility of exposing cells under biocompatible conditions to microheterogeneous three-dimensional environments, mimicking the layered structure of extracellular matrix in tissues.
- 6 September 2010
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 10 (20) , 2771-2777
Fluidic microstructuring of alginate hydrogels for the single cell niche
Controlling alginate gel formation by diffusion of Ca2+ ions through a filter barrier, a layer-by-layer deposition technique with resolution on the size scale of a single cell is presented. It offers the possibility of exposing cells under biocompatible conditions to microheterogeneous three-dimensional environments, mimicking the layered structure of extracellular matrix in tissues.
- Open Access
- 1 August 2009
- Published by Radiation Research Society in Radiation Research
- Vol. 172 (2) , 252-259
Microcollimator for Micrometer-Wide Stripe Irradiation of Cells Using 20–30 keV X Rays
Pataky, K., Villanueva, G., Liani, A., Zgheib, O., Jenkins, N., Halazonetis, D. J., Halazonetis, T. D. and Brugger, J. Microcollimator for Micrometer-Wide Stripe Irradiation of Cells Using 20-30 keV X Rays. Radiat. Res. 172, 252-259 (2009). The exposure of subnuclear compartments of cells to ionizing radiation is currently not trivial. We describe here a collimator for micrometer-wide stripe irradiation designed to work with conventional high-voltage X-ray tubes and cells cultured on standard glass cover slips. The microcollimator was fabricated by high-precision silicon micromachining and consists of X-ray absorbing chips with grooves of highly controlled depths, between 0.5-10 microm, along their surfaces. These grooves form X-ray collimating slits when the chips are stacked against each other. The use of this device for radiation biology was examined by irradiating human cells with X rays having energies between 20-30 keV. After irradiation, p53 binding protein 1 (53BP1), a nuclear protein that is recruited at sites of DNA double-strand breaks, clustered in lines corresponding to the irradiated stripes.
- 1 August 2009
- Published by Radiation Research Society in Radiation Research
- Vol. 172 (2) , 252-259
Open AccessMicrocollimator for Micrometer-Wide Stripe Irradiation of Cells Using 20–30 keV X Rays
Pataky, K., Villanueva, G., Liani, A., Zgheib, O., Jenkins, N., Halazonetis, D. J., Halazonetis, T. D. and Brugger, J. Microcollimator for Micrometer-Wide Stripe Irradiation of Cells Using 20-30 keV X Rays. Radiat. Res. 172, 252-259 (2009). The exposure of subnuclear compartments of cells to ionizing radiation is currently not trivial. We describe here a collimator for micrometer-wide stripe irradiation designed to work with conventional high-voltage X-ray tubes and cells cultured on standard glass cover slips. The microcollimator was fabricated by high-precision silicon micromachining and consists of X-ray absorbing chips with grooves of highly controlled depths, between 0.5-10 microm, along their surfaces. These grooves form X-ray collimating slits when the chips are stacked against each other. The use of this device for radiation biology was examined by irradiating human cells with X rays having energies between 20-30 keV. After irradiation, p53 binding protein 1 (53BP1), a nuclear protein that is recruited at sites of DNA double-strand breaks, clustered in lines corresponding to the irradiated stripes.