Chanki Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chanki Lee has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Hee Reyoung Kim
Ulsan National Institute of Science and Technology
4 shared publications - Wi-Ho Ha
2)Nuclear Emergency Preparedness Section, Korea Atomic Energy Research Institute, Daejeon, Korea
2 shared publications Hee Reyoung Kim
1 shared publicationHyeonmin Lee
1 shared publication- Hyun Ki Kim
2)Nuclear Emergency Preparedness Section, Korea Atomic Energy Research Institute, Daejeon, Korea
1 shared publication - Hyunwoo Lee
1)Department of Nuclear Engineering, Hanyang University, Seoul, Korea
1 shared publication
Latest Publications
- Open Access
- 12 February 2025
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 57 (8)
Comparative evaluation of thyroid operational intervention levels depending on age and biokinetic model in nuclear accidents
- 12 February 2025
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 57 (8)
Open AccessComparative evaluation of thyroid operational intervention levels depending on age and biokinetic model in nuclear accidents
- Open Access
- 30 December 2021
- Published by Korean Association for Radiation Protection in Journal of Radiation Protection and Research
- Vol. 46 (4) , 194-203
Preliminary Study on Rapid Measurement of Gross Alpha/Beta and 90Sr Activities in Surface Soil by Mobile ZnS(Ag)/PTV Array and Handheld PVT Rod with Gated Energy Channels
Background: Surface soil radiation monitoring around nuclear facilities is important to classify and characterize the contaminated areas. A scanning and direct measurement technique can survey the sites rapidly before starting sampling analysis.Materials and Methods: Regarding this, we test and suggest a measurement technique for gross alpha/beta and 90Sr activities in surface soil based on a mobile ZnS(Ag)/PVT (polyvinyltoluene) array and a handheld PVT rod, respectively. To detect 90Sr selectively in soil mixed with naturally occurring radioactive materials, chosen energy channel counts from the multichannel analyzers were used instead of whole channel counts. Soil samples contaminated with exempt liquid 90Sr with 1 Bq· g-1, 3 Bq· g-1, and 10 Bq· g-1 were prepared and hardened by flocculation.Results and Discussion: The mobile ZnS(Ag)/PVT array could discriminate gross alpha, gross beta, and gamma radiation by the different pulse-shaped signal features of each sensor material. If the array is deployed on a vehicle, the scan minimum detectable concentration (MDC) range will be about 0.11–0.17 Bq· g-1 at 18 km· hr-1 speed, highly sensitive to actual sites. The handheld PVT rod with 12 mm (Φ) × 20 mm (H) size can directly measure 90Sr selectively if channels on which energies are from 1,470 and 2,279 keV are gated, minimizing crossdetection of other radionuclides. These methods were verified by measuring soil samples fabricated with homogeneous 90Sr concentrations, showing static MDC of 2.16 Bq· g-1 at a measurement time of 300 seconds.Conclusion: Based on the results, comprehensive procedures using these detectors are suggested to optimize soil sites survey.
- 30 December 2021
- Published by Korean Association for Radiation Protection in Journal of Radiation Protection and Research
- Vol. 46 (4) , 194-203
Open AccessPreliminary Study on Rapid Measurement of Gross Alpha/Beta and 90Sr Activities in Surface Soil by Mobile ZnS(Ag)/PTV Array and Handheld PVT Rod with Gated Energy Channels
Background: Surface soil radiation monitoring around nuclear facilities is important to classify and characterize the contaminated areas. A scanning and direct measurement technique can survey the sites rapidly before starting sampling analysis.Materials and Methods: Regarding this, we test and suggest a measurement technique for gross alpha/beta and 90Sr activities in surface soil based on a mobile ZnS(Ag)/PVT (polyvinyltoluene) array and a handheld PVT rod, respectively. To detect 90Sr selectively in soil mixed with naturally occurring radioactive materials, chosen energy channel counts from the multichannel analyzers were used instead of whole channel counts. Soil samples contaminated with exempt liquid 90Sr with 1 Bq· g-1, 3 Bq· g-1, and 10 Bq· g-1 were prepared and hardened by flocculation.Results and Discussion: The mobile ZnS(Ag)/PVT array could discriminate gross alpha, gross beta, and gamma radiation by the different pulse-shaped signal features of each sensor material. If the array is deployed on a vehicle, the scan minimum detectable concentration (MDC) range will be about 0.11–0.17 Bq· g-1 at 18 km· hr-1 speed, highly sensitive to actual sites. The handheld PVT rod with 12 mm (Φ) × 20 mm (H) size can directly measure 90Sr selectively if channels on which energies are from 1,470 and 2,279 keV are gated, minimizing crossdetection of other radionuclides. These methods were verified by measuring soil samples fabricated with homogeneous 90Sr concentrations, showing static MDC of 2.16 Bq· g-1 at a measurement time of 300 seconds.Conclusion: Based on the results, comprehensive procedures using these detectors are suggested to optimize soil sites survey.
- Open Access
Gamma-Ray Sensor Using YAlO3(Ce) Single Crystal and CNT/PEEK with High Sensitivity and Stability under Harsh Underwater Conditions
A new gamma-ray sensor, which could be employed in harsh underwater conditions, was developed using YAlO3(Ce) single crystal and carbon nanotube reinforced polyetheretherketone (CNT/PEEK). The sensor is compact, highly sensitive and stable, by providing real-time gross counts and an accumulated spectrum for fresh, saline, or contaminated water conditions. The sensor was tested in a water tank for quantification of the limit of detections. The Φ51 × 51 mm2 YAlO3(Ce) crystal exhibits a nearly perfect proportionality with a correlation of over 0.999 in terms of light yield per energy and possesses a high energy resolution. The chemically stable CNT/PEEK window material further enhances the detection efficiency by minimizing the background counts from penetrating gamma-rays. Data timeliness was obtained for regulation-based minimum detectable activity targets within 300 s. For a source-detector distance of up to 300 mm in water, the gross counts demonstrate the existence of radionuclides (Cs-137 and Co-60), owing to their higher efficiency (max. ~15 times) than those of the photopeak counts. Such differences between efficiency values are more likely in water than in air because of the high density of water, resulting in an increased build-up of scattered photons. The proposed sensor is suitable for autonomous underwater systems.
Open AccessGamma-Ray Sensor Using YAlO3(Ce) Single Crystal and CNT/PEEK with High Sensitivity and Stability under Harsh Underwater Conditions
A new gamma-ray sensor, which could be employed in harsh underwater conditions, was developed using YAlO3(Ce) single crystal and carbon nanotube reinforced polyetheretherketone (CNT/PEEK). The sensor is compact, highly sensitive and stable, by providing real-time gross counts and an accumulated spectrum for fresh, saline, or contaminated water conditions. The sensor was tested in a water tank for quantification of the limit of detections. The Φ51 × 51 mm2 YAlO3(Ce) crystal exhibits a nearly perfect proportionality with a correlation of over 0.999 in terms of light yield per energy and possesses a high energy resolution. The chemically stable CNT/PEEK window material further enhances the detection efficiency by minimizing the background counts from penetrating gamma-rays. Data timeliness was obtained for regulation-based minimum detectable activity targets within 300 s. For a source-detector distance of up to 300 mm in water, the gross counts demonstrate the existence of radionuclides (Cs-137 and Co-60), owing to their higher efficiency (max. ~15 times) than those of the photopeak counts. Such differences between efficiency values are more likely in water than in air because of the high density of water, resulting in an increased build-up of scattered photons. The proposed sensor is suitable for autonomous underwater systems.
- 1 August 2019
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 204, 76-85
Optimizing UAV-based radiation sensor systems for aerial surveys
- 1 August 2019
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 204, 76-85
Optimizing UAV-based radiation sensor systems for aerial surveys
- 7 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (19) , 8920-8928
Conceptual Development of Sensing Module Applied to Autonomous Radiation Monitoring System for Marine Environment
We conceptually develop a scintillation-based sensing module for marine gamma-radiation monitoring deployed in an autonomous underwater glider to provide rapid responses to radiological emergencies. We first replace the forward section of the glider with a robust YAlO3:Ce scintillator, and we analyze several streamlined scintillator configurations with different geometries via simulations of the mechanical and sensing performances. We calculate the minimum thickness required for the scintillator to remain operationally stable in deep ocean water for hemispherical and conical scintillator shapes. Next, we study the advantages and disadvantages of each shape in terms of the drag force and detection efficiency. After the background-radiation estimation of seawater, we calculate the minimum detectable activity (MDA) according to the counting time, which is a key factor in system operation. We find that all configurations can detect 137Cs within 30 min even at distances >600 km from a high-level-nuclear-accident site. Even in relatively minor instances, dozens of hours are sufficient for the optimized sensing module to satisfy a given MDA goal for 137Cs. Our results indicate that radioactivity data can be effectively mapped in 3D by autonomous motion of a monitoring system with the proposed sensing module.
- 7 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (19) , 8920-8928
Conceptual Development of Sensing Module Applied to Autonomous Radiation Monitoring System for Marine Environment
We conceptually develop a scintillation-based sensing module for marine gamma-radiation monitoring deployed in an autonomous underwater glider to provide rapid responses to radiological emergencies. We first replace the forward section of the glider with a robust YAlO3:Ce scintillator, and we analyze several streamlined scintillator configurations with different geometries via simulations of the mechanical and sensing performances. We calculate the minimum thickness required for the scintillator to remain operationally stable in deep ocean water for hemispherical and conical scintillator shapes. Next, we study the advantages and disadvantages of each shape in terms of the drag force and detection efficiency. After the background-radiation estimation of seawater, we calculate the minimum detectable activity (MDA) according to the counting time, which is a key factor in system operation. We find that all configurations can detect 137Cs within 30 min even at distances >600 km from a high-level-nuclear-accident site. Even in relatively minor instances, dozens of hours are sufficient for the optimized sensing module to satisfy a given MDA goal for 137Cs. Our results indicate that radioactivity data can be effectively mapped in 3D by autonomous motion of a monitoring system with the proposed sensing module.