Alistair Boyle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alistair Boyle has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Andy Adler
Carleton University
5 shared publications Andy Adler
3 shared publications- Nolwenn Lesparre
Institut Terre et Environnement de Strasbourg, University of Strasbourg/EOST/ENGEES, CNRS, UMR7063, Strasbourg, France
2 shared publications - William R. B. Lionheart
University of Manchester - The Victoria University of Manchester Campus
2 shared publications A Adler
1 shared publicationA. Adler
1 shared publication
Latest Publications
- Open Access
- 26 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 36444-36454
Development and Validation of a Deep Learning Algorithm and Open-Source Platform for the Automatic Labelling of Motion Capture Markers
The purpose of this work was to develop an open-source deep learning-based algorithm for motion capture marker labelling that can be trained on measured or simulated marker trajectories. In the proposed algorithm, a deep neural network including recurrent layers is trained on measured or simulated marker trajectories. Labels are assigned to markers using the Hungarian algorithm and a predefined generic marker set is used to identify and correct mislabeled markers. The algorithm was first trained and tested on measured motion capture data. Then, the algorithm was trained on simulated trajectories and tested on data that included movements not contained in the simulated data set. The ability to improve accuracy using transfer learning to update the neural network weights based on labelled motion capture data was assessed. The effect of occluded and extraneous markers on labelling accuracy was also examined. Labelling accuracy was 99.6% when trained on measured data and 92.8% when trained on simulated trajectories, but could be improved to up to 98.8% through transfer learning. Missing or extraneous markers reduced labelling accuracy, but results were comparable to commercial software. The proposed labelling algorithm can be used to accurately label motion capture data in the presence of missing and extraneous markers and accuracy can be improved as data are collected, labelled, and added to the training set. The algorithm and user interface can reduce the time and manual effort required to label optical motion capture data, particularly for those with limited access to commercial software.
- 26 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 36444-36454
Open AccessDevelopment and Validation of a Deep Learning Algorithm and Open-Source Platform for the Automatic Labelling of Motion Capture Markers
The purpose of this work was to develop an open-source deep learning-based algorithm for motion capture marker labelling that can be trained on measured or simulated marker trajectories. In the proposed algorithm, a deep neural network including recurrent layers is trained on measured or simulated marker trajectories. Labels are assigned to markers using the Hungarian algorithm and a predefined generic marker set is used to identify and correct mislabeled markers. The algorithm was first trained and tested on measured motion capture data. Then, the algorithm was trained on simulated trajectories and tested on data that included movements not contained in the simulated data set. The ability to improve accuracy using transfer learning to update the neural network weights based on labelled motion capture data was assessed. The effect of occluded and extraneous markers on labelling accuracy was also examined. Labelling accuracy was 99.6% when trained on measured data and 92.8% when trained on simulated trajectories, but could be improved to up to 98.8% through transfer learning. Missing or extraneous markers reduced labelling accuracy, but results were comparable to commercial software. The proposed labelling algorithm can be used to accurately label motion capture data in the presence of missing and extraneous markers and accuracy can be improved as data are collected, labelled, and added to the training set. The algorithm and user interface can reduce the time and manual effort required to label optical motion capture data, particularly for those with limited access to commercial software.
- 1 June 2020
- Published by IOP Publishing in Physiological Measurement
- Vol. 41 (6) , 064003
Beneficial techniques for spatio-temporal imaging in electrical impedance tomography
Objective : Electrical impedance tomography (EIT) typically reconstructs individual images from electrical voltage measurements at pairs of electrodes due to current driven through other electrode pairs on a body. EIT images have low spatial resolution, but excellent temporal resolution. There are four methods for integrating temporal data into an EIT reconstruction: filtering over measurements, filtering over images, combined spatial and temporal (spatio-temporal) regularization, and Kalman filtering. These spatio-temporal methods have not been directly compared, making it difficult to evaluate relative performance and choose an appropriate method for particular use cases. Approach : We (i) develop a common framework, (ii) develop comparison metrics, (iii) perform simulation and tank studies which directly compare algorithms, and (iv) report on relative advantages of the different algorithms. Main results : Temporal filtering is well understood, but often not considered as part of the imaging process despite a direct impact on image reconstruction quality. Spatio-temporal regularized techniques are not yet efficient but offer tantalizing advantages. Kalman filtering enables adaptive filtering for time-varying measurement/image noise at the cost of often over-regularized (sub-optimal) images which can now be understood in the same framework as the other techniques. Further research into efficient implementations of Gauss–Newton spatio-temporal regularization will allow temporal and spatial covariance to be explicitly defined for longer time series ( n > 10 frames) where temporal regularization can be more effective. For the immediate analysis of temporally varying images, we recommend the use of adaptive (time-varying) temporal filtering of measurements followed by adaptive spatial regularization (hyperparameter selection) as the most computationally efficient and effective approach currently available. Significance : The analysis of variation within regions of an EIT image to extract physiological measures (functional imaging), has become an important EIT technique where temporal and spatial aspects of analysis are tightly integrated. This work gives guidance on available methods and suggests directions for future research.
- 1 June 2020
- Published by IOP Publishing in Physiological Measurement
- Vol. 41 (6) , 064003
Beneficial techniques for spatio-temporal imaging in electrical impedance tomography
Objective : Electrical impedance tomography (EIT) typically reconstructs individual images from electrical voltage measurements at pairs of electrodes due to current driven through other electrode pairs on a body. EIT images have low spatial resolution, but excellent temporal resolution. There are four methods for integrating temporal data into an EIT reconstruction: filtering over measurements, filtering over images, combined spatial and temporal (spatio-temporal) regularization, and Kalman filtering. These spatio-temporal methods have not been directly compared, making it difficult to evaluate relative performance and choose an appropriate method for particular use cases. Approach : We (i) develop a common framework, (ii) develop comparison metrics, (iii) perform simulation and tank studies which directly compare algorithms, and (iv) report on relative advantages of the different algorithms. Main results : Temporal filtering is well understood, but often not considered as part of the imaging process despite a direct impact on image reconstruction quality. Spatio-temporal regularized techniques are not yet efficient but offer tantalizing advantages. Kalman filtering enables adaptive filtering for time-varying measurement/image noise at the cost of often over-regularized (sub-optimal) images which can now be understood in the same framework as the other techniques. Further research into efficient implementations of Gauss–Newton spatio-temporal regularization will allow temporal and spatial covariance to be explicitly defined for longer time series ( n > 10 frames) where temporal regularization can be more effective. For the immediate analysis of temporally varying images, we recommend the use of adaptive (time-varying) temporal filtering of measurements followed by adaptive spatial regularization (hyperparameter selection) as the most computationally efficient and effective approach currently available. Significance : The analysis of variation within regions of an EIT image to extract physiological measures (functional imaging), has become an important EIT technique where temporal and spatial aspects of analysis are tightly integrated. This work gives guidance on available methods and suggests directions for future research.
- 1 May 2019
- Published by IOP Publishing in Physiological Measurement
- Vol. 40 (5) , 054002
Comparison of bolus- and filtering-based EIT measures of lung perfusion in an animal model
Objective : Two main functional imaging approaches have been used to measure regional lung perfusion using electrical impedance tomography (EIT): venous injection of a hypertonic saline contrast agent and imaging of its passage through the heart and lungs, and digital filtering of heart-frequency impedance changes over sequences of EIT images. This paper systematically compares filtering-based perfusion estimates and bolus injection methods to determine to which degree they are related. Approach : EIT data was recorded on seven mechanically ventilated newborn lambs in which ventilation distribution was varied through changes in posture between prone, supine, left- and right-lateral positions. Perfusion images were calculated using frequency filtering and ensemble averaging during both ventilation and apnoea time segments for each posture to compare against contrast agent-based methods using Jaccard distance score. Main results : Using bolus-based EIT measures of lung perfusion as the reference frequency filtering techniques performed better than ensemble averaging and both techniques performed equally well across apnoea and ventilation data segments. Significance : Our results indicate the potential for use of filtering-based EIT measures of heart-frequency activity as a non-invasive proxy for contrast agent injection-based measures of lung perfusion.
- 1 May 2019
- Published by IOP Publishing in Physiological Measurement
- Vol. 40 (5) , 054002
Comparison of bolus- and filtering-based EIT measures of lung perfusion in an animal model
Objective : Two main functional imaging approaches have been used to measure regional lung perfusion using electrical impedance tomography (EIT): venous injection of a hypertonic saline contrast agent and imaging of its passage through the heart and lungs, and digital filtering of heart-frequency impedance changes over sequences of EIT images. This paper systematically compares filtering-based perfusion estimates and bolus injection methods to determine to which degree they are related. Approach : EIT data was recorded on seven mechanically ventilated newborn lambs in which ventilation distribution was varied through changes in posture between prone, supine, left- and right-lateral positions. Perfusion images were calculated using frequency filtering and ensemble averaging during both ventilation and apnoea time segments for each posture to compare against contrast agent-based methods using Jaccard distance score. Main results : Using bolus-based EIT measures of lung perfusion as the reference frequency filtering techniques performed better than ensemble averaging and both techniques performed equally well across apnoea and ventilation data segments. Significance : Our results indicate the potential for use of filtering-based EIT measures of heart-frequency activity as a non-invasive proxy for contrast agent injection-based measures of lung perfusion.
- 1 January 2019
- Published by Elsevier in Geothermics
- Vol. 77, 368-382
4D electrical resistivity tomography (ERT) for aquifer thermal energy storage monitoring
- 1 January 2019
- Published by Elsevier in Geothermics
- Vol. 77, 368-382
4D electrical resistivity tomography (ERT) for aquifer thermal energy storage monitoring
- Open Access
- 23 October 2017
- Published by Oxford University Press (OUP) in Geophysical Journal International
- Vol. 212 (2) , 1167-1182
Jointly reconstructing ground motion and resistivity for ERT-based slope stability monitoring
Electrical resistivity tomography (ERT) is increasingly being used to investigate unstable slopes and monitor the hydrogeological processes within. But movement of electrodes or incorrect placement of electrodes with respect to an assumed model can introduce significant resistivity artefacts into the reconstruction. In this work, we demonstrate a joint resistivity and electrode movement reconstruction algorithm within an iterative Gauss–Newton framework. We apply this to ERT monitoring data from an active slow-moving landslide in the UK. Results show fewer resistivity artefacts and suggest that electrode movement and resistivity can be reconstructed at the same time under certain conditions. A new 2.5-D formulation for the electrode position Jacobian is developed and is shown to give accurate numerical solutions when compared to the adjoint method on 3-D models. On large finite element meshes, the calculation time of the newly developed approach was also proven to be orders of magnitude faster than the 3-D adjoint method and addressed modelling errors in the 2-D perturbation and adjoint electrode position Jacobian.
- 23 October 2017
- Published by Oxford University Press (OUP) in Geophysical Journal International
- Vol. 212 (2) , 1167-1182
Open AccessJointly reconstructing ground motion and resistivity for ERT-based slope stability monitoring
Electrical resistivity tomography (ERT) is increasingly being used to investigate unstable slopes and monitor the hydrogeological processes within. But movement of electrodes or incorrect placement of electrodes with respect to an assumed model can introduce significant resistivity artefacts into the reconstruction. In this work, we demonstrate a joint resistivity and electrode movement reconstruction algorithm within an iterative Gauss–Newton framework. We apply this to ERT monitoring data from an active slow-moving landslide in the UK. Results show fewer resistivity artefacts and suggest that electrode movement and resistivity can be reconstructed at the same time under certain conditions. A new 2.5-D formulation for the electrode position Jacobian is developed and is shown to give accurate numerical solutions when compared to the adjoint method on 3-D models. On large finite element meshes, the calculation time of the newly developed approach was also proven to be orders of magnitude faster than the 3-D adjoint method and addressed modelling errors in the 2-D perturbation and adjoint electrode position Jacobian.
- Top Cited Papers
- 17 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 64 (11) , 2494-2504
Electrical Impedance Tomography: Tissue Properties to Image Measures
Electrical impedance tomography (EIT) uses electrical stimulation and measurement at the body surface to image the electrical properties of internal tissues. It has the advantage of noninvasiveness and high temporal resolution but suffers from poor spatial resolution and sensitivity to electrode movement and contact quality. EIT can be useful to applications, where there are conductive contrasts between tissues, fluids, or gasses, such as imaging of cancerous or ischemic tissue or functional monitoring of breathing, blood flow, gastric motility, and neural activity. The past decade has seen clinical application and commercial activity using EIT for ventilation monitoring. Interpretation of EIT-based measures is complex, and this review paper focuses on describing the image interpretation “pathway.” We review this pathway, from Tissue Electrical Properties, EIT Electrodes & Hardware, Sensitivity, Image Reconstruction, Image Processing to EIT Measures. The relationship is discussed between the clinically relevant parameters and the reconstructed properties. An overview is given of areas of EIT application and of our perspectives for research and development.
- 17 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 64 (11) , 2494-2504
Top Cited PapersElectrical Impedance Tomography: Tissue Properties to Image Measures
Electrical impedance tomography (EIT) uses electrical stimulation and measurement at the body surface to image the electrical properties of internal tissues. It has the advantage of noninvasiveness and high temporal resolution but suffers from poor spatial resolution and sensitivity to electrode movement and contact quality. EIT can be useful to applications, where there are conductive contrasts between tissues, fluids, or gasses, such as imaging of cancerous or ischemic tissue or functional monitoring of breathing, blood flow, gastric motility, and neural activity. The past decade has seen clinical application and commercial activity using EIT for ventilation monitoring. Interpretation of EIT-based measures is complex, and this review paper focuses on describing the image interpretation “pathway.” We review this pathway, from Tissue Electrical Properties, EIT Electrodes & Hardware, Sensitivity, Image Reconstruction, Image Processing to EIT Measures. The relationship is discussed between the clinically relevant parameters and the reconstructed properties. An overview is given of areas of EIT application and of our perspectives for research and development.
- Open Access
- 16 February 2017
- Published by IOP Publishing in Physiological Measurement
- Vol. 38 (3) , 555-574
Methods for calculating the electrode position Jacobian for impedance imaging
Electrical impedance tomography (EIT) or electrical resistivity tomography (ERT) current and measure voltages at the boundary of a domain through electrodes. The movement or incorrect placement of electrodes may lead to modelling errors that result in significant reconstructed image artifacts. These errors may be accounted for by allowing for electrode position estimates in the model. Movement may be reconstructed through a first-order approximation, the electrode position Jacobian. A reconstruction that incorporates electrode position estimates and conductivity can significantly reduce image artifacts. Conversely, if electrode position is ignored it can be difficult to distinguish true conductivity changes from reconstruction artifacts which may increase the risk of a flawed interpretation. In this work, we aim to determine the fastest, most accurate approach for estimating the electrode position Jacobian. Four methods of calculating the electrode position Jacobian were evaluated on a homogeneous halfspace. Results show that Fréchet derivative and rank-one update methods are competitive in computational efficiency but achieve different solutions for certain values of contact impedance and mesh density.
- 16 February 2017
- Published by IOP Publishing in Physiological Measurement
- Vol. 38 (3) , 555-574
Open AccessMethods for calculating the electrode position Jacobian for impedance imaging
Electrical impedance tomography (EIT) or electrical resistivity tomography (ERT) current and measure voltages at the boundary of a domain through electrodes. The movement or incorrect placement of electrodes may lead to modelling errors that result in significant reconstructed image artifacts. These errors may be accounted for by allowing for electrode position estimates in the model. Movement may be reconstructed through a first-order approximation, the electrode position Jacobian. A reconstruction that incorporates electrode position estimates and conductivity can significantly reduce image artifacts. Conversely, if electrode position is ignored it can be difficult to distinguish true conductivity changes from reconstruction artifacts which may increase the risk of a flawed interpretation. In this work, we aim to determine the fastest, most accurate approach for estimating the electrode position Jacobian. Four methods of calculating the electrode position Jacobian were evaluated on a homogeneous halfspace. Results show that Fréchet derivative and rank-one update methods are competitive in computational efficiency but achieve different solutions for certain values of contact impedance and mesh density.
- 1 May 2016
- Published by Elsevier in Journal of Applied Geophysics
- Vol. 128, 163-178
Electrical resistivity imaging in transmission between surface and underground tunnel for fault characterization
- 1 May 2016
- Published by Elsevier in Journal of Applied Geophysics
- Vol. 128, 163-178
Electrical resistivity imaging in transmission between surface and underground tunnel for fault characterization
- 12 June 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 31 (12) , 2185-2193
Shape Deformation in Two-Dimensional Electrical Impedance Tomography
Electrical impedance tomography (EIT) uses measurements from surface electrodes to reconstruct an image of the conductivity of the contained medium. However, changes in measurements result from both changes in internal conductivity and changes in the shape of the medium relative to the electrode positions. Failure to account for shape changes results in a conductivity image with significant artifacts. Previous work to address shape changes in EIT has shown that in some cases boundary shape and electrode location can be uniquely determined for isotropic conductivities; however, for geometrically conformal changes, this is not possible. This prior work has shown that the shape change problem can be partially addressed. In this paper, we explore the limits of compensation for boundary movement in EIT using three approaches. First, a theoretical model was developed to separate a deformation vector field into conformal and non-conformal components, from which the reconstruction limits may be determined. Next, finite element models were used to simulate EIT measurements from a domain whose boundary has been deformed. Finally, an experimental phantom was constructed from which boundary deformation measurements were acquired. Results, both in simulation and with experimental data, suggest that some electrode movement and boundary distortions can be reconstructed based on conductivity changes alone while reducing image artifacts in the process.
- 12 June 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 31 (12) , 2185-2193
Shape Deformation in Two-Dimensional Electrical Impedance Tomography
Electrical impedance tomography (EIT) uses measurements from surface electrodes to reconstruct an image of the conductivity of the contained medium. However, changes in measurements result from both changes in internal conductivity and changes in the shape of the medium relative to the electrode positions. Failure to account for shape changes results in a conductivity image with significant artifacts. Previous work to address shape changes in EIT has shown that in some cases boundary shape and electrode location can be uniquely determined for isotropic conductivities; however, for geometrically conformal changes, this is not possible. This prior work has shown that the shape change problem can be partially addressed. In this paper, we explore the limits of compensation for boundary movement in EIT using three approaches. First, a theoretical model was developed to separate a deformation vector field into conformal and non-conformal components, from which the reconstruction limits may be determined. Next, finite element models were used to simulate EIT measurements from a domain whose boundary has been deformed. Finally, an experimental phantom was constructed from which boundary deformation measurements were acquired. Results, both in simulation and with experimental data, suggest that some electrode movement and boundary distortions can be reconstructed based on conductivity changes alone while reducing image artifacts in the process.