Suvajyoti Guha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Suvajyoti Guha has a total of 129 co-authors. Here are the top co-authors by number of shared publications:
Michael R. Zachariah
13 shared publicationsMatthew R. Myers
Office of Science and Engineering Laboratories Center for Devices and Radiological Health Silver Spring Maryland USA
10 shared publicationsMichael J. Tarlov
9 shared publicationsMingdong Li
6 shared publications- Alexander Herman
Office of Science and Engineering Laboratories Center for Devices and Radiological Health Silver Spring Maryland USA
5 shared publications Daniel Porter
Division of Applied Mechanics, Office of Science and Engineering Laboratories, U.S. Food and Drug Administration, Silver Spring, Maryland, United States of America
5 shared publications
Latest Publications
- 22 August 2025
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 140 (3-4) , 1427-1440
Leak verification method for additively manufactured medical devices
- 22 August 2025
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 140 (3-4) , 1427-1440
Leak verification method for additively manufactured medical devices
- Open Access
- 22 January 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (2) , 124
Development of a Tool for Verifying Leakage Detection in Microfluidic Systems
While submissions of microfluidic-based medical devices to the Food and Drug Administration (FDA) have increased in recent years, leakage remains a common but difficult failure mode to detect in microfluidic systems. Here, we have developed a sensitive tool to measure and verify leakages ranging from 0.1% to 10% in leakage detection systems, which can then be used to detect leak in microfluidic devices. Our methodology includes an analytical model that applies hydrodynamic resistance using different fluid-contacting elements (e.g., tubing, junctions, and connectors) to tune the leakage rate based on the application-specific acceptance criteria. We then used three polymer-based microfluidic systems to target leakage rates of approximately 0.1, 1.0, and 10%. The experimental uncertainties in Polyether Ether Ketone (PEEK) tubing were 23.08%, 13.64%, and 1.16%, respectively, while the PEEK-Coated Fused Silica (PEEKsil) tubing system had errors of 0.00%, 0.72%, and 1.59%, respectively, relative to the theoretical values for the same target leak rates. The commonly used commercial grade Cyclic Olefin Copolymer (COC) microfluidic chips produced errors of 7.69% and 5.05%, respectively, for target leakage rates of 0.24% and 1.88%. We anticipate that the proposed bench test method can be useful for device developers as a verification tool for leakage detection systems before assessing flow-mediated leakage failure modes in microfluidic medical devices.
- 22 January 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (2) , 124
Open AccessDevelopment of a Tool for Verifying Leakage Detection in Microfluidic Systems
While submissions of microfluidic-based medical devices to the Food and Drug Administration (FDA) have increased in recent years, leakage remains a common but difficult failure mode to detect in microfluidic systems. Here, we have developed a sensitive tool to measure and verify leakages ranging from 0.1% to 10% in leakage detection systems, which can then be used to detect leak in microfluidic devices. Our methodology includes an analytical model that applies hydrodynamic resistance using different fluid-contacting elements (e.g., tubing, junctions, and connectors) to tune the leakage rate based on the application-specific acceptance criteria. We then used three polymer-based microfluidic systems to target leakage rates of approximately 0.1, 1.0, and 10%. The experimental uncertainties in Polyether Ether Ketone (PEEK) tubing were 23.08%, 13.64%, and 1.16%, respectively, while the PEEK-Coated Fused Silica (PEEKsil) tubing system had errors of 0.00%, 0.72%, and 1.59%, respectively, relative to the theoretical values for the same target leak rates. The commonly used commercial grade Cyclic Olefin Copolymer (COC) microfluidic chips produced errors of 7.69% and 5.05%, respectively, for target leakage rates of 0.24% and 1.88%. We anticipate that the proposed bench test method can be useful for device developers as a verification tool for leakage detection systems before assessing flow-mediated leakage failure modes in microfluidic medical devices.
- Open Access
- 19 September 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (9) , e0307879
A retrospective characterization of pediatric facemasks marketed in the United States and implications for future designs
Background: Device manufacturers who seek to market their pediatric facemasks in the United States (U.S.), as part of anthropometric data requirement, need to demonstrate their mask designs are expected to fit the intended user population. However, currently there are no well accepted test methodologies for pediatric facemasks. In addition, unlike N95 respirators, the expected maximum flow rate, and the pressure drop at that expected maximum flow rate for pediatric facemasks have not been established. Method: The objective of this article is three-fold; use a literature survey to determine the worst-case flow rate, and an acceptable breathing resistance; and come up with a bench-test based protocol for assessing fit of pediatric facemasks. Results & discussion: The worst-case breathing flow rate for mask testing in the pediatric population is 45–60 Liters/minute (LPM), and the acceptable pressure drop at the worst-case flow rate is 2.0 mmH2O. A retrospective assessment of all the four brands of legally marketed facemasks in the U.S. that could be purchased, revealed that majority of the brands have high filtration efficiency (>95%) at low flow rate 5 LPM which reduces to ~ 80% at 45 LPM. At 5 LPM, the pressure drop ranges from 0.3–0.6 mmH2O, remaining below the 2.0 mmH2O. However, at higher flow rates, (representing strenuous activities, or older children (> 12 years)), most masks exhibited a pressure drop within the range of 2.9 to 6.0 mmH2O. Furthermore, opening the pleats of the facemasks completely results in a notable reduction in pressure drop (a 6.6-fold decrease, p = 0.03). To assess fit of these same brands of facemasks, we then updated our previous validated adult manikin fit-test method and used it in manikins in the age group of 2 to 14 years. Either poor nose-clip adherence to the manikin, low filtration efficiency of the pediatric facemasks, or off-label use (i.e. when donned on manikins representing 2 years to 14 years) contributed to low fit. Conclusions: A new bench-top tool to evaluate quantitative fit of pediatric facemasks was developed. In addition, based on the research reported here, we provide practical implications for the members of the community: users, academia and medical device manufacturers.
- 19 September 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (9) , e0307879
Open AccessA retrospective characterization of pediatric facemasks marketed in the United States and implications for future designs
Background: Device manufacturers who seek to market their pediatric facemasks in the United States (U.S.), as part of anthropometric data requirement, need to demonstrate their mask designs are expected to fit the intended user population. However, currently there are no well accepted test methodologies for pediatric facemasks. In addition, unlike N95 respirators, the expected maximum flow rate, and the pressure drop at that expected maximum flow rate for pediatric facemasks have not been established. Method: The objective of this article is three-fold; use a literature survey to determine the worst-case flow rate, and an acceptable breathing resistance; and come up with a bench-test based protocol for assessing fit of pediatric facemasks. Results & discussion: The worst-case breathing flow rate for mask testing in the pediatric population is 45–60 Liters/minute (LPM), and the acceptable pressure drop at the worst-case flow rate is 2.0 mmH2O. A retrospective assessment of all the four brands of legally marketed facemasks in the U.S. that could be purchased, revealed that majority of the brands have high filtration efficiency (>95%) at low flow rate 5 LPM which reduces to ~ 80% at 45 LPM. At 5 LPM, the pressure drop ranges from 0.3–0.6 mmH2O, remaining below the 2.0 mmH2O. However, at higher flow rates, (representing strenuous activities, or older children (> 12 years)), most masks exhibited a pressure drop within the range of 2.9 to 6.0 mmH2O. Furthermore, opening the pleats of the facemasks completely results in a notable reduction in pressure drop (a 6.6-fold decrease, p = 0.03). To assess fit of these same brands of facemasks, we then updated our previous validated adult manikin fit-test method and used it in manikins in the age group of 2 to 14 years. Either poor nose-clip adherence to the manikin, low filtration efficiency of the pediatric facemasks, or off-label use (i.e. when donned on manikins representing 2 years to 14 years) contributed to low fit. Conclusions: A new bench-top tool to evaluate quantitative fit of pediatric facemasks was developed. In addition, based on the research reported here, we provide practical implications for the members of the community: users, academia and medical device manufacturers.
- Top Cited PapersOpen Access
- 5 March 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (7) , 1867-1874
Next generation microfluidics: fulfilling the promise of lab-on-a-chip technologies
In this perspective article, we present the state of the microfluidic field regarding current limitations and propose future directions and new approaches for the field to advance lab-on-a-chip technologies closer to translation and clinical use.
- 5 March 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (7) , 1867-1874
Top Cited PapersOpen AccessNext generation microfluidics: fulfilling the promise of lab-on-a-chip technologies
In this perspective article, we present the state of the microfluidic field regarding current limitations and propose future directions and new approaches for the field to advance lab-on-a-chip technologies closer to translation and clinical use.
- Open Access
- 24 June 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (7) , 1293
A Systematic Analysis of Recent Technology Trends of Microfluidic Medical Devices in the United States
In recent years, the U.S. Food and Drug Administration (FDA) has seen an increase in microfluidic medical device submissions, likely stemming from recent advancements in microfluidic technologies. This recent trend has only been enhanced during the COVID-19 pandemic, as microfluidic-based test kits have been used for diagnosis. To better understand the implications of this emerging technology, device submissions to the FDA from 2015 to 2021 containing microfluidic technologies have been systematically reviewed to identify trends in microfluidic medical applications, performance tests, standards used, fabrication techniques, materials, and flow systems. More than 80% of devices with microfluidic platforms were found to be diagnostic in nature, with lateral flow systems accounting for about 35% of all identified microfluidic devices. A targeted analysis of over 40,000 adverse event reports linked to microfluidic technologies revealed that flow, operation, and data output related failures are the most common failure modes for these device types. Lastly, this paper highlights key considerations for developing new protocols for various microfluidic applications that use certain analytes (e.g., blood, urine, nasal-pharyngeal swab), materials, flow, and detection mechanisms. We anticipate that these considerations would help facilitate innovation in microfluidic-based medical devices.
- 24 June 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (7) , 1293
Open AccessA Systematic Analysis of Recent Technology Trends of Microfluidic Medical Devices in the United States
In recent years, the U.S. Food and Drug Administration (FDA) has seen an increase in microfluidic medical device submissions, likely stemming from recent advancements in microfluidic technologies. This recent trend has only been enhanced during the COVID-19 pandemic, as microfluidic-based test kits have been used for diagnosis. To better understand the implications of this emerging technology, device submissions to the FDA from 2015 to 2021 containing microfluidic technologies have been systematically reviewed to identify trends in microfluidic medical applications, performance tests, standards used, fabrication techniques, materials, and flow systems. More than 80% of devices with microfluidic platforms were found to be diagnostic in nature, with lateral flow systems accounting for about 35% of all identified microfluidic devices. A targeted analysis of over 40,000 adverse event reports linked to microfluidic technologies revealed that flow, operation, and data output related failures are the most common failure modes for these device types. Lastly, this paper highlights key considerations for developing new protocols for various microfluidic applications that use certain analytes (e.g., blood, urine, nasal-pharyngeal swab), materials, flow, and detection mechanisms. We anticipate that these considerations would help facilitate innovation in microfluidic-based medical devices.
- Open Access
- 28 February 2023
- Published by Elsevier in Additive Manufacturing
- Vol. 67, 103468
Benchtop assessment of sealing efficacy and breathability of additively manufactured (AM) face masks
- 28 February 2023
- Published by Elsevier in Additive Manufacturing
- Vol. 67, 103468
Open AccessBenchtop assessment of sealing efficacy and breathability of additively manufactured (AM) face masks
- Open Access
- 1 January 2023
- Published by International Society for Respiratory Protection in Journal of the International Society for Respiratory Protection
- Vol. 40 (2) , 1-14
Modifying NIOSH’s Manikin Fit Evaluation Method to Match Fit Testing With Human Subjects
A manikin fit test method developed by the Center for Disease Control and Prevention’s (CDC) National Institute of Occupational Safety and Health (NIOSH) has been proposed as an alternative to fit testing with human subjects. The advantages of a manikin fit test method over actual fit testing are that it does not require human subjects which can be resource intensive, and hence easier to implement. At the beginning of coronavirus 2019 (COVID-19) pandemic, although early studies showed that manikin fit can be maintained after several decontamination cycles, real world evidence obtained using human subjects revealed that the N95 respirators failed only after a few decontamination cycles. The goal of this article was to make modifications to the NIOSH’s manikin fit-test method so it can mimic real world performance of N95 respirators better. After making modifications to this method, we then investigated the effect of longterm wear after donning of the respirators, repeated donning and doffing, as well as decontamination methods (i.e. autoclaving and microwave generated steam) on the fit factor. Averaging the overall manikin fit factor across all scenarios, our modified method overpredicted overall fit factor by only 7 % and 14 % compared to adult human subjects using a breathing routine that included simulated heavy breathing rates of 85, and 70 Liters/minute, respectively. In addition, a constant flow produced similar results as cyclic flow using a breathing simulator. The modified test method also offered the following additional insights into reuse of respirators during future pandemics – when reused within a single work shift, more than 5 donnings should be avoided; and microwave generated steam may be a more viable option for decontaminating N95 respirators compared to autoclaving for a single decontamination cycle.
- 1 January 2023
- Published by International Society for Respiratory Protection in Journal of the International Society for Respiratory Protection
- Vol. 40 (2) , 1-14
Open AccessModifying NIOSH’s Manikin Fit Evaluation Method to Match Fit Testing With Human Subjects
A manikin fit test method developed by the Center for Disease Control and Prevention’s (CDC) National Institute of Occupational Safety and Health (NIOSH) has been proposed as an alternative to fit testing with human subjects. The advantages of a manikin fit test method over actual fit testing are that it does not require human subjects which can be resource intensive, and hence easier to implement. At the beginning of coronavirus 2019 (COVID-19) pandemic, although early studies showed that manikin fit can be maintained after several decontamination cycles, real world evidence obtained using human subjects revealed that the N95 respirators failed only after a few decontamination cycles. The goal of this article was to make modifications to the NIOSH’s manikin fit-test method so it can mimic real world performance of N95 respirators better. After making modifications to this method, we then investigated the effect of longterm wear after donning of the respirators, repeated donning and doffing, as well as decontamination methods (i.e. autoclaving and microwave generated steam) on the fit factor. Averaging the overall manikin fit factor across all scenarios, our modified method overpredicted overall fit factor by only 7 % and 14 % compared to adult human subjects using a breathing routine that included simulated heavy breathing rates of 85, and 70 Liters/minute, respectively. In addition, a constant flow produced similar results as cyclic flow using a breathing simulator. The modified test method also offered the following additional insights into reuse of respirators during future pandemics – when reused within a single work shift, more than 5 donnings should be avoided; and microwave generated steam may be a more viable option for decontaminating N95 respirators compared to autoclaving for a single decontamination cycle.
- Open Access
- 20 December 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (12) , e0279309
Characterization of aerosols generated by high-power electronic nicotine delivery systems (ENDS): Influence of atomizer, temperature and PG:VG ratios
The aerosol characteristics of electronic nicotine delivery systems (ENDS) are important parameters in predicting health outcomes since parameters such as aerosol particle size correlate strongly to aerosol delivery and deposition efficiency. However, many studies to date do not account for aerosol aging, which may affect the measurement of ultra-fine particles that typically coagulate or agglomerate during puff development. To reduce aerosol aging, we herein present a unique instrumentation method that combines a) positive pressure ENDS activation and sample collection, b) minimization of both sample tubing length and dilution factors, and c) a high-resolution, electrical low-pressure impactor. This novel approach was applied to systematically investigate the effects of coil design, coil temperature, and propylene glycol to vegetable glycerol ratios on aerosol characteristics including aerosol mass generation, aerosol count generation, and the mass and count size distributions for a high-powered ENDS. Aerosol count measurements revealed high concentrations of ultra-fine particles compared to fine and coarse particles at 200°C, while aerosol mass measurements showed an increase in the overall aerosol mass of fine and coarse particles with increases in temperature and decreases in propylene glycol content. These results provide a better understanding on how various ENDS design parameters affect aerosol characteristics and highlight the need for further research to identify the design parameters that most impact ultra-fine particle generation.
- 20 December 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (12) , e0279309
Open AccessCharacterization of aerosols generated by high-power electronic nicotine delivery systems (ENDS): Influence of atomizer, temperature and PG:VG ratios
The aerosol characteristics of electronic nicotine delivery systems (ENDS) are important parameters in predicting health outcomes since parameters such as aerosol particle size correlate strongly to aerosol delivery and deposition efficiency. However, many studies to date do not account for aerosol aging, which may affect the measurement of ultra-fine particles that typically coagulate or agglomerate during puff development. To reduce aerosol aging, we herein present a unique instrumentation method that combines a) positive pressure ENDS activation and sample collection, b) minimization of both sample tubing length and dilution factors, and c) a high-resolution, electrical low-pressure impactor. This novel approach was applied to systematically investigate the effects of coil design, coil temperature, and propylene glycol to vegetable glycerol ratios on aerosol characteristics including aerosol mass generation, aerosol count generation, and the mass and count size distributions for a high-powered ENDS. Aerosol count measurements revealed high concentrations of ultra-fine particles compared to fine and coarse particles at 200°C, while aerosol mass measurements showed an increase in the overall aerosol mass of fine and coarse particles with increases in temperature and decreases in propylene glycol content. These results provide a better understanding on how various ENDS design parameters affect aerosol characteristics and highlight the need for further research to identify the design parameters that most impact ultra-fine particle generation.
- Open Access
- 27 June 2022
- Published by Frontiers Media SA in Frontiers in Water
- Vol. 4
A Methodology for Investigating Aerosolization of Nontuberculous Mycobacteria From Contaminated Heater Cooler Devices
Aerosols inadvertently generated by the bubbling of contaminated water in heater cooler devices (HCDs) have been associated with hundreds of patient infections. These aerosols are typically generated by bubbling within the water tanks of HCDs that subsequently escape from the device leading to contamination of the operating room and potentially infect patients undergoing cardiothoracic surgery. Although these infections are now well-reported in literature, very little research has been done to understand the influence of bubbling frequencies, differences in aerosolization across various species of bacteria, sampling methodologies, infectious dose, etc. Here we report on the development of a miniaturized bubbler with a footprint much smaller than HCDs, that will enable academic researchers and HCD developers to investigate these parameters. Using this bubbler, we found that the aerosolization potential of slow growingMycobacterium chimaerais about one hundred-fold more (p< 0.05) compared to rapid growingM. smegmatisfor low inoculum concentrations (≤106CFU/mL), underscoring the need for using clinically relevantM. chimaerafor evaluating the aerosolization potential of nontuberculous mycobacteria (NTM) from HCDs.
- 27 June 2022
- Published by Frontiers Media SA in Frontiers in Water
- Vol. 4
Open AccessA Methodology for Investigating Aerosolization of Nontuberculous Mycobacteria From Contaminated Heater Cooler Devices
Aerosols inadvertently generated by the bubbling of contaminated water in heater cooler devices (HCDs) have been associated with hundreds of patient infections. These aerosols are typically generated by bubbling within the water tanks of HCDs that subsequently escape from the device leading to contamination of the operating room and potentially infect patients undergoing cardiothoracic surgery. Although these infections are now well-reported in literature, very little research has been done to understand the influence of bubbling frequencies, differences in aerosolization across various species of bacteria, sampling methodologies, infectious dose, etc. Here we report on the development of a miniaturized bubbler with a footprint much smaller than HCDs, that will enable academic researchers and HCD developers to investigate these parameters. Using this bubbler, we found that the aerosolization potential of slow growingMycobacterium chimaerais about one hundred-fold more (p< 0.05) compared to rapid growingM. smegmatisfor low inoculum concentrations (≤106CFU/mL), underscoring the need for using clinically relevantM. chimaerafor evaluating the aerosolization potential of nontuberculous mycobacteria (NTM) from HCDs.
- 1 May 2022
- Published by AIP Publishing in Physics of Fluids
- Vol. 34 (5) , 053304
Particle–liquid transport in curved microchannels: Effect of particle volume fraction and size in Dean flow
Microfluidic transport in spiral channels is a promising flow-driven mechanism for applications such as cell sorting and particle focusing. Spiral channels have unique curvature-driven flow characteristics that trigger Dean flow, forcing the liquid to be displaced toward the outer wall of the microchannel due to centrifugal force. Despite the growing popularity of these applications, there is a lack of physical understanding of such particle–fluid two-phase transport in a spiral microchannel. To address this gap, in this paper we employ a coupled particle-transport-microfluidic-flow (two-phase) computational fluid dynamics model for probing such two-phase transport in a curved microchannel that gives rise to Dean flow. Our simulations reveal that the presence of the particles has two effects: (1) they reduce the Dean flow effect of skewing the flow field toward the outer wall, that is, the flow becomes more symmetric (or the velocity maximum moves toward the center of the channel) and (2) there is a significant alteration in the vortex patterns associated with the Dean flow. We quantify the drag and lift forces experienced by the particles and propose that the corresponding particle-imparted drag and the lift forces on the continuous phase counter the effect of the curvature-driven centrifugal force on the continuous phase, thereby altering the Dean flow characteristics. Furthermore, we anticipate that such precise quantification of the forces experienced by these particles, present in finitely large concentration in microfluidic Dean flow, will be critical in designing Dean flow effect driven size-based microfluidic particle separation.
- 1 May 2022
- Published by AIP Publishing in Physics of Fluids
- Vol. 34 (5) , 053304
Particle–liquid transport in curved microchannels: Effect of particle volume fraction and size in Dean flow
Microfluidic transport in spiral channels is a promising flow-driven mechanism for applications such as cell sorting and particle focusing. Spiral channels have unique curvature-driven flow characteristics that trigger Dean flow, forcing the liquid to be displaced toward the outer wall of the microchannel due to centrifugal force. Despite the growing popularity of these applications, there is a lack of physical understanding of such particle–fluid two-phase transport in a spiral microchannel. To address this gap, in this paper we employ a coupled particle-transport-microfluidic-flow (two-phase) computational fluid dynamics model for probing such two-phase transport in a curved microchannel that gives rise to Dean flow. Our simulations reveal that the presence of the particles has two effects: (1) they reduce the Dean flow effect of skewing the flow field toward the outer wall, that is, the flow becomes more symmetric (or the velocity maximum moves toward the center of the channel) and (2) there is a significant alteration in the vortex patterns associated with the Dean flow. We quantify the drag and lift forces experienced by the particles and propose that the corresponding particle-imparted drag and the lift forces on the continuous phase counter the effect of the curvature-driven centrifugal force on the continuous phase, thereby altering the Dean flow characteristics. Furthermore, we anticipate that such precise quantification of the forces experienced by these particles, present in finitely large concentration in microfluidic Dean flow, will be critical in designing Dean flow effect driven size-based microfluidic particle separation.