Amir Movafeghi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Amir Movafeghi has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Effat Yahaghi
Department of Physics, Imam Khomeini International University, Qazvin, Iran
9 shared publications - Mahdi Mirzapour
Department of Mathematics, Faculty of Sciences, Bu-Ali Sina University, Hamedan, Iran
6 shared publications Effat Yahaghi
Department of Physics, Imam Khomeini International University, Qazvin, Iran
4 shared publicationsMahdi Mirzapour
4 shared publications- José Antonio Madrid García
Universitat Politècnica de València
3 shared publications - Ali Keshavarz Nasab
Shahid Rajaee University, Tehran, Iran
2 shared publications
Latest Publications
- 22 June 2025
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 44 (3) , 1-8
Retinex Theory Based Automated Contrast Enhancement of Gamma Radiographic Images of Pipe Welds
- 22 June 2025
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 44 (3) , 1-8
Retinex Theory Based Automated Contrast Enhancement of Gamma Radiographic Images of Pipe Welds
- Open Access
- 1 December 2024
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 29 (12)
Case study of the structure of an Ica-Fono with industrial radiography
The ancient gramophones have a special worthiness in culture and industry and protection of these gramophones is essential. To analyze the internal structure of a gramophone, we need some methods that give us good information without destruction and damage to our valuable objects. One of these non-destructive methods is radiography testing (RT). In this method, which is based on the penetration of X or Gamma photons into materials, the internal information of the device can be obtained with radiography images. In this research, an ancient gramophone has been examined by radiography method and its internal structure and components have been examined. The Iterative Gaussian Convolution Filter (IGCF) image processing method has been used to remove the opacity and increase the contrast. The results indicate that components of the gramophone, such as the turntable motor and starter handle, along with their connections, are visible in the radiographic images. In the images reconstructed by IGCF, sharper edges and improved clarity of execution and internal connections are observed. This information aids repair and maintenance professionals in safeguarding the device from further damage.
- 1 December 2024
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 29 (12)
Open AccessCase study of the structure of an Ica-Fono with industrial radiography
The ancient gramophones have a special worthiness in culture and industry and protection of these gramophones is essential. To analyze the internal structure of a gramophone, we need some methods that give us good information without destruction and damage to our valuable objects. One of these non-destructive methods is radiography testing (RT). In this method, which is based on the penetration of X or Gamma photons into materials, the internal information of the device can be obtained with radiography images. In this research, an ancient gramophone has been examined by radiography method and its internal structure and components have been examined. The Iterative Gaussian Convolution Filter (IGCF) image processing method has been used to remove the opacity and increase the contrast. The results indicate that components of the gramophone, such as the turntable motor and starter handle, along with their connections, are visible in the radiographic images. In the images reconstructed by IGCF, sharper edges and improved clarity of execution and internal connections are observed. This information aids repair and maintenance professionals in safeguarding the device from further damage.
- 19 November 2024
- Published by Elsevier in Journal of Cultural Heritage
- Vol. 71, 30-37
Locating cracks in old toys from the 1950s crafted with an elastomeric material
- 19 November 2024
- Published by Elsevier in Journal of Cultural Heritage
- Vol. 71, 30-37
Locating cracks in old toys from the 1950s crafted with an elastomeric material
- Open Access
- 15 November 2024
- Published by Synsint Research Group in Synthesis and Sintering
- Vol. 4 (4) , 241-247
Neutron shielding performance of polyethylene-7% B and Al-30 wt% B4C composites fabricated via hot-press sintering
The current research aims to investigate the neutron shielding features of polyethylene-7% B and Al-30 wt% B4C composites that are fabricated via the hot-press sintering. The practical analysis was conducted via Neutron radiography and simulation through MCNP code. The results illustrated the Al-30 wt% B4C with 5 mm thickness has equivalent neutron absorption properties with 14 mm thickness of PE-%7 B. Composites with higher density and homogenous distribution of B4C have a better neutron shield property. Al-30 wt% B4C Composite fabricated at 650 °C has a higher neutron absorption property. Experimental and simulation findings confirmed each other at the lower thicknesses and Al-30 wt% B4C has better neutron shielding than PE-7% B. At thicknesses over 1 cm, the amount of cross-sectional area of polyethylene-7% B and Al-30 wt% B4C composites are near to each other. By increasing the thicknesses of composites, the relative total dose reduction and the shield properties of composites are enhanced.
- 15 November 2024
- Published by Synsint Research Group in Synthesis and Sintering
- Vol. 4 (4) , 241-247
Open AccessNeutron shielding performance of polyethylene-7% B and Al-30 wt% B4C composites fabricated via hot-press sintering
The current research aims to investigate the neutron shielding features of polyethylene-7% B and Al-30 wt% B4C composites that are fabricated via the hot-press sintering. The practical analysis was conducted via Neutron radiography and simulation through MCNP code. The results illustrated the Al-30 wt% B4C with 5 mm thickness has equivalent neutron absorption properties with 14 mm thickness of PE-%7 B. Composites with higher density and homogenous distribution of B4C have a better neutron shield property. Al-30 wt% B4C Composite fabricated at 650 °C has a higher neutron absorption property. Experimental and simulation findings confirmed each other at the lower thicknesses and Al-30 wt% B4C has better neutron shielding than PE-7% B. At thicknesses over 1 cm, the amount of cross-sectional area of polyethylene-7% B and Al-30 wt% B4C composites are near to each other. By increasing the thicknesses of composites, the relative total dose reduction and the shield properties of composites are enhanced.
- 5 January 2024
- Published by Elsevier in Journal of Cultural Heritage
- Vol. 66, 415-425
Improving X-ray images of historically significant textiles
- 5 January 2024
- Published by Elsevier in Journal of Cultural Heritage
- Vol. 66, 415-425
Improving X-ray images of historically significant textiles
- 9 December 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 204, 111142
Defect detection enhancement using Gaussian Sparse Models
- 9 December 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 204, 111142
Defect detection enhancement using Gaussian Sparse Models
- 10 September 2023
- Published by Taylor & Francis in Studies in Conservation
- Vol. 69 (7) , 596-607
Improved Utilization of Radiographs of Ancient Metal Objects under Heterogeneous Image Blurring
- 10 September 2023
- Published by Taylor & Francis in Studies in Conservation
- Vol. 69 (7) , 596-607
Improved Utilization of Radiographs of Ancient Metal Objects under Heterogeneous Image Blurring
- 14 June 2021
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 136 (6) , 1-11
Using nonlocal operators for measuring dimensions of defects in radiograph of welded objects
- 14 June 2021
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 136 (6) , 1-11
Using nonlocal operators for measuring dimensions of defects in radiograph of welded objects
- 28 May 2021
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 40 (2) , 1-9
Defect Measurement in Welded Objects by Radiography Testing and Chambolle’s Image Processing Method
- 28 May 2021
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 40 (2) , 1-9
Defect Measurement in Welded Objects by Radiography Testing and Chambolle’s Image Processing Method
- 1 January 2021
- Published by Pleiades Publishing Ltd in Russian Journal of Nondestructive Testing
- Vol. 57 (1) , 61-71
Patch-Based Weld Defect Segmentation and Classification Using Anisotropic Diffusion Image Enhancement Combined with Support-Vector Machine
Several factors such as low image quality, limited human eye resolution, and biased interpretation make the manual radiography testing defect detection erroneous. The aim of this paper is to design a semi-automatic but accurate feature extraction and classification framework, using radiography images of welded joints represented in the GDXray image database. We have trained our support-vector machine classifier with crack, porosity and lack of penetration as the three more frequent classes of radiography defects. The images are segmented after binarization followed by a two-stage image enhancement technique. The body of the two-stage method is made up of an anisotropic diffusion Gaussian filtering, morphological edge detection, and low-pass Gaussian filtering. A three-class support-vector machine based on One-vs.-All implementation of the binary support-vector machine is created, trained, and tested. The method also involves manual adjustments which makes it semi-automatic, and compared to other studies, it is proved to work best with GDXray, a freely available comprehensive radiography image database. The effect of incorporating different optimization algorithms for solving the inherent optimization problem in support-vector machine theory, and utilizing various image processing techniques on defect detection is studied. We show that the combination of image processing and support-vector machine would result in a better performance than the previous studies using the same database.
- 1 January 2021
- Published by Pleiades Publishing Ltd in Russian Journal of Nondestructive Testing
- Vol. 57 (1) , 61-71
Patch-Based Weld Defect Segmentation and Classification Using Anisotropic Diffusion Image Enhancement Combined with Support-Vector Machine
Several factors such as low image quality, limited human eye resolution, and biased interpretation make the manual radiography testing defect detection erroneous. The aim of this paper is to design a semi-automatic but accurate feature extraction and classification framework, using radiography images of welded joints represented in the GDXray image database. We have trained our support-vector machine classifier with crack, porosity and lack of penetration as the three more frequent classes of radiography defects. The images are segmented after binarization followed by a two-stage image enhancement technique. The body of the two-stage method is made up of an anisotropic diffusion Gaussian filtering, morphological edge detection, and low-pass Gaussian filtering. A three-class support-vector machine based on One-vs.-All implementation of the binary support-vector machine is created, trained, and tested. The method also involves manual adjustments which makes it semi-automatic, and compared to other studies, it is proved to work best with GDXray, a freely available comprehensive radiography image database. The effect of incorporating different optimization algorithms for solving the inherent optimization problem in support-vector machine theory, and utilizing various image processing techniques on defect detection is studied. We show that the combination of image processing and support-vector machine would result in a better performance than the previous studies using the same database.