Yoshiyuki Iwata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yoshiyuki Iwata has a total of 646 co-authors. Here are the top co-authors by number of shared publications:
T. Murakami
National Institute of Radiological Science, Chiba, Japan
30 shared publications- Kota Mizushima
Department of Accelerator and Medical Physics, Institute for Quantum Medical Science, National Institutes for Quantum Science and Technology, Chiba, Japan
28 shared publications T. Fujimoto
23 shared publicationsK. Noda
21 shared publicationsS. Sato
18 shared publicationsT. Shirai
Department of Accelerator and Medical Physics, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan
18 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 29 (9) , 093201
324-MHz interdigital H -mode drift tube linac for muon acceleration
We have constructed a 324-MHz interdigital H -mode drift tube linear accelerator (IH-DTL) with an alternating phase focusing method. This IH-DTL will be part of a muon linear accelerator (linac) being developed at the Japan Proton Accelerator Research Complex for a precise measurement of the muon anomalous magnetic moment and a search for the muon electric dipole moment. The IH-DTL is 1.45 m long and accelerates muons from β = v / c = 0.08 to 0.28. Low-power tuning was performed using six slug tuners, which reduced the peak-to-peak on-axis field error to 1.4 % . Following 94 h of high-power conditioning, the IH-DTL demonstrated stable operation at the nominal peak power of 390 kW and a duty factor of 0.1%, corresponding to the designed accelerating field ( E 0 ) of 3.6 MV / m . This paper presents the construction, low-power rf tuning, and high-power performance of the 324-MHz IH-DTL.
- 1 September 2026
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 29 (9) , 093201
Open Access324-MHz interdigital H -mode drift tube linac for muon acceleration
We have constructed a 324-MHz interdigital H -mode drift tube linear accelerator (IH-DTL) with an alternating phase focusing method. This IH-DTL will be part of a muon linear accelerator (linac) being developed at the Japan Proton Accelerator Research Complex for a precise measurement of the muon anomalous magnetic moment and a search for the muon electric dipole moment. The IH-DTL is 1.45 m long and accelerates muons from β = v / c = 0.08 to 0.28. Low-power tuning was performed using six slug tuners, which reduced the peak-to-peak on-axis field error to 1.4 % . Following 94 h of high-power conditioning, the IH-DTL demonstrated stable operation at the nominal peak power of 390 kW and a duty factor of 0.1%, corresponding to the designed accelerating field ( E 0 ) of 3.6 MV / m . This paper presents the construction, low-power rf tuning, and high-power performance of the 324-MHz IH-DTL.
- 14 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (1) , 01TR03
Neon ion radiotherapy: physics and biology
Neon ion ( 20 Ne) beam radiotherapy was one of the primary particle therapy candidates investigated during the clinical trials beginning in the 1970s at the Lawrence Berkely National Laboratory (LBNL), which shut down in the early 1990s. Currently, therapeutic neon ion beams are available at only one clinical facility worldwide, the National Institutes for Quantum Science and Technology (QST) in Chiba, Japan. Recently, neon ion beams were commissioned at QST Hospital as part of the first clinical multi-ion therapy (MIT) program, which aims to improve clinical outcomes by escalating higher linear energy transfer (LET) radiation in the tumor for treating therapy-resistant disease. With the advancement of high-precision scanning delivery techniques, neon ion treatments in the present day could be delivered more safely and with greater precision compared to the first and only clinical application decades prior at LBNL using passive scattering technology. Despite their promising results, preclinical investigations of neon ions are scarce outside of Japan and further independent studies are needed. Clinically, neon ion therapy may offer benefits in treating certain malignancies by escalating LET in the tumor, but its limited availability and high costs restrict its current use and adoption. Studies have shown that 20 Ne or multi-ion mixtures ( 4 He, 12 C, 16 O and/or 20 Ne) can provide larger degrees of freedom in optimization of dose, LET and relative biological effectiveness, otherwise unattainable with other single ion techniques. Neon ion beams are under investigation in the ongoing MIT clinical trials which will establish their broader applicability. In this review, the technology, physics, radiobiology, and potential clinical applications of neon ion beams are outlined. The status of therapeutic neon ion beams is provided while discussing future research and clinical directions, including technological development of novel particle therapy delivery techniques, such as multi-ion, mini-beam, arc, and ultra-high dose rate.
- 14 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (1) , 01TR03
Neon ion radiotherapy: physics and biology
Neon ion ( 20 Ne) beam radiotherapy was one of the primary particle therapy candidates investigated during the clinical trials beginning in the 1970s at the Lawrence Berkely National Laboratory (LBNL), which shut down in the early 1990s. Currently, therapeutic neon ion beams are available at only one clinical facility worldwide, the National Institutes for Quantum Science and Technology (QST) in Chiba, Japan. Recently, neon ion beams were commissioned at QST Hospital as part of the first clinical multi-ion therapy (MIT) program, which aims to improve clinical outcomes by escalating higher linear energy transfer (LET) radiation in the tumor for treating therapy-resistant disease. With the advancement of high-precision scanning delivery techniques, neon ion treatments in the present day could be delivered more safely and with greater precision compared to the first and only clinical application decades prior at LBNL using passive scattering technology. Despite their promising results, preclinical investigations of neon ions are scarce outside of Japan and further independent studies are needed. Clinically, neon ion therapy may offer benefits in treating certain malignancies by escalating LET in the tumor, but its limited availability and high costs restrict its current use and adoption. Studies have shown that 20 Ne or multi-ion mixtures ( 4 He, 12 C, 16 O and/or 20 Ne) can provide larger degrees of freedom in optimization of dose, LET and relative biological effectiveness, otherwise unattainable with other single ion techniques. Neon ion beams are under investigation in the ongoing MIT clinical trials which will establish their broader applicability. In this review, the technology, physics, radiobiology, and potential clinical applications of neon ion beams are outlined. The status of therapeutic neon ion beams is provided while discussing future research and clinical directions, including technological development of novel particle therapy delivery techniques, such as multi-ion, mini-beam, arc, and ultra-high dose rate.
- 24 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Design Study of Conical-Canted-Cosine-Theta Scanning Magnet for Heavy Ion Therapy
In heavy ion therapy, miniaturizing not only the accelerators, beamlines, or magnets but also the power supplies are crucial for downsizing the facility and reducing the installation costs. The use of combined-function superconducting magnets and discrete-cosine-theta combined X-Y scanning magnets (SCM) has already significantly reduced the gantry’s rotating radius. However, reducing the length of the beam delivery system by introducing conventional SCM significantly increases the power supply’s nominal capacity. In this study, a canted-cosine-theta (CCT) SCM is proposed to address these challenges while maintaining the same length of the beam delivery system. Its magnetic field strength is less dependent on the aperture, making it particularly suitable for SCM that requires a large aperture at the outlet. This paper describes the conceptual design of a combined X-Y SCM with conical-CCT winding and its performance.
- 24 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Design Study of Conical-Canted-Cosine-Theta Scanning Magnet for Heavy Ion Therapy
In heavy ion therapy, miniaturizing not only the accelerators, beamlines, or magnets but also the power supplies are crucial for downsizing the facility and reducing the installation costs. The use of combined-function superconducting magnets and discrete-cosine-theta combined X-Y scanning magnets (SCM) has already significantly reduced the gantry’s rotating radius. However, reducing the length of the beam delivery system by introducing conventional SCM significantly increases the power supply’s nominal capacity. In this study, a canted-cosine-theta (CCT) SCM is proposed to address these challenges while maintaining the same length of the beam delivery system. Its magnetic field strength is less dependent on the aperture, making it particularly suitable for SCM that requires a large aperture at the outlet. This paper describes the conceptual design of a combined X-Y SCM with conical-CCT winding and its performance.
- 23 August 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1068
Magnetic properties of a non-oriented electrical steel at cryogenic temperature for rapid-cycling accelerator superconducting magnets
- 23 August 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1068
Magnetic properties of a non-oriented electrical steel at cryogenic temperature for rapid-cycling accelerator superconducting magnets
- 1 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Pattern Excitation Tests of the Short Model Superconducting Magnet for a Compact Heavy-Ion Synchrotron
A project to develop a compact heavy-ion radiotherapy system is underway at the National Institutes for Quantum Science and Technology (QST). One of the aims of this project is to downsize the synchrotron by applying superconducting technology, and we have been developing a superconducting magnet for this system in collaboration with QST. This superconducting magnet was designed to generate a dipole field of 3.5 T at a rapid cycle of more than 0.64 T/s by applying the conduction cooling method and using 4 K Gifford-McMahon (GM) cryocoolers. Such high-speed excitation generates large AC loss, and this heat generation is one of the major issues in this development. Therefore, we fabricated a short straight model magnet and carried out pattern excitation tests to verify the thermal design. This model magnet has the same cross section as the full scale magnet, but its length is shortened by 1/3. In the pattern excitation test repeated 50 times, the maximum coil temperature was calculated to be 4.03 K and measured to be 3.82 K. The quench occurred at 5.9 K, which is near the temperature of 5.76 K where the load factor is expected to be 100% in overload test. This pattern excitation test results shows that the coil performance was obtained as expected. Also, the consistency between the calculations and the test results confirmed that the conduction cooling method using 4 K GM cryocoolers is applicable to the full scale superconducting magnet for the synchrotron. In this paper, the excitation test results are reported.
- 1 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Pattern Excitation Tests of the Short Model Superconducting Magnet for a Compact Heavy-Ion Synchrotron
A project to develop a compact heavy-ion radiotherapy system is underway at the National Institutes for Quantum Science and Technology (QST). One of the aims of this project is to downsize the synchrotron by applying superconducting technology, and we have been developing a superconducting magnet for this system in collaboration with QST. This superconducting magnet was designed to generate a dipole field of 3.5 T at a rapid cycle of more than 0.64 T/s by applying the conduction cooling method and using 4 K Gifford-McMahon (GM) cryocoolers. Such high-speed excitation generates large AC loss, and this heat generation is one of the major issues in this development. Therefore, we fabricated a short straight model magnet and carried out pattern excitation tests to verify the thermal design. This model magnet has the same cross section as the full scale magnet, but its length is shortened by 1/3. In the pattern excitation test repeated 50 times, the maximum coil temperature was calculated to be 4.03 K and measured to be 3.82 K. The quench occurred at 5.9 K, which is near the temperature of 5.76 K where the load factor is expected to be 100% in overload test. This pattern excitation test results shows that the coil performance was obtained as expected. Also, the consistency between the calculations and the test results confirmed that the conduction cooling method using 4 K GM cryocoolers is applicable to the full scale superconducting magnet for the synchrotron. In this paper, the excitation test results are reported.
- 9 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Conceptual Design of Scanning Magnets Using HTS Coils Wound With Spiral Copper-Plated Striated Coated-Conductor (SCSC) Cables for Carbon-ion Radiotherapy
When we reduce the size of a rotating gantry using high field superconducting bending magnets, we must also increase the magnetic field of scanning magnets. We conceptually designed scanning magnets using HTS coils wound with Spiral Copper-plated Striated Coated-conductor (SCSC) cable, which is a low-ac-loss, high current cable concept. The coils were designed to cooled at 65 K by using liquid nitrogen. We conducted the two-dimensional cross-sectional design of the HTS coils as well as warm iron yokes by finite element magnetic field analysis. AC losses in the HTS coils and iron losses in the yokes were calculated. Electrical power consumption to excite the magnets, liquid nitrogen consumption to cool the HTS coils, and the terminal voltages of the magnets were calculated to discuss the feasibility of the designed scanning magnets.
- 9 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Conceptual Design of Scanning Magnets Using HTS Coils Wound With Spiral Copper-Plated Striated Coated-Conductor (SCSC) Cables for Carbon-ion Radiotherapy
When we reduce the size of a rotating gantry using high field superconducting bending magnets, we must also increase the magnetic field of scanning magnets. We conceptually designed scanning magnets using HTS coils wound with Spiral Copper-plated Striated Coated-conductor (SCSC) cable, which is a low-ac-loss, high current cable concept. The coils were designed to cooled at 65 K by using liquid nitrogen. We conducted the two-dimensional cross-sectional design of the HTS coils as well as warm iron yokes by finite element magnetic field analysis. AC losses in the HTS coils and iron losses in the yokes were calculated. Electrical power consumption to excite the magnets, liquid nitrogen consumption to cool the HTS coils, and the terminal voltages of the magnets were calculated to discuss the feasibility of the designed scanning magnets.
- 19 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Field Measurements of Prototype Superconducting Magnet for a Compact Heavy-Ion Therapy Synchrotron
A synchrotron using superconducting magnets has been designed for a next-generation heavy-ion therapy system at National Institutes for Quantum Science and Technology. The maximum central field and ramp rate of their magnets are 3.5 T and 0.7 T/s, respectively, and a field homogeneity of 10 –4 unit is required. To verify field generation and thermal characteristics, a prototype superconducting magnet was fabricated. This first prototype was designed as a short-straight model with a length of 400 mm and a cross section equal to that of a full-scale magnet. The magnet was conduction-cooled at cryogenic temperatures and energized up to a nominal current of 265 A. Its central field was then measured by hall sensors. Descriptions of the design and fabrication of the first prototype magnet and the results of the magnetic-field measurements are reported in this paper.
- 19 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Field Measurements of Prototype Superconducting Magnet for a Compact Heavy-Ion Therapy Synchrotron
A synchrotron using superconducting magnets has been designed for a next-generation heavy-ion therapy system at National Institutes for Quantum Science and Technology. The maximum central field and ramp rate of their magnets are 3.5 T and 0.7 T/s, respectively, and a field homogeneity of 10 –4 unit is required. To verify field generation and thermal characteristics, a prototype superconducting magnet was fabricated. This first prototype was designed as a short-straight model with a length of 400 mm and a cross section equal to that of a full-scale magnet. The magnet was conduction-cooled at cryogenic temperatures and energized up to a nominal current of 265 A. Its central field was then measured by hall sensors. Descriptions of the design and fabrication of the first prototype magnet and the results of the magnetic-field measurements are reported in this paper.
- 11 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-6
Analysis of the Magnetization-Induced Field Error in a Superconducting Bending Magnet for a Compact, Rapid-Cycling Heavy-Ion Synchrotron
An ongoing design study of a 90-degree superconducting bending magnet (SCBM) is being conducted for a compact, rapid-cycling heavy-ion synchrotron at the National Institutes for Quantum Science and Technology (QST). The SCBM is designed to generate a 3.5 T dipole field and a 1.5 T $\cdot$ m $^{-1}$ quadrupole field for bending and horizontally defocusing heavy-ion beams. Since a heavy-ion beam is injected into the synchrotron at the field of 0.3 T, and accelerated to 3.5 T in 5 s, and then it is extracted at the field range from 1.1 T to 3.5 T, field errors derived from the magnetization at such a ramp rate will cause instability of the beam during the acceleration. In this paper, the field errors derived from both the DC and the AC effects are analyzed with numerical models in two dimensions (2D). The DC effects from the screening current in the superconducting coil and iron hysteresis behavior are estimated by the nested ellipse model and the finite element method (FEM) coupled with an inverse Jiles-Atherton model. The AC effects from the eddy current generated in the thermal shield, the beam pipe and the thermal path are estimated by a transient FEM analysis and analytical method. The change of the field error due to the magnetization is estimated to be about 1 unit at the time of beam injection.
- 11 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-6
Analysis of the Magnetization-Induced Field Error in a Superconducting Bending Magnet for a Compact, Rapid-Cycling Heavy-Ion Synchrotron
An ongoing design study of a 90-degree superconducting bending magnet (SCBM) is being conducted for a compact, rapid-cycling heavy-ion synchrotron at the National Institutes for Quantum Science and Technology (QST). The SCBM is designed to generate a 3.5 T dipole field and a 1.5 T $\cdot$ m $^{-1}$ quadrupole field for bending and horizontally defocusing heavy-ion beams. Since a heavy-ion beam is injected into the synchrotron at the field of 0.3 T, and accelerated to 3.5 T in 5 s, and then it is extracted at the field range from 1.1 T to 3.5 T, field errors derived from the magnetization at such a ramp rate will cause instability of the beam during the acceleration. In this paper, the field errors derived from both the DC and the AC effects are analyzed with numerical models in two dimensions (2D). The DC effects from the screening current in the superconducting coil and iron hysteresis behavior are estimated by the nested ellipse model and the finite element method (FEM) coupled with an inverse Jiles-Atherton model. The AC effects from the eddy current generated in the thermal shield, the beam pipe and the thermal path are estimated by a transient FEM analysis and analytical method. The change of the field error due to the magnetization is estimated to be about 1 unit at the time of beam injection.