José Luís Alexandre
Research Subjects
Research Interests
José Luís Alexandre has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Abel Rouboa
INEGI/LAETA Mechanical Engineering Department, Faculty of Engineering, University of Porto, 4099-002 Porto, Portugal
7 shared publications - Nuno Couto
INEGI-FEUP, Faculty of Engineering, Porto University, 4200-465 Porto, Portugal
3 shared publications - Valter Silva
Polytechnic Institute of Portalegre, 7300-110 Portalegre, Portugal
3 shared publications A. Freire
Department of Mechanical Engineering, Faculty of Engineering, University of Porto, Portugal
2 shared publicationsKarla Gonçalves
2 shared publicationsNuno Couto
2 shared publications
Latest Publications
- Open Access
- 31 March 2026
- Published by Elsevier in Energy Conversion and Management
- Vol. 357
Strategic and technical challenges in the deployment of a national CO2 transport network
- 31 March 2026
- Published by Elsevier in Energy Conversion and Management
- Vol. 357
Open AccessStrategic and technical challenges in the deployment of a national CO2 transport network
- 1 January 2019
- Published by AIP Publishing
- Vol. 2133, 450099
Energy performance analysis on a radiative cooling storage system
- 1 January 2019
- Published by AIP Publishing
- Vol. 2133, 450099
Energy performance analysis on a radiative cooling storage system
- 1 January 2019
- Published by AIP Publishing
- Vol. 2133, 450098
Analysis of chiller performance using expeditious indirect methods
- 1 January 2019
- Published by AIP Publishing
- Vol. 2133, 450098
Analysis of chiller performance using expeditious indirect methods
- Open Access
- 1 November 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 415 (1) , 012021
Energy Certification Label vs. Passive Discomfort Index for existing dwellings
Several studies highlight the significant differences between theoretical energy consumptions, - considered in the Energy Certification Schemes (ECS), following the Energy Performance of Buildings Directive (EPBD) -, and the actual energy household consumptions, obtained from extended surveys and monitoring campaigns, especially in Southern European countries. These differences are referred in the literature as "heating gaps". Actual consumptions are significantly unpredictable (depending on outdoor climate, income, energy prices, cultural habits, etc.), but, in most cases, lower than permanent heating/cooling assumptions, present on regulations. This inaccuracy may lead to the suggestion of inappropriate measures on ECS, for low energy-consumption dwellings. Inappropriate because the impact of the same measure on energy consumptions and thermal comfort is different for cases with a permanent heating behavior and cases without it, and because it may lead to hygrothermal pathologies and, finally, an economic mistake, as the real payback time of that measure will be higher than the one suggested, misleading economically more vulnerable households. A complementary approach for the evaluation of thermal performance in existing dwellings, considering intermittent heating scenarios is proposed, by the definition of the "Passive Discomfort Index" (PDI), complementary to the energy label. This index is quantified by the calculation of the temperatures outside the comfort range within the building, in realistic use conditions. A 19th century building, located in Porto, was used to perform a monitoring campaign of temperature and HR to calibrate a numerical model, developed using an advanced simulation tool. It was then performed a sensivity analysis, comparing the energy label with the PDI value, for different retrofitting scenarios, mainly with different insulation thicknesses. The results show that there is no obvious relation between the energy label and the comfort conditions, for intermittent heating scenarios, among others, reinforcing the need of a complementary approach. This is especially important for existent buildings and for Southern European countries, where the "heating gap" is higher.
- 1 November 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 415 (1) , 012021
Open AccessEnergy Certification Label vs. Passive Discomfort Index for existing dwellings
Several studies highlight the significant differences between theoretical energy consumptions, - considered in the Energy Certification Schemes (ECS), following the Energy Performance of Buildings Directive (EPBD) -, and the actual energy household consumptions, obtained from extended surveys and monitoring campaigns, especially in Southern European countries. These differences are referred in the literature as "heating gaps". Actual consumptions are significantly unpredictable (depending on outdoor climate, income, energy prices, cultural habits, etc.), but, in most cases, lower than permanent heating/cooling assumptions, present on regulations. This inaccuracy may lead to the suggestion of inappropriate measures on ECS, for low energy-consumption dwellings. Inappropriate because the impact of the same measure on energy consumptions and thermal comfort is different for cases with a permanent heating behavior and cases without it, and because it may lead to hygrothermal pathologies and, finally, an economic mistake, as the real payback time of that measure will be higher than the one suggested, misleading economically more vulnerable households. A complementary approach for the evaluation of thermal performance in existing dwellings, considering intermittent heating scenarios is proposed, by the definition of the "Passive Discomfort Index" (PDI), complementary to the energy label. This index is quantified by the calculation of the temperatures outside the comfort range within the building, in realistic use conditions. A 19th century building, located in Porto, was used to perform a monitoring campaign of temperature and HR to calibrate a numerical model, developed using an advanced simulation tool. It was then performed a sensivity analysis, comparing the energy label with the PDI value, for different retrofitting scenarios, mainly with different insulation thicknesses. The results show that there is no obvious relation between the energy label and the comfort conditions, for intermittent heating scenarios, among others, reinforcing the need of a complementary approach. This is especially important for existent buildings and for Southern European countries, where the "heating gap" is higher.
- 1 March 2013
- Published by Elsevier in Applied Thermal Engineering
- Vol. 51 (1-2) , 1124-1134
Compact buried pipes system analysis for indoor air conditioning
- 1 March 2013
- Published by Elsevier in Applied Thermal Engineering
- Vol. 51 (1-2) , 1124-1134
Compact buried pipes system analysis for indoor air conditioning
- 1 March 2013
- Published by American Scientific Publishers in Advanced Science Letters
- Vol. 19 (3) , 946-949
Analysis of the Pine Biomass Gasification to Obtain H2 Enriched Syngas
- 1 March 2013
- Published by American Scientific Publishers in Advanced Science Letters
- Vol. 19 (3) , 946-949
Analysis of the Pine Biomass Gasification to Obtain H2 Enriched Syngas
- 1 February 2013
- Published by American Scientific Publishers in Advanced Science Letters
- Vol. 19 (2) , 609-614
Syngas Combustion: Analysis of Exergy Losses
- 1 February 2013
- Published by American Scientific Publishers in Advanced Science Letters
- Vol. 19 (2) , 609-614
Syngas Combustion: Analysis of Exergy Losses
- 31 October 2011
- Published by Elsevier in Energy Policy
- Vol. 39 (10) , 6390-6399
Impact of European standard EN15251 in the energy certification of services buildings—A Portuguese study case
- 31 October 2011
- Published by Elsevier in Energy Policy
- Vol. 39 (10) , 6390-6399
Impact of European standard EN15251 in the energy certification of services buildings—A Portuguese study case
- 1 September 2011
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 10 (2) , 195-204
Energy Consumption Variation due to Different Thermal Comfort Categorization Introduced by European Standard EN 15251 for New Building Design and Major Rehabilitations.
European CEN Standard EN 15251 (2007) requires indoor thermal comfort conditions to be assessed and to fall within a category system for different levels of expectation and building purpose. The COMMONCENSE project has prepared and provided information about the energy implications of the Standard and in particular whether the Standard is encouraging high–energy buildings in the case of new buildings and major rehabilitations. Qualitative and quantitative information about the energy implications of the Standard are given, using a range of different cooling and heating techniques and building forms. More specifically, the required energy consumption of twenty eight buildings of different types (offices, hospitals, schools, residences) in Europe was calculated, assuming that the buildings belong to each of the three thermal comfort categories I, II, III as described in the Standard. From these calculations, it was determined if the thermal comfort categories of the Standard express real satisfaction with the environment and, at the same time, if low energy buildings could easily comply with the Standard. The calculated energy consumption for each type of building was compared against the existing national benchmarks. In general, by changing the thermal comfort category from I to II or to III as defined in EN 15251, a passage of the building from a higher to a lower energy category is noticed, according to each the existing national benchmarks and legislation. Finally, new forms for future standards which are more in keeping with the aspirations of the European Energy Performance of Buildings Directive (EPBD) are suggested. The new standard should be framed in order to encourage low energy buildings since buildings must be comfortable and energy efficient at the same time.
- 1 September 2011
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 10 (2) , 195-204
Energy Consumption Variation due to Different Thermal Comfort Categorization Introduced by European Standard EN 15251 for New Building Design and Major Rehabilitations.
European CEN Standard EN 15251 (2007) requires indoor thermal comfort conditions to be assessed and to fall within a category system for different levels of expectation and building purpose. The COMMONCENSE project has prepared and provided information about the energy implications of the Standard and in particular whether the Standard is encouraging high–energy buildings in the case of new buildings and major rehabilitations. Qualitative and quantitative information about the energy implications of the Standard are given, using a range of different cooling and heating techniques and building forms. More specifically, the required energy consumption of twenty eight buildings of different types (offices, hospitals, schools, residences) in Europe was calculated, assuming that the buildings belong to each of the three thermal comfort categories I, II, III as described in the Standard. From these calculations, it was determined if the thermal comfort categories of the Standard express real satisfaction with the environment and, at the same time, if low energy buildings could easily comply with the Standard. The calculated energy consumption for each type of building was compared against the existing national benchmarks. In general, by changing the thermal comfort category from I to II or to III as defined in EN 15251, a passage of the building from a higher to a lower energy category is noticed, according to each the existing national benchmarks and legislation. Finally, new forms for future standards which are more in keeping with the aspirations of the European Energy Performance of Buildings Directive (EPBD) are suggested. The new standard should be framed in order to encourage low energy buildings since buildings must be comfortable and energy efficient at the same time.
- 15 September 2008
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1048 (1) , 819-822
Numerical Analysis of Convective Heat Transfer in Nanofluid
The main objective of this study is to analyze the heat convection through nanofluids, nanoparticle‐water mixture (7% of particle volume concentration), flowing inside an open system. This study was performed numerically in two dimensional geometry (box) combining fluid flow and heat transfer. The commercial code Ansys® was used to compute the fluid flow and heat transfer between entrance on the top left of the box and the exit on the bottom right. The finite volume method was used to discretize the whole domain in quadratic elements and to linearise the turbulence model. This model was governed by a Re‐Normalized Group Turbulence Model (RNG) turbulence differential equations system coupled with the heat convection. Velocity and temperature in the exit were calculated as function of initial conditions (velocity and temperature) in the entrance of the box (top left). Velocity about 10 m/s and temperatures between 100 K and 300 K were imposed in the entrance. Results showed that the heat transfer in nanofluid, is higher under low temperatures.- 15 September 2008
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1048 (1) , 819-822
Numerical Analysis of Convective Heat Transfer in Nanofluid
The main objective of this study is to analyze the heat convection through nanofluids, nanoparticle‐water mixture (7% of particle volume concentration), flowing inside an open system. This study was performed numerically in two dimensional geometry (box) combining fluid flow and heat transfer. The commercial code Ansys® was used to compute the fluid flow and heat transfer between entrance on the top left of the box and the exit on the bottom right. The finite volume method was used to discretize the whole domain in quadratic elements and to linearise the turbulence model. This model was governed by a Re‐Normalized Group Turbulence Model (RNG) turbulence differential equations system coupled with the heat convection. Velocity and temperature in the exit were calculated as function of initial conditions (velocity and temperature) in the entrance of the box (top left). Velocity about 10 m/s and temperatures between 100 K and 300 K were imposed in the entrance. Results showed that the heat transfer in nanofluid, is higher under low temperatures.