Kamyab Givaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kamyab Givaki has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Lie Xu
Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow, U.K.
2 shared publications Ashkan Giveki
Tehran University Tehran Iran
1 shared publicationD. Chen
Dept. of Eng., Glasgow Caledonian Univ., Glasgow UK
1 shared publication- Dimitrios Vozikis
University of Strathclyde Glasgow UK
1 shared publication Dong Chen
Department of Engineering, Glasgow Caledonian University, Glasgow, United Kingdom
1 shared publication- Dong Chen
National HVDC Centre, Cumbernauld, U.K.
1 shared publication
Latest Publications
- Open Access
- 15 April 2019
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (17) , 4065-4068
Different options for multi‐rotor wind turbine grid connection
Here, different options for integration of the multi‐rotor wind turbine (MRWT) concept are investigated. The intra‐turbine collection network of the MRWT can be designed in either AC or DC. The reliability and costs associated with each connection option are compared. It is presented that the MRWT can be considered as wind farm with the same number of turbines and the same configuration for collection network as for wind farms can be used for MRWT.
- 15 April 2019
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (17) , 4065-4068
Open AccessDifferent options for multi‐rotor wind turbine grid connection
Here, different options for integration of the multi‐rotor wind turbine (MRWT) concept are investigated. The intra‐turbine collection network of the MRWT can be designed in either AC or DC. The reliability and costs associated with each connection option are compared. It is presented that the MRWT can be considered as wind farm with the same number of turbines and the same configuration for collection network as for wind farms can be used for MRWT.
- Open Access
- 17 December 2018
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 3219-3224
Analysis of integration of multi‐terminal HVDC network to weak grids
In this study, the integration of multi‐terminal high voltage direct current (HVDC) systems to weak power grids is analysed under different grid strengths and control methods. In this study, a modular multi‐level converter based MTDC network is considered. The analysis showed the importance of voltage control of DC network. The voltage control of DC network needs to be performed from the converter station connected to the strongest AC network. Furthermore, the analysis shows that either droop or proportional‐integral control can be used for controlling the DC voltage of the MTDC network connected to one or more weak grids. However, the droop control of DC voltage provides faster response compared to PI with larger steady state error. Finally, the analysis showed that the modular multi‐level converter (MMC)‐based MTDC is capable of ride‐through unbalanced AC side faults even if the faults occur in a weak grid.
- 17 December 2018
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 3219-3224
Open AccessAnalysis of integration of multi‐terminal HVDC network to weak grids
In this study, the integration of multi‐terminal high voltage direct current (HVDC) systems to weak power grids is analysed under different grid strengths and control methods. In this study, a modular multi‐level converter based MTDC network is considered. The analysis showed the importance of voltage control of DC network. The voltage control of DC network needs to be performed from the converter station connected to the strongest AC network. Furthermore, the analysis shows that either droop or proportional‐integral control can be used for controlling the DC voltage of the MTDC network connected to one or more weak grids. However, the droop control of DC voltage provides faster response compared to PI with larger steady state error. Finally, the analysis showed that the modular multi‐level converter (MMC)‐based MTDC is capable of ride‐through unbalanced AC side faults even if the faults occur in a weak grid.
- 1 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
An Alternative Current-Error Based Control for VSC Integration to Weak Grid
An enhanced current control strategy is proposed for voltage source converters for the integration to weak grids. The control derives from the current-error based vector control. By implementing simple close-loop compensations of both angle and magnitude inputs to the pulse width modulation, the damping of vector control in the weak grid can be significantly improved hence able to deliver full rated power to very weak grid. Due to the presence of the current loop, the fault-ride-through capability can be maintained with no need for mode switching. A comprehensive frequency domain model is employed to analyze the stability. Time domain simulations are further carried out to validate its effectiveness and robustness of integrating to the weak grid with fault-ride-through capability.
- 1 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
An Alternative Current-Error Based Control for VSC Integration to Weak Grid
An enhanced current control strategy is proposed for voltage source converters for the integration to weak grids. The control derives from the current-error based vector control. By implementing simple close-loop compensations of both angle and magnitude inputs to the pulse width modulation, the damping of vector control in the weak grid can be significantly improved hence able to deliver full rated power to very weak grid. Due to the presence of the current loop, the fault-ride-through capability can be maintained with no need for mode switching. A comprehensive frequency domain model is employed to analyze the stability. Time domain simulations are further carried out to validate its effectiveness and robustness of integrating to the weak grid with fault-ride-through capability.
- 28 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 10 (1) , 26-35
Current Error Based Compensations for VSC Current Control in Weak Grids for Wind Farm Applications
A novel current control strategy is proposed for voltage source converter connecting to weak grid using conventional current vector control with additional current error based voltage angle and magnitude compensations. For connecting to very weak AC network, conventional vector control is proved to be unstable, whereas the proposed current error based compensations can significantly improve system stability. In this way, the proposed control can still benefit from the presence of current closed-loop control without the need for control switching during large AC voltage variations. Comprehensive frequency domain model is established to analyze stability performance. Comprehensive time domain simulations are further carried out to validate its effectiveness and robustness by demonstrating its current control performance during a three-phase fault, multiple-converter situation and various grid strength conditions.
- 28 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 10 (1) , 26-35
Current Error Based Compensations for VSC Current Control in Weak Grids for Wind Farm Applications
A novel current control strategy is proposed for voltage source converter connecting to weak grid using conventional current vector control with additional current error based voltage angle and magnitude compensations. For connecting to very weak AC network, conventional vector control is proved to be unstable, whereas the proposed current error based compensations can significantly improve system stability. In this way, the proposed control can still benefit from the presence of current closed-loop control without the need for control switching during large AC voltage variations. Comprehensive frequency domain model is established to analyze stability performance. Comprehensive time domain simulations are further carried out to validate its effectiveness and robustness by demonstrating its current control performance during a three-phase fault, multiple-converter situation and various grid strength conditions.
- Open Access
- 1 January 2016
- Published by Institution of Engineering and Technology (IET)
- p. 80 (5 .)
Stability studies of different AC collection network topologies in wind farms
In this paper, the stability of different wind farm collection network topologies have been studied. As the wind farm becomes larger, the inter-array network becomes larger so that the impedance of overall system is increased. This means that the inter-array configuration can impact the stability of system. The dynamic studies results presented in this paper show that the star collection network topology has the ability to be connected to weaker grid followed by radial, double sided and single side ring collection network topology.
- 1 January 2016
- Published by Institution of Engineering and Technology (IET)
- p. 80 (5 .)
Open AccessStability studies of different AC collection network topologies in wind farms
In this paper, the stability of different wind farm collection network topologies have been studied. As the wind farm becomes larger, the inter-array network becomes larger so that the impedance of overall system is increased. This means that the inter-array configuration can impact the stability of system. The dynamic studies results presented in this paper show that the star collection network topology has the ability to be connected to weaker grid followed by radial, double sided and single side ring collection network topology.