EHElizabeth G. Halsne

Elizabeth G. Halsne

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Elizabeth G. Halsne has a total of 35 co-authors. Here are the top co-authors by number of shared publications:

  • David Crespi Morgenroth

    Affiliations Center for Limb Loss and MoBility, VA Puget Sound Health Care System, Seattle, Washington, United States of America, Department of Rehabilitation Medicine, University of Washington, Seattle, Washington, United States of America

    7 shared publications
  • Brian J. Hafner

    University of Washington Seattle Washington USA

    6 shared publications
  • Talia R. Ruxin

    School of Medicine, University of California, San Francisco, San Francisco, California, USA

    4 shared publications
  • Andrew H. Hansen

    Affiliations Rehabilitation & Engineering Center for Optimizing Veteran Engagement & Reintegration (RECOVER), Minneapolis VA Health Care System, Minneapolis, Minnesota, United States of America, Department of Family Medicine and Community Health, Rehabilitation Science Program, University of Minnesota, Minneapolis, Minnesota, United States of America

    3 shared publications
  • Anne T. Turner

    Affiliations VA RR&D Center for Limb Loss and Mobility (CLiMB), VA Puget Sound Health Care System, Seattle, Washington, United States of America, Elson S. Floyd College of Medicine, Washington State University, Spokane, Washington, United States of America

    3 shared publications
  • Carl S. Curran

    Affiliation Human Motion Technologies LLC d/b/a Humotech, Pittsburgh, Pennsylvania, United States of America

    3 shared publications

Latest Publications

  • Open Access

    Comparison of Foot-Ankle Biomechanics During Treadmill Walking with Commercially Available and Corresponding Emulated Prosthetic Feet

    by Tyler Keali&Apos;I Ho, Elizabeth G. Halsne, Talia R. Ruxin, David Crespi Morgenroth

    Background A robotic prosthetic foot emulator (PFE) programmed to emulate different prosthetic feet could allow individuals with lower limb loss to quickly ‘test-drive’ different prosthetic feet and provide input to prosthetic foot prescription. While a previous study validated the mechanical properties of the PFE against those of corresponding prosthetic feet, no studies have compared the foot-ankle biomechanics of prosthesis users walking with ‘actual’ and corresponding ‘emulated’ prosthetic feet. Methods Ten unilateral transtibial prosthesis users walked on an instrumented treadmill with three actual and three corresponding emulated prosthetic feet in a randomized order, while masked to foot type. Kinetic and kinematic data collected during steady-state walking were used to calculate prosthesis ankle push-off power, push-off work, effective forefoot length, rollover radius, and step length/time asymmetry. Findings Ankle push-off power and work were greater with the emulated versions of the two stiffer prosthetic feet compared with the corresponding actual feet. The stiffest emulated foot had a longer effective forefoot length than the corresponding actual foot. The least stiff emulated prosthetic foot had a shorter rollover radius than its actual version, while the stiffest emulated prosthetic foot had a longer rollover radius than its actual version. Despite these differences, nine of ten participants correctly identified all three emulated feet; all correctly identified at least one emulated foot. Interpretation These findings suggest that while there are some differences in foot-ankle biomechanics, the PFE accurately simulates the spatiotemporal and perceived aspects of walking with corresponding actual feet.

  • Open Access

    Assessing the effects of prosthetic foot stiffness and foot preference on stability, balance confidence, and satisfaction in transtibial prosthesis users: Protocol for a randomized, participant-masked crossover trial using a ‘test-drive’ strategy

    by Tyler K. Ho, Elizabeth G. Halsne, Sara R. Koehler-McNicholas, Andrew H. Hansen, Andrew Sawers, Joshua M. Caputo, Carl S. Curran, Alexandria Lloyd, Juan Cave, David C. Morgenroth

    Introduction: With an appropriate prescription, the use of a lower limb prosthesis can help mitigate mobility limitations and increased risk of falling for people with lower limb amputation. Prosthetic feet cannot replicate all the functions of a biological foot-ankle. Different feet have different designs and properties, and therefore there are functional trade-offs. There is insufficient evidence as to the effects these different prosthetic foot properties have on users’ stability and balance, which would be helpful to guide clinical prosthesis prescription. Prosthesis users also rarely have opportunities to try walking with different prosthetic feet to give experiential input during the prescription process. Therefore, this study aims to determine 1) the effects of prosthetic foot stiffness on stability in lower limb prosthesis users while walking on varying terrains, and 2) whether a brief ‘test-drive’ strategy for selecting prosthetic feet can be used to predict longer term stability, balance confidence, and foot preference outcomes in lower limb prosthesis users. Methods and Materials: In this multisite, participant-masked, randomized cross-over study, participants with unilateral, transtibial amputation will walk on different treadmill conditions (flat, incline, cross-slopes, uneven ground) with a variety of commercially-available prosthetic feet (‘ actual ’) and corresponding ‘ emulated ’ prosthetic feet in the laboratory. Participants will also wear the actual prosthetic feet at home and in the community for one week at a time. After each community trial, participants will return to the laboratory to complete walking trials on different terrains and at a range of speeds while we collect kinematic data. We will assess the effect of prosthetic foot stiffness on biomechanical and self-reported measures of stability. We will also assess how well brief ‘test-drive’ trials of walking with different prosthetic feet can predict longer-term self-reported measures of stability, balance confidence and preference. Trial registration: This study was prospectively registered at www.clinicaltrials.gov (Clinical Trials Study ID: NCT05473065). Study start date: March 1, 2024.


  • The impact of climate change and related extreme weather on people with limb loss

    by Talia R. Ruxin, David C. Morgenroth, Tarik Benmarhnia, Elizabeth G. Halsne

    The human health consequences of climate change and extreme weather events are well documented. Published literature details the unique effects and necessary adaptation planning for people with physical disabilities in general; however, the specific impacts and plans for people with limb loss have yet to be explored. In this article, we discuss the impacts related to threats due to heat, cold, severe storms, and power outages. We describe how climate change uniquely affects people with limb loss and underscore the need for rehabilitation care providers and researchers to: (1) study the health impacts of climate change on people with lower limb loss; (2) educate themselves and patients on the climate crisis and climate preparedness; (3) co‐develop resiliency strategies with patients, governments, and community organizations to improve adaptive capacity; and (4) advocate for policy changes that will enact protections for this at‐risk population.


  • Perceptions of prosthetic attention among lower limb prosthesis users: a focus group study

    by Cody L. McDonald, Tanu Bhargava, Elizabeth G. Halsne, Susanne M. Van Der Veen, Brian J. Hafner, Benjamin J. Darter

    PurposeUse of a lower limb prosthesis generally requires increased cognitive effort to compensate for missing motor and sensory inputs. This study sought to examine how lower limb prosthesis users perceive paying attention to their prosthesis(es) in daily life.Materials and methodsFocus groups with lower limb prosthesis users were conducted virtually using semi-structured questions. Verbatim transcripts were excerpted, coded, and reconciled. Inductive thematic analysis was undertaken to identify experiences shared by participants.ResultsFive themes emerged from five focus groups conducted with thirty individuals: Paying attention to my prosthesis is just what I have to do; I pay attention to how my prosthetic socket fits and feels every day; I pay attention because I don't want to fall; I pay attention because I have to learn to do things in a new way; and If I can trust that my prosthesis will do what I want, I can pay less attention to it.ConclusionsProsthetic attention, including both background and foreground attention, is a shared experience among lower limb prosthesis users. The amount and frequency of prosthetic attention fluctuates throughout the day and changes over time. Measuring attention could inform the evaluation and prescription of technology intended to reduce cognitive effort. Walking or performing mobility tasks with a prosthesis requires increased attention and may limit the cognitive resources available for other important activities.Lower limb prosthesis users report paying attention to their prosthesis(ses) to avoid falling, to maintain the fit of their prosthetic socket, and to learn to complete mobility tasks with a prosthesis.Clinicians should discuss prosthetic attention with new prosthesis users and explain how it is expected to decrease over time.Prosthetic technology may affect prosthetic attention but development of a measure to assess prosthetic attention is needed to accurately evaluate this relationship.


  • The development of rating scales to evaluate experiential prosthetic foot preference for people with lower limb amputation

    by Talia R. Ruxin, Elizabeth G. Halsne, Brian J. Hafner, Jane Shofer, Andrew H. Hansen, W. Lee Childers, Joshua M. Caputo, David C. Morgenroth

    Background: Selection of a foot is an important aspect of prosthetic prescription and vital to maximizing mobility and functional goals after lower limb amputation. Development of a standardized approach to soliciting user experiential preferences is needed to improve evaluation and comparison of prosthetic feet.Objective: To develop rating scales to assess prosthetic foot preference and to evaluate use of these scales in people with transtibial amputation after trialing different prosthetic feet.Design: Participant‐blinded, repeated measures crossover trial.Setting: Veterans Affairs and Department of Defense Medical Centers, laboratory setting.Participants: Seventy‐two male prosthesis users with unilateral transtibial amputation started, and 68 participants completed this study.Interventions: Participants trialed three mobility‐level appropriate commercial prosthetic feet briefly in the laboratory.Main Outcome Measures: “Activity‐specific” rating scales were developed to assess participants' ability with a given prosthetic foot to perform typical mobility activities (eg, walking at different speeds, on inclines, and stairs) and “global” scales to rate overall perceived energy required to walk, satisfaction, and willingness to regularly use the prosthetic foot. Foot preference was determined by comparing the rating scale scores, after laboratory testing.Results: The greatest within‐participant differences in scores among feet were observed in the “incline” activity, where 57% ± 6% of participants reported 2+ point differences. There was a significant association (p < .05) between all “activity‐specific” rating scores (except standing) and each “global” rating score.Conclusions: The standardized rating scales developed in this study could be used to assess prosthetic foot preference in both the research and clinical settings to guide prosthetic foot prescription for people with lower limb amputation capable of a range of mobility levels.


  • The effect of depression on prosthesis prescription in men and women who have undergone a lower limb amputation

    by Daniel C. Norvell, Aaron P. Turner, David C. Morgenroth, Alison W. Henderson, Elizabeth G. Halsne, Max Hurwitz, Joseph M. Czerniecki

    To determine gender disparities and potential factors that modify prosthesis prescription practices in veteran patients who have undergone their first major unilateral amputation due to diabetes or...


  • Open Access

    Prosthetic forefoot and heel stiffness across consecutive foot stiffness categories and sizes

    by Anne T. Turner, Elizabeth G. Halsne, Joshua M. Caputo, Carl S. Curran, Andrew H. Hansen, Brian J. Hafner, David C. Morgenroth

    Prosthetic foot stiffness plays a key role in the functional mobility of lower limb prosthesis users. However, limited objective data exists to guide selection of the optimal prosthetic foot stiffness category for a given individual. Clinicians often must rely solely on manufacturer recommendations, which are typically based on the intended user’s weight and general activity level. Availability of comparable forefoot and heel stiffness data would allow for a better understanding of differences between different commercial prosthetic feet, and also between feet of different stiffness categories and foot sizes. Therefore, this study compared forefoot and heel linear stiffness properties across manufacturer-designated stiffness categories and foot sizes. Mechanical testing was completed for five types of commercial prosthetic feet across a range of stiffness categories and three foot-sizes. Data were collected for 56 prosthetic feet, in total. Testing at two discrete angles was conducted to isolate loading of the heel and forefoot components, respectively. Each prosthetic foot was loaded for six cycles while force and displacement data were collected. Forefoot and heel measured stiffness were both significantly associated with stiffness category (p = .001). There was no evidence that the relationships between stiffness category and measured stiffness differed by foot size (stiffness category by size interaction p = .80). However, there were inconsistencies between the expected and measured stiffness changes across stiffness categories (i.e., magnitude of stiffness changes varied substantially between consecutive stiffness categories of the same feet). While statistical results support that, on average, measured stiffness is positively correlated with stiffness category, force-displacement data suggest substantial variation in measured stiffness across consecutive categories. Published objective mechanical property data for commercial prosthetic feet would likely therefore be helpful to clinicians during prescription.


  • Comparing forefoot and heel stiffnesses across commercial prosthetic feet manufactured for individuals with varying body weights and foot sizes

    by Talia R. Ruxin, Elizabeth G. Halsne, Anne T. Turner, Carl S. Curran, Joshua M. Caputo, Andrew H. Hansen, Brian J. Hafner, David C. Morgenroth

    Background: Despite the effects of prosthetic foot mechanical properties on gait of people with lower limb amputation, scant forefoot and heel stiffness data exist to help guide prosthetic foot prescription. Objective: To measure forefoot and heel linear stiffness properties across commonly prescribed commercial prosthetic foot models and to describe variations in stiffness across feet targeted for users with different body weights and foot sizes. Study design: Mechanical testing of five types of commercial prosthetic feet across nine user body weight and foot size combinations. Methods: Linear forefoot and heel stiffness (force vs. displacement) data were collected for 41 prosthetic feet. Quasistatic testing was conducted at −15 and +20 degrees to isolate loading of the heel and forefoot, respectively. Results: Overall, there was a significant relationship between user body weight and both forefoot and heel stiffness, when adjusted for foot size and type (P < 0.001). However, there were a substantial number of inconsistencies across foot type within example user body weight and foot sizes combination. Furthermore, the relative order of forefoot stiffness across foot type differed from the relative order of heel stiffness across foot type. Conclusions: The inconsistencies and differences in relative order of forefoot and heel stiffness across commercial foot type suggest the importance of publishing objective stiffness and other mechanical properties of prosthetic feet. These data can aid clinicians in better matching mechanical properties of prosthetic feet with the functional goals and abilities of prosthesis users.


  • Effects of shear force reduction during mechanical testing and day-to-day variation on stiffness of commercial prosthetic feet: a technical note

    by Elizabeth G. Halsne, Anne T. Turner, Carl S. Curran, Andrew H. Hansen, Brian J. Hafner, Joshua M. Caputo, David C. Morgenroth

    Background: Mechanical testing is the principal method used to quantify properties of commercial prosthetic feet in a controlled and standardized manner. To test feet in a mechanical testing machine without overconstraining the system, tangential shear forces must be minimized. However, there is scant published information comparing techniques for reducing shear forces during mechanical testing. Furthermore, there are no data on variability in linear stiffness across testing sessions. Objectives: To compare techniques for reducing shear forces during mechanical testing of prosthetic feet and to evaluate variation in linear stiffness across testing sessions. Study design: Repeated measures. Technique: Force–displacement data were collected at two pylon progression angles, one for the forefoot and one for the heel, and compared across three conditions: roller plate (RoPl), low-friction interface on the shoe (SB), and no method for reducing shear forces (NoSB). Data were collected for a range of commercial prosthetic foot models and sizes. Select data were collected over multiple days to assess variation over test sessions. Results: Differences in stiffness between RoPl and SB test conditions ranged from −0.9% to +2.6% across foot models. By contrast, differences between RoPl and no method for reducing shear conditions ranged from −2.9% to +14.6%. Differences in linear stiffness between test sessions ranged from −2.2% to +3.6%. Conclusions: Methods for reducing shear force in this study demonstrated roughly equivalent effects. Thus, a low-friction interface may be used as a less expensive and less complex method for reducing shear force in prosthetic foot testing. In addition, mechanical testing results were relatively consistent across multiple test sessions, lending confidence to test consistency.


  • Effects of prosthetic feet on metabolic energy expenditure in people with transtibial amputation: A systematic review and meta‐analysis

    by Brian J. Hafner, Elizabeth G. Halsne, Sara J. Morgan, David C. Morgenroth, Andrew T. Humbert

    Objective: To assess the effects of different prosthetic feet on energy costs associated with walking and running in people with transtibial amputation.Literature Survey: The Pubmed, CINAHL, and Web‐of‐Science bibliographic databases were searched for original research published through June 30, 2018. References from identified articles were also reviewed.Methodology: Two reviewers screened titles, abstracts, and articles for pertinent studies. Details were extracted with a standardized template. Risk of bias was assessed using domain‐based methods. Prosthetic feet were grouped into categories and compared according to energy costs associated with walking or running over various terrain conditions. Meta‐analyses were conducted when data quantity and homogeneity permitted. Evidence statements were formed when results were consistent or undisputed.Synthesis: Fifteen studies were included. Participants (n = 141) were predominantly male (87.9%), had unilateral amputation (95.7%) from non‐dysvascular causes (87.9%), and were classified as unlimited community ambulators or active adults (56.0%). Participants were often young but varied in age (mean age 24.8–66.6 years). Available evidence indicates that feet with powered dorsiflexion reduce energy costs relative to dynamic response feet in unlimited community ambulators or active adults when walking on level or declined surfaces. Dynamic response feet do not significantly reduce energy costs compared to energy storing, flexible keel, or solid ankle feet when walking on level terrain. Running feet do not reduce energy costs relative to dynamic response in active adults when running. Select feet may reduce energy costs under specific conditions, but additional research is needed to confirm preliminary results.Conclusions: The overall body of evidence is based on small samples, comprised mostly of participants who may not well represent the population of prosthesis users and test conditions that may not well reflect how prostheses are used in daily life. However, evidence suggests energy costs are affected by prosthetic foot type only under select conditions.