Luigi Rigon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Luigi Rigon has a total of 366 co-authors. Here are the top co-authors by number of shared publications:
- Fulvia Arfelli
Department of Physics, University of Trieste, 34127 Trieste, Italy
17 shared publications - Ralf Hendrick Menk
Elettra Sincrotrone Trieste S.C.p.A, Strada Statale 14, Basovizza (Trieste), Italy
10 shared publications - Pasquale Delogu
Department of Physical Sciences, Earth and Environment, University of Siena, 53100 Siena, Italy
5 shared publications - Luca Brombal
Department of Physics, University of Trieste 1 , Trieste
4 shared publications - Renata Longo
Department of Physics, University of Trieste, Via A. Valerio 2, 34127 Trieste, Italy
4 shared publications A. Brez
INFN sez. di Pisa and PiXirad Imaging Counters srl, Largo B. Pontecorvo 3, Pisa, I-56127 Italy
3 shared publications
Latest Publications
- Open Access
- 29 August 2026
- Published by MDPI AG in Tomography
- Vol. 12 (9) , 124
Radiomic Characterization of Breast Tissue from Breast CT Images Obtained with Synchrotron Beams
Background/Objective: Radiomics offers a powerful, non-invasive approach for extracting quantitative features to predict lesion phenotypes. This study performs a radiomic characterization of breast tissue using synchrotron radiation breast computed tomography (SR-bCT). Method: Four mastectomy samples were imaged at the Australian Synchrotron (ANSTO) using five energies (25, 32, 35, 40, and 60 keV). From 10 slices per energy for each sample, 1546 regions of interest (ROIs) were extracted across four tissue subtypes: fatty, glandular, fibrous, and microcalcified. Using Pyradiomics, 93 features were initially calculated and then reduced to 34, eliminating highly correlated variables to reduce redundancies. Seven linear regression models and a discriminant analysis evaluated subtype tissue separation and radiomic characterization across individuals and combined samples and energies with a good fit (0.81 ≤ R ≤ 0.98). Results: The study identified six possible robust exploratory candidate features independent of sample variability and energy levels, whose mean values are significantly different among the four tissue subtypes (clusters, p < 0.001). The selected candidate features were 90th Percentile, Kurtosis, Skewness, GLCM IDM, GLDM LDE, and NGTDM Coarseness. These metrics successfully differentiated all tissue pairs (microcalcifications/fat, microcalcifications/gland, microcalcifications/fiber, fat/gland, fat/fiber and gland/fiber), with p < 0.05 inside the most general regression model and p < 0.0001 with the linear discriminant separation in clusters. Conclusions: Findings indicate that some first-order and second-order texture metrics reflecting global dependencies remain stable across experimental conditions. Conversely, fine-texture metrics are highly sensitive to sample energy changes, limiting their generalizability. These results align with successful biomarkers in mammography and validate the potential of radiomics in SR-bCT characterization.
- 29 August 2026
- Published by MDPI AG in Tomography
- Vol. 12 (9) , 124
Open AccessRadiomic Characterization of Breast Tissue from Breast CT Images Obtained with Synchrotron Beams
Background/Objective: Radiomics offers a powerful, non-invasive approach for extracting quantitative features to predict lesion phenotypes. This study performs a radiomic characterization of breast tissue using synchrotron radiation breast computed tomography (SR-bCT). Method: Four mastectomy samples were imaged at the Australian Synchrotron (ANSTO) using five energies (25, 32, 35, 40, and 60 keV). From 10 slices per energy for each sample, 1546 regions of interest (ROIs) were extracted across four tissue subtypes: fatty, glandular, fibrous, and microcalcified. Using Pyradiomics, 93 features were initially calculated and then reduced to 34, eliminating highly correlated variables to reduce redundancies. Seven linear regression models and a discriminant analysis evaluated subtype tissue separation and radiomic characterization across individuals and combined samples and energies with a good fit (0.81 ≤ R ≤ 0.98). Results: The study identified six possible robust exploratory candidate features independent of sample variability and energy levels, whose mean values are significantly different among the four tissue subtypes (clusters, p < 0.001). The selected candidate features were 90th Percentile, Kurtosis, Skewness, GLCM IDM, GLDM LDE, and NGTDM Coarseness. These metrics successfully differentiated all tissue pairs (microcalcifications/fat, microcalcifications/gland, microcalcifications/fiber, fat/gland, fat/fiber and gland/fiber), with p < 0.05 inside the most general regression model and p < 0.0001 with the linear discriminant separation in clusters. Conclusions: Findings indicate that some first-order and second-order texture metrics reflecting global dependencies remain stable across experimental conditions. Conversely, fine-texture metrics are highly sensitive to sample energy changes, limiting their generalizability. These results align with successful biomarkers in mammography and validate the potential of radiomics in SR-bCT characterization.
- 12 June 2024
- Published by Elsevier in Measurement
- Vol. 236
Autofinding egg parasitoids in moth eggs by using machine learning methods in synchrotron-coherent X-ray imaging
- 12 June 2024
- Published by Elsevier in Measurement
- Vol. 236
Autofinding egg parasitoids in moth eggs by using machine learning methods in synchrotron-coherent X-ray imaging
- 22 December 2021
- Published by Taylor & Francis
- p. 461-476
Emerging Techniques
The development of medical physics is closely linked with that of contemporary medicine, in particular medical imaging, radiotherapy and related specialities. In 2011, the International Labour Organization (ILO, Geneva) decided to include both ‘medical physicist’ and ‘biomedical engineer’ in the International Standard Classification of Occupations (ISCO) under the professional categories ‘Science and Engineering Professionals’ and ‘Health Professionals’ (Smith and Nusslin, 2013). This remarkable achievement of the International Union for Physical and Engineering Sciences in Medicine (IUPESM), International Organisation for Medical Physics (IOMP) and International Federation for Medical and Biological Engineering (IFMBE) benefits the current 30,000 strong workforce of medical physicists globally and recognises the contribution that physicists and engineers make to healthcare.
- 22 December 2021
- Published by Taylor & Francis
- p. 461-476
Emerging Techniques
The development of medical physics is closely linked with that of contemporary medicine, in particular medical imaging, radiotherapy and related specialities. In 2011, the International Labour Organization (ILO, Geneva) decided to include both ‘medical physicist’ and ‘biomedical engineer’ in the International Standard Classification of Occupations (ISCO) under the professional categories ‘Science and Engineering Professionals’ and ‘Health Professionals’ (Smith and Nusslin, 2013). This remarkable achievement of the International Union for Physical and Engineering Sciences in Medicine (IUPESM), International Organisation for Medical Physics (IOMP) and International Federation for Medical and Biological Engineering (IFMBE) benefits the current 30,000 strong workforce of medical physicists globally and recognises the contribution that physicists and engineers make to healthcare.
- 22 April 2020
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 27 (3) , 762-771
Radiochromic film dosimetry in synchrotron radiation breast computed tomography: a phantom study
This study relates to the INFN project SYRMA-3D for in vivo phase-contrast breast computed tomography using the SYRMEP synchrotron radiation beamline at the ELETTRA facility in Trieste, Italy. This peculiar imaging technique uses a novel dosimetric approach with respect to the standard clinical procedure. In this study, optimization of the acquisition procedure was evaluated in terms of dose delivered to the breast. An offline dose monitoring method was also investigated using radiochromic film dosimetry. Various irradiation geometries have been investigated for scanning the prone patient's pendant breast, simulated by a 14 cm-diameter polymethylmethacrylate cylindrical phantom containing pieces of calibrated radiochromic film type XR-QA2. Films were inserted mid-plane in the phantom, as well as wrapped around its external surface, and irradiated at 38 keV, with an air kerma value that would produce an estimated mean glandular dose of 5 mGy for a 14 cm-diameter 50% glandular breast. Axial scans were performed over a full rotation or over 180°. The results point out that a scheme adopting a stepped rotation irradiation represents the best geometry to optimize the dose distribution to the breast. The feasibility of using a piece of calibrated radiochromic film wrapped around a suitable holder around the breast to monitor the scan dose offline is demonstrated.
- 22 April 2020
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 27 (3) , 762-771
Radiochromic film dosimetry in synchrotron radiation breast computed tomography: a phantom study
This study relates to the INFN project SYRMA-3D for in vivo phase-contrast breast computed tomography using the SYRMEP synchrotron radiation beamline at the ELETTRA facility in Trieste, Italy. This peculiar imaging technique uses a novel dosimetric approach with respect to the standard clinical procedure. In this study, optimization of the acquisition procedure was evaluated in terms of dose delivered to the breast. An offline dose monitoring method was also investigated using radiochromic film dosimetry. Various irradiation geometries have been investigated for scanning the prone patient's pendant breast, simulated by a 14 cm-diameter polymethylmethacrylate cylindrical phantom containing pieces of calibrated radiochromic film type XR-QA2. Films were inserted mid-plane in the phantom, as well as wrapped around its external surface, and irradiated at 38 keV, with an air kerma value that would produce an estimated mean glandular dose of 5 mGy for a 14 cm-diameter 50% glandular breast. Axial scans were performed over a full rotation or over 180°. The results point out that a scheme adopting a stepped rotation irradiation represents the best geometry to optimize the dose distribution to the breast. The feasibility of using a piece of calibrated radiochromic film wrapped around a suitable holder around the breast to monitor the scan dose offline is demonstrated.
- 1 December 2018
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 13 (12) , C12008
Characterization of noise and efficiency of the Pixirad-1/Pixie-III CdTe X-ray imaging detector
- 1 December 2018
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 13 (12) , C12008
Characterization of noise and efficiency of the Pixirad-1/Pixie-III CdTe X-ray imaging detector
- 27 November 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 6 (03) , 031402-9
Monochromatic breast computed tomography with synchrotron radiation: phase-contrast and phase-retrieved image comparison and full-volume reconstruction
A program devoted to performing the first in vivo synchrotron radiation (SR) breast computed tomography (BCT) is ongoing at the Elettra facility. Using the high spatial coherence of SR, phase-contrast (PhC) imaging techniques can be used. The latest high-resolution BCT acquisitions of breast specimens, obtained with the propagation-based PhC approach, are herein presented as part of the SYRMA-3D collaboration effort toward the clinical exam. Images are acquired with a 60-μm pixel dead-time-free single-photon-counting CdTe detector. The samples are imaged at 32 and 38 keV in a continuous rotating mode, delivering 5 to 20 mGy of mean glandular dose. Contrast-to-noise ratio (CNR) and spatial resolution performances are evaluated for both PhC and phase-retrieved images, showing that by applying the phase-retrieval algorithm a five-time CNR increase can be obtained with a minor loss in spatial resolution across soft tissue interfaces. It is shown that, despite having a poorer CNR, PhC images can provide a sharper visualization of microcalcifications, thus being complementary to phase-retrieved images. Furthermore, the first full-volume scan of a mastectomy sample (9 × 9 × 3 cm3) is reported. This investigation into surgical specimens indicates that SR BCT in terms of CNR, spatial resolution, scan duration, and scan volume is feasible.
- 27 November 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 6 (03) , 031402-9
Monochromatic breast computed tomography with synchrotron radiation: phase-contrast and phase-retrieved image comparison and full-volume reconstruction
A program devoted to performing the first in vivo synchrotron radiation (SR) breast computed tomography (BCT) is ongoing at the Elettra facility. Using the high spatial coherence of SR, phase-contrast (PhC) imaging techniques can be used. The latest high-resolution BCT acquisitions of breast specimens, obtained with the propagation-based PhC approach, are herein presented as part of the SYRMA-3D collaboration effort toward the clinical exam. Images are acquired with a 60-μm pixel dead-time-free single-photon-counting CdTe detector. The samples are imaged at 32 and 38 keV in a continuous rotating mode, delivering 5 to 20 mGy of mean glandular dose. Contrast-to-noise ratio (CNR) and spatial resolution performances are evaluated for both PhC and phase-retrieved images, showing that by applying the phase-retrieval algorithm a five-time CNR increase can be obtained with a minor loss in spatial resolution across soft tissue interfaces. It is shown that, despite having a poorer CNR, PhC images can provide a sharper visualization of microcalcifications, thus being complementary to phase-retrieved images. Furthermore, the first full-volume scan of a mastectomy sample (9 × 9 × 3 cm3) is reported. This investigation into surgical specimens indicates that SR BCT in terms of CNR, spatial resolution, scan duration, and scan volume is feasible.
- Open Access
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 75-76
[OA196] First experimental validation of phase-attenuation hybrid X-ray imaging
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 75-76
Open Access[OA196] First experimental validation of phase-attenuation hybrid X-ray imaging
- 1 February 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 5 (01) , 013503-9
Dose and diagnostic performance comparison between phase-contrast mammography with synchrotron radiation and digital mammography: a clinical study report
Two dosimetric quantities [mean glandular dose (MGD) and entrance surface air kerma (ESAK)] and the diagnostic performance of phase-contrast mammography with synchrotron radiation (MSR) are compared to conventional digital mammography (DM). Seventy-one patients (age range, 41 to 82 years) underwent MSR after a DM examination if questionable or suspicious breast abnormalities were not clarified by ultrasonography. The MGD and the ESAK delivered in both examinations were evaluated and compared. Two on-site radiologists rated the images in consensus according to the Breast Imaging Reporting and Data System assessment categories, which were then correlated with the final diagnoses by means of statistical generalized linear models (GLMs). Receiver operating characteristic curves were also used to assess the diagnostic performance by comparing the area under the curve (AUC). An important MGD and ESAK reduction was observed in MSR due to the monoenergetic beam. In particular, an average 43% reduction was observed for the MGD and a reduction of more than 50% for the ESAK. GLM showed higher diagnostic accuracy, especially in terms of specificity, for MSR, confirmed by AUC analysis ( ). The study design implied that the population was characterized by a high prevalence of disease and that the radiologists, who read the DM images before referring the patient to MSR, could have been influenced in their assessments. Within these limitations, the use of synchrotron radiation with the phase-contrast technique applied to mammography showed an important dose reduction and a higher diagnostic accuracy compared with DM. These results could further encourage research on the translation of x-ray phase-contrast imaging into the clinics.- 1 February 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 5 (01) , 013503-9
Dose and diagnostic performance comparison between phase-contrast mammography with synchrotron radiation and digital mammography: a clinical study report
Two dosimetric quantities [mean glandular dose (MGD) and entrance surface air kerma (ESAK)] and the diagnostic performance of phase-contrast mammography with synchrotron radiation (MSR) are compared to conventional digital mammography (DM). Seventy-one patients (age range, 41 to 82 years) underwent MSR after a DM examination if questionable or suspicious breast abnormalities were not clarified by ultrasonography. The MGD and the ESAK delivered in both examinations were evaluated and compared. Two on-site radiologists rated the images in consensus according to the Breast Imaging Reporting and Data System assessment categories, which were then correlated with the final diagnoses by means of statistical generalized linear models (GLMs). Receiver operating characteristic curves were also used to assess the diagnostic performance by comparing the area under the curve (AUC). An important MGD and ESAK reduction was observed in MSR due to the monoenergetic beam. In particular, an average 43% reduction was observed for the MGD and a reduction of more than 50% for the ESAK. GLM showed higher diagnostic accuracy, especially in terms of specificity, for MSR, confirmed by AUC analysis ( ). The study design implied that the population was characterized by a high prevalence of disease and that the radiologists, who read the DM images before referring the patient to MSR, could have been influenced in their assessments. Within these limitations, the use of synchrotron radiation with the phase-contrast technique applied to mammography showed an important dose reduction and a higher diagnostic accuracy compared with DM. These results could further encourage research on the translation of x-ray phase-contrast imaging into the clinics.- Open Access
- 10 January 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-14
A Gaussian extension for Diffraction Enhanced Imaging
Unlike conventional x-ray attenuation one of the advantages of phase contrast x-ray imaging is its capability of extracting useful physical properties of the sample. In particular the possibility to obtain information from small angle scattering about unresolvable structures with sub-pixel resolution sensitivity has drawn attention for both medical and material science applications. We report on a novel algorithm for the analyzer based x-ray phase contrast imaging modality, which allows the robust separation of absorption, refraction and scattering effects from three measured x-ray images. This analytical approach is based on a simple Gaussian description of the analyzer transmission function and this method is capable of retrieving refraction and small angle scattering angles in the full angular range typical of biological samples. After a validation of the algorithm with a simulation code, which demonstrated the potential of this highly sensitive method, we have applied this theoretical framework to experimental data on a phantom and biological tissues obtained with synchrotron radiation. Owing to its extended angular acceptance range the algorithm allows precise assessment of local scattering distributions at biocompatible radiation doses, which in turn might yield a quantitative characterization tool with sufficient structural sensitivity on a submicron length scale.
- 10 January 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-14
Open AccessA Gaussian extension for Diffraction Enhanced Imaging
Unlike conventional x-ray attenuation one of the advantages of phase contrast x-ray imaging is its capability of extracting useful physical properties of the sample. In particular the possibility to obtain information from small angle scattering about unresolvable structures with sub-pixel resolution sensitivity has drawn attention for both medical and material science applications. We report on a novel algorithm for the analyzer based x-ray phase contrast imaging modality, which allows the robust separation of absorption, refraction and scattering effects from three measured x-ray images. This analytical approach is based on a simple Gaussian description of the analyzer transmission function and this method is capable of retrieving refraction and small angle scattering angles in the full angular range typical of biological samples. After a validation of the algorithm with a simulation code, which demonstrated the potential of this highly sensitive method, we have applied this theoretical framework to experimental data on a phantom and biological tissues obtained with synchrotron radiation. Owing to its extended angular acceptance range the algorithm allows precise assessment of local scattering distributions at biocompatible radiation doses, which in turn might yield a quantitative characterization tool with sufficient structural sensitivity on a submicron length scale.
- 1 February 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (2) , C02062
Analyzer-based imaging system performance in a synchrotron clinical environment: a feasibility study
X-ray phase contrast imaging arises from changes of the propagation direction of the radiant wave field when traversing the object and it can yield higher contrast for soft tissues than conventional x-ray radiology based on attenuation. Commonly intermediate steps are required to transform wave front modulations into intensity modulations measurable by the detection system. One of these phase contrast techniques is analyzer-based imaging (ABI), which utilizes an analyzer crystal as angular filter with a bandwidth in the micro-radian regime placed between the sample and the detector. Furthermore employing appropriate algorithms, attenuation, refraction and scattering/dark field images can be extracted providing complementary information. The implementation of ABI requires X-ray optics with very high stability and micro-radian resolution. In return, this method possesses an extremely high sensitivity among the phase contrast techniques. At the medical beamline of the Italian synchrotron ELETTRA, a patient room has been implemented in order to perform clinical mammography with free-space propagation phase contrast. In this work we have tested the feasibility of ABI in a preclinical set-up implementing the system in the patient room. High quality images of breast tissues samples are presented and compared to images acquired at a conventional mammography unit. The system has shown excellent stability and imaging performances.
- 1 February 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (2) , C02062
Analyzer-based imaging system performance in a synchrotron clinical environment: a feasibility study
X-ray phase contrast imaging arises from changes of the propagation direction of the radiant wave field when traversing the object and it can yield higher contrast for soft tissues than conventional x-ray radiology based on attenuation. Commonly intermediate steps are required to transform wave front modulations into intensity modulations measurable by the detection system. One of these phase contrast techniques is analyzer-based imaging (ABI), which utilizes an analyzer crystal as angular filter with a bandwidth in the micro-radian regime placed between the sample and the detector. Furthermore employing appropriate algorithms, attenuation, refraction and scattering/dark field images can be extracted providing complementary information. The implementation of ABI requires X-ray optics with very high stability and micro-radian resolution. In return, this method possesses an extremely high sensitivity among the phase contrast techniques. At the medical beamline of the Italian synchrotron ELETTRA, a patient room has been implemented in order to perform clinical mammography with free-space propagation phase contrast. In this work we have tested the feasibility of ABI in a preclinical set-up implementing the system in the patient room. High quality images of breast tissues samples are presented and compared to images acquired at a conventional mammography unit. The system has shown excellent stability and imaging performances.